HomeMy WebLinkAboutEngineering Schmitt S1210720- Jensen Beach-signedCATEGORY Engineering Services, Inc. 5 Property: Schmitt 9550 S Ocean Dr #PH3 Jensen Beach, FL 1600 S. Federal Hwy Ste 207, Pompano Beach, FL 33062 (954) 784-6991 Tel • (954) 781-5708 Fax • amanda@c5es.com • CA #25854 FBC, 7th Ed. (2020) / ASCE 7-16 WIND PRESSURES FOR COMPONENTS AND CLADDING Prepared By AS Opening ID Product Approval Opening Description Location Zone Opening Elevation Opening Dimensions Width Height Required Pressure (per ASCE 7-10) Product Design Pressure (per NOA) WINDOWS/DOORS (in) (in) Positive (psj) Negative (psj) Positive (psj) Negative (psj) la FL 29677.2 Sliding Glass Door 4 210 72 x 96 3/4 61.4 -63.1 80.0 -130.0 lb FL 21899.2 Window Wall 4 210 32 1/4 x 96 66.0 -66.2 100.0 -130.0 2a FL 21899.2 Window Wall 4 210 41 1/2 x 96 64.6 -65.2 100.0 -130.0 2b FL 29677.2 Sliding Glass Door 4 210 144 3/4 x 97 1/2 57.3 -60.4 76.8 -124.8 2c FL 21899.2 Window Wall 4 210 41 1/2 x 96 64.6 -65.2 100.0 -130.0 3 FL 29677.2 Sliding Glass Door 4 210 70 1/2 x 96 3/4 61.5 -63.1 80.0 -130.0 4 FL 29677.2 Sliding Glass Door 4 210 141 1/2 x 97 57.5 -60.5 80.0 -130.0 Ultimate Wind Speed (V if) (mph) 170 Exposure Category D Internal Pressure Coeffient (Gcpi) 0.18 Directionality Factor (Kd) 0.85 Mean Roof Heightyi) 210 Width of Edge Strip (R) 10 These wind pressures have been prepared in accordance with the Florida Building Code, 7th Edition (2020). The allowable pressures provided here (Wald) are given as 0.6*W ,,, where W 1, is the wind pressure calculated in accordance with Chapters 26 to 30 of ASCE 7-16 using the ultimate design wind speed (V „) and the parameters given herein. Way as provided here is an appropriate load for use when: 1) Evaluating tested products for components and cladding; 2) Designing mullions, framing, and other supporting structures using Allowable Stress Design; 3) Specifying fastener schedules using Allowable Stress Design. The load combinations specified in Section 1605.3 of the 2020 FBC shall be applied. No further reduction in allowable stress shall be taken (other than load duration per Chapter 23 FBC). Emma T. Mellinger, P.E. FL PE# 50049 7/20/2021 SSWS1210720 2021-RO .111111118._ DK DK DK DK DK DK DK �`P• • E' 7��' . No 50049 Emma MellinT:p 2021.07.21 i"0'.. STATE OF 08:17:05-04'00"�'.,�`'c� 0 R �op'GN�.�, 11 N AL E����• 1111111