Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 26 Phase 3 Waterstone 2508 AGLN Builder Name: ADAMS HOMES Street: 8311 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 13. 10. Wall Type> l920.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1648.00 ftz b. Frame - Wood, Adjacent R=13.0 272.00 ftz Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types (2603.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ftz 6. Conditioned floor area above grade (ftz) 2523 b. Knee Wall (Vented) R=19.0 80.00 ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(260.4 sqft.) Description Area 12. Ducts R ftz a. U-Factor: Dbl, U=0.33 117.49 ftz a. Sup: Attic, Ret: Main, AH: Main 6 503.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 42.0 SEER:15.00 c. U-Factor: Dbl, U=0.55 51.11 ftz SHGC: SHGCng Area Weighted Average Overhang Depth: 6.950 ft. D 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.323 a. Electric Heat Pump 42.0 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2523.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits Pstat Total Proposed Modified Loads: 67.93 Glass/Floor Area: 0.103 PASS Total Baseline Loads: 68.44 I hereby certify that the plans ications covere this ReVi"N of the plans and 0�1IB;S�9 calculation are in compl' nergy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. rjlii'''• �� ,ti F PREPARED BY: Before construction is completed DATE: 1717_91_9021 fn/inn KPomany this building will be inspected for Cy . ;a. compliance with Section 553.908`- I hereby certify that this building, as designed, is in compliance Florida Statutes. y with the FloridaFEne. OWNER/AG Ei.IT: - BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with. ANSI/RESNET/ICC 380, is not greater than 0.045 Qn for whole house. 7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY ICHFC.KI IST RFPC)RT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 26 Phase 3 Waterstone 2 Bedrooms: 4 User Conditioned Area: 2523 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot Information Lot # 26 Phase3 Block/Subdivision: Waterstone PlatBook: Street: 8311 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce , FL , 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2523 20184 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2523 20184 Yes 5 FLOORS 4 1 Yes Yes Yes # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0 2523 ft2 ---- 0.44 0 0.56 ROOF / V/ # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2821 ftz 630 ftz Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2523 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2523 ftZ 0.11 Wood 80 ftZ 0.11 Wood 7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software . Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int Insul Main 4.1 25 0 8 0 200.0 ftZ 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 57 0 8 0 456.0 ftZ 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ftZ 0 0 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 5 0 8 0 40.0 ftZ 0 0 0.6 0 5 E Exterior Concrete Block - Int Insul Main 4.1 38 3 8 0 306.0 ftZ 0 0 0.6 0 6 - Garage Frame - Wood Main 13 34 0 _ 8 0 272.0 ftZ 0 0.23 0.01 0 7 E Exterior Concrete Block - Int Insul Main 4.1 18 9 8 0 150.0 ftZ 0 0 0.6 0 8 N Exterior Concrete Block - Int Insul Main 4.1 6 6 8 0 52.0 ftZ 0 0 0.6 0 9 S Exterior Concrete Block - Int Insul Main 4.1 5 3 8 0 42.0 ftZ 0 0 0.6 0 DOORS # Ornt Door Type, Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .25 3 6 8 20 ftZ 2 - Wood Main None 25 2 8 6 8 17.8 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftZ 25 ft 0 in 0 ft 10 in Drapes/blinds None 2 E 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftZ 1 ft 4 in 0 ft 10 in None Exterior 5 3 N 1 Vinyl Low-E Double Yes 0.33 0.31 N 7.5 ftZ 6 ft 0 in 0 ft 6 in None None 4 N 1 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ftZ 6 ft 0 in 2 ft 10 in None None 5 N 1 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ftZ 1 ft 4 in 1 ft 0 in None Exterior 5 6 N 1 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft' 1 ft 4 in 1 ft 0 in None Exterior 5 7 E 5 Vinyl Low-E Double Yes 0.55 0.7 N 15.6 ftZ 25 ft 0 in 0 ft 10 in None None 8 E 5 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ftZ 1 ft 4 in 0 ft 10 in None Exterior 5 9 E 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ftZ 1 ft 4 in Oft 10 in None Exterior 5 10 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ftZ 7 ft 2 in 0 ft 4 in None Exterior 5 11 S 3 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftZ 9 ft 10 in 0 ft 10 in None None 12 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ftZ 7 ft 2 in 0 ft 4 in None Exterior 5 13 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ftZ 9 ft 10 in 0 ft 4 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 620 ftZ 620 ftZ 64 ft 8 ft 1 7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM'R405-2020 INPUT RIIMMARY ICHFCKI IRT RFPf1RT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 2354.8 129.19 242.54 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS ---- Supply ---- V # Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 503.2 ft Main 125.8 ft Proposed Qn Main --- cfm 113.5 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat: Y Coolin Jan Feb Mar Heating X Jan X Feb XMar [ Jan [ Feb X Mar Ceiling Fans: Se Apr May rj Junrl APrfMayJun Jul AuSep f Jul ri Au ri [X] A r [ Ma Jun JulAug Se [X Oct Nov Oct H NovDecVentin Oct Nov HD Dec 7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 y FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ 7. Windows" Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 8311 Amalfi Circle, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1648.00 ftZ b. Frame - Wood, Adjacent R=13.0 272.00 ftZ 1 c. N/A R= ftZ 4 d. N/A R= ftZ No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ftZ 2523 b. Knee Wall (Vented) R=19.0 80.00 ftZ Area c. N/A R= ftZ 117.49 ftZ 12. Ducts, location & insulation level R ftZ a. Sup: Attic, Ret: Main, AH: Main 6 503.2 70.92 ftZ 13. Cooling systems kBtu/hr Efficiency 51.11 ftZ a. Central Unit 42.0 SEER:15.00 20.83 ftZ 6.950 ft. 0.323 Area ftZ Insulation Area R=0.0 2523.00 ftZ R= ftZ R= ftZ 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: kBtu/hr Efficiency 42.0 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/21/2021 11:58 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1