HomeMy WebLinkAboutCopy of Product Approval(1) op
Professional Regulation
r�
BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
ba
Product Approval
USER:Public User pr 'aa
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL26581-R2
SECRETARY
Application Type Affirmation
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer APOC,Sub of Gardner-Gibson Inc.
Address/Phone/Email 4161 E. 7th Avenue
Tampa, FL 33605
(813) 248-2101
akhan@gardner-gibson.com
Authorized Signature Amir Khan
akhan@gardner-gibson.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Test Report
Testing Lab PRI Construction Materials Technologies, LLC
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2021
Validated By Locke Bowden P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL26581 R2 COI Certificate of Independence.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
TAS 103 1995
Equivalence of Product Standards
Certified By
Approved Testing Lab
FL26581 R2 Equiv Equivalency Letter.pdf
I affirm that there are no changes in the new Florida Building
Code which affect my product(s)and my product(s)are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity Yes No N/A
Product Approval Method Method 1 Option B
Date Submitted 11/09/2020
Date Validated 11/09/2020
Date Pending FBC Approval
Date Approved 11/18/2020
Summary of Products
FL# Model,Number or Name Description
26581.1 APOC Tuff-Felt 26 Asphalt Saturated Felt underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL26581 R2 II APOC Tuff-felt 26 GGI-207-02-01 ASTM D226
Approved for use outside HVHZ:Yes TII.pdf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A Test Reports
Other: FL26581 R2 TR APOC Tuff-felt 26 GGI-207-02-01 ASTM D226
TII.pdf
26581.2 APOC Tuff-Felt 46 Asphalt Saturated Felt underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL26581 R2 II APOC Tuff-Felt 46 GGI-206-02-01 ASTM D266
Approved for use outside HVHZ:Yes TI.pdf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A Test Reports
Other: FL26581 R2 TR APOC Tuff-Felt 46 GGI-206-02-01 ASTM
D266 TI.pdf
26581.3 FT3 Self-adhering membrane composed of elastic polymers,
bitumen polyester and glass reinforcement.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL26581 R2 II FT3 ASTM D 1970-09.pdf
Approved for use outside HVHZ:Yes FL26581 R2 II FT3 TAS103.pdf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A Test Reports
Other: FL26581 R2 TR FT3 ASTM D 1970-09.pdf
FL26581 R2 TR FT3 TAS103.pdf
26581.4 No. 15 ASTM Asphalt Saturated Felt underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL26581 R2 II No. 15 ASTM GGI-206-02-01 ASTM D226
Approved for use outside HVHZ:Yes Tl.pdf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A Test Reports
Other: FL26581 R2 TR No. 15 ASTM GGI-206-02-01 ASTM D226
Tl.pdf
26581.5 No. 30 ASTM Asphalt Saturated Felt underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL26581 R2 II No. 30 ASTM GGI-207-02-01 ASTM D226
Approved for use outside HVHZ:Yes T2.pdf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A Test Reports
Other: FL26581 R2 TR No. 30 ASTM GGI-207-02-01 ASTM D226
T2.pdf
26581.6 United FGUR10 Asphalt Saturated Felt underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL26581 R2 II United FGUR 10 GGI-206-02-01 D226 Tl.pdf
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC
Impact Resistant: N/A Test Reports
Design Pressure: N/A FL26581 R2 TR United FGUR 10 GGI-206-02-01 D226 Tl.pdf
Other:
26581.7 United FGUR20 Asphalt Saturated Felt underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL26581 R2 II United FGUR 20 GGI-207-02-01 ASTM D266
Approved for use outside HVHZ:Yes Tl.pdf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A Test Reports
Other: FL26581 R2 TR United FGUR 20 GGI-207-02-01 ASTM D266
T2.pdf
26581.8 United FGUR70 Asphalt Saturated Felt underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL26581 R2 II United FGUR 70 GGI-207-02-01 ASTM D226
Approved for use outside HVHZ:Yes T2.pdf
Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: N/A Test Reports
Other: FL26581 R2 TR United FGUR 70 GGI-207-02-01 ASTM D226
T2.pdf
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ® ® lid
Credit Card
Safe
CONSTRUCTION MATERIALS
LABORATORY TEST RESULTS
TECHNOLOGIES
Report for: Gardner Gibson Attention: Matt Mullins
4146 E. Th Avenue
Tampa, FL 33605
Product Name(s): APOC Tuff-Felt 26 Manufacturer: Gardner Gibson
PRI-CMT Project No.: GGI-207-02-01 Source: Gardner Gibson
Date Received: January 31, 2018 Dates Tested: Feb. 26, 2018—Mar. 5, 2018
Purpose: Evaluate APOC Tuff-Felt 26 for compliance with the physical properties of
ASTM D 226 Asphalt-Saturated Felt Used in Roofing and Waterproofing,
Type II.
Test Methods: Testing was completed as described in ASTM D 226-09: Standard
Specification for Asphalt-Saturated Organic Felt Used in Roofing and
Waterproofing. Test methods assigned or referenced include ASTM D 70:
Standard Test Method for Density of Semi-Solid Bituminous Materials
(Pycnometer Method);ASTM D 146: Standard Test Methods for Sampling and
Testing Bitumen-Saturated Felts and Woven Fabrics for Roofing and
Waterproofing; and ASTM D 6136: Standard Test Method for Kerosine
Number of Unsaturated(Dry)Felt by Vacuum Method.
Sampling: Product samples were provided by Gardner Gibson in Tampa, FL
GGI-207-02-01
The test results, opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of
stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced
except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility
nor makes a performance or warranty statement for this material or products and processes containing this material in connection
with this report.
PRI Construction Materials Technologies LLC 6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:malerialstesting@pricmt.com WeloSite:http://www.pjcmt,com
Gardner Gibson
ASTM D 226 for
APOC Tuff-Felt 26
Page 2 of 3
Results: ASTM D 226
MethodProperty Test Result Requirement
Physical Requirements
Breaking Strength (Ibf/in-width)
20 specimens; 1" x 6"x thickness; ASTM D 146
Cond. 2h @ 73.4t3.6°F & 50t5%RH;
Test @ 73.4t3.6°F; Rate=2in/min
Longitudinal (with fiber grain) 69 ? 30 >_40
Transverse (across fiber grain) 32 >_ 15 >_20
Pliability[Pass/Fail]
10 specimens; 1" x 8"x thickness; ASTM D 146 '/%" radius %" radius
Cond. 10-15min in water @ 77t1.8°F;
Test 90°around '/" radius in 2s
Longitudinal (with fiber grain) Pass No Failures No Failures
Transverse (across fiber grain) Pass No Failures No Failures
Loss on Heating (weight%)
2 specimens; 12"x 6"x thickness; ASTM D 146 1 <_4 5 4
Test Cond. 221t57 for 5ht3min
Dimensions and Masses
Width of Roll (in) ASTM D 146 36 36t1/4 36t1/4
Area, min (ft2) ASTM D 146 217 432 216
Moisture at Point of Manufacture (%) ASTM D 146 NT <_4.3 <_4.1
As Received' 1.0 <_4.3 <_4.1
Net Mass of Saturated Felt (lb/100ft2) ASTM D 146 26 ? 11.5 >_26
Mass of Saturant (lb/100ft2) ASTM D 146 15.0 >_6.2 >_ 15.0
Mass Ratio of Saturant to Desaturated Felt ASTM D 226 1.5 >_ 1.2 >_ 1.5
Saturation Efficiency (%) ASTM D 226 71 >_70 •••
Mass of Desaturated Felt(lb/100ft2) ASTM D 146 10.0 >_ 5.2 ? 10.0
Ash (%) ASTM D 146 9.0 <_ 10.0 <_ 10.0
Continued on Following Page
GGI-207-02-01
The test results, opinions,or interpretations are based on the material supplied by the client. This report is for the exclusive use of
stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced
except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility
nor makes a performance or warranty statement for this material or products and processes containing this material in connection
with this report.
PRI Construction Materials Technologies LLC 6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:matedalslesting@pricmt.com WebSite:http:l/www.pdcmt.com
Gardner Gibson
ASTM D 226 for
APOC Tuff-Felt 26
Page 3 of 3
Requirement
• • •• Result
Type I Type
Perforated Felt (in2) ASTM D 226 NA <_0.05
Average Venting Area (%) ASTM D 226 NA ? 0.1
Other
Unrolling @ 50°F and 140°F[Pass/Fail] ASTM D 226 Pass No Damage No Damage
Note(s): 1- Moisture(As Received)was utilized in lieu of Moisture at Point of Manufacture;
NT- Not Tested;
NA- Not Applicable
Statement of Compliance:
The product was tested has demonstrated compliance with the physical requirements of Type II prescribed
in ASTM D 226-09: Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and
Waterproofing.
Signed: Signed: (�
LAG
J son Simt
ns Duc T.Nguyen
tt Florida Registered Professional Engineer
PE No.:65034
Date: ,rh/�, Date:
0
Q,�e9�ao�aata►er""
Report Issue History: ;�JG•'��G E N SF• ���`
4: No 65034
Issue# Date Pages Revision Description (if applica@lq)
Original 03/08/2018 3 NA d
o . :`d! o
s
ate'•• STATE O OR Q1
END OF REPORT
GGI-207-02-01
The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of
stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced
except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility
nor makes a performance or warranty statement for this material or products and processes containing this material in connection
with this report.
PRI Construction Materials Technologies LLC 6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813-621-5840 e-mail:matedalstesting@pdcmt.com WebSite:http://wvAv.pricmt.com