Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 46 Block 1 Waterstone 2030 BGL Builder Name:. ADAMS HOMES Street: 5423 Lugo Street Permit. Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41606.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1398.50 ft2 b. Framer Wood, Adjacent R=13.0 208.25 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2118.0 sqft.) Insulation Area a: Under Attic (Vented) R=30.0 2038.00 ft2 6. Conditioned floor area above grade (ft2) 2038 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(242.4 sqft.) Description Area 12. Ducts R ft2 a, Sup: Attic, Ret: Main, AH:, Main 6 407.6 a. U-Factor: Dbl, U=0.33 139.26 ft2 . SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 55.56 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.29 Area Weighted Average Overhang Depth: 4.378 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.268 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor.(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2038.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 2038.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.119 Total Proposed Modified Loads: 60.21 PASS Total Baseline Loads' 60.82 I hereby certify that the plans ications covere Revi W of the plans: and this calculation are in comp h o ' .: , ergy specifications covered by this Code. -' calculation indicates compliance with the Florida Energy Code.* PREPARED BY: Before construction is completed DATE: 03-95-9021 Winn KPrimany this building will be inspected for a' compliance with Section 553.9108 hereby certify that this building, as designed, is in compliance Florida Statutes. y� " GOD.ig. with the Florida Ener I Code. OWNER/AG BUILDING OFFICIAL: DATE: 7 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with 111403.3.2.1. 1 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th. Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT RUMMARY rHF[:KI IGT RFPnRT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 46 Block 1 Waterstone 20 Bedrooms: 4 User Conditioned Area: 2038 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot Information Lot # 46-1 Block/Subdivision: Waterstone PlatBook: Street: 5423 Lugo Street County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number. Name Area Volume 1 Blockl 2038 17119.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2038 17119.2 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 174.6 ft 0 2038 ftz ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2279 ft2 510 ft2 Medium N 0.85 N 0:85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2038 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2038 ftz 0.11 Wood 80 ftz 0.11 Wood 3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY r..I4FrKI IRT RFPnPT WALLS Ornt Adjacent To Wall Type1 Space Cavity Width Height Sheathing Framing Solar Below SW Exterior Concrete Block - Int Insul Main 4.1 48 0 8 6 408.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 5 2 8 4 43.1 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 13 11 8 4 116.0 ft2 0 0 0.6 0 4 S Exterior Concrete Block- Int Insul Main 4.1 5 2 8 4 43.1 ft2 0 0 0.6 0 5 NE Exterior Concrete Block - Int Insul Main 4.1 51 9 8 6 439.9 ft2 0 0 0.6 0 6 NW Exterior Concrete Block - Int Insul Main 4.1 41 0 8 6 348.5 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 13 24 6 8 6 208.3 111:2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 111:2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 9 ft 0 in Drapes/blinds None 2 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 3 SE 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.3 ft2 2 ft 0 in 0 ft 7 in Drapes/blinds None 4 SE 3 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 5 SE 3 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 2 ft 0 in 0 ft 7 in Drapes/blinds None 6 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 7 NE 5 Vinyl Low-E Double Yes 0.55 0.29 N 17.8 ft2 17 ft 0 in 0 ft 2 in Drapes/blinds None 8 NE 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 9 NW 6 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 10 ft 4 in 0 ft 2 in Drapes/blinds None 10 NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 11 NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 10 It 4 in 0 ft 2 in Drapes/blinds None 12 NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 438 ft2 438 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000373 1997.2 109.57 205.71 .1288 7 3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2026 INPUT RIIMMARY r.141= `KI IRT RIFPnPT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS -- Supply ---- V # Location R-Value Area -- Return ---- Location Area Leakage Type Air CFM 25 Handler TOT CFM25 OUT QN RLF HVAC # Heat Cool 1 Attic 6 407.6 ft Main 101.9 ft Proposed Qn Main --- cfm 81.5 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat: Y Cooling an Feb Mar Heating Jan Feb Mar Ventin Jan Feb X Mar Ceiling Fans: [ j A r [ j Ma rj Jun rj Jul [ ] APr [ ]May JunJul [X] A r [ ] Ma Jun Jul jX] Au Se j ]AuSeP [ ] Aug Se [X] Oct Oct Oct Nov Nov H Nov Dec Dec H Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 r MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 a FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 5423 Lugo Street, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1398.50 ft2 b. Frame - Wood, Adjacent R=13.0 208.25 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. UnderAttic,(Vented) R=30.0 2038.00 ft2 6. Conditioned floor area (ft2) 2038 b. Knee Wall (Vented) R=19.0 80.00 ft2 7. Windows** Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 139.26 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Main,-AH: Main 6 407.6 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 55.56 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ft2 a. Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.29 d. U-Factor. other (see details) 29.78 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.378 ft. a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average SHGC; 0.268 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2038.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature�- Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303..1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/25/2021 2:44 PM EnergyGauge@) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software • Page 1 of 1