Loading...
HomeMy WebLinkAboutSurveyRECENED I�i1�►�e: 'jig 1 at, Lucle County Permitting DESCRIPTION LOT 2, POSTOBELLO, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 43, PAGE 30, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA JOB # 21-060 DATE: 4/16/2021 NATIONAL FLOOD INSURANCE PROGRAM DATA COMMUNITY PANEL No. 12111 C01 60 J FIRM DATE: 2/16/16 FLOOD ZONES: X CERTIFIED TO: JOSE A. VIDES-SIERRA & LISA K. VIDES POND INFO PROPOSED POND WILL BE 7.5' DEEP FROM EXISTING GRADE OF 17.1 BANKS WILL BE SLOPED WITH 4 TO 1 GRADE. POND CALCULATIONS QUANITY 1 BANK SLOPED 4 TO 1 DEPTH AT CENTER POINT NOT TO EXCEED 7.5' APPROXIMATE POND AREA IS 2940 S.F. SOD WILL BE PLACED FOR EROSIAN CONTROL AFTER EXCAVATION AT BANKS DISTANCE FROM SEPTIC TO EDGE OF POND WILL BE A MINIMUM OF 75 FEET SURVEYORS NOTES 1) LANDS SHOWN HEREON HAVE NOT BEEN ABSTRACTED BY THIS OFFICE FOR EASEMENTS, RESERVATIONS. OR RIGHTS OF WAY OF RECORD. 2) SUBSURFACE IMPROVEMENTS OF ENCROACHMENTS WERE NOT LOCATED OR SHOWN HEREON. 3) ONLY IMPROVEMENTS LOCATED ARE THOSE SHOWN HEREON. 4) THE SURVEY OF PROPERTY SHOWN IS IN ACCORDANCE WITH DESCRIPTION FURNISHED BY CLIENT OR CLIENTS REPRESENTATIVE 5) NO SEARCH OF THE PUBLIC RECORDS HAS BEEN MADE BY THIS OFFICE FOR CURRENCY, ACCURACY OR OMISSIONS OF DESCRIPTION FURNISHED. 6) THIS SURVEY IS NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 7) ALL DIMENSIONS SHOWN HEREON ARE PER DEED UNLESS OTHERWISE NOTED. LEGEND: A Arc A/C Air Conditioner P.B.C.R. Palm Beach County Records BFP Back Flow Preventer PG Page BM Bench Mark PLS Professional Land Surveyor (C) Calculated Data PL Planter Ch Chord PM Parking Meter (CFT) Calculated from Field Traverse P❑C Point of Commencement CLF Chain Link Fence PB Plat Book CLIP Concrete Light Pole UP Utility Pole C/L Center Line PK Parker/Kalon Nail CM Concrete Monument PM Parking Meter C.B. Catch Basin PRC Point of Reverse Curvature Conc Concrete PRM Permanent Reference Monument D Central angle of Curve PSM Professional Surveyor & Mapper (D) Data Per Record Deed PT Point of Tangency IIMH Drainage Manhole R Radius EL Elevation RCP Reenforced Concrete Pipe FND Found R/W Right -of -Way FF Finish Floor S Sign FH Fire Hydrant SS Stop Sign FOB Fiber Optic Box SB&T MH Southern Bell Telephone Manhole FP&L Florida Power & Light SBT LINE Southern Bell Telephone Line GC Gas Cap SMH Sanitary Manhole GV Gas Valve SL Street Light IP Iron Pipe SLB Street Light Box IR IRC Iron Rod Iron Rod and Cap SV Sewer Valve TS Traffic Signal LB Licensed Business TSB Traffic Signal Box LP Light Pole U/G Underground M Measured MH Man Hole UP Utility Pole t Plus or Minus WM Water Meter NGVD National Geodetic WV Water Valve Vertical Datum E❑P Edge of Pavement ORB Official Records Book E❑W Edge of Water ❑/H Overhead ELEC. Electric PC Point of Curvature Fire Hydrant P❑B Point of Beginning PCC Point of Compound Curvature PCP Permanent Control Point ® Fnd Iron Rod & Cap Illegible C I HEREBY CERTIFY THAT THE SURVEY SHOWN HEREON IS A TRUE AND CORRECT REPRESENTATION OF A FIELD SURVEY PERFORMED UNDER MY DIRECTION AND MEETS THE MINIMUM TECHNICAL STANDARDS ADOPTED BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS PURSUANT TO SECTION 472.027 FLORIDA STATUTES AND FLORIDA ADMINISTRATIVE CODE CHAPTER 611317-6 AND IS ACCURATE TO THE BEST OF MY KNOWLEDGE AND BELIEF. I SCALE: 1 " = 40' f% fv t. u.9 �4 { i f I =' '­ojects 3\21-J❑BS\21-060\dwg\21-060.dwg 4/19/2021 92557 AM EDT TERRY L. MACDEVITT, P.S.M. FLORIDA CERTIFICATION NO. LS 4557 SHEET 1 OF 1 REVISION I DATE I BY I CHK