HomeMy WebLinkAboutAPPROVED SmithPVDrawings(1)SITE LOCATION MAP PLAN SHEET DESCRIPTION COVER SHEETPV.0 PV.1 PV.2 PV.3 PV.4 PHOTOVOLTAIC MODULE LAYOUT & ROOF PLAN STRUCTURAL ATTACHMENT DETAILS ELECTRICAL DIAGRAM & SCHEDULES ELECTRICAL NOTES & WARNING LABELS SITE SPECIFICATIONS 160 MPH II B 0 PSF ROOF-MOUNTED (FLUSH) WIND SPEED (Vult) RISK CATEGORY WIND EXPOSURE GROUND SNOW LOAD MOUNTING METHOD GOVERNING CODES & STANDARDS 2020 FLORIDA BUILDING CODE (7TH EDITION) 2020 FLORIDA RESIDENTIAL CODE (7TH EDITION) 2017 NATIONAL ELECTRIC CODE (NFPA 70) UNDERWRITERS LABORATORIES STANDARDS (UL) SEI/ASCE 7-16 SYSTEM DESIGN 15300 W QCELLS 340 W x (45) 10800 W ENPHASE IQ7 x (45) RATED DC POWER PV MODULE RATED AC POWER INVERTER(S) ENERGY STORAGE SYSTEM STORAGE CAPACITY SYSTEM TYPE EXISTING ELECTRICAL SITE LOCATION BILL OF MATERIALS QCELLS 340 W MODULES45 45 ENPHASE IQ7 MICROINVERTERS 2 IRONRIDGE XR-100 RAILS - 17 FT. 4 IRONRIDGE XR-100 RAILS - 14 FT. 20 IRONRIDGE XR-100 RAILS - 11 FT. 6 IRONRIDGE XR-100 SPLICE KITS 23 IRONRIDGE MICROINVERTER MOUNTING KITS 114 IRONRIDGE UFO CLAMPS 48 IRONRIDGE UFO END SLEEVES 48 IRONRIDGE XR-100 END CAPS 92 IRONRIDGE FLASHFOOT OR FLASHFOOT2 MOUNTS 12 GROUND LUGS 45 ENPHASE Q CABLE CONNECTORS 3 ENPHASE 6 FT EXTENSION CABLES 1 NEMA 3R ROOF JUNCTION BOX SMITH RESIDENCE A SOLAR PV SYSTEM IMPROVEMENT FOR: SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL SYSTEM 3 ENPHASE END CAPS ENPHASE ENSEMBLE W/ (2) ENCHARGE 10 10.50 KWH UTILITY GRID INTERACTIVE + ESS 120/240 VAC, 1ϕ 1 ENPHASE ENPOWER SMART SWITCH 2 ENPHASE ENCHARGE 10 STORAGE UNIT DRAWING # SHEET OF DATE DRAWN BY: CHECKED BY: PROJECT:PHOTOVOLTAIC SOLAR ENERGY SYSTEMPROJECT ADDRESS:REC. NO. # SCALE AS NOTED DESIGNER HEREBY EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS PERMISSION AND CONSENT OF THE DESIGNER, NOR ARE THEY TO BEASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BERESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THEDIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.950 SUNSHINE LN, ALTAMONTE SPRINGS, FLWWW.UMASOLAR.COMENGINEERING@UMASOLAR.COMSLROREVDATEBYREMARKDOCUMENT NOT VALID WITHOUT SIGN AND SEAL FL PE #81305 JOHN L. ANTONELLI, P.E. 29127PROJECT NAME:FT. PIERCE, FL 3494933 SOVEREIGN WAY. SMITH RESIDENCE51 JLA JLL 9/22/21 PV.0 M ELECTRIC METER MAIN SERVICE PANELMSP LC LOAD CENTER AC DISCONNECT PLP PROTECTED LOADS PANEL TRANSFER SWITCH INVERTER JUNCTION BOX ICON LEGEND COMBINER PANELCBP ROOF WIND ZONE 3 ROOF OBSTACLE FIRE SETBACK ZONE MOUNTING RAIL MOUNTING POINT CONDUIT EXISTING ROOF NOTES 1. EXISTING ROOF IS ASPHALT SHINGLE ROOFING OVER WOOD DECKING & MINIMUM 2X4 S.Y.P. WOOD TRUSSES. - NOTE: ROOF CONSTRUCTION IS BASED ON INFORMATION PROVIDED TO THE DESIGNER. ALL ROOF PENETRATIONS SHALL BE FLASHED AND/OR SEALED USING APPROVED PRODUCTS & METHODS PER LOCAL GOVERNING CODE. 2. ROOFTOP SOLAR COMPONENTS REPRESENT A GRAVITY LOAD OF 3 PSF. - PV MODULES = 2.5 PSF - MOUNTING EQUIPMENT = 0.25 PSF - MISCELLANEOUS ACCESSORIES = 0.25 PSF 3. EXISTING ROOF IS ASSUMED TO BE DESIGNED FOR A MINIMUM LIVE LOAD OF 20 PSF. PER FBC 1607.12.5.1 ROOF SURFACES COVERED BY SOLAR PV MODULES SHALL BE CONSIDERED INACCESSIBLE AND, THUS, THE LOAD IMPOSED BY THE SOLAR PV MODULES WOULD BE LESS THAN THE LIVE LOAD RATING & ABLE TO SUSTAIN THE ADDITIONAL GRAVITY LOAD IMPOSED BY THE SOLAR PV MODULES AND ASSOCIATED ATTACHMENTS. 4. MODULE LOCATION ON ROOF MAY BE ALTERED IN THE FIELD SO LONG AS EQUIPMENT IS MOUNTED AS SHOWN ON SHEET PV.2. R324.6 ROOF ACCESS AND PATHWAYS EXCEPTIONS: 1. DETACHED, NON-HABITABLE STRUCTURES SHALL NOT BE REQUIRED TO PROVIDE ROOF ACCESS. 2. ROOF ACCESS, PATHWAYS, & SETBACKS NEED NOT BE PROVIDED WHERE THE CODE OFFICIAL HAS DETERMINED THAT ROOFTOP OPERATIONS WILL NOT BE EMPLOYED. 3. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF 2:12 (17% SLOPE) OR LESS. R324.6.1 PATHWAYS 1. (2) OR MORE 36" PATHWAYS ON SEPARATE ROOF PLANES FROM EAVE TO RIDGE. 2. (1) OR MORE 36" PATHWAYS ON ROOF PLANES ADJACENT TO THE STREET OR DRIVEWAY. 3. (1) OR MORE 36" PATHWAYS ON ROOF PLANES WITH PV ARRAYS EITHER ON, ADJACENT TO, OR STRADDLING THE SAME & ADJACENT ROOF PLANES FROM EAVE TO RIDGE. R324.6.2 SETBACK AT RIDGE FOR PV ARRAYS OCCUPYING < 33% OF THE PLAN VIEW TOTAL ROOF AREA, A MIN. 18" CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PV ARRAYS OCCUPYING > 33% OF THE PLAN VIEW TOTAL ROOF AREA, A MIN. 36" CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. R324.6.2.2 EMERGENCY ESCAPE AND RESCUE OPENING PANELS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A MIN. 36" PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. 2020 FRC R324.6 ROOF ACCESS REQUIREMENTS PHOTOVOLTAIC MODULE LAYOUT & ROOF PLAN SCALE: 3 32" = 1'-0" 1 PV.1 N CORNER WIND ZONE. SEE SHEET PV.2 FOR ANCHORING REQUIREMENTS QCELLS 340W MODULE TYP. IRONRIDGE XR100 RAIL, TYP. (2) PER MODULE ROW APPROXIMATE LOCATION OF L-FOOT PENETRATION TO 2'-0" SYP TRUSS. FLASH PER 2020 FBC. SEE SHEET PV.2 FOR DETAILS. APPROXIMATE LOCATION OF (E) ELECTRIC METER APPROXIMATE LOCATION OF (E) MAIN DISTRIBUTION PANEL APPROXIMATE LOCATION OF (N) AC DISCONNECT APPROXIMATE LOCATION OF (N) PV COMBINER PANEL ROOFTOP JUNCTION BOX APPROXIMATE LOCATION FOR WIRE TRANSITION. SEE SHEET PV.3 ROOF LAYOUT NOTES ROOF LAYOUT SHOWN MAY BE ADJUSTED IN THE FIELD BY THE INSTALLER TO ACCOUNT FOR ISSUES CAUSED BY ROOF OBSTACLES, TRUSS ALIGNMENT, OR SHADING. SO LONG AS THE MODULES ARE MOUNTED AND SECURED TO THE ROOF AS SHOWN ON PV.2 THE LAYOUT MAY BE ALTERED AND ALL ROOF ORIENTATIONS MAY BE UTILIZED. M MSP CBP MID BATT BATT PLP APPROXIMATE LOCATION OF (N) ENPHASE ENPOWER MICROGRID INTERCONNECT DEVICE APPROXIMATE LOCATION OF (N) ENPHASE ENCHARGE 10 STORAGE UNIT APPROXIMATE LOCATION OF (N) PROTECTED LOADS PANEL ACCESS PATHWAY PER 2020 FRC R324.6 & 2020 FFPC 24'-6"19'-8"4'-0" 64'-8"6'-6"16'-5"4'-0"64'-5"4'-0"DRAWING # SHEET OF DATE DRAWN BY: CHECKED BY: PROJECT:PHOTOVOLTAIC SOLAR ENERGY SYSTEMPROJECT ADDRESS:REC. NO. # SCALE AS NOTED DESIGNER HEREBY EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS PERMISSION AND CONSENT OF THE DESIGNER, NOR ARE THEY TO BEASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BERESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THEDIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.950 SUNSHINE LN, ALTAMONTE SPRINGS, FLWWW.UMASOLAR.COMENGINEERING@UMASOLAR.COMSLROREVDATEBYREMARKDOCUMENT NOT VALID WITHOUT SIGN AND SEAL FL PE #81305 JOHN L. ANTONELLI, P.E. 29127PROJECT NAME:FT. PIERCE, FL 3494933 SOVEREIGN WAY. SMITH RESIDENCE52 JLA JLL 9/22/21 PV.1 ℄ TRS ℄ TRS ℄ TRS ℄ TRS ℄ TRS ℄ TRS ℄ TRS ℄ TRS ℄ TRS PORTRAIT ORIENTATION LANDSCAPE ORIENTATION (LONG AXIS)** LANDSCAPE ORIENTATION (SHORT AXIS) TYPICAL PHOTOVOLTAIC MODULE MOUNTING PLANS SCALE: 3 16"=1'-0" 2 PV.2'Z''Z''Z''Z''Z''Z'MAX. RAIL SPAN MAX. O.H. MAX. RAIL SPAN MAX. O.H.MAX. RAIL SPANMAX.O.H.NOTES: 1. SEE SCHEDULE THIS SHEET FOR MAXIMUM RAIL SPAN. 2. SEE SCHEDULE THIS SHEET FOR MAX. RAIL OVERHANG. MAX. O.H. IS RAIL SPAN X 0.40. 3. 'Z' IS ALLOWABLE DISTANCE BETWEEN RAIL AND MODULE EDGE PER MODULE MANUFACTURER. ** LONG AXIS MOUNTING NOT ALLOWED FOR ALL MODULES. CHECK MANUFACTURER REQUIREMENTS. 3 PVR TYPICAL PHOTOVOLTAIC MODULE LAYOUT - HIP & GABLE ROOFS - ROOF WIND ZONE PLAN SCALE: N.T.S. 1 PV.2 NOTES: 1. "A" DIMENSION DEFINED PER ASCE 7-16 SHALL BE 4 FT PER FBC 2020 (7TH EDITION) FIGURE R301.2(7). 2. "Θ" DIMENSION IS ROOF PITCH, 7°-27°. 2 PV.2 3e 3r 3r 3e 3e 3r 3r 3e 33 3 3 2r 2e 2n2n 2n2n 1 12e 2r 'A''A''A''A''Θ''A''A''A''A'TYPICAL GABLE ROOF PLAN TYPICAL HIP ROOF PLAN TYPICAL ROOF ELEVATION 2 PV.2 2e 2e 2e 2e 2r1 1 1 PHOTOVOLTAIC MODULE GENERAL NOTES: 1. APPLICABLE CODES & STANDARDS: - 2020 FLORIDA BUILDING CODE (7TH EDITION) - 2020 FLORIDA RESIDENTIAL CODE (7TH EDITION) - ASCE-7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2020 FLORIDA BUILDING CODE (7TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A 5 16" STAINLESS STEEL LAG BOLT IN SOUTHERN YELLOW PINE (SYP) ENGINEERED WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL LAG BOLTS THIS SHEET SHALL BE ASTM A276 TYPE 304 STAINLESS STEEL. 4. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27 ° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT TO EXCEED 30'-0" MEAN ROOF HEIGHT. 5. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2020 FLORIDA RESIDENTIAL CODE (7TH EDITION) OR LOCAL GOVERNING CODE. 6. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. 7. THIS DRAWING COVERS ALL PV MODULES WITH A NOMINAL SIZE OF 39" X 78" OR LESS. 8. ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. - PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES, RESPECTIVELY. - GROUPS ARE MADE UP OF ROOF WIND ZONES WITH IDENTICAL WIND PRESSURES. SEE DETAIL BELOW FOR WIND ZONE LOCATIONS. "---" IN TABLE INDICATE CONDITIONS WHERE INSTALLATION IS NOT ALLOWABLE. - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "B", RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-16 AND 2020 FLORIDA BUILDING CODE. -LAG BOLT DEPTH REQUIRED IN WOOD MEMBER SHALL EXCLUDE ANY ROOF DECKING THICKNESS. EXPOSURE B - RISK CATEGORY II - GABLE ROOF > 7°-27° Vult (MPH) GROUP 1 GROUP 2 GROUP 3 EMBED. DEPTH REQ.1, 2e 2n, 2r, 3e 3r (+)(-) Vasd WIND PRESSURES (PSF) (+)(-)(+)(-) 3"MAXIMUM RAIL SPANS & OVERHANGS SPAN OVERHANG SPAN OVERHANG SPAN OVERHANG EXPOSURE B - RISK CATEGORY II - HIP ROOF > 7°-27° Vult (MPH) GROUP 1 GROUP 2 GROUP 3 EMBED. DEPTH REQ.1 2e, 2r 3 (+)(-) Vasd WIND PRESSURES (PSF) (+)(-)(+)(-) 160 3"SPAN OVERHANG SPAN OVERHANG SPAN OVERHANG 160 6'-0" O.C.2'-4" O.C.6'-0" O.C.2'-4" O.C.4'-0" O.C.1'-7" O.C. 16.0 16.0 16.0-37.5 -56.2 -67.4 6'-0" O.C.2'-4" O.C.6'-0" O.C.2'-4" O.C.4'-0" O.C.1'-7" O.C. 16.0 16.0 16.0-33.7 -44.9 -48.7 WOOD ROOF TRUSS TYP. WOOD SHEATHING XPHOTOVOLTAIC MODULE TYP. TYPICAL ROOF CONNECTION DETAIL SCALE: 1 1 2"=1'-0" 3 PV.2'Z' (SEE N O T E I N 1 / P V R) 5 16" STAINLESS STEEL LAG BOLT. SEE SCHEDULE FOR EMBEDMENT DEPTH REQUIRED, TYP. EACH CONNECTION ALUM. L-FOOT FASTENED TO RAIL W/ 3/8-16 ST. STL. BONDING BOLT & NUT IRONRIDGE XR1000 OR XR100 ALUM. SOLAR RAIL TYP. REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. ASPHALT SHINGLES OR METAL 5V ROOFING TYP.2" M IN . TYP .2" M IN . TYP . SEE DETAILS THIS SHEET FOR APPROVED MOUNTING HARDWARE 5 16" Ø STAINLESS STEEL THREADED ROD W/ NUT - WASHERS - LOCTITE ALL NUTS, TYP. S.Y.P. BLOCKING - LOCATE BETWEEN TRUSSES AND NAIL WITH 2-16D NAIL PATTERN AT EACH END TO WOOD TRUSS 2X PT S.Y.P. WOOD BLOCKING OR UNISTRUT BETWEEN ADJACENT ROOF TRUSSES OPTIONAL SPANNER CONNECTION DETAILS SCALE: 1 1 2"=1'-0" 5 16" STAINLESS STEEL LAG BOLT. SEE SCHEDULE FOR EMBEDMENT DEPTH REQUIRED, TYP. EACH CONNECTION X2" M IN . TYP .2" M IN . TYP . 4 PV.2 REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. SEE DETAILS THIS SHEET FOR APPROVED MOUNTING HARDWARE IRONRIDGE XR1000 OR XR100 ALUM. SOLAR RAIL, TYP 12" ALUM. INTERNAL SPLICE BAR (ATTACH WITH (4) #12-14x5 8" STAINLESS STEEL STS, TYP.) TYPICAL SOLAR RAIL BEAM SPLICE DETAIL SCALE: 1 1 2"=1'-0" 3 8" 1"1" PV MODULE FRAME IRONRIDGE UFO CLAMP PV MODULE FRAME IRONRIDGE UFO CLAMP IRONRIDGE RAIL MID CLAMP - PLAN MID CLAMP - SIDE END CLAMP - PLAN END CLAMP - SIDE PV MODULE FRAME IRONRIDGE UFO CLAMP IRONRIDGE STOPPER SLEEVE IRONRIDGE RAIL PV MODULE FRAME IRONRIDGE UFO CLAMP IRONRIDGE STOPPER SLEEVE IRONRIDGE RAIL 1'-0" END & MID CLAMP CONNECTION DETAILS SCALE: 1 1 2"=1'-0" #12-14 x 5/8" STAINLESS STEEL SELF-TAPPING SCREW - (4) PER SPLICE APPROVED MOUNTING HARDWARE SCALE: N.T.S. IRONRIDGE FLASHFOOT OR QUICKMOUNT L-MOUNT IRONRIDGE FLASHFOOT 2 DRAWING # SHEET OF DATE DRAWN BY: CHECKED BY: PROJECT:PHOTOVOLTAIC SOLAR ENERGY SYSTEMPROJECT ADDRESS:REC. NO. # SCALE AS NOTED DESIGNER HEREBY EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS PERMISSION AND CONSENT OF THE DESIGNER, NOR ARE THEY TO BEASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BERESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THEDIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.950 SUNSHINE LN, ALTAMONTE SPRINGS, FLWWW.UMASOLAR.COMENGINEERING@UMASOLAR.COMSLROREVDATEBYREMARKDOCUMENT NOT VALID WITHOUT SIGN AND SEAL FL PE #81305 JOHN L. ANTONELLI, P.E. 29127PROJECT NAME:FT. PIERCE, FL 3494933 SOVEREIGN WAY. SMITH RESIDENCE53 JLA JLL 9/22/21 PV.2 NOTES: 1. REFER TO SHEET PV.4 FOR ALL APPLICABLE ELECTRICAL NOTES. 2. SYSTEM MEETS REQUIREMENTS OF NEC 2017 690.12 FOR RAPID SHUTDOWN. INSTALL PER MANUFACTURER INSTRUCTIONS. 3. ALL CONDUCTORS SHALL BE COPPER UNLESS NOTED OTHERWISE. MINIMUM CONDUCTOR SIZES SHOWN THIS SHEET. 4. THIS SHEET IS DIAGRAMMATIC IN NATURE AND MAY NOT DEPICT ALL REQUIRED COMPONENTS OR CIRCUITS AS THEY MAY EXIST. THE PURPOSE OF THIS DIAGRAM IS TO SHOW THE MAJOR POWER SYSTEM COMPONENTS AND CIRCUITS. CONSULT EQUIPMENT MANUFACTURERS' INSTALLATION MANUALS PRIOR TO INSTALLATION AND COMMISSIONING. CIRCUIT TYPE QTY.SIZE (AWG) MIN. CONDUIT SIZE PHASE CONDUCTOR QTY.SIZE (AWG) NEUTRAL CONDUCTOR QTY.SIZE (AWG) GROUND CONDUCTOR MAX. CIRCUIT LENGTH 1 AC ---2/BRANCH #12 1 #6 BARE CU 86' 2 AC 3/4"6 #12 1 #8 86' 3 AC 3/4"2 #6 1 #6 1 #8 120' WIRE & CONDUIT SCHEDULE 1. CONDUCTOR & CONDUIT SIZES SHOWN ARE MINIMUM REQUIRED. LARGER SIZES MAY BE USED. 2. ALL CONDUCTORS SHALL BE THHN OR THWN-2 UNLESS OTHERWISE NOTED. 3. MAXIMUM CIRCUIT LENGTHS ARE BASED ON A MAXIMUM 2% VOLTAGE DROP. BRANCH NO. 1 (15) MODULES & (15) MICROINVERTERS G G L1 L2 L1 L2 L1 L2 L1 L2 #6 AWG SOLID CU EQUIPMENT GROUND CONDUCTOR CONT. RUN TO GROUND LUG ON RACKING SYSTEM. ALL ROOFTOP COMPONENTS BONDED TO RACKING SYSTEM PER NEC 690.43. MICROINVERTERS CONTAIN INTEGRATED EQUIPMENT GROUNDING. 20A/2P G N (N) ENPHASE IQ COMBINER 80 A SOLAR COMBINER PANEL - NEMA 3R ENCLOSURE L1 L2 20A/2P L1 L2 1 2 BRANCH NO. 2 (15) MODULES & (15) MICROINVERTERS ------ ------ (N) JUNCTION BOX NEMA 3R ENCLOSURE 10A/2P L1 L2 ENPHASE ENVOY (FACTORY WIRED)ENPHASE DROP CABLE SYSTEM TERMINATOR CAP INSTALLED ON END OF ENPHASE BUS CABLE SYSTEM ENPHASE BUS CABLE TYP. -+-+-+-+ -+-+-+-+ 20A/2P L1 L2 BRANCH NO. 3 (15) MODULES & (15) MICROINVERTERS -+-+-+-+ ENPHASE IQ7 MICROINVERTER TYP. L1 L2 L1 L2 L2 40A/2P L1 L2 60A/2P L1 L2 40A/2P N G CONTROL & NFT L1 L2 N G (N) ENPHASE EMPOWER 200G SMART SWITCH (MID) SERVICE RATED EQUIPMENT - 200 A MAX INTEGRATED 40 A NFT UL LISTED NEMA 3R ENCLOSURE L1 L2 N G G 3 4 4 AC 3/4"2 1 #8 108' 5 AC 1-1/2"2 #3 1 #3 1 #6 99' (N) MIN. 60 A AC DISCONNECT (LOCKABLE PER NEC 705.22). LOCATE OUTDOOR AS SHOWN ON SHEET PV.1 STORAGE CAPACITY BATTERY INVERTER ENCLOSURE MAX. PV POWER MAX. BATTERY POWER MAX. PASSTHROUGH CURRENT MAX. LOAD OUTPUT CURRENT BATTERY STORAGE SYSTEM: ENPHASE ENSEMBLE ESS (2) ENCHARGE 10 LFP BATTERIES INTEGRATED ENPHASE IQ8X-BAT ((4) PER BATTERY UNIT) NEMA 3R (ENPOWER & ENCHARGE UNITS) 10800 W AC (240 VAC, MAX. 45.00 A BACKFEED TO GRID) 7680 W AC (240 VAC) 200 A (240 VAC, ON GRID) 32.0 A (240 VAC, OFF GRID, ON BATTERY ONLY) 21.0 KWH TOTAL (10.08 KWH USABLE) 100A MAIN BREAKER G L1 L2 N N (N) 150A PROTECTED LOADS PANEL 7 6 G 5 L1 L2 N G L1 L2 (E) MAIN BREAKER (V.I.F.) G L1 L2 N N EXISTING EARTH GROUND GROUNDING ELECTRODE (E) MAIN DISTRIBUTION PANEL (V.I.F.) L2L1 N L2L1 TO UTILITY GRID 120/240 VAC SINGLE PHASEBI-DIRECTIONAL (TYP.) UTILITY KWH METER L1 L2 N L1 L2SUPPLY SIDE TAP COMPLY WITH NEC 705.12(A) L1 L2 G L1L2G L1 L2 G L1L2G L1 L2 G L1L2G ENPHASE ENCHARGE 10 10.5 KWH - 16 A AT 240 VAC 4 L1 L2 G L1L2G L1 L2 G L1L2G L1 L2 G L1L2G ENPHASE ENCHARGE 10 10.5 KWH - 16 A AT 240 VAC NOTE: UP TO (2) ENPHASE ENCHARGE 10 UNITS MAY BE CONNECTED IN SERIES ON A 40 A CIRCUIT. ENPHASE EMPOWER UNIT MAY ACCEPT UP TO (4) ENCHARGE 10 UNITS ON A MAX. 80 A CIRCUIT. L1 L2 DC-SIDE MODEL RATED POWER Voc PHOTOVOLTAIC SYSTEM POWER TABLE MODULE QTY. MANUFACTURER Isc Vmpp Impp 1 1 1 PARALLEL SERIES 1 --- --- 1 1 AC-SIDE CONT. CURRENT FREQUENCY MODULE QTY. MODEL VOLTAGE CONT. POWER MANUFACTURER MAX. BRANCH 1.00 A AC 60 HZ 1 IQ7 240 VAC 240 W ENPHASE 16 PV MODULE DC-INPUT MICROINVERTER 240 VAC 15.00 A AC 60 HZ 15 3600 W --- 20 A --- --- 15 BRANCH NO. 1 QTY.1 BRANCH NO. 2 OCPD RATING --- ** MODULE CHARACTERISTICS AT STC: CELL TEMPERATURE @ 25° C, SPECTRUM AM1.5, IRRADIANCE @ 1000 W/M² 240 VAC 45.00 A AC 60 HZ 45 10800W --- 60 A --- --- 45 HOME RUN 240 VAC 60 HZ --- 20 A --- --- BRANCH NO. 3 15 340 W 40.66 VDC 10.52 ADC 33.94 VDC 10.02 ADC QCELLS DUO BLK-G6 340 W 40.66 VDC 10.52 ADC 33.94 VDC 10.02 ADC 240 VAC 60 HZ 15 --- 20 A --- --- 15.00 A AC 3600 W 15 15.00 A AC 3600 W 15 #8 1 #8 SUPPLY SIDE TAP NOTES: 1. CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC), OR EQUAL APPROVED COMPONENTS. MAKE, MODEL, AND RATING OF INTERCONNECTION SHALL BE EQUAL TO, OR GREATER THAN, OUTPUT RATING OF PV SYSTEM. 2. THE TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS-SECTIONAL AREA OF THE SPACE. NEC 312.8(2). 3. SUPPLY SIDE TAPS ARE NOT PERMISSIBLE ON METER/MAIN COMBINATION PANELS. (N) MIN. 100 A AC FUSED DISCONNECT W/100 A FUSES (LOCKABLE PER NEC 705.22). LOCATE OUTDOOR AS SHOWN ON SHEET PV.1 6 6 AC 2 #3 1 #3 ------99'1-1/2" DRAWING # SHEET OF DATE DRAWN BY: CHECKED BY: PROJECT:PHOTOVOLTAIC SOLAR ENERGY SYSTEMPROJECT ADDRESS:REC. NO. # SCALE AS NOTED DESIGNER HEREBY EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS PERMISSION AND CONSENT OF THE DESIGNER, NOR ARE THEY TO BEASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BERESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THEDIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.950 SUNSHINE LN, ALTAMONTE SPRINGS, FLWWW.UMASOLAR.COMENGINEERING@UMASOLAR.COMSLROREVDATEBYREMARKDOCUMENT NOT VALID WITHOUT SIGN AND SEAL FL PE #81305 JOHN L. ANTONELLI, P.E. 29127PROJECT NAME:FT. PIERCE, FL 3494933 SOVEREIGN WAY. SMITH RESIDENCE54 JLA JLL 9/22/21 PV.3 PV ELECTRICAL NOTES: GENERAL 1. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 2. OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK. 3. EQUIPMENT SHALL BE INSTALLED PER THE 2017 NATIONAL ELECTRICAL CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER REQUIREMENTS, AND PER THE GOVERNING UTILITY COMPANY. 4. METALLIC CONDUIT OR TYPE MC METAL CLAD CABLE SHALL BE USED WITHIN THE BUILDING FOOTPRINT PER NEC 2017 690.31(G). WIRING & CONNECTIONS 1. ALL CONDUCTORS SHALL BE COPPER AND ARE SIZED BASED ON NEC 2017 310. 2. TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A TOTAL VOLTAGE DROP OF 2% OR LESS PER INVERTER MANUFACTURER. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 2017 690.4(B). 4. THE TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS-SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 4. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. 5. FOR LOAD SIDE CONNECTION: GRID-INTERACTIVE PV SYSTEM CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN, OR EQUAL TO, 120% OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12(B)(2)(3)(b). IF EXISTING EQUIPMENT DOES NOT ALLOW FOR THIS A SUPPLY SIDE CONNECTION MAY BE USED PER NEC 705.12(A). 6. FOR SUPPLY SIDE CONNECTION: CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC), OR EQUAL APPROVED COMPONENTS. MAKE, MODEL, AND RATING OF INTERCONNECTION SHALL BE EQUAL TO, OR GREATER THAN, OUTPUT RATING OF PV SYSTEM. 7. ALL OVERCURRENT PROTECTION DEVICES ARE SIZED PER NEC 2017 240.4(B) & 210.19(A)(1). 8. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 2017 300.6 (C)(1) AND 310.10(D). 9. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER NEC 690.56(C). GROUNDING & BONDING 1. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 PARAGRAPH (C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER WIRE. 2. EACH MODULE IS BONDED TO THE MOUNTING SYSTEM USING BONDING CLAMPS. MOUNTING SYSTEM COMPLIES WITH UL 2703. 3. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 2017 250.24(C). 4. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER NEC 250.54. 5. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8 AWG WHEN INSULATED, #6 AWG IF BARE COPPER. 6. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 2017 690.45, 250.120(C), AND 250.122 & BE A MINIMUM OF #10 AWG WHEN NOT EXPOSED TO DAMAGE, AND #6 AWG SHALL BE USED WHEN EXPOSED TO DAMAGE. LABELING 1. ALL WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 2017 NEC ARTICLE 110.21(B). 2. LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT, AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. 3. PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. 4. PER NEC 690.13, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. SIGN SHALL READ “WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS”. 5. PER NEC 2017 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. MICROINVERTER SYSTEMS 1. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH NEC 2017 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 2. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM, NEC 690.13, 690.6. 3. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH NEC 2017 705.12(A) AS PERMITTED BY NEC 230.82(6). 4. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUIT PER NEC 2017 690.6. 5. ALL GROUNDING SHALL COMPLY WITH NEC 2017 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH NEC 250.64. 6. MICROINVERTER BUS CABLE SYSTEM MUST BE A MINIMUM OF 2 IN. ABOVE THE ROOF SURFACE. REQ'D BY: NEC 690.41(B)1 REQ'D BY: NEC 690.4(B)2 REQ'D BY: NEC 690.13(B)3 REQ'D BY: NEC 690.31 REQ'D BY: NEC 705.12(B)(3)4 REQ'D BY: NEC 690.54 6 REQ'D BY: NEC NEC 705.12(B)(2)(3)(b)10 WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED WARNING! ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PHOTOVOLTAIC SYSTEM DISCONNECT AC CURRENT: 45 A VOLTAGE: 240 VAC WARNING! POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE OVERCURRENT DEVICE APPLY TO: JUNCTION BOXES, RACEWAYS, CABLE TRAYS, CONDUIT BODIES WITH AVAILABLE OPENINGS, EVERY 10', WITHIN 1' OF TURNS/PENETRATIONS APPLY TO: DISCONNECTS, AC COMBINER PANELS, OTHER MEANS OF PV SYSTEM DISCONNECTION APPLY TO: AC DISCONNECT SWITCHES APPLY TO: INVERTER(S), IF NOT APPLIED BY MANUFACTURER APPLY TO: ALL BACKFED CIRCUIT BREAKER(S) APPLY TO: ANY/ALL ELECTRICAL PANELS CONNECTED TO MULTIPLE POWER SOURCES SOLAR AC DISCONNECT PHOTOVOLTAIC POWER SOURCE 7 REQ'D BY: NEC 690.4(B) AC COMBINER PANEL ARC FLASH HAZARD 8APPLY TO: REQ'D BY: NEC 110.16, NFPA 70E 9APPLY TO: REQ'D BY: NEC 705.12(B)(2)(3)(c) APPLY TO: AC COMBINER PANEL WARNING! THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OCPD, SHALL NOT EXCEED AMPACITY OF BUSBAR. APPROPRIATE PPE REQUIRED. FAILURE TO COMPLY CAN RESULT IN INJURY OR DEATH. REFER TO NFPA 70E. CAUTION DO NOT INSTALL ADDITIONAL LOADS IN THIS PANEL !! 11 SIGNAGE REQUIREMENTS 1.) RED BACKGROUND W/ WHITE LETTERING, OR: 2.) WHITE BACKGROUND W/ BLACK LETTERING 3.) MIN. 3/8" LETTER HEIGHT 4.) ALL CAPITAL LETTERS 5.) ARIAL OR SIMILAR FONT 6.) WEATHER RESISTANT MATERIAL, PER UL 969 ! ! WARNING REQ'D BY: NEC 690.56(C)(3)5 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM APPLY TO: PV SYSTEM MAIN AC DISCONNECT SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS REQ'D BY: NEC 690.56(C)(1)(a) APPLY TO: PV SYSTEM MAIN AC DISCONNECT 12 APPLY TO: PV SYSTEM MAIN AC DISCONNECT AC COMBINER PANEL, MAIN SERVICE DISCONNECT 60M DRAWING # SHEET OF DATE DRAWN BY: CHECKED BY: PROJECT:PHOTOVOLTAIC SOLAR ENERGY SYSTEMPROJECT ADDRESS:REC. NO. # SCALE AS NOTED DESIGNER HEREBY EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS PERMISSION AND CONSENT OF THE DESIGNER, NOR ARE THEY TO BEASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS: CONTRACTORS SHALL VERIFY AND BERESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THEDIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.950 SUNSHINE LN, ALTAMONTE SPRINGS, FLWWW.UMASOLAR.COMENGINEERING@UMASOLAR.COMSLROREVDATEBYREMARKDOCUMENT NOT VALID WITHOUT SIGN AND SEAL FL PE #81305 JOHN L. ANTONELLI, P.E. 29127PROJECT NAME:FT. PIERCE, FL 3494933 SOVEREIGN WAY. SMITH RESIDENCE55 JLA JLL 9/22/21 PV.4