Loading...
HomeMy WebLinkAboutAPPROVED RoofingPermitInformationSh,TIToLUM o ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6.7 Metal Roofs A, B, D 1,2,3,4,5,6,7 Wood Shingles and Shakes Other A, B, D 1,2,4,5,6,7 1,2,3,4,5,6,7 As Applicable ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval Municipal Permit Application 5. 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 5T. LUCI E Master Permit No. Contractors Name: Section A (General Information) Process No. Jorge morel) License # CCC 1330665 Job Address 314 S ERIE DR, Fort Price ® Low Slope ❑ Asphaltic Shingles ❑ New roof ❑ Repair Low Slope Roof Area (SF) 7500 ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR-RAS 15C ROOF ROOF TYPE. ❑ Maintenance ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) ❑ Mortar/Adhesive Set Tiles ❑Wood Shingles/Shakes ❑ Reroofing ❑ Recovering Total (SF) 7500 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: GAF Product Approval No.: 18-0919.12 Design Wind Pressures, From RAS 128 Or Calculations Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Wood deck Gauge Thickness: 518 Slope: 1/4 in 12 Anchor/Base Sheet & No. df Ply(s): GafGlass #80 Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1': 6 " oc @ Lap, # Rows 3 @ 6 n oc Zone 1:6 " oc @ Lap, # Rows 3 @ 6 " Or - Zone 2: 3 " oc @ Lap, # Rows 11 @ 3 "oc Zone 3: 3 " oc @ Lap, # Rows 11 @ 3 n oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r: Deck Type: Type Underlayment: Roof Slope: 12 Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: Adhesive Type: Type Cap Sheet: Mean Roof Height: Roof Covering: Type & Size Drip Edge: ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Ms. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method VMoment Based Tile Calculations Per RAS 12T (Zone 1: x _ ) » Mg: = Mr, Product Approval Mi (Zone 2e: x _ ) -Mg: = M,a Product Approval Mt - (zone 2n: x _ _) -Mg: = Mom, Product Approval Ms (Zone 2r: x _ ) - Mg: = M Product Approval Ms (Zone 3e: X - )"Mg: =Mr,, Product ApprovalMf (Zone 3r: x a. _ ) Mg', = Mrar Product Approval Ms Method 2 "Simplified Tile Calculations Per Table Below" _ /� \ r........ T-.L t- 0,1- Prmillrt Annroval Ms- -%tfgUIICU IVIVIIICIII VI I �I�u"�- '•'i/ •'""' '-'-'- ---- - - Mr required Moment Resistance* Mean Roof Height Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction wan a list or momenr, Ud�A!u IIIC JYZ0LCl11a • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= ) -W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= ) -W: cos r =Fr2n Product Approval F' (Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:= ) -W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:= ) -W: cos r =Fr3r Product Approval F' Where to Obtain Information Description Symbol Where to!byan Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 orngineenanalysis prepared by PE based on ASCE 7 H Job Site Job Site Mean Roof Height Roof Slope 6 A Product Approval Aerodynamic Multiplier Mg Mr Product Approval Product Approval Restoring Moment due to Gravity Attachment Resistance Mg Calculated Required Moment Resistance Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated W Product Approval Average Tile Weight L = length W = width Product Approval Tile Dimensions All calculations must be submitted to the building official at the time of permit application.