Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutpermit.paganelli.pdfAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 0 0 21 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division Commercial Residential
2300 Virginia Avenue, Fort Pierce FL 34992
Phone: (772) 462-1553 Fax: (772) 462-1578 CRDG Funding
PERMIT APPLICATION FOR:
PROPOSED IMPROVEMENT LOCATION:
146
Address: Hau
CA r+P_ Wa
Property Tax ID #: 3L� �b 5 oa � ' Lot No.
Site Plan Name:
Project Name: -JO(Ar)n 'raaan
ll�
DETAILED DESCRIPTION OF WORK:
ra f C
New Electrical Meter
•� ton
Second Electrical Meter
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit - check all that apply:
X Mechanical _ Gas Tank — Gas Piping _ Shutters
Electric ^ Plumbing
Total Sq. Ft of Construction:
(Affidavit required)
Sprinklers _ Generator
Sq. Ft. of First Floor:
Block No.
Windows/Doors _ Pond
Roof Pitch
Cost of Construction: $ Ll650 Utilities: _ Sewer _ Septic Building Height:
OWNER/LESSEE:
Name �'�
Addre s: (�
City: L
Zip Code:��
Phone No.
iti"
1 Fax:
> y?-7 ast
State
Mail:
Fill in fee simple Title Holder on next page (if different
from the Owner listed above)
E-
CONTRACTOR:
Name: knOR 6ey1l00MI
Company: � A',C l� fl e_f's
Address: ,6a]4 iM if QMQf PKW � _
City: Miramar State: f=t_
Zip Code: 33013 _ Fax:
Phone No 100. 753 70
E-Mail 0L31 CAlf © CfAe Ck TVIAi i . 01^
State or County License C iAC19 20 WZ
if value of construction is 2500 or more, a RECORDED Notice of Commencement is required.
if value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: Not Applicable MORTGAGE COMPANY: Not Applicable
Name:
Address:
City:
Zip: Phone
State:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
Name:
Address:
City.
Zip:
Phone:
Name: _
Address:
City:
Zip:
Phone:
State:
BONDING COMPANY: Not Applicable
Name: _
Address:
City:
Zip:,
Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made toobtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which conflicts with an applicable Homeowners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Homeowners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property. A Notice of Commencement must be recorded in the public records of St.
Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult
with lender or an attorney before commencing work or recording your Notice of Commencement. 1
ature a wner/jR�r5ee/c_aPtf-actor as Agent for Owner
STATE OF FLORIDA �
COUNTY OF �3 S arr
Sworn to (or affirmed) and subscribed before me of
this L & day of OC3-0i20-'c 2a _by
J
ellt
Name of person making statement,
Personally Known OR Produced_identificationl
Type of Identification PP oel�ced' L-1 C r
t
� I
(Signature of Notary Pe
i
Commission No. b (seal)
11
I
REVIEWS FRONT ZONING
COUNTER REVIEW
DATE
RECEIVED
DATE
COMPLETED
ev
Physical Presence or
4P Notary IERY Sims Florida
LIIIS MIERYTERAN
My CorrrrMsU)n HH 128079
�1 of � ° Expm 03/31=25
Online Notarization
SUPERVISOR � PLANS I VEGETATION SEA TURTLE MANGROVE
REVIEW REVIEW REVIEW REVIEW REVIEW
Certificate
of
Product
Ratings 0
AHRI Certified Reference Number: 201298732
hate : 10-08-2021
Model Status : Production Stopped
Old AHRI Reference Number : 7984193
Ai Type : RCU-A-CB (Split System: Air -Cooled Condensing Unit. Coil with Blower)
Series: GSX14
Outdoor Unit Brand Name : GOODMAN
Outdoor Unit Model Number (Condenser or Single Package) : GSX140301 K`
Indoor Unit Model Number (Evaporator andlor Air Handler) : ARUF31B14A"
Region : Southeast and North (AL. AR, DC, DE FL, GA, HI, KY, LA, MD, MS, NC, OK. SC, TN, TX. VA, AK, CO, CT, ID. IL,
IA, IN, KS, MA, ME, Mi, MN, MO. MT, ND, NE. Ni NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI. WY, U.S.
Territories)
Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions
until June 30, 2016, Beginning Juiy 1. 2016 central air conditioners can only be installed in region(s) for
which they meet the regional efficiency requirement.
The manufacturer of this GOODMAN product is responsible for the rating of this system combination.
Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air -Conditioning
& Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing:
Cooling Capacity (A2) - Single or High Stage (95F), btuh : 28200
SEER: 14,00
EER (A2) - Single or High Stage (95F) : 11.50
t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale: OR new models that are being
marketed but are not yet being produced." Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still
selling or offering for sale.
Ratings that are ac om ante b WA indicate an involuntar re -rate The new ubli h d rating is shpwn along with the reviaus i.e. WAS rating,
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for.
the product(s) listed on this Certificate, AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the productts), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at www,ahridirectory.pig.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and
confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied: disseminated; .. r
entered into a computer database; or otherwise utilized. in any form or manner or by any means, except for the user's individual, AIR-CONDITIONING, HEATING.
personal and confidential reference. & REFRIGERATION INSTITUTE
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www,ahridirectory.org, click on "Verify Certificate" link we make lift better
and enter the AHRI Certified Reference Number and the date on which the certificate was issued, -
which is listed above, and the Certificate No., which is listed at bottom right. CERTIFICATE NO.: 132781712667266478
@2021 Air -Conditioning, Heating, and Refrigeration Institute
RING
El`.4F_E
ENGINEERINGExPRESS.COM 1(666) 396-9919
CORP. OFFICE: 160 RF
12TH AVE SUITE 106,
DELD BEACH. FL 33442
REPORT HOLDER'
GOODMAN MANUFACTURING COMPANY
19001 KERMIL=R ROAD
WALLER, TX 77484, USA
877-254-4729 1 GOODMANMFG.COM
SCOPE OF EVALUATION (compliance with the following codes):
THlS 15 A STRUCTURAL (WIND) PERFORMANCE EVALUATION
OELECTRICAL
MANCE
RATINGS ORCERTIF CATIONS ARE OFFERED FOR RIMPLIED
HEREIN.
This Product Evaluation Report Is beingissued
in " &ac Editions accordance
(th the
&
requirements of the Florida Building Code
2020)) and the 2D1512018 InternationallResidential Code per FBC Section
104.111, FMC 301.15. FBC Building Ch. 16 ASCE-7, FBC Existing Building
sections 707.1, 707.2. FBC Building 1522.2, and FBC Residential M1202.1,
M1301.1, FS 471.025, including Broward County Admintstrative Provisions
107.3.4. This Report is also in accordance with the International Building
Code (2012, 2015, & 2D18). The product noted on this report has been tested
and/or evaluated as Summarized herein.
IN ACCORDANCE WITH THESE CODES EACH OF THESE REPORTS
MUST BEAR THE ORIGINAL SIGNATURE & RAISED
SEAT. OF THE EVALUATING ENGINEER.
SUBSTANTIATING DATA:
Technical Evaluation Report
Te DIVISION: 23 08 OD —COMMISSIONING OF HV
AC
i DOCUMENT CONTAINS (5) PAGES: THE FIRST PAGE MUST BEAR AN
NAL SIGNATURE & SEAL OF THE CERTIFYING PE TO ,E 6) FOR USE
• Product Evaluation Documents
Substantiating documentation has been submitted to provide this TER and is
summarized in the sections below.
• Structural Engineering Calculations
Structural engineering calculations have been prepared which evaluate the
product based on comparative and/or rational analysis to quality the following
design criteria:
• Maximum allowable unit panel wind pressure connection
integrity
• Maximum allowable uplift, sliding, & overturning moment
for ground and roof applications
Calculation summary is included In this TER and appears below.
NOTE- No 33% increase in allowable stress has been used in the design
of this product Microsoft Excel was used to carry out the calculations
present in this report.
INSTALLATION:
The product(s) listed above shall be installed in strict compliance with this
TER & manufacturer -provided mode! specifications.
The product components shall be of the material specified in the
manufacturer -provided product specifications. All screws must be installed in
accordance with the applicable provisions & anchor manufacturer's published
installation instructions.
LIMITATIONS & CONDITIONS OF USE:
Use of this product shall be in strict accordance with this TER as noted herein.
See final page for complete limitations and conditions Of use
(Subject to Renew July1
OPTIONS:
This evaluation is valid for all GOODMAN models present in the table located
on the final page.
2022 or next CO de cycle c a g
Florida Building Code 6th &
7th Editions (2017 & 2020)
International Building Code
(2012, 2015, & 2018)
NOTE: GRAPHICAL DEPICTIONS IN THIS REPORT ARE FOR
ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER IN APPEARANCE.
UNIT CASING MATERIAL:
26ga galvanized sheet steel ASTM A653 CS cold rolled steels for side covers.
steel ASTM
2298 g galvanized sheetsteelASTM A6535
3 cold rolled steel for bottom base pan
toga g cold rolled steel for top panel Removable
Sop 8r side covers secured with #10-12 sheet metal screws.
Knockouts provided for utility $ control connections.
INSTALLATION:
Shall follow manufacturer specifications as well as the information provided herein.
STRUCTURAL PERFORMANCE:
Models referenced herein are subject to the following design limitations:
Maximum Rated Wind Pressures:
± 119 psf Lateral, 94 psf Uplift
- Required design wind pressures shall he determined according to the design
pressure guide provided in the appendix or on a site -specific basis in accordance
with ASCE 7 and applicable sections of the building code(s) being referenced in
accordance with ASD methodology.
- Required design pressures shall be less than or equal to the maximum pressures
listed herein. all
-'Maximum Rated Wind Pressures indicate the maximum icato
pressures
sh t See WAS
listed herein are approved for Valid for at -grade and rooftop app
limitations herein.
Valid for use inside and outside the High -Velocity Hurricane Zone (HVHZ).
Site -specific wind analysis may produce alternate limitations provided maximum
rated wind pressures stated herein are not exceeded.
VISIT ECALC.10134290
FOR ENGINEER CERTIFIED ORIGINALS
& MORE INFORMATION ABOUT THIS DOCUMENT
OR SCAN THIS CIR CODE ❑
VISIT E VGIFOR
I! EERINCEXPRESS G0f"-STORE `
ADDITIONAL PLANS, REPORTS & RESOURCES
ORIGINAL SIGNATURE AND RAISED SEAL
C)4kQF6}TALSEALR_EQ1JLFTD TO BE VALID #'ER CODE-
ATTENTION
S r)_PC1 COpies not to
be used to obtain
Frank Bennardo, PE, SECB 0 if Checked, Certifying
ENGINEERING ExPRESS® Engineer and PE #
FL PE #0046549 FLCA #9885 Appear Above
DIGITAL SEAL NOTICE: IF THIS DOCUMENT IS DIGITALLY SIGNED, THIS SHEET IS PART OF A
DIGITALLY SIGNED FILE. IT SHALL REMAIN IN DIGITAL FORMAT, SHALL BF VERIFIED By
ELECTRONIC MEANS, & PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED. VISIT ECALC I_010, TO LEARN MORE
PRINTED DOCUMENT NOTICE: IF THIS DOCUMENT IS PRINTED & DOES NOT CONTAIN AN
ENGINEERS ORIGINAL SIGNATURE & SEAL, THIS DOCUMENT IS VOID & NOT VALID FOR
USE. PHOTOCOPIES ARE NOT PERMITTED FOR USE.
FINISH:
Copyright O Engineering Expresso All Rights Reserved
Baked enamel.
ndent san, firm or corporatlon approved by the bUild,N cf jc:.al, who is competent and exper,enced in the appl :,ahoy
The FBC 7"r' Edition 420201 defines APPROVED SOURCE (Sect,on 202) as 'An inoepE PW lens re remenis as defined n the FRC and ran seal ire;r work EngIneermg Expres0'
of eng�neenng prmpples to materials methods or syslems analyses." Engx,eer,ng Expressc professiorals meet the comps y Q��
is re4ularly engaged m eond�cUng and InM-cIng en4l ng evaluamns of s'ngle�iemen[ and }ulproale Gwkdrng sySt®ins.
GOODMAN SPLIT SYSTEMS
Engineering
TER-20-34290
SECTION 2 PRODUCT INSTALLATION
Condenser Unit 11
Opposite side
similar
Roof or ground
structure I substrate
(concrete, steel, see
schedule below)
TIE -DOWN CLIP
(GROUND APPLICATION)
ASTM A653 G60 galvanized cold rolled
steel 0.072" thick for all cabinets tied TIE -DOWN CLIP
down at ground (Goodman Bracket); (GROUND AND ROOF APPLICATION)
fasten cabinet using (2) anchors per clip
Tie -down clips. See from Anchor to Host Structure Schedule
tables below for Miami Teeh CUTt7 1" wide and any
specifications Table. Clip integrates into base pan slot. length ASTM A653 galvanized steel
0.07" thick for all cabinets tied down to
roof structure; fasten clip to structure
using anchor from Anchor Schedule to
d2#10x112"
Tie
-Down Strap
& Clip
Schedule
Host Structure Table an ( )
SS 410 self -drilling screw to fasten Clip
Tie
to unit base pan. See Tie -down Strap a
Unit
Max
UPq'd?Qt7y
M7�Fte
rap
Minimum
Down
Tie-d)wn Strap Clip Schedule Table for clip amount.
Model
Lateral
WILL (Ibsj
Clips
g, Clip Tv�: Hurricane kit #DGACUTd36K
pressure
Pressure
Needed
{for roof applications)
50 psf
39 psf
NO
N/A
N/A
4
Working Load Limit (I/VLL) is strap's manufacturer -specified per strap.
Cabinet
A minimum strap width of 1" is required for all cabinets.
be adequate to fit SMS within base pan height.
106 psf
84 psf
YE 5
2
300
8
Al
Clips heights shall
119 psf
94 psf
YES
2
400
8
Verify height on site.
Clips should be placed at center on each side and equaliy spaced, for
50 psf
39 psf
NO
N/A
N/A
4
ground mounted condition.
106 psf
84 psf
YES
2
400
8
Cabinet
See details in page 3, for roof mounted condition.
Bl, 62
Note: (ValStraApin
1. Tie -down straps shall be wrapped around unit and roof stand rail,
and shall be tightened using the buckle, Provide two straps per unit.
119 psf
94 psf
YES
2
400
8
50 psf
39 psf
NO
N/A
N/A
4
Cabinet
2. Strap material shall be either high strength webbing and shall be
500
8
Cl to
106 psf
84 psf
YES
2
compliant for exterior grade use if they contain plastic components.
119
94
YES
2
600
8
C6
per FBC chapter 26. Or 1" wide 22ga ASTM A653 steel strap
psf
psf
secured with (2) #14 SS sms to the bottom of the stand rail.
50 psf
39 psf
NO
N/A
NIA
4
3. For 200 MPH Non-HVHZ, use (2) metal straps, up to 56' MRH
Cabinet
D1 to
Exposure C.
106 psf
84 psf
YES
2
600
8
119 psf
94 psf
YES
2
600
8
D6
Anchor to Host Structure Schedule
Max
Max
1/8 Min
1/8" Min
Unit Model
Lateral
Uplift
Concrete
3,OOD psi
A36
6061-T6
Pressure
Pressure
Steel
Aluminum
All Cabinets
50 psf
39 p5f
A
N/A
N/A
Al, B1-2,
CI-6, DI-6
119 psf
94 p5f
N/A
B
B
Uplift
Horizontal Strapping
Unit Model
ssure
Required
All Cabinets
"Inlegrityummary
` psf
NONE
Al, 61-2,Cl-6,
Q1-6
psf
NONE
Anchor Types to Host Structure:
A. -- 1M" Dewalt ULTRACON SS4 Anchor embedded 3"
in 3,000 psi concrete. 2 112" from edge minimum.
B. —1/4" -20 UNC SS 316 bolt min. 1/2" from edges with
nut and 1" OD washer
HA. - No anchors apply. .— ` ,'xuw ca'Nnwuous (ALL
\\ ASTL1 ALM SILLL 51 RAP
qKA: L PAss OVER LIN T To
I RFAV ON OP?OS%Tf SiA-
. ! Al 5-1 7 FRQAt EN*,) STRAP%
SltAL~ ek VECUHLLY
22 GA (U.o244" TK31 rrCNLD StiOG AGiu161
Fuu$o) ►i MIN.) STML
►X HOUSING t1Nrr,'
e
ISOLATOR PADS OEYOND.
MIN. 4 PEP UNIT _.
(OPTIOIiALI � z, � u sAf o z v> r
S'I jf w�:; r�+N sitsA
STEE �r
R�4IL 1'lI FA
o RRS10L OFIRr° v
IN ALL CONDITIONS IT 15 THE RESPONSIBILITY OF THE PERMIT HOLDER TO ENSURE THE HOST STRUCTURE IS CAPABLE OF Win I Nti 1 Arvvrnta , na
RATED GRAVITY, LATERAL, AND UPLIFT FORCES BY SITE -SPECIFIC DESIGN. NO WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, IS OFFERED
BY ENGINEERING EXPRESS AS TO THE INTEGRITY OF THE HOST STRUCTURE TO CARRY DESIGN FORCE LOADS INCURRED BY THIS Page 2 of 5
CORP OFC: 16o SW 12TH AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442
(954) 354-06601(866) 396-9999jENGINEERINGEXPRESS.GOM`TEAM@ENGINEERINGEXPRESS.COM
rOODMAN SPLIT SYSTEMS
Engineering - - I TER-20-34290
STRAP AND CLIP LAYOUT ROOF INSTALLATIONS
MECHANICAL
UNIT
UNIT SPRE
---STANt) SPREAp�^—�
MECHANICAL UNIT ROOF MOUNTED
PLAN VIEW
TIE-DOW I
PER SCHE
SPACED A
tR
I 3"X2"XS/8" ALUMINUM ANGLE SHALL BE 6061•T6 AND SHALL OVERHANG 9"
MAXIM UN FROM STAND RAIL PER SIDE.
2. CONDENSER SHALL REST ON TOP OF THE STAND RAILS.
S. CUPS MAY NOT COINCIDE WITH RAIL BELOW, ATTACHED ANGLE USING (2)'4'
THRUBOLT W/ NUT AND 1.0 OD WASHER.
4. TIE -DOWN CLIPS FOR CABINETS EQUAL OR SMAtLER THAN 2(3" WIDE SHALL 8E
LOCATED 1" FROM EDGE MIN.
MECHANICAL
�J�ACT
DOWN CLIP PER
EDULE, SPACED
7 ti SEE NOTE 4
l2I M10 Sf
PER CLIP,
TYP,
4" 3"X2" 1/8" ALUMINUM
GLE, TYP.ATTACHED ,
LS USING 12) Y."
STAN AIL A 11311 THRUBOLT WI
(B ARAT ND I" OD WASHER
TIFI
MECHANICAL UNIT TIE -DOWN DETAIL
(SECTION C-C')
MIN, SEE NOTE 4
YP.
STEEL STRAP
PER SCHEDULE
3•x2-X1fa"
ALUMINUM ANGLE,
SECTION A -A'
TYP. ATTACHED TO
RAILS USING III A'
MA SS 316 THRUBOLT
W/ NUT AND I" OD
WASHER
SEE NOTE 3
I.
I
3"%2"%iJ8" ALUMINUM ANGLE,
TYP- ATTACH En TO RAILS USING (1) 114- DIA THRUBOLT
(2) y." DIA SS 316 THRUBOLTWI SS 316 WITH NUT AND
NUT AND I" OD WASHER WASHER, PER CLIP, TYP
rAND I -RAIL
N SEPARATE
ERTIFiCATiON) MECHANICAL UNIT RESTING ON STAND RAILS
FRONT VIEW (SECTION 8-B')
MECHANICAL UNIT RESTING ON STAND[ -RAIL
STAND RAtLSSECTION A -A' (BY SEPARATE
CERTIFICATION)
(2) R10 SMS PER
CLIP, TYP.
�1
TiE-DOWN CLIP PER
SCHEDULE, SPACED
!
Ill�llllillllllll�llllllll�llll�IIIIIII�II�IIDlllll�fl�11111111lI
Illlll'J�
IIIII
11111111I111�lllllllllllllllll�llllll�ll��lllllll
I� f � �'
I I n11�11111U1i11�1111111r1111i111111I�illi!IOaI
3"x2"X1/$" ALUMINUM MECHANICAL UNIT RESTING ON STAND RAILS
ANGLE, TYP. ATTACHED SIDE VIEW ,
TO RAILS USING 12) Y." NDIe', Installers must ensure that screws used to fasten the tie -down oilps with the unit base pan do rot touch the cod preventing any damage. Ail
DIA SS 316THRUBOLT pieces and instatlation parts per Miami Tech Hurncane kit NDGACUTD36K
WI NUTAND I- OD Page 3 of
WASHER CORP OFC: 160 SW 12" AVENUE SUITE 106, DEERFFLORIDAIELD BEACH, 33442
(954) 354-0660I(866) 396-99991ENGINEERTNGEXPRE55.COM[TEAM @ENGINEERINGEXPRESS.CQM
,--nnr,UAN SPLIT SYSTEMS
neering - , I TER-20-34290
CABINETS S DIMENSIONS
Goodman
W Q
H Cabinet
Model No.
(in.)
(in)
GSX130181
23
25.75 Al
GSX130241
26
27.5 Bl
GSX130301
26
27.5 B1
GSX130361
26
27.5 B1
GSX130421
29
36.25 C3
GSX1- 30�481
29
36.25 C3
GSX130601
29
40 C6
GSX130611
35.5
38.25 D5
GSX140181
26
27.5 B1
GSX146181-M'
23
25 Al
GSX140191
26
27.5 B1
GSX140241
26
27.5 61
GSX140251
26
32.5 B2
GSX140301
29
32.5 C2
GSX140311
29
32.5 C2
GSX140361
29
32.5 C2
GSX140371
29
32.5 C2
GSX140421
29
36.25 C3
GSX14D431
29
36.25 C3
GSX140481
35.5 1
36.25 D1
GSX140601
35.5
36.25 D5
GSX16-181A'
29
32 C2
GSX16'241A*
29
32 C2
GSX161301A'
29
35.75 C3
GSX16'361A'
29
39.5 D6
CSX16'421A'
35.5
35.75 D1
GSX16'481A"
35.5
39.E D6
DSXC160241
29
32.25 C2
DSXC160351
29
38.25 C2
DSXCl00481
35.5
36.25
D1
DSXC160601
355
38.25 1
D3
GSX160181
29
32.25
C2
GSX160241
29
32.25
C2
GSX160301
29
36.25
C3
GSX160361
29
3815
C6
GSX160421
35.5
36.25
D1
GSX160481
35-5
36.25
D3
GSX160601
35.5
38.25
D5
GSX160811
35.5
38.25
D5
GSXC160241
29.25
32.5
C2
GSXC160361
35.75
36.5
D1
GSXC1604el
35.75
37
D3
GSXC160601
35.75
42,25
D6
1
35.75
40
D6
1
35.75
40
06
gGSXG1VG"1
35.75
42.25
D6
1
35.76
42,25
D6
Goodman
Model No.
GSX16031 iA
GS?(160371A
DSAC180361
DSXC180481
DSXC180801
GSZ140181
GSZ140241
GSZ140301
GSZ140361
GSZ140421
GSZ140481
GSZ140491
GSZ140601
VSZ140181
VSZ140241
VSZ140301 1
VSZ140361
VSZ140421
VSZ140481
Cabinet
C3
Di
D3
03
D3
C1
C1
C5
C5
DS
C5
D2
D2
C1
C1
C5
C5
D6
CS
Goodman
Model No.
VSX140601
GSZ160181
GSZ160241
GSZ160301
GSZ160361
GSZ160421
GSZ160481
GSZ160501
GSZC160241
GSZC160361
GSZC160481
GSZC160601
GSZC180241
GSZC190361
GSZC180481
GSZC180601
W I C
(in.)
35.5
29
35.5
35. 5
35.5
29
35.5
35.5
35.5
35.5
35.5
35.5
35.5
35.5
35,5
355
H
(in)
38.25
36.38
34.63
34.63
40
36.38
34.63
40
34.63
40
34.63
40
40
34.63
40
40
Cabinet
D2
C5
D2 l
D2
D6 j`
C5
D2
D6
D2
D6
D2
D6
D6
D3
D5
Dfi
W ! C
(in.)
29
35.5
35.5
35.5
35.5
29
28
29
29
35.5
29
36.5
35.5
29
29
29
29
35.5
29
H
(in)
38.25
36.25
3e.25
38.25
38.25
34-5
34.5
36.25
36.25
39-75
36.25
34.5
34.5
3C5
34.5
3625
36.25
39.75
36.25
DSZC160241
I3SZC160361
29
35,5
36.25
38.25
C4
D3
DSZC160481
35,5
38.25
D3
VSZ140491
VSZ140601
VSX140181
36.5
35.5
26
34.5
34.5
27.5
D2
D2
B1
DSZC160601
35.5
38.25
D3
DSZC180361
35.5
38.25
D3
DSZC180481
35.5
38.25
D3
VSX140191
26
27.5
B1
DSZC180601
35.5
38.25
D3
VSX140241
26
27 5
B1
GSZ14019
29
34.5
C1
VSX140251
26
27.5
at
GSZ14025
29
34.5
C1
VSX140301
29
32.5
C1
GSZ14031
1 35.6
34.63
D2
VSX140311
29
32.5
C1
GSZ14037
35.5
40
D6
VSX1403el
29
32.5
C1
VSX140371
29
32 5
C1
VSX140421
29
36.25
C2
VSX140431
29
36.25
C2
VSX140481
35.5
36.25
D1
H
Note: The model numbers on this page may
be followed by up to two (2) alphanumeric
characters. Those characters will not affect th
structural performance, since they refer to
minodmajor changes not related to the cabine
structure.
Note: Illustration selected for dimensional
purposes
t prig). Remarks Byv I Checked I Date
16-3146 4 f In,t,a1 Issue LAC) i FL6~ r6'16
20--U F[ Update!c 2UF8C CCR ` RIMk '2t2912�
LIMITATIONS 3 CONDITIONS OF USE:ic
Use of this product shall be in strict sccordanee with this TER as noted herein The supporting host structure s"O be designed to resist all superimposed loads IS determined by W a R Site acdcilbasuslby s
for on
may be required t;y the Authority Having JvisdxHost tion. structure conditions which are not acooamled for in this Product's respective anchr;r schedule shall be designed
registered professional engineer No evaluation is offered for the host supporting structure by use of this document, Adjustment faC10r5 noted harem and the eppbcaple codes must be considered. where
applicable.
All supporting components which are perrnermntly rnstared shell be protected agsmat corrosion. contamination, and other such damage al of ernes Fasteners must penetw h the suppodng mamberir such
the full length of ills threaded portion is embedded within the main member_ This evaluation does not offer any evaluation to meet large musk impact debris requirement
s which typically are rtot required for this
type of proFUI of the wind resisting extenor panels. individually meet or exceed then capacity to resist the design wind leads as slatod In the caVculatwns as required by the FBC Oue to the mde[erminate
duct dapli
nature o} these units, distortion and dndnlayn id Yearly
arty ns aCCtons. duringevaluated,equipment
ant with
or after r a named storm, � sutews and
CompOnenlsldips a andwr boles s straps and cablestare to be verified
Wirth sldlv�dual external parts being Y PeC 9 qurPrn
by the FUG contractor. All damaged cabinet components, loose. corroded, broken screws or an iwr bolts snap be replaced to ensure structural integrity for hurricane wind forces. Page 4 of 5
CORP OFC. 160 SW 121'" AVENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442
(954) 354-0660,(866) 396-9999jeNGINEFRINGF-XPRESS.COMITEAM@6NCINEEFIINGEXPRESS.COM
....nniMAu COI IT CVSTFMS
vwwv .r-... -
ineering : . , 1 TER-20-34290
APPENDIX A: DESIGN WIND PRESSURE GUIDE
indicates a design wind pressure that is not
approved for use by this evaluation. Seek
additional engineering or contact this office
for design solutions,
UNIT REACTIONS FROM WIND GUIDE
U
D/ 2 — +
D {'
I
L = s
N f i
= Wt i
I 1
• sd
DIRECTIVE: This design pressure guide is for reference only and shall be approved for
use by the Authority Having Jurisdiction (AHJ). If the design pressures listed in this
guide are not used, required design pressures shall be calculated on a site -specific
basis by others. For site -specific scenarios classified as Exposure Category B, the
required design pressures stated for Exposure Category C in the above guide shall be
used or design pressures shall be calculated separately. For heights and parameters
beyond the above values. consullwith an engineer for a site -specific analysis.
The required ASD design pressures listed in the above guide were calculated based on
the parameters listed below. The project design professional or permitting contractor
shall verify that the site -specific conditions are equal to or less than the design
parameters listed below.
'Note: Per the codes and standards referenced herein, uplift is optional for mechanical
equipment at -grade. At the discretion of the AHJ, uplift may be taken as 0 psf or as the
value listed in the guide.
At -Grade io ft MRH R ire Desi n Pressures:
ASCE 7 "Design Wind Loads: Other Structures"
o Structure Shape = Square, Flat terrain
Height of structure (unit + stand or curb, if used) = 6 ft max.
o Width of unit = 1 ft min., Depth of unit - 1 ft min.
o Uplift Pressure = Lateral Pressure x 1.51 1.9 (if considered)
Rooftop >16 ft MRH11 Require Design Pressures.
o ASCE 7 "Design Wind Loads: Other Structures:
Rooftop Structures and Equipment for Buildings"
o Structure Shape = Square, flat terrain
o z = up to 7 11, where z = height of stand or curb + 1% unit height
c Lateral GCr= I.90; Uplift GC,= 1.50
VISIT ECA -C.10/=DEStGN
FOR HELP DETERMININPARAMETERS AND TO SEE MOR SCAN THE QR CODE 70
DIRECTIVE: This guide is intended for use by a project design professional. Design parameters shall abide all
specifications and limitations staled in this report. Design Professional shall consider all forces, including
seismic and snow loads per governing building codes. Unit reactions obtained from this guide shall be verified
by a registered Professional Engineer. Reactions are applicable for unit -to -host connections only. Sample
calculations are provided below. Design Parameters:
Lateral Wind Pressure, P—lat
Unit Height, H
Unit Width, W
Support Spacing across Depth, sd
Uplift Wind Pressure, P_up
- Unit Depth, D
Unit Weight, Wt
- Support Spacing across Width, sw
Unit R acti n E cations:
Long Side (Width x Height):
Sliding Force, L= Plat x W x H
Uplift Force, U= P_up x W x D
Total Tension per Long Side =
(LxH12+Uxsd12—Wx0.6xsd12)Isd
Short Side (Depth x Height):
Sliding Force, L= P—lat x D x H
Uplift Force. U= Pup x W x D
Total Tension per Short Side =
(LxHl2+Uxsd/2—VAx0.6xsd/2)!sw
Example: A (48' W x 36" D x 42" H), 250 lb net weight unit at wind pressures of 120 psf lateral and 95 psf uplift, on a 24" wide roof stand,
shalt have the following unit reactions.
Long Side width x Hei ht Short Side (Depth x Height):
1. Sliding Force, L= P tat x W x H 1. Sliding Force, L= P lat x D x H
= (120 psf) x (48 in) x (42 in) x (1 in21 144 ft2) = 1680 lb = (120 psf) x (36 in) x (42 in) x (1 in21 144 ft2) = 1260 lb
2. Uplift Force, U = P_up x W x I] 2. Uplift Force, U = P_up x W x O
(95 psf) x (48 in) x (36 in) x (1 in2 / 144 ft2) = 1140 lb = (95 psf) x (48 in) x (36 in) x (1 in21 144 ft2) = 11401b
g. Total Tension per Long Side = 3. Total Tension per Short Side =
=(LxH12+Uxsd12-0x0.6xsd12)!scl =(LxH12+Uxsd12—Wkx0.6xsd12)Isw
_ ( (1680 lb x 4212 in) + (1140 lb x 2412 in) — _ ! (1260 lb x 42/2 in) + (1140 Ito x 2412 in) —
(250 ib x 0.6 x 2412 in) )124 in = 1966 lb (250 lb x 0.6 x 2412 in) )148 in =1046 lb
IN ALL CONDITIONS IT IS THE RESPONSIBILITY OF THE PERMIT HOLDER TO ENSURE THE HOST STRUCTURE IS CAPABLE OF WITHSTANDINIS
G
THE RRATED Y ENGINEERING PRESS AS TO THERINTEGRITYCES BY IOF THE HOST STRICTURE O TE-SPECIFIC DESIGN. NO CARRY DESIGN FORNTY OF ANY GE LOADSSNC RE BY ED OR IMPLIED,
OFFER
UNIT. Page 5 of 5
Copp OFC. 160 SW 12T" AvENUE SUITE 106, DEERFIELD BEACH, FLORIDA 33442