HomeMy WebLinkAboutEngineering Schmitt S1210720- Jensen Beach-signedCATEGORY
Engineering Services, Inc. 5
Property: Schmitt
9550 S Ocean Dr #PH3
Jensen Beach, FL
1600 S. Federal Hwy Ste 207, Pompano Beach, FL 33062
(954) 784-6991 Tel • (954) 781-5708 Fax • amanda@c5es.com • CA #25854
FBC, 7th Ed. (2020) / ASCE 7-16
WIND PRESSURES FOR COMPONENTS AND CLADDING
Prepared By AS
Opening
ID
Product
Approval
Opening
Description
Location
Zone
Opening
Elevation
Opening Dimensions
Width Height
Required Pressure
(per ASCE 7-10)
Product Design Pressure
(per NOA)
WINDOWS/DOORS
(in) (in)
Positive (psj)
Negative (psj)
Positive (psj)
Negative (psj)
la
FL 29677.2
Sliding Glass Door
4
210
72 x 96 3/4
61.4
-63.1
80.0
-130.0
lb
FL 21899.2
Window Wall
4
210
32 1/4 x 96
66.0
-66.2
100.0
-130.0
2a
FL 21899.2
Window Wall
4
210
41 1/2 x 96
64.6
-65.2
100.0
-130.0
2b
FL 29677.2
Sliding Glass Door
4
210
144 3/4 x 97 1/2
57.3
-60.4
76.8
-124.8
2c
FL 21899.2
Window Wall
4
210
41 1/2 x 96
64.6
-65.2
100.0
-130.0
3
FL 29677.2
Sliding Glass Door
4
210
70 1/2 x 96 3/4
61.5
-63.1
80.0
-130.0
4
FL 29677.2
Sliding Glass Door
4
210
141 1/2 x 97
57.5
-60.5
80.0
-130.0
Ultimate Wind Speed (V if) (mph)
170
Exposure Category
D
Internal Pressure Coeffient (Gcpi)
0.18
Directionality Factor (Kd)
0.85
Mean Roof Heightyi)
210
Width of Edge Strip (R)
10
These wind pressures have been prepared in accordance with the Florida Building Code, 7th Edition (2020). The
allowable pressures provided here (Wald) are given as 0.6*W ,,, where W 1, is the wind pressure calculated in accordance
with Chapters 26 to 30 of ASCE 7-16 using the ultimate design wind speed (V „) and the parameters given herein. Way
as provided here is an appropriate load for use when:
1) Evaluating tested products for components and cladding;
2) Designing mullions, framing, and other supporting structures using Allowable Stress Design;
3) Specifying fastener schedules using Allowable Stress Design.
The load combinations specified in Section 1605.3 of the 2020 FBC shall be applied. No further reduction in allowable
stress shall be taken (other than load duration per Chapter 23 FBC).
Emma T. Mellinger, P.E.
FL PE# 50049
7/20/2021
SSWS1210720 2021-RO
.111111118._
DK
DK
DK
DK
DK
DK
DK
�`P• • E' 7��' .
No 50049
Emma MellinT:p
2021.07.21 i"0'.. STATE OF
08:17:05-04'00"�'.,�`'c� 0 R �op'GN�.�,
11
N AL E����•
1111111