HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 26 Phase 3 Waterstone 2508 AGLN
Builder Name: ADAMS HOMES
Street: 8311 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
13.
10. Wall Type> l920.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1648.00 ftz
b. Frame - Wood, Adjacent
R=13.0 272.00 ftz
Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 4
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (2603.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2523.00 ftz
6. Conditioned floor area above grade (ftz) 2523
b. Knee Wall (Vented)
R=19.0 80.00 ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
7. Windows(260.4 sqft.) Description Area
12. Ducts
R ftz
a. U-Factor: Dbl, U=0.33 117.49 ftz
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 51.11 ftz
SHGC: SHGCng
Area Weighted Average Overhang Depth: 6.950 ft.
D
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.323
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2523.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
16. Credits
Pstat
Total Proposed Modified Loads: 67.93
Glass/Floor Area: 0.103
PASS
Total Baseline
Loads: 68.44
I hereby certify that the plans ications covere
this
ReVi"N of the plans and
0�1IB;S�9
calculation are in compl' nergy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
rjlii'''• �� ,ti
F
PREPARED BY:
Before construction is completed
DATE: 1717_91_9021 fn/inn KPomany
this building will be inspected for
Cy
. ;a.
compliance with Section 553.908`-
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
y
with the FloridaFEne.
OWNER/AG Ei.IT: -
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with. ANSI/RESNET/ICC 380, is not greater than 0.045 Qn for whole house.
7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY ICHFC.KI IST RFPC)RT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 26 Phase 3 Waterstone 2 Bedrooms: 4
User Conditioned Area: 2523
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 26 Phase3
Block/Subdivision: Waterstone
PlatBook:
Street: 8311 Amalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2523 20184
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 20184 Yes 5
FLOORS
4 1 Yes Yes Yes
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ft2 ---- 0.44 0 0.56
ROOF
/
V/ #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ftz 630 ftz Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2523 ftZ 0.11 Wood
80 ftZ 0.11 Wood
7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software . Page 2 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar Below
1
N
Exterior
Concrete Block - Int Insul
Main
4.1 25
0
8 0
200.0 ftZ
0
0
0.6
0
2
E
Exterior
Concrete Block - Int Insul
Main
4.1 57
0
8 0
456.0 ftZ
0
0
0.6
0
3
S
Exterior
Concrete Block - Int Insul
Main
4.1 50
3
8 0
402.0 ftZ
0
0
0.6
0
4
SW
Exterior
Concrete Block - Int Insul
Main
4.1 5
0
8 0
40.0 ftZ
0
0
0.6
0
5
E
Exterior
Concrete Block - Int Insul
Main
4.1 38
3
8 0
306.0 ftZ
0
0
0.6
0
6
-
Garage
Frame - Wood
Main
13 34
0 _
8 0
272.0 ftZ
0
0.23
0.01
0
7
E
Exterior
Concrete Block - Int Insul
Main
4.1 18
9
8 0
150.0 ftZ
0
0
0.6
0
8
N
Exterior
Concrete Block - Int Insul
Main
4.1 6
6
8 0
52.0 ftZ
0
0
0.6
0
9
S
Exterior
Concrete Block - Int Insul
Main
4.1 5
3
8 0
42.0 ftZ
0
0
0.6
0
DOORS
#
Ornt
Door Type, Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated
Main
None
.25
3
6 8
20 ftZ
2
-
Wood
Main
None
25
2
8
6 8
17.8 ftZ
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E
2
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ftZ
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
2
E
2
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ftZ
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
N
1
Vinyl Low-E Double
Yes
0.33 0.31
N
7.5 ftZ
6 ft 0 in
0 ft 6 in
None
None
4
N
1
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ftZ
6 ft 0 in
2 ft 10 in
None
None
5
N
1
Vinyl Low-E Double
Yes
0.33 0.21
N
32.4 ftZ
1 ft 4 in
1 ft 0 in
None
Exterior 5
6
N
1
Vinyl Low-E Double
Yes
0.33 0.21
N
38.5 ft'
1 ft 4 in
1 ft 0 in
None
Exterior 5
7
E
5
Vinyl Low-E Double
Yes
0.55 0.7
N
15.6 ftZ
25 ft 0 in
0 ft 10 in
None
None
8
E
5
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ftZ
1 ft 4 in
0 ft 10 in
None
Exterior 5
9
E
5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ftZ
1 ft 4 in
Oft 10 in
None
Exterior 5
10
SW 4
Vinyl Low-E Double
Yes
0.33 0.23
N
12.5 ftZ
7 ft 2 in
0 ft 4 in
None
Exterior 5
11
S
3
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ftZ
9 ft 10 in
0 ft 10 in
None
None
12
S
3
Vinyl Low-E Double
Yes
0.33 0.23
N
16.7 ftZ
7 ft 2 in
0 ft 4 in
None
Exterior 5
13
S
3
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ftZ
9 ft 10 in
0 ft 4 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
620 ftZ 620 ftZ
64 ft
8 ft
1
7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM'R405-2020 INPUT RIIMMARY ICHFCKI IRT RFPf1RT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356
2354.8 129.19 242.54 .1263
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V # Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 113.5 cfm 0.04 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Coolin Jan Feb Mar
Heating X Jan X Feb XMar
[ Jan [ Feb X Mar
Ceiling Fans:
Se
Apr May rj Junrl
APrfMayJun Jul AuSep f
Jul ri
Au ri
[X] A r [ Ma Jun JulAug Se [X
Oct Nov
Oct H
NovDecVentin
Oct Nov
HD
Dec
7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture
Fraction
Space
Default 8 Ibs/s
.ft.
0 ftz
0 ft
0.3
Main
7/21/2021 11:57 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
y
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftZ
7. Windows"
Description
a. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.23
b. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.21
c. U-Factor:
Dbl, U=0.55
SHGC:
SHGC=0.70
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
8311 Amalfi Circle, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1648.00 ftZ
b. Frame - Wood, Adjacent
R=13.0
272.00 ftZ
1
c. N/A
R=
ftZ
4
d. N/A
R=
ftZ
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ftZ
2523
b. Knee Wall (Vented)
R=19.0
80.00 ftZ
Area
c. N/A
R=
ftZ
117.49 ftZ
12. Ducts, location & insulation level
R ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
70.92 ftZ
13. Cooling systems
kBtu/hr
Efficiency
51.11 ftZ
a. Central Unit
42.0 SEER:15.00
20.83 ftZ
6.950 ft.
0.323
Area
ftZ
Insulation Area
R=0.0 2523.00 ftZ
R= ftZ
R= ftZ
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
kBtu/hr Efficiency
42.0 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/21/2021 11:58 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1