Loading...
HomeMy WebLinkAboutAPPROVED torchDown180919.12 MIAMbDADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid®Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 15-1020.01 and consists of pages 1 through 67. The submitted documentation was reviewed by Jorge L.Acebo. .�J NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 1 of 67 ROOFING SYSTEM APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -105 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLAS®Ply 4 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter)Wide reinforced with fiberglass mat. Tri-Ply®Ply 4 Ply Sheet 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet (1 meter)Wide reinforced with fiberglass mat. GAFGLAS® 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet FlexPly'6 (1 meter)Wide reinforced with fiberglass mat. GAFGLAS®#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter)Wide reinforced with fiberglass mat. Tri-Ply®#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet (1 meter)Wide reinforced with fiberglass mat. GAFGLAS®#80 UltimaTM Base 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet Sheet (1 meter)Wide reinforced with fiberglass mat. GAFGLAS® Stratavent® 39.37" ASTM D4897 Smooth surfaced asphaltic perforated Perforated Venting Base Sheet (1 meter)Wide venting base sheet reinforced with fiberglass mat. GAFGLAS® Stratavent® 39.37" ASTM D4897 Smooth surfaced asphaltic nailable venting Nailable Venting Base Sheet (1 meter)Wide base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. Ruberoid®HW 25 Smooth 39.37" ASTM D6163 Smooth surfaced torch applied SBS base (1 meter)Wide or ply sheet reinforced with a fiberglass mat. Ruberoid®HW Smooth 39.37" ASTM D6164 Smooth surfaced torch applied SBS base (1 meter)Wide or ply sheet reinforced with a polyester mat. Ruberoid®HW Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid®HW Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced heat- (1 meter)Wide welded SBS cap sheet reinforced with a polyester mat. Ruberoid®HW Plus Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid®HW Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced torch FR (1 meter)Wide applied SBS cap sheet reinforced with a polyester mat. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 2 of 67 Test Product Product Dimensions Specification Description Ruberoid®EnergyCap"HW 1 meter ASTM D6164 Fire retardant granule surfaced heat- Plus Granule FR (39.37")Wide welded SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT®EnergyCote' Elastomeric Coating. Ruberoid®Torch Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP base (1 meter)Wide or ply sheet reinforced with a polyester mat. Tri-Ply®APP Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP cap, Membrane (1 meter)Wide base or ply sheet reinforced with a polyester mat. Ruberoid®Torch Granule 39.37" ASTM D6222 Granule surfaced torch applied APP cap (1 meter)Wide sheet reinforced with a polyester mat. Tri-Ply®APP Granule Cap 39.37" ASTM D6222 Granule surfaced torch applied APP cap Sheet (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid®Torch Plus Granule 39.37" ASTM D6222 Fire retardant granule surfaced torch FR (1 meter)Wide applied APP cap sheet reinforced with a polyester mat. Ruberoid® EnergyCap" 39.37" ASTM D6222 Fire retardant granule surfaced torch Torch Plus Granule FR (1 meter)Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT®EnergyCote' Elastomeric Coating. Ruberoid® EnergyCap'M 39.37" ASTM D6222 Fire retardant granule surfaced torch Torch Granule FR (1 meter)Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT®EnergyCote'm Elastomeric Coating. Ruberoid®20 Smooth 39.37" ASTM D6163 SBS polymer-modified asphalt base or ply (1 meter)Wide sheet reinforced with a fiberglass mat. Ruberoid®30 Granule 39.37" ASTM D6163 Granule surfaced mop applied SBS cap (1 meter)Wide sheet reinforced with a fiberglass mat. Ruberoid®30 Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop (1 meter)Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoid®30 Plus Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop (1 meter)Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoid°Mop Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter)Wide sheet reinforced with a polyester mat. Tri-Ply® SBS Granule Cap 39.37" ASTM D6164 Granule surfaced mop applied SBS cap Sheet (1 meter)Wide sheet reinforced with a polyester mat. Intec Flex PRF 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid®Mop Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (1 meter)Wide sheet reinforced with a polyester mat. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 3 of 67 Test Product Product Dimensions Specification Description Ruberoid®Mop Smooth 1.5 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid®Mop Plus Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter)Wide ply sheet reinforced with a polyester mat. Ruberoid®Mop Plus Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter)Wide sheet reinforced with a polyester mat. Ruberoid®Mop Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced mop FR (1 meter)Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid®EnergyCap'Mop 39.37" ASTM D6164 Fire retardant granule surfaced mop Plus Granule FR (1 meter)Wide applied SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT®EnergyCote' Elastomeric Coating. Ruberoid®Mop Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced mop (1 meter)Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid®EnergyCap'30 39.37" ASTM D6163 Fire retardant granule surfaced mop Granule FR (1 meter)Wide applied SBS cap sheet reinforced with a fiberglass mat. Cap sheet is factory coated with TOPCOAT®EnergyCote' Elastomeric Coating. GAFGLAS®Mineral-Surfaced 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Cap Sheet (1 meter)Wide reinforced with fiberglass mat. Tri-Ply®BUR Granule Cap 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Sheet (1 meter)wide reinforced with a fiberglass mat. GAFGLAS®EnergyCap" 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Mineral-Surfaced Cap Sheet (1 meter)Wide reinforced with fiberglass mat. Cap sheet is factory coated with TOPCOAT® EnergyCote'Elastomeric Coating. TOPCOAT® Membrane 1, 5 or 55 gallons ASTM D6083 Water based elastomeric coating. United CoatingsTM Roof Mate 1, 5 or 55 ASTM D6083 Water-based elastomeric coating TCM Coating Gallons TOPCOAT® 5 or 55 gallons ASTM D6083 Solvent based thermoplastic rubber sealant Surface Seal SB designed to protect and restore aged roof surfaces and to increase roof reflectivity. United CoatingsTM Surface Seal 5 or 55 Gallons ASTM D6083 Solvent-based thermoplastic rubber SB Roof Coating sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. TOPCOAT®MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer used to block asphalt bleed-through. United CoatingsTM Roof Mate 5 or 55 Gallons Proprietary Water based, low VOC primer designed to MB Plus Coating block asphalt bleed-through. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 4 of 67 Test Product Product Dimensions Specification Description FireOutT"Fire Barrier Coating 5 or 55 gallons Proprietary Low VOC,water-based fire barrier coating. Flex Seal`' 1, 5 gallons TAS 139 Solvent-based elastomeric sealant. or 1 qt.tube VersaShield®Fire-Resistant 12"x 100' rolls ASTM D226 Non-asphaltic fiberglass-based Roof Deck Protection underlayment and/or fire barrier. VersaShield® Solo'Fire- 42" roll wide, ASTM D146, Non-asphaltic, fire resistant fiberglass Resistant Slip Sheet 100 ft. D828,D4869, underlayment D6757 Matrix" 102 SBS Membrane 3, 5 or 55 gallons ASTM D3019 Fiber reinforced rubberized cold-applied Adhesive adhesive for modified bitumen roof systems. APPROVED INSULATIONS: Table 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuard"Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuardT'Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard"RA Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard"RH Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard"RH Tapered Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard'm RN Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard"Perlite Recover Board Perlite recover board GAF EnergyGuard"Perlite Roof Insulation Perlite insulation board GAF EnergyGuard"RA Composite Polyiso Polyisocyanurate foam insulation GAF Insulation with high density fiberboard or permalite Structodek®High Density Fiberboard Roof High density fiberboard Blue Ridge Fiberboard,Inc. Insulation SECUROCK®Gypsum-Fiber Roof Board Gypsum board United States Gypsum Corp. SECUROCK®Glass-Mat Roof Board Gypsum board United States Gypsum Corp. DensDeck®Roof Board Gypsum board Georgia-Pacific DensDeck®Prime Roof Board Gypsum board Georgia-Pacific NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 5 of 67 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec'#12 Fastener Phillips head,modified #12 x 8" GAF buttress thread,pinch Max.Length point, carbon steel fastener #3 Phillips for use in steel or wood head. decks. With CR-10 coating.Available with a pinch point or drill point. 2. Drill-Tec'#14 Fastener Truss head, self-drilling, #14 x 16" GAF pinch point,high thread Max.Length fastener for use in steel, #3 Phillips wood or concrete decks. head. 3. Drill-Tec'XHD Fastener Truss head, self-drilling, #15 x 16" GAF pinch point,high thread Max.Length fastener for use in wood or #3 Phillips steel decks. Carbon steel head. extra heavy duty fastener used in steel decks. 4. Drill-Tec'3" Steel Plate Round Galvalume® steel 3" Round GAF stress plate with reinforcing ribs and recessed for use with Drill- Tec'fasteners. 5. Drill-Tec'3" Standard Galvalume®coated steel 3" Round GAF Steel Plate stress plate for use with approved Drill-Tec'm fasteners. 6. Drill-Tec' ASAP 3 S Drill-Tec'#12 fastener #12 x 8" GAF with Drill-Tec'm 3" Max.Length Standard Steel Plate. #3 Phillips head with 3" Round plate 7. Drill-Tec'AccuTrac®Flat A2-SS aluminized steel 3" square; GAF Plate plate for use with Drill- .017"thick Tec'fasteners. 8. Drill-Tec'AccuTrac® Galvalume® steel plate 3" square; GAF Recessed Plate with recess for use with .017"thick. Drill-Tec'fasteners. 9. Drill-Tec'3 in. Ribbed Round Galvalume®plated 3"Round GAF Galvalume Plate(Flat) steel stress plate with reinforcing ribs for use with Drill-Tec'm fasteners. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 6 of 67 EVIDENCE SUBMITTED: Test Aj!ency Test Identifier Description Date FM Approvals 3001276 FMRC 4470 01/28/99 3010215 FMRC 4470 03/01/01 3029832 FMRC 4470 05/11/07 3036980 FMRC 4470 08/14/09 3034312 FMRC 4470 04/09/09 3040738 FMRC 4470 05/18/12 3042887 FMRC 4470 11/14/11 3046081 FMRC 4470 02/13/13 3043633 FMRC 4470 01/20/12 1B9A8.AM FMRC 4470 09/04/97 3B9Q1.AM FMRC 4470 01/08/08 3D4Q2.AM FMRC 4470 04/30/97 OD1A8.AM FMRC 4470 04/01/98 797-03221-267 FMRC 4470 09/24/07 797-10228-267 FMRC 4470 01/15/15 797-04694-267 FMRC 4470 06/17/09 797-03825-267 FMRC 4470 07/14/08 RR203450 FMRC 4470 12/04/15 FM Letter FMRC 4470 04/11/13 FM Letter FMRC 4470 09/15/15 UL LLC R1306 UL 790 08/21/18 IRT-ARGON Inc. 02-005 TAS 114-J 07/19/04 02-014 TAS 114-J 04/08/02 Trinity I ERD C8500SC.11.07 ASTM D6862 11/30/07 G30250.02.10-2 ASTM D6222 11/11/10 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G32520.06.11 ASTM D1876 06/28/11 G33470.01.11 ASTM D6164 01/13/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D4601 6/4/2015 G34140.04.11-5-R3 ASTM D4897 6/4/2015 G36780.07.11-R1 TAS 114-J 07/18/11 G40620.07.12-2 ASTM D6222 07/17/12 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D5147 01/07/14 G40630.01.14-2A-1-RI ASTM D6164 04/10/14 G40630.01.14-2B-RI ASTM D6164 01/16/15 G40630.01.14-2C ASTM D6164 01/07/14 G40630.03.14 ASTM D5147 03/06/14 G43190.03.14-1 ASTM D5147 03/06/14 G43190.03.14-2 ASTM D5147 03/06/14 G43190.05.14-R1 ASTM D5147 05/20/14 G43610.01.14 ASTM D5147 01/22/14 NOA No.: 18-0919.12 CADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/O1/18 Page 7 of 67 EVIDENCE SUBMITTED: (CONTINUED) Test Aj!ency Test Identifier Description Date Trinity I ERD G43190.11.13-1 ASTM D6222 11/15/13 G46160.02.15 ASTM D6163 02/12/15 G46160.02.15-2D-1 ASTM D6163 02/09/16 G46160.03.15 ASTM D6163 03/11/15 G46160.09.14-2A ASTM D5147 09/09/14 G46160.09.14-3A ASTM D6164 09/09/14 G46160.09.14-3B ASTM D6164 09/09/14 G46160.09.14-3C ASTM D5147 09/09/14 G46160.12.14-3E ASTM D6164 12/29/14 G6850.08.08 ASTM D6163 08/01/08 G6850.08.08-R1 ASTM D6164 04/14/11 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 02/17/09 SC6870.08.14-R1 ASTM D3909 09/04/14 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies,LLC GAF-245-02-01 ASTM D6083 06/10/10 GAF-276-02-01Rev ASTM E2178 01/04/11 ASTM D6083 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-434-02-03 TAS 114-J 09/06/13 GAF-434-02-04 TAS 114-J 09/06/13 GAF-464-02-01 ASTM C1289 02/06/14 GAF-498-02-01 ASTM D6083 09/16/16 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D1876 10/01/14 GAF-559-02-05 ASTM D1876 10/15/14 GAF-559-02-06 TAS 114(H) 10/02/14 GAF-559-02-07 ASTM D903 10/02/14 GAF-559-02-08 ASTM D903 10/02/14 GAF-559-02-09 ASTM D903 10/02/14 GAF-559-02-11 TAS 114-J 10/14/14 GAF-559-02-12 TAS 114-J 10/14/14 GAF-559-02-13 TAS 114-J 10/15/14 GAF-559-02-14 TAS 114-J 10/15/14 GAF-559-02-15 TAS 114-J 10/15/14 GAF-559-02-16 TAS 114-J 10/15/14 GAF-559-02-18 TAS 114-J 10/15/14 GAF-559-02-19 TAS 114-J 04/16/15 Dynatech Engineering Corporation #4482.02.95-1 TAS 114-C 09/01/95 NOA No.: 18-0919.12 MIAM4DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 8 of 67 APPROVED ASSEMBLIES Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut`'Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection (optional) or VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#80 Ultima""Base Sheet, GAFGLAS® Stratavent®Nailable Venting Base Sheet,Ruberoid®20 Smooth,Ruberoid®HW Smooth or Ruberoid®HW 25 Smooth base sheet mechanically fastened to deck as described below. Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exPly'6, Option#1: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exPly'6, Option#2: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecTM#12 Fastener,Drill-TecTM#14 Fastener or Drill-TecTM XHD Fastener and Drill-TecTM 3" Steel Plate,Drill-TecTM AccuTrace Flat Plate or Drill-TecTM AccuTrac®Recessed Plate installed 12"o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12.5"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®F1exP1yT 6, GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or Option#3: any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4"lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure—52.5 psf. See General Limitation#7) Fastening GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above anchor Option#4: sheets attached to deck with Drill-TecTM#12 Fastener,Drill-TecTM#14 Fastener or Drill-TecTM XHD Fastener and Drill-TecTM 3" Steel Plate,Drill-TecTM AccuTraca Flat Plate or Drill-TecTM AccuTrac®Recessed Plate installed 12"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®#80 UltimaT Base Sheet,Ruberoid®20 Smooth,Ruberoid®Mop Option#5: Smooth base sheet attached to deck approved annular ring shank nails and 3" inverted Drill-TecTM 3" Steel Plate at a fastener spacing of 9" o.c. at the 4"lap staggered in two rows 9" in the field. (Maximum Design Pressure—60 psf. See General Limitation #7) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 9 of 67 Fastening GAFGLAS"#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above anchor Option#6: sheets attached to deck with Drill-Tec'#12 Fastener,Drill-Tec'#14 Fastener or Drill-Tec'XHD Fastener and Drill-Tec'3" Steel Plate,Drill-TecT"AccuTrace Flat Plate or Drill-TecT"AccuTrac®Recessed Plate installed 8"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard'"Polyiso Insulation,EnergyGuardT"Polyiso RA Insulation, EnergyGuard'"Polyiso RN Insulation,EnergyGuard'"RA Composite Polyiso Insulation Minimum 1"thick N/A N/A StructodeV High Density Fiber Board,EnergyGuardT'Perlite Recover Board Minimum 1/Z"thick N/A N/A EnergyGuardT'Perlite Roof Insulation Minimum 3/4"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft . Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS®Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuardT"Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional)Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, GAFGLAS®#80 Ultima'Base Sheet, GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet GAFGLAS®F1exP1y'm 6,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus Smooth,Ruberoid®20 Smooth,Ruberoid®HW Smooth or Ruberoid®HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). OR GAFGLAS® Stratavent®Perforated Venting Base Sheet loose-laid dry. Ply Sheet: (Optional,required over GAFGLAS® Stratavent®Perforated Venting Base Sheet loose-laid dry)One or more plies GAFGLAS®Ply 4, GAFGLAS®F1exPly� 6 , GAFGLAS®#80 Ultima' Base Sheet,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus Smooth,Ruberoid®20 Smooth adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 10 of 67 Membrane: One or more plies of Ruberoid®20 Smooth,Ruberoid®30 Granule,Ruberoid® EnergyCapTM 30 Granule FR,Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid® Mop Plus Smooth,Ruberoid®Mop Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF ,Ruberoid®Mop Plus Granule, Ruberoid®Mop Plus Granule FR fully adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 11 of 67 Membrane Type: APP/SBS Heat Weld Deck Type 1I: Wood,Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(2): Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. Fire Barrier: FireOut'Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection, (optional) VersaShield® Solo'Fire-Resistant Slip Sheet,DensDeck®Roof Board, SECUROCK®Gypsum-Fiber Roof Board, or SECUROCK®Glass-Mat Roof Board. Anchor sheet: GAFGLAS®#80 Ultima'Base Sheet, GAFGLAS® Stratavent®Nailable Venting Base Sheet,Ruberoid®20 Smooth,Ruberoid®HW Smooth or Ruberoid®HW 25 Smooth base sheet mechanically fastened to deck as described below; Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4, GAFGLAS®F1exPly'6, GAFGLAS®#75 Option#1: Base Sheet, Tri-Ply®#75 Base Sheet or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exPly'6, Option#2: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec'#12 Fastener or Drill-Tec'M#14 Fastener and Drill-TecT'3" Steel Plate,Drill-Tec'M AccuTrac®Flat Plate or Drill-Tec'M AccuTrac®Recessed Plate installed 12"o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12.5"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®F1exP1y"6, GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, Option#3: or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4"lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—52.5 psf. See General Limitation#7) GAFGLAS®#75 Base Sheet Tri-Ply®#75 Base Sheet or any of above anchor Fastening sheets attached to deck with Drill-Tec�`"'#12 Fastener or Drill-Tec'�M#14 Fastener Option#4: and Drill-Tec'3" Steel Plate,Drill-Tec'M AccuTrac®Flat Plate or Drill-Tec'M AccuTrac®Recessed Plate installed 12"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 12 of 67 Fastening GAFGLAS®#80 UltimaT Base Sheet,Ruberoid®20 Smooth,Ruberoid®Mop Option#5: Smooth base sheet attached to deck approved annular ring shank nails and 3" inverted Drill-TecTM 3" Steel Plate at a fastener spacing of 9" o.c. at the 4"lap staggered in two rows 9" in the field. Not for use with DensDeck and SECUROCK Fire Barrier (Maximum Design Pressure—60 psf. See General Limitation #7) Fastening GAFGLAS®#75 Base Sheet, Tri-Ply#75 Base Sheet, or any of above anchor Option#6• sheets attached to deck with Drill-Tec,,,,#12 Fastener or Drill-TecTM#14 Fastener and Drill-TecTM 3" Steel Plate,Drill-TecTM AccuTrac Flat Plate or Drill-Tec AccuTrac®Recessed Plate installed 8"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM RA Polyiso Insulation,EnergyGuardTM RA Composite Polyiso Insulation Minimum 1"thick N/A N/A Structodek®High Density Fiber Board,EnergyGuardTM Perlite Recover Board Minimum%"thick N/A N/A EnergyGuardTM Perlite Roof Insulation Minimum 3/a"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ff. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS®Stratavent° Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, GAFGLAS®#80 Ultima'Base Sheet, GAFGLAS®Ply 4, GAFGLAS®FlexPlyTM 6,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid Mop Plus Smooth,Ruberoid®20 Smooth,Ruberoid®HW Smooth or Ruberoid®HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq. (See General Limitation#4). OR GAFGLAS® Stratavent®Perforated Venting Base Sheet loose-laid dry. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 13 of 67 Ply Sheet: (Optional except over Ruberoid®Mop Smooth,Ruberoid®20 Smooth,Ruberoid® HW Smooth or Ruberoid®HW 25 Smooth or GAFGLAS® Stratavene Perforated Venting Base Sheet loose-laid dry) One or more plies GAFGLAS®Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS®F1exP1yTM 6 or GAFGLAS®#80 Ultima`'Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or Ruberoid®Torch Smooth or Tri-Ply®APP Smooth Membrane torch applied according to manufacturer's application instructions (Ruberoid®Torch Smooth or Tri-Ply®APP Smooth Membrane not to be used over GAFGLAS® Stratavene Perforated Venting Base Sheet). Membrane: One ply of Ruberoid®Torch Smooth, Tri-Ply®APP Smooth Membrane,Ruberoid® Torch Granule, Tri-Ply®APP Granule Cap Sheet,Ruberoid®EnergyCap'M Torch Granule FR, ,Ruberoid®EnergyCapTM Torch Plus Granule FR or Ruberoid®Torch Plus Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid®HW Plus Granule,Ruberoid®HW Plus Granule FR,Ruberoid®HW Granule FR,Ruberoid®EnergyCap"HW Plus Granule FR, Ruberoid®HW Granule,Ruberoid®HW Smooth and Ruberoid®HW 25 Smooth applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCap' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 14 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 Option#1: in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 Option#2: in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—75 psf,See General Limitation#7) One or more of any of the following. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 15 of 67 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Perlite Roof Insulation Minimum 3/4"thick N/A N/A StructodeV High Density Fiber Board Roof Insulation Minimum 1/Z"thick N/A N/A SECUROCK®Gypsum-Fiber Roof Board,DensDeck" Prime Minimum 1/4"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet or Tri-Ply®#75 Base Sheet. Adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Ply Sheet: Ruberoid®20 Smooth adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCap"Mop Plus Granule FR,Ruberoid®EnergyCap'30 Granule FR, GAFGLAS®Mineral- Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS® EnergyCap'Mineral-Surfaced Cap Sheet adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings"Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 16 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutT"Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 Option#1: in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 Option#2: in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-TecT'3 in. Standard Steel Plates,Drill-TecT" Option#3: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-TecT'3 in. Standard Steel Plates,Drill-TecT" Option#4: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-TecT'3 in. Standard Steel Plates,Drill-TecT" Option#5: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—75 psf,See General Limitation#7) One or more of the any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardT"Polyiso Insulation,EnergyGuardTmTapered Polyiso Insulation, EnergyGuardT"'Ultra Polyiso Insulation,EnergyGuardT"'RH Polyiso Insulation, EnergyGuardT'RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 17 of 67 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Perlite Roof Insulation Minimum 3/4"thick N/A N/A StructodeV High Density Fiber Board Minimum %"thick N/A N/A SECUROCK®Gypsum-Fiber Roof Board,DensDeck'Prime Minimum 1/4"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet or Tri-Ply®#75 Base Sheet. Adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Ply Sheet: Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5 or Ruberoid®20 Smooth adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR or Ruberoid® EnergyCapT'Mop Plus Granule FR adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. l. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCapT"Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings"Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 18 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type A(5): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut`'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—75 psf,See General Limitation #7) One or more of any of the following insulations. Base Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 19 of 67 Top Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Perlite Roof Insulation Minimum 3/4"thick N/A N/A StructodeV High Density Fiber Board Minimum 1/Z"thick N/A N/A SECUROCK®Gypsum-Fiber Roof Board,DensDeck'Prime Minimum 1/4"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Install one or more plies of Ruberoid®20 Smooth adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR, Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCapT'Mop Plus Granule FR,Ruberoid®EnergyCapT"30 Granule FR GAFGLAS®Mineral- Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS® EnergyCapT"Mineral-Surfaced Cap Sheet adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatings"Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings"Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 20 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type A(6): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut`'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—75 psf,See General Limitation #7) One or more of any of the following insulations. Base Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard'Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardT"RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 21 of 67 Top Layer Insulation Insulation Fasteners Fastener (Table 3) Density/W EnergyGuardTM Perlite Roof Insulation Minimum 3/4"thick N/A N/A StructodeV High Density Fiber Board Minimum 1/Z"thick N/A N/A SECUROCK®Gypsum-Fiber Roof Board,DensDeck" Prime Minimum 1/4"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Install one or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Membrane: Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR or Ruberoid® EnergyCapTM Mop Plus Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 22 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type A(7): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut`'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—75 psf,See General Limitation #7) One or more of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 23 of 67 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/W One of the following. EnergyGuard"Perlite Roof Insulation Minimum%"thick N/A N/A StructodeV High Density Fiber Board Minimum '/Z"thick N/A N/A SECUROCK®Gypsum-Fiber Roof Board,DensDecV Prime Minimum '/4"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet or Tri-Ply®#75 Base Sheet. Adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid® EnergyCap"30 Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR or Ruberoid®EnergyCap'Mop Plus Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 24 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(8): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOufm Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo`'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. I- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-Tec'3 in. Standard Steel Plates,Drill-TecT" Option#3: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-Tec'3 in. Standard Steel Plates,Drill-TecT" Option#4: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-Tec'3 in. Standard Steel Plates,Drill-TecT" Option#5: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—75 psf,See General Limitation#7) One or more of any of the following insulations. Base Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard'"Polyiso Insulation,EnergyGuardT"Tapered Polyiso Insulation, EnergyGuard'"Ultra Polyiso Insulation,EnergyGuard'"RH Polyiso Insulation, EnergyGuard'"RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 25 of 67 Top Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Perlite Roof Insulation Minimum 3/4"thick N/A N/A StructodeV High Density Fiber Board Minimum 1/Z"thick N/A N/A SECUROCK®Gypsum-Fiber Roof Board,DensDeck" Prime Minimum 1/4"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Two or more plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet or GAFGLAS®F1exP1y`6 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4). Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCap"Mop Plus Granule FR,Ruberoid®EnergyCap'30 Granule FR, GAFGLAS®Mineral- Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS® EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings"Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 26 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(9): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOufm Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo''Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. I- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-Tec'3 in. Standard Steel Plates,Drill-TecT" Option#3: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-Tec'3 in. Standard Steel Plates,Drill-TecT" Option#4: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecT"#14 Fasteners and Drill-Tec'3 in. Standard Steel Plates,Drill-TecT" Option#5: AccuTrac®Flat Plates or Drill-TecT"3 in.Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—75 psf,See General Limitation#7) Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ff EnergyGuardT"Polyiso Insulation,EnergyGuard'"Tapered Polyiso Insulation, EnergyGuardT"Ultra Polyiso Insulation,EnergyGuardT"RH Polyiso Insulation, EnergyGuardT"RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 27 of 67 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/W EnergyGuardT"Perlite Roof Insulation Minimum%"thick N/A N/A StructodeV High Density Fiber Board Minimum '/Z"thick N/A N/A SECUROCK®Gypsum-Fiber Roof Board,DensDecV Prime Minimum '/4"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Install one ply of Ruberoid®20 Smooth adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Ply Sheet: Ruberoid®Mop Smooth or Ruberoid®Mop Smooth 1.5 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR or Ruberoid® EnergyCap"Mop Plus Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCapT"Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings`' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings"Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 28 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(10): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo`'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. I- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-Teo`'3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—82.5 psf,See General Limitation #7) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 29 of 67 Base Sheet: GAFGLAS® Stratavene Perforated Venting Base Sheet is loose laid over the insulation with 2 in. side laps Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid® EnergyCap"30 Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCap'M Mop Plus Granule FR or Tri-Ply® SBS Granule Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 30 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(11): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet, or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—82.5 psf,See General Limitation #7) One or more layers of any of the following insulations. Base Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 31 of 67 Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: GAFGLAS® Stratavent®Perforated Venting Base Sheet is loosely-laid over the insulation with 2 in. side laps Ply Sheet: Two or more plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet or GAFGLAS®F1exP1yTm 6 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4). Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCapTM Mop Plus Granule FR,Ruberoid®EnergyCapT'30 Granule FR, GAFGLAS®Mineral- Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS® EnergyCapT'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 32 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(12): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo`'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. I- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-Teo`'3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option #5: AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—82.5 psf,See General Limitation #7) One or more layers of any of the following insulations. Insulation for Base Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 33 of 67 Base Sheet: GAFGLAS® Stratavent®Perforated Venting Base Sheet is loosely-laid over the insulation with 2 in. side laps Ply Sheet: Install one or more plies of Ruberoid®20 Smooth adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCap'm Mop Plus Granule FR,Ruberoid®EnergyCap`'30 Granule FR, GAFGLAS®Mineral- Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS® EnergyCap`'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatings`' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 34 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type A(13): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut`'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—82.5 psf,See General Limitation#7) One or more layers of any of the following insulations. Insulation for Base Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 35 of 67 Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: GAFGLAS® Stratavent®Perforated Venting Base Sheet is loosely-laid over the insulation with 2 in. side laps Ply Sheet: Install one or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Membrane: Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid® EnergyCap"Mop Plus Granule FR, GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral- Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatings'Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 36 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(14): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet, (optional) VersaShield® Solo`'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. I- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation#7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill- Option#3: TecTM AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat) are spaced 16 in. o.c. in the min. 4 in.wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill- Option#4: TecTM AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—67.5 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill- Option#5: TecTM AccuTrac®Flat Plates or Drill-TecTM 3 in.Ribbed Galvalume Plate(Flat) are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—82.5 psf,See General Limitation #7) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Polyiso Insulation,EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation,EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 37 of 67 Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: GAFGLAS® Stratavent®Perforated Venting Base Sheet is loosely-laid over the insulation with 2 in. side laps Interply Sheet: Install one ply of Ruberoid®20 Smooth adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Ply Sheet: Ruberoid®Mop Smooth or Ruberoid®Mop Smooth 1.5 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intee Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR or Ruberoid® EnergyCap"Mop Plus Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap"Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings"Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 38 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c.max System Type B(1): Base layer of insulation is mechanically attached to roof deck. Any subsequent layers are then adhered to base layer of insulation. Membrane is subsequently fully or partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck (optional) Protection,VersaShield® Solo'Fire-Resistant Slip Sheet,DensDecko Roof Board, SECUROCK®Gypsum-Fiber Roof Board or SECUROCK®Glass-Mat Roof Board. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM RA Polyiso Insulation Minimum 2.0"thick 1,2, 4, 5 1:3.2 ft2 EnergyGuardTM RN Polyiso Insulation Minimum 1.4"thick 1,2, 4, 5 1:3 ft' EnergyGuardTM Polyiso Insulation Minimum 1.5"thick 1,2, 4, 5 1:2 ft2 EnergyGuardTM Perlite Roof Insulation Minimum 3/4"thick 1,2, 4, 5 1:2 ft' Structodek®High Density Fiber Board Minimum 1"thick 1,2,4,5 1:2 ft' Note: Base layers of insulation shall be mechanically attached using the fastener density listed. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS®Stratavent®Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Any of the insulation listed for Base Layer,above. Minimum thickness same as above N/A N/A Structodek®High Density Fiber Board,EnergyGuardTM Perlite Recover Board Minimum%"thick N/A N/A NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 39 of 67 Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Base Sheet: (Optional)Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, GAFGLAS®#80 Ultima`'Base Sheet, GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yTM 6,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus Smooth or Ruberoid®20 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.; (See General Limitation #4). OR GAFGLAS® Stratavent®Perforated Venting Base Sheet loose laid dry(not for use with wood fiber board or perlite top layer insulation). Ply Sheet: (Optional)One or more plies GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS® F1exP1yT'6 sheet or GAFGLAS®#80 UltimaT'Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid®20 Smooth,Ruberoid®30 Granule,Ruberoid® EnergyCapTM 30 Granule FR,Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid® Mop Plus Smooth,Ruberoid®Mop Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, ,Ruberoid®Mop Plus Granule, Ruberoid®Mop Plus Granule FR or Ruberoid®EnergyCapTM Mop Plus Granule FR fully adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCapT' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: -45 psf. (See General Limitation#9) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 40 of 67 Membrane Type: APP/SBS Heat Weld Deck Type 1I: Wood, Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type B(2): Base layer of insulation is mechanically attached to roof deck. Any subsequent layers are then adhered to base layer of insulation. Membrane is subsequently fully or partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutT"Fire Barrier Coating,VersaShield'Fire-Resistant Roof Deck Protection (optional) or Securock'Gypsum-Fiber Roof Board. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM RA Polyiso Insulation Minimum 2.0"thick 1,2,4,5 1:3.2 ft' EnergyGuardTM RN Polyiso Insulation Minimum 1.4"thick 1,2,4,5 1:3 ft' EnergyGuardTM Polyiso Insulation Minimum 1.5"thick 1,2,4, 5 1:2 ft' EnergyGuardTM RA Composite Polyiso Insulation Minimum 1.5"thick 1,2, 4, 5 1:3 ft' EnergyGuardTM Perlite Roof Insulation Minimum 3/4"thick 1,2, 4, 5 1:2 ft' Structodek®High Density Fiber Board Minimum 1"thick 1,2,4,5 1:2 ft' Note: Base layers of insulation shall be mechanically attached using the fastener density listed. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density.Insulation fasteners shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements.Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS°Stratavent"'Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Any of the insulation listed for Base Layer,above. Minimum thickness same as above N/A N/A Structodek®High Density Fiber Board,EnergyGuardTM Perlite Recover Board Minimum 1/2"thick N/A N/A Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. NOA No.: 18-0919.12 MiaMi•�a�e COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 41 of 67 Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS®#80 UltimaTM Base Sheet, GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yT'6,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid Mop Plus Smooth,Ruberoid®20 Smooth,Ruberoid®HW Smooth or Ruberoid®HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.; (See General Limitation 94). OR GAFGLAS® Stratavent®Perforated Venting Base Sheet loose laid dry (not for use with wood fiber board or perlite top layer insulation). Ply Sheet: (Optional,required when using Ruberoid®20 Smooth) One or more plies GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yTM 6 sheet or GAFGLAS®#80 UltimaTM Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Ruberoid®Torch Smooth, Tri-Ply®APP Smooth Membrane,Ruberoid® Torch Granule, Tri-Ply®APP Granule Cap Sheet, ,Ruberoid®EnergyCap'Torch Granule FR,Ruberoid®Torch Plus Granule or Ruberoid®Torch Plus Granule FR, Ruberoid®EnergyCapTM Torch Plus Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid®HW Plus Granule,Ruberoid®HW Plus Granule FR,Ruberoid®HW Granule FR,Ruberoid®EnergyCapTM HW Plus Granule FR, Ruberoid®HW Granule,Ruberoid®HW Smooth and Ruberoid®HW 25 Smooth applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. l. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: -45 psf. (See General Limitation #9) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 42 of 67 Membrane Type: SBS Deck Type 1I: Wood,Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type C(1): All layer of insulation are mechanically attached to roof deck.Membrane is subsequently fully or partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutT'Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection, (optional) VersaShield® Solo"Fire-Resistant Slip Sheet,DensDeck®Roof Board, SECUROCK®Gypsum-Fiber Roof Board or SECUROCK®Glass-Mat Roof Board. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard'"RA Polyiso Insulation,EnergyGuard'"RN Polyiso Insulation Minimum 1.3"thick N/A N/A EnergyGuard'm Polyiso Insulation Minimum 1.4"thick N/A N/A EnergyGuard'm RA Composite Polyiso Insulation Minimum 1.5"thick N/A N/A EnergyGuard'"'Perlite Roof Insulation Minimum 3/4"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard'"'RA Polyiso Insulation Minimum 2.0"thick 1,2,4,5 1:3.2 ft2 EnergyGuard'm RN Polyiso Insulation Minimum 1.4"thick 1,2,4,5 1:3 ft2 EnergyGuard'm RA Polyiso Insulation,EnergyGuardTM Polyiso Insulation Minimum 1.5"thick 1,2,4,5 1:2 ft2 EnergyGuardT"'RA Composite Polyiso Insulation Minimum 1.5"thick 1,2,4,5 1:3 ft2 EnergyGuardTM Perlite Roof Insulation Minimum 1/4"thick 1,2,4,5 1:2 ft' Structodek®High Density Fiber Board Minimum 1"thick 1,2,4,5 1:2 ft2 NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 43 of 67 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent®Perforated Venting Base Sheet laid dry or a layer of EnergyGuard" Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS®#80 Ultima`"'Base Sheet GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®FlexPly'6,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5, Ruberoid®Mop Plus Smooth or Ruberoid®20 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. If base sheet is applied directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved; (See General Limitation #4). OR GAFGLAS® Stratavent®Perforated Venting Base Sheet loose laid dry(not for use with wood fiber board or perlite top layer insulation). Ply Sheet: (Optional)One or more plies GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exPly'6 or GAFGLAS®#80 Ultima`"'Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid®20 Smooth,Ruberoid®30 Granule,Ruberoid® EnergyCap'M 30 Granule FR,Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid® Mop Plus Smooth,Ruberoid®Mop Granule FR,Ruberoid®Mop Granule, , Ruberoid®Mop Plus Granule,Ruberoid®Mop Plus Granule FR fully adhered in an approved asphalt at an application rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: -45 psf. (See General Limitation 49) NOA No.: 18-0919.12 Miaru•DADe COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 44 of 67 Membrane Type: APP/SBS Heat Weld Deck Type 1I: Wood,Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type C(2): All layer of insulation are mechanically attached to roof deck. Membrane is subsequently fully or partially adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutT"Fire Barrier Coating,VersaShield® Fire-Resistant Roof Deck Protection, (optional) VersaShield® Solo`'Fire-Resistant Slip Sheet,DensDeck®Roof Board, or SECUROCK®Gypsum-Fiber Roof Board, or SECUROCK®Glass-Mat Roof Board. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardT"Polyiso Insulation,EnergyGuard'"RA Polyiso Insulation, EnergyGuardT"RN Polyiso Insulation Minimum 1.3"thick N/A N/A EnergyGuardT"Polyiso Insulation Minimum 1.4"thick N/A N/A EnergyGuardT"RA Composite Polyiso Insulation Minimum 1.5"thick N/A N/A EnergyGuardT"Perlite Roof Insulation,EnergyGuard'"Perlite Recover Board Minimum%"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardT"RA Polyiso Insulation Minimum 2.0"thick 1,2,4,5 1:3.2 ftz EnergyGuard'm RN Polyiso Insulation Minimum 1.4"thick 1,2,4,5 1:3 ft2 EnergyGuard'm Polyiso Insulation Minimum 1.5"thick 1,2,4,5 1:2 ft' EnergyGuard'm RA Composite Polyiso Insulation Minimum 1.5"thick 1,2,4,5 1:3 ft' EnergyGuard'Perlite Roof Insulation Minimum%"thick 1,2,4,5 1:2 ft' StructodeV High Density Fiber Minimum 1"thick 1,2,4,5 1:2 ft' NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 45 of 67 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used,the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent®Perforated Venting Base Sheet laid dry or a layer of EnergyGuard"Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, GAFGLAS® #80 Ultima'Base Sheet, GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS® F1exP1y'm 6,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus Smooth or Ruberoid®20 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. If base sheet is applied directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved; (See General Limitation#4). OR GAFGLAS® Stratavent®Perforated Venting Base Sheet loose laid dry(not for use with wood fiber board or perlite top layer insulation). Ply Sheet: (Optional,required when using Ruberoid®20 Smooth) One or more plies GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exPly'6 or GAFGLAS® #80 Ultima'Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Ruberoid®Torch Smooth, Tri-Ply®APP Smooth Membrane,Ruberoid® Torch Granule, Tri-Ply®APP Granule Cap Sheet, ,Ruberoid®EnergyCap`'Torch Granule FR,Ruberoid®EnergyCap'm Torch Plus Granule FR or Ruberoid®Torch Plus Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid®HW Plus Granule,Ruberoid®HW Plus Granule FR, Ruberoid®HW Granule FR,Ruberoid®EnergyCap'm HW Plus Granule FR, Ruberoid®HW Granule,Ruberoid®HW Smooth and Ruberoid®HW 25 Smooth applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'm Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings`' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: -45 psf. (See General Limitation#9) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 46 of 67 Membrane Type: SBS/SBS Cold Applied Deck Type 11: Wood,Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type D(1): All insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. Fire Barrier: FireOutT"Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck (optional) Protection,VersaShield® Solo'Fire-Resistant Slip Sheet,DensDeck®Roof Board, SECUROCK®Gypsum-Fiber Roof Board or SECUROCK®Glass-Mat Roof Board. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard'"Polyiso Insulation,EnergyGuardT"RA Polyiso Insulation, Structodek®High Density Fiber Board Minimum 1"thick N/A N/A Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, GAFGLAS®#80 UltimaTm Base Sheet, GAFGLAS®Stratavent®Nailable Venting Base Sheet or Ruberoid®20 Smooth applied over the loose laid insulation with 2" side laps mechanically fastened to deck as described below; Fastening Drill-TecT"'#12 Fastener or Drill-TecT'#14 Fastener and Drill-TecT"'3" Steel Option#1: Plate,Drill-TecT'AccuTrac®Flat Plate or Drill-TecT'AccuTrac®Recessed Plate installed through the base sheet and insulation in 3 rows 12"o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12.5"o.c. in the field of the sheet. Fastening Drill-TecT"'#12 Fastener or Drill-TecT'#14 Fastener and Drill-TecT"' 3" Steel Option#2: Plates in 4 rows 12"o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. Fastening Drill-TecT"'#12 Fastener or Drill-TecT'#14 Fastener and Drill-TecT"'3" Steel Option#3: Plate,Drill-TecT'AccuTrac®Flat Plate or Drill-TecT'AccuTrac®Recessed Plate installed through the base sheet and insulation in 4 rows 8"o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9"o.c. in the field of the sheet. Ply Sheet: (Optional)One or more plies GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yTm 6, GAFGLAS®#80 UltimaTm Base Sheet,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus Smooth or Ruberoid® 20 Smooth adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 47 of 67 Membrane: One or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5, Ruberoid®Mop Plus Smooth Ruberoid®Mop Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, ,Ruberoid®Mop Plus Granule,Ruberoid®20 Smooth,Ruberoid®30 Granule,Ruberoid®EnergyCap'm 30 Granule FR,Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR or Ruberoid®Mop Plus Granule FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Or One or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5, Ruberoid®Mop Plus Smooth Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF„Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule,Ruberoid®20 Smooth,Ruberoid®30 Granule,Ruberoid®EnergyCap'm 30 Granule FR,Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR or Ruberoid®Mop Plus Granule FR adhered in MatrixTM 102 SBS Membrane Adhesive at an application rate of 1-2 gal./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'm Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings`' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: —45 psf. (See General Limitation#9) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 48 of 67 Membrane Type: APP/SBS Heat Weld Deck Type 11: Wood,Insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type D(2): All insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck (optional) Protection,VersaShield® Solo`'Fire-Resistant Slip Sheet,DensDeck®Roof Board, SECUROCK®Gypsum-Fiber Roof Board or SECUROCK®Glass-Mat Roof Board. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard'Polyiso Insulation,EnergyGuardTM RA Polyiso Insulation Minimum 1.3"thick N/A N/A StructodeV High Density Fiber Board Minimum 1"thick N/A N/A Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, GAFGLAS®#80 UltimaTM Base Sheet, GAFGLAS® Stratavent®Nailable Venting Base Sheet or Ruberoid®20 Smooth base sheet applied over the loose laid insulation with 2" side laps mechanically fastened to deck as described below; Fastening Drill-TecTM#12 Fastener or Drill-TecTM #14 Fastener or and Drill-TecTM 3" Steel Option#1: Plate,Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac®Recessed Plate installed through the base sheet and insulation in 3 rows 12"o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12.5"o.c. in the field of the sheet. Fastening Drill-TecTM#12 Fastener or Drill-TecTM#14 Fastener or and Drill-TecTM 3" Steel Option#2: Plate,Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac®Recessed Plate installed in 4 rows 12"o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. Fastening Drill-TecTM#12 Fastener or Drill-TecTM#14 Fastener or and Drill-TecTM 3" Steel Option#3: Plate installed through the base sheet and insulation in 4 rows 8"o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9"o.c. in the field of the sheet. Ply Sheet: (Optional) One or more plies GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yTM 6 sheet or GAFGLAS®#80 UltimaTM Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 49 of 67 Membrane: One ply of Ruberoid®Torch Smooth, Tri-Ply® APP Smooth,Ruberoid®Torch Granule, Tri-Ply® APP Granule,Ruberoid®EnergyCap'm Torch Granule FR, Ruberoid®EnergyCap`'Torch Plus Granule FR or Ruberoid®Torch Plus Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid®HW Plus Granule,Ruberoid®HW Plus Granule FR,Ruberoid®HW Granule FR,Ruberoid®EnergyCap'm HW Plus Granule FR, Ruberoid®HW Granule,Ruberoid®HW Smooth and Ruberoid®HW 25 Smooth applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap`' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings'Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: -45 psf. (See General Limitation#9) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 50 of 67 Membrane Type: SBS/SBS Cold Applied Deck Type 1: Wood,Non-insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type E(1): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOutT'Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection, (optional) VersaShield® Solo"Fire-Resistant Slip Sheet,DensDeck®Roof Board, SECUROCK®Gypsum-Fiber Roof Board, or SECUROCK Glass-Mat Roof Board. Base sheet: GAFGLAS®#80 Ultima TM Base Sheet, GAFGLAS® Stratavene Nailable Venting Base Sheet,Ruberoid®20 Smooth,Ruberoid®14W Smooth or Ruberoid®14W 25 Smooth base sheet mechanically fastened to deck as described below: Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yT'6, GAFGLAS® Option#1: #75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yT'6, GAFGLAS® Option#2: #75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM#12 Fastener or Drill-TecTM#14 Fastener and Drill-TecTM 3" Steel Plate,Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac®Recessed Plate installed 12"o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®F1exP1y'6, GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or Option#3: any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4"lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—52.5 psf. See General Limitation#7) Fastening GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base sheets Option#4: attached to deck with Drill-TecTM#12 Fastener or Drill-TecTM#14 Fastener and Drill- TecTM 3" Steel Plate,Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac® Recessed Plate installed 12"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®#80 UltimaT Base Sheet,Ruberoid®20 Smooth,Ruberoid®Mop Option#5: Smooth base sheet attached to deck approved annular ring shank nails and 3" inverted Drill-TecTM 3" Steel Plate at a fastener spacing of 9" o.c. at the 4"lap staggered in two rows 9" in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—60 psf. See General Limitation #7) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 51 of 67 Fastening GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base sheets Option#6: attached to deck with Drill-TecTM#12 Fastener or Drill-TecTM#14 Fastener and Drill- Tec'3" Steel Plate,Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac® Recessed Plate installed 8"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Design Pressure—75 psf. See General Limitation #7) Ply Sheet: (Optional)One or more plies GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1y—6, GAFGLAS®#80 Ultima7 Base Sheet,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus Smooth or Ruberoid®20 Smooth sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5, Ruberoid®Mop Plus Smooth,Ruberoid®Mop Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, ,Ruberoid®Mop Plus Granule, Ruberoid®20 Smooth,Ruberoid®30 Granule,Ruberoid®EnergyCap"30 Granule FR,Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR, or Ruberoid®Mop Plus Granule FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Or One or more plies of Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5, Ruberoid®Mop Plus Smooth,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, ,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule,Ruberoid®20 Smooth,Ruberoid®30 Granule,Ruberoid®EnergyCap"30 Granule FR,Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR, or Ruberoid®Mop Plus Granule FR adhered in MatrixTM 102 SBS Membrane Adhesive at an application rate of 1-2 gal./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 52 of 67 Membrane Type: APP/SBS Heat Weld Deck Type 1: Wood,Non-insulated Deck Description: Min. 19/32"or greater plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type E(2): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck (optional) Protection,VersaShield® Solo`'Fire-Resistant Slip Sheet,DensDeck®Roof Board, SECUROCK®Gypsum-Fiber Roof Board or SECUROCK®Glass-Mat Roof Board. Base sheet: GAFGLAS®#80 UltimaTM Base Sheet, GAFGLAS® Stratavent®Nailable Venting Base Sheet,Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid® Mop Plus Smooth,Ruberoid®20 Smooth,Ruberoid®HW Smooth or Ruberoid® HW 25 Smooth mechanically fastened to deck as described below; Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS®F1exP1yTM 6, Option#1: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—45 psf. See General Limitation #9) Fastening GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet, GAFGLAS F1exP1yTM 6, Option#2: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM#12 Fastener or Drill-TecTM#14 Fastener and Drill-TecTM 3" Steel Plate,Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac®Recessed Plate installed 12"o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12.5"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation#9) Fastening GAFGLAS®F1exP1y`6, GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet Option#3: or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—52.5 psf. See General Limitation #7) Fastening GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base Option#4: sheets attached to deck with Drill-TecTM#12 Fastener or Drill-TecTM#14 Fastener and Drill-TecTM 3" Steel Plate,Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac®Recessed Plate installed 12"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation#9) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 53 of 67 Fastening GAFGLAS®#80 UltimaTm Base Sheet,Ruberoid®20 Smooth,Ruberoid®Mop Option#5: Smooth base sheet attached to deck approved annular ring shank nails and 3" inverted Drill-TecT' 3" Steel Plate at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. Not for use with DensDeck or SECUROCK Fire Barrier (Maximum Design Pressure—60 psf. See General Limitation#7) Fastening GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet or any of above base Option#6: sheets attached to deck with Drill-TecTM#12 Fastener,Drill-TecTM #14 Fastener or Drill-TecTM XHD Fastener and Drill-TecTM 3" Steel Plate,Drill-TecT'AccuTraca Flat Plate or Drill-Tec'AccuTrac®Recessed Plate installed 8"o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Design Pressure—45 psf. See General Limitation#9) Ply Sheet: (Optional except over Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5, Ruberoid®Mop Plus Smooth,Ruberoid®20 Smooth,Ruberoid®HW Smooth or Ruberoid®HW 25 Smooth)One or more plies GAFGLAS®Ply 4, Tri-Ply® Ply 4, or GAFGLAS®F1exP1yTM 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or Ruberoid®Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of Ruberoid®Torch Smooth, Tri-Ply®APP Smooth Membrane, Ruberoid®Torch Granule, Tri-Ply®APP Granule Cap Sheet, ,Ruberoid® EnergyCap'Torch Granule FR,Ruberoid®EnergyCapTM Torch Plus Granule FR, or Ruberoid®Torch Plus Granule FR torch applied according to manufacturer's application instructions. Or One or more plies of Ruberoid®HW Plus Granule,Ruberoid®HW Plus Granule FR,Ruberoid®HW Granule FR,Ruberoid®EnergyCap'HW Plus Granule FR, Ruberoid®HW Granule,Ruberoid®HW Smooth and Ruberoid®HW 25 Smooth applied according to manufacturer's application instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of Approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap' Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 Miaru•aaoe COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 54 of 67 Membrane Type: SBS Deck Type 1I: Wood,Non-Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type E(3): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut`'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo'Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option #1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—60 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option #5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—97.5 psf,See General Limitation#7) Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCap'Mop Plus Granule FR or Ruberoid®EnergyCap'30 Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 55 of 67 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. l. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 56 of 67 Membrane Type: SBS Deck Type 1I: Wood,Non-Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type E(4): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut`'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo"Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavent®Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 Option#1: in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in.wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 Option#2: in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-Tec'#14 Fasteners and Drill-TecT"3 in. Standard Steel Plates,Drill-Tec' Option#3: AccuTrac®Flat Plates or Drill-Tec'3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-Tec'#14 Fasteners and Drill-TecT"3 in. Standard Steel Plates,Drill-Tec' Option#4: AccuTrac®Flat Plates or Drill-Tec'3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—60 psf,See General Limitation #7) Fastening Drill-Tec'#14 Fasteners and Drill-TecT"3 in. Standard Steel Plates,Drill-Tec' Option#5: AccuTrac®Flat Plates or Drill-Tec'3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—97.5 psf,See General Limitation#7) Base Sheet: Two or more plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 Ply Sheet or GAFGLAS® F1exP1yT"6 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 57 of 67 Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCap'Mop Plus Granule FR,Ruberoid®EnergyCapTM 30 Granule FR, GAFGLAS®Mineral- Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS® EnergyCapTM Mineral-Surfaced Cap Sheet fully adhered in an approved asphalt at an application rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 58 of 67 Membrane Type: SBS Deck Type 1I: Wood,Non-Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type E(5): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo"Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavene Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-Teo`'3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-Teo`'#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-Teo`' Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—60 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—97.5 psf,See General Limitation#7) Base Sheet: Install one or more plies of Ruberoid®20 Smooth adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 59 of 67 Membrane: Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR,Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF,Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR,Ruberoid®EnergyCap`'Mop Plus Granule FR or Ruberoid®EnergyCap`'30 Granule FR fully adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. Or GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap`'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatings"Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings'M Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 60 of 67 Membrane Type: SBS Deck Type 1I: Wood,Non-Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type E(6): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo"Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavene Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-Teo`'3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-Teo`'#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-Teo`' Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—60 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—97.5 psf,See General Limitation#7) Base Sheet: Install one or more plies of Ruberoid®Mop Smooth or Ruberoid®Mop Smooth 1.5 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Membrane: Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR or Ruberoid® EnergyCapTM Mop Plus Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 61 of 67 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 62 of 67 Membrane Type: SBS Deck Type 1I: Wood,Non-Insulated Deck Description: Min. 15/32"thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c.max. System Type E(7): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut'Fire Barrier Coating,VersaShield®Fire-Resistant Slip Sheet or (optional) VersaShield® Solo"Fire-Resistant Slip Sheet. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet,Ruberoid®20 Smooth or GAFGLAS® Stratavene Nailable Venting Base Sheet is secured as described below. Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—45 psf,See General Limitation #7) Fastening Miami-Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option#2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in.wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#3: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—52.5 psf,See General Limitation#7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#4: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 12 in. o.c. in the min 4 in.wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure—60 psf,See General Limitation #7) Fastening Drill-TecTM#14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates,Drill-TecTM Option#5: AccuTrac®Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate(Flat)are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure—97.5 psf,See General Limitation#7) Base Sheet: Install one ply of Ruberoid®20 Smooth adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation#4). Ply Sheet: Ruberoid®Mop Smooth or Ruberoid®Mop Smooth 1.5 adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 63 of 67 Membrane: Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet,Intec Flex PRF, Ruberoid®Mop Granule FR,Ruberoid®Mop Plus Granule FR or Ruberoid® EnergyCapTM Mop Plus Granule FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United CoatingsTM Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United CoatingsTM Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United CoatingsTM Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 64 of 67 Membrane Type: SBS Cold Applied Deck Type 1I: Wood,Non-Insulated Deck Description: Min. 19/32" plywood or wood plank secured 6 in. o.c. with#8 wood screws to supports spaced 24 in. o.c. max. System Type E(8): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOut"Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection (optional) or VersaShield® Solo"Fire-Resistant Slip Sheet. Base Sheet: Install one ply of GAFGLAS®#75 Base Sheet, Tri-Ply®#75 Base Sheet, GAFGLAS®#80 Ultima"Base Sheet or GAFGLAS®Stratavene Nailable Venting Base Sheet attached to deck with Drill-Tec"#12 Fasteners and Drill- Tec'3" Steel Plate spaced 8 in. o.c. in the min. 2.0 in. wide side laps and 8 in. o.c in three equally spaced, staggered rows in the field of the sheet. Base Ply: GAFGLAS®F1exPly"6 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. in accordance with manufacturer's instructions. Membrane: One or more plies of Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus Smooth, Ruberoid Mop Granule or Intec Flex PRF adhered in MatrixTM 102 SBS Membrane Adhesive at an application rate of 1.5 gal./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap'm Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings`' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings'Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: -105 psf; (See General Limitation #7) NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 65 of 67 Membrane Type: SBS Deck Type 1I: Wood,Non-Insulated Deck Description: Min. 19/32"thick plywood or wood plank secured 6 in. o.c.with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type E(9): Anchor sheet is mechanically attached to roof deck. (Non-insulated systems) All General and System Limitations shall apply. Fire Barrier: FireOufm Fire Barrier Coating,VersaShield®Fire-Resistant Roof Deck Protection (optional) or VersaShield® Solo`'Fire-Resistant Slip Sheet. Base Sheet: Install one ply of GAFGLAS®#80 UltimaT"Base Sheet attached to deck with 12 ga., 1-1/4"galvanized ring shank nails through 32 ga. 1-5/8"diameter tin tabs as stated below: Fastening Option#1: 8 in. o.c. in the min. 4 in. wide side laps and 8 in. o.c in three staggered rows in the field of the sheet. (Maximum Design Pressure-75 psf,• See General Limitation #7) Fastening Option#2: 9 in. o.c. in the min. 4 in. wide side laps and 9 in. o.c in two staggered rows in the field of the sheet. (Maximum Design Pressure-45 psf,• See General Limitation #9) Base Ply: GAFGLAS®F1exPly'6 adhered in a full mopping of approved asphalt applied (Optional) within the EVT range and at a rate of 20-40 lbs./sq. in accordance with manufacturer's instructions. Membrane: One or more plies of Ruberoid®Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,Ruberoid®Mop Smooth,Ruberoid®Mop 1.5,Ruberoid®Mop Plus Smooth,Ruberoid®Mop Plus Granule,Ruberoid®Mop Plus Granule FR, Ruberoid®EnergyCap"Mop Plus Granule FR,Ruberoid®Mop Granule FR, Ruberoid®30 Granule FR,Ruberoid®30 Plus Granule FR or Ruberoid® EnergyCap'"30 Granule FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or GAFGLAS®EnergyCap"Mineral-Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. TOPCOAT® Surface Seal SB or United Coatings`' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. OR TOPCOAT®MB Plus or United Coatings''Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer)followed by TOPCOAT®Membrane or United Coatings'Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq.per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 66 of 67 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS®Ply 4 and GAFGLAS®F1exPly'6 when used as a mechanically fastened base or anchor sheet. 2. Minimum '/4"DensDeck®Roof Board or Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be Tx T maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8"ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lb£, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,prepared, signed and sealed by a Florida Registered Engineer,Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.Calculations prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I 1 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 18-0919.12 MIAMI•DADE COUNTY Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 67 of 67