HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 46 Block 1 Waterstone 2030 BGL
Builder Name:. ADAMS HOMES
Street: 5423 Lugo Street
Permit. Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41606.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1398.50 ft2
b. Framer Wood, Adjacent
R=13.0 208.25 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2118.0 sqft.)
Insulation Area
a: Under Attic (Vented)
R=30.0 2038.00 ft2
6. Conditioned floor area above grade (ft2) 2038
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(242.4 sqft.) Description Area
12. Ducts
R ft2
a, Sup: Attic, Ret: Main, AH:, Main
6 407.6
a. U-Factor: Dbl, U=0.33 139.26 ft2 .
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 55.56 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.29
Area Weighted Average Overhang Depth: 4.378 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.268
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor.(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2038.0 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 2038.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.119 Total Proposed Modified Loads: 60.21
PASS
Total Baseline Loads' 60.82
I hereby certify that the plans ications covere
Revi W of the plans: and
this calculation are in comp h o ' .: , ergy
specifications covered by this
Code. -'
calculation indicates compliance
with the Florida Energy Code.*
PREPARED BY:
Before construction is completed
DATE: 03-95-9021 Winn KPrimany
this building will be inspected for
a'
compliance with Section 553.9108
hereby certify that this building, as designed, is in compliance
Florida Statutes.
y� "
GOD.ig.
with the Florida Ener I Code.
OWNER/AG
BUILDING OFFICIAL:
DATE: 7
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with 111403.3.2.1.
1 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house.
3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th. Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT RUMMARY rHF[:KI IGT RFPnRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 46 Block 1 Waterstone 20 Bedrooms: 4
User Conditioned Area: 2038
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 46-1
Block/Subdivision: Waterstone
PlatBook:
Street: 5423 Lugo Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number.
Name
Area Volume
1
Blockl
2038 17119.2
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2038 17119.2 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 174.6 ft 0
2038 ftz ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2279 ft2 510 ft2 Medium
N 0.85 N 0:85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2038 ftz N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2038 ftz 0.11 Wood
80 ftz 0.11 Wood
3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY r..I4FrKI IRT RFPnPT
WALLS
Ornt
Adjacent
To Wall Type1
Space
Cavity Width
Height
Sheathing Framing Solar Below
SW Exterior
Concrete Block - Int Insul
Main
4.1 48
0
8 6
408.0 ft2
0
0 0.6
0
2
E
Exterior
Concrete Block - Int Insul
Main
4.1 5
2
8 4
43.1 ft2
0
0 0.6
0
3
SE
Exterior
Concrete Block - Int Insul
Main
4.1 13
11
8 4
116.0 ft2
0
0 0.6
0
4
S
Exterior
Concrete Block- Int Insul
Main
4.1 5
2
8 4
43.1 ft2
0
0 0.6
0
5
NE
Exterior
Concrete Block - Int Insul
Main
4.1 51
9
8 6
439.9 ft2
0
0 0.6
0
6
NW
Exterior
Concrete Block - Int Insul
Main
4.1 41
0
8 6
348.5 ft2
0
0 0.6
0
7
-
Garage
Frame - Wood
Main
13 24
6
8 6
208.3 111:2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SE
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 111:2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SW 1
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
9 ft 0 in
Drapes/blinds
None
2
E 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
3
SE 3
Vinyl Low-E Double
Yes
0.33 0.31
N
5.3 ft2
2 ft 0 in
0 ft 7 in
Drapes/blinds
None
4
SE 3
Vinyl Low-E Double
Yes
0.33 0.21
N
23.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
5
SE 3
Vinyl Low-E Double
Yes
0.33 0.31
N
6.7 ft2
2 ft 0 in
0 ft 7 in
Drapes/blinds
None
6
S 4
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
7
NE 5
Vinyl Low-E Double
Yes
0.55 0.29
N
17.8 ft2
17 ft 0 in
0 ft 2 in
Drapes/blinds
None
8
NE 5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
9
NW 6
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
10 ft 4 in
0 ft 2 in
Drapes/blinds
None
10
NW 6
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
11
NW 6
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
10 It 4 in
0 ft 2 in
Drapes/blinds
None
12
NW 6
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
438 ft2 438 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000373
1997.2 109.57
205.71
.1288
7
3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2026 INPUT RIIMMARY r.141= `KI IRT RIFPnPT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.95 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
-- Supply ----
V # Location R-Value Area
-- Return ----
Location Area Leakage Type
Air CFM 25
Handler TOT
CFM25
OUT QN
RLF
HVAC #
Heat Cool
1 Attic 6 407.6 ft Main
101.9 ft Proposed Qn
Main --- cfm
81.5 cfm 0.04
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling an Feb Mar
Heating Jan Feb Mar
Ventin Jan Feb X Mar
Ceiling Fans:
[ j A r [ j Ma rj Jun rj Jul
[ ] APr [ ]May JunJul
[X] A r [ ] Ma Jun Jul
jX] Au Se
j ]AuSeP
[ ] Aug Se
[X]
Oct
Oct
Oct
Nov
Nov
H Nov
Dec
Dec
H Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6
7 8
9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78 78
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
r
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
3/25/2021 2:44 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
a
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
5423 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1398.50 ft2
b. Frame - Wood, Adjacent
R=13.0
208.25 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. UnderAttic,(Vented)
R=30.0
2038.00 ft2
6. Conditioned floor area (ft2)
2038
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows** Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
139.26 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main,-AH: Main
6 407.6
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
55.56 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.29
d. U-Factor. other (see details)
29.78 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.378 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC;
0.268
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
EF: 0.95
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2038.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature�- Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303..1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/25/2021 2:44 PM EnergyGauge@) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software • Page 1 of 1