HomeMy WebLinkAboutBLOWER DOOR TEST60i i-O IN G D(p -T,
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
Date: / / I Permit #: / % f-/ — 0 6 3 0
Contractor:
Job Address:
Construction: ever Construction — Complete ) Existing — After Addition
House Infiltration Te t Results SLC Climate Zone 2
CFM (50) = T
Volume = 77, YO 4. 7
ACFI (50) = CFM (50) x 60 / Volume = 3,. I I L
Passing results must be & ACFI (50) or less
Test Date: O 1� Z�
Mechankal VentiiatL required less than .3 ACif
ass ( )Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes pe'r
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in.
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
sa.I-S-ol
Testin Cg_ompiLny
Company Name: EAS1" C.01k51' TOW lFYt D66 kAddress: V8' C.DP-9 ktli m1 , ALM ,� &t )C-L
I hereby certify that the ajae Douse Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accqpd-ajrdle with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: ^ Lrylf V A-N "ID" use a
License/Certification #: �� S-0J � �t.3 6®