HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING. CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 182 Phase 3 Waterstone 1820 CGR
Builder Name: ADAMS HOMES
Street: 5326 Vespera Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Typep120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
b. Frame - Wood, Adjacent
R=13.0 270.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. Under Attic (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(238.9 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 168.74 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: - Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor. Dbl, U=0.33 20.00 ft2
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.215 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 61.89
Glass/Floor Area: 0.131
PASS
Total Baseline Loads: 65.00
I hereby certify that the plans ications covere
Revt of the plans and
OT
this calculation are in comp' n o ' nergy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
�+: fuu �• ::, ,� ;� O
PREPARED BY:
Before construction is completed
DATE: 11fi-OR-901 Winn KennnnnV
this building will be inspected for
compliance with Section 553.908
'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the FloridaZaQrgly Code.G'Orj
yT¢
OWNER/AGENT
BUILDING OFFICIAL:
DATE: `-
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
.envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/8/2021 10:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 182 Phase 3 Waterstone Bedrooms: 4
Address Type: Lot Information
Building Type:
User
Conditioned Area: 1820
Lot # 182-3
Owner Name:
Total Stories: 1
Block/Subdivision: Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street: 5326 Vespera Street
Permit Office:
Cross Ventilation: No
County: St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip: Fort Pierce ,
Family Type:
Detached
FL , 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ftz ---- 0.42 0 0.58
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt Emitt Deck Pitch
#
Type
Materials Area Area Color
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ftZ 456 ftz Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft2 0.11 Wood
2
Under Attic (Vented)
Main 19 Batt
80 ftZ 0.11 Wood
6/8/2021 10:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT R11MMARY rW1=r1C1 IRT 01=anOT
WALLS
Adjacent
To AMA T�4pp1
Space
Cavity Width
Height
Sheathing Framing Solar Belo w
S
Exterior Concrete Block - Int Insul
Main
4.1 59 0
10 0
590.0 ft2
0
0 0.6
0
2 W
Exterior Concrete Block - Int Insul
Main
4.1 20 0
10 0
200.0 ft2
0
0 0.6
0
3 N
Exterior Concrete Block - Int Insul
Main
4.1 66 0
10 0
660.0 ft2
0
0 0.6
0
4 E
Exterior Concrete Block - Int Insul
Main
4.1 40 0
10 0
400.0 ft2
0 0.6
0
5 -
Garage Frame - Wood
Main
13 27 0
10 0
270.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W Insulated
Main
None
.25
3
6 8
20 ft2
2
- Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
S
1 Vinyl Low-E Double
Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
None
2
S
1 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
3
W
2 Vinyl Low-E Double
Yes
0.33 0.31 N
6.7 ft2
9 ft 0 in
0 ft 6 in
None
None
4
W
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
None
5
W
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
None
6
W
2 Vinyl Low-E Double
Yes
0.33 0.31 N
13.3 ft2
9 ft 0 in
2 ft 0 in
None
None
7
N
3 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
8
E
4 Vinyl Low-E Double
Yes
0.55 0.7 N
17.8 ft2
12 ft 0 in
0 ft 6 in
None
None
9
E
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
None
10
E
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
12 ft 0 in
0 ft 6 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49 218.7
.1381
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5 34.6 kBtu/hr
1
sys#1
6/8/2021 10:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT RUMMARY ['.I-IFC_KI IST RFPnPT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V
---- Return ---
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft2
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinH Jan H Feb
Mar
Mar
HX
Apr
Apr
Jul
May riJun
May Jun Jul
Jun ri
f AuSep
X Augrl
Se
f
Q
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan Feb
Mar
[X] Apr [
May Jul
[ Aug
Se
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
Oft
0.3
Main
6/8/2021 10:23 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2
7. Windows-
Description
a. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.23
b. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.21
c. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.31
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average
Overhang Depth:
Area Weighted Average SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
5326 Vespera Street, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
4
d. N/A
No
11. Ceiling Type and insulation level
a. Under Attic (Vented)
1820
b. Under Attic (Vented)
Area
c. N/A
168.74 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
32.38 ft2
13. Cooling systems
20.00 ft2
a. Central Unit
17.78 ft2
4.215 ft.
0.269
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature Date:
Address of New Home:
City/FL Zip:
Insulation Area
R=4.1 1850.00 ft2
R=13.0 270.00 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1820.00 ft2
R=19.0
80.00 ft2
R=
ft2
R ft2
6 364
kBtu/hr
Efficiency
35.0 SEER:16.00
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
*`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/8/2021 10:23 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1