Loading...
HomeMy WebLinkAboutREVISION 2, WS LOT 40 - ENERGY CALCS 10.12.21FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-ASHMERE GOODMAN 40 Builder Name: KHOVNANIAN HOMES Street: 5145 ARMINA PL. Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: ASHMERE MODEL LOT 40 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41472.9 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1316.90 ft2 b. Frame - Wood, Adjacent R=11.0 156.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Types (1464.0 sgft.) insulation Area a. Under Attic (Vented) R=30.0 1464.00 fie 6. Conditioned floor area above grade (ft2) 1464 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(146.6 sgft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300 a U-Factor: Dbi, U=0.32 88.38 ft2 SHGC: SHGC=0.30 b. U-Factor: Dbi, U=0.55 42.08 ft2 13. Cooling systems kStu/hr Efficiency SHGC: SHGC=0.34 a. Central Unit 28.0 SEER:16.00 c. U-Factor: Dbl, U=0.27 16.19 ft2 SHGC: SHGC=0.32 Area Weighted Average Overhang Depth: 3.869 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.314 a. Electric Strip Heat 23.0 COP:1.00 8. Skylights Area c. U-Factor.(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1464.D sgft.) Insulation Area EF:0.930 a. Slab -On -Grade Edge Insulation R=0.0 1464.00 ft2 b. Conservation features b, N/A R= ft2 None c. NIA R= ft2 16. Credits Pstat Glass/Floor Area: 0.100 Total Proposed Modified Loads: 47.84 PASS Total Baseline Loads: 48.86 1 hereby certify that the plans and specifications covered by Review of the plans and ST, this calculation are in compliance with t e Florida Ene gy specifications covered by this IV' Code. calculation indicates compliance`,„ with the Florida Energy Code. ars;,+'-: -_:_.• „ O PREPARED BY: Before construction is completed"' DATE: this building will be inspected for - " compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes, with the Florida Energy Code. ob OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/8/2021 8:11 PM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-ASHMERE GOODMA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1464 Lot # Owner Name: ASHMERE MODEL LOT 40 Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANIAN HOMES Rotate Angle: 0 Street: 5145 ARMINA PL. Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp 1/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1464 12883.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BED 2 141 1240.8 No 1 3 1 No Yes Yes 2 HALL BATH 63 554 No 0 1 No Yes Yes 3 FOYER 120 1056 No 0 1 No Yes Yes 4 LAUNDRY 64 563 No 0 1 No Yes Yes 5 BED 3 143 1258 No 1 1 No Yes Yes 6 KIT DIN GIRT RM 576 5069 No 0 1 No Yes Yes 7 PANTRY 35 308 No 0 1 No Yes Yes 8 MAST SUITE 182 1602 No 2 1 No Yes Yes 9 M BATH 90 792 No 0 1 No Yes Yes 10 WIC MAST 50 440 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 2 32.5 ft 0 141 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio HALL BATH 9 ft 0 63 ft2 ---_ 1 0 0 3 Slab -On -Grade Edge Insulatio FOYER 6 ft 0 120 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio LAUNDRY 7.5 ft 0 64 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio BED 3 24 ft 0 143 ft2 --__ 0 1 0 6 Slab -On -Grade Edge Insulatio KIT DIN GRT RM 45 ft 0 576 ft2 ---- 0.25 0.75 0 7 Slab -On -Grade Edge Insulatio PANTRY 1 ft 0 35 fie ---- 1 0 0 10/8/2021 8:11 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT RUMM,ARY ['.HFr-Kl IAT RFPnRT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio MAST SUITE 26.5 ft 0 182 ft2 _--- 0 1 0 9 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 90 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio WIC MAST 5 ft 0 50 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1586 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1464 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 2 30 Blown 141 ft2 0.1 Wood 2 Under Attic (Vented) HALL BATH 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) FOYER 30 Blown 120 ft2 0.1 Wood 4 Under Attic (Vented) LAUNDRY 30 Blown 64 ft2 0.1 Wood 5 Under Attic (Vented) BED 3 30 Blown 143 ft2 0.1 Wood 6 Under Attic (Vented) KIT DIN GIRT RM 30 Blown 576 ft2 0.1 Wood 7 Under Attic (Vented) PANTRY 30 Blown 35 ft2 0.1 Wood 8 Under Attic (Vented) MAST SUITE 30 Blown 182 ft2 0.1 Wood 9 Under Attic (Vented) M BATH 30 Blown 90 ft2 0.1 Wood 10 Under Attic (Vented) WIC MAST 30 Blown 50 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Et In Height Ff In Aren Sheathing Framing Solar - Below 0 t S Exterior Concrete Block - Int Insul BEd 2 4A 6 9 9 4 63.0 ft2 0 0 0.5 0 2 E Exterior Concrete Block - Int Insul BED 2 4.1 10 8 9 4 99.6 ft2 0 0 0.5 0 3 N Exterior Concrete Block - Int Insul BED 2 4,1 12 7 10 0 125.8 ft2 0 0 0.5 0 4 N Exterior Concrete Block - Int InsLHALL BATH 4.1 8 1 10 0 80.8 ft2 0 0 0.5 0 5 E Exterior Concrete Block - Int Insul FOYER 4.1 5 10 9 4 54.4 ft2 0 0 0.5 0 6 S Exterior Concrete Block- Int lnsul BE❑ 3 4.1 12 7 9 4 117.4 ft2 0 0 0.5 0 7 N Exterior Concrete Block - Int Ins14IT DIN GRT 4A 21 7 10 0 215.8 ft2 0 0 0.5 0 8 W Exterior Concrete Block - Int lnsKIT DIN GIRT 4.1 10 4 9 4 96.4 ft2 0 0 0.5 0 9 S Exterior Concrete Block - Int InsMAST SUITE 4.1 13 7 9 4 126.8 ft2 0 0 0.5 0 10 W Exterior Concrete Block - Int InsMAST SUITE 4.1 12 2 9 4 113.6 ft2 0 0 0.5 0 11 S Exterior Concrete Block - int Insul M BATH 4.1 8 9 9 4 81.7 ft2 0 0 0.5 0 12 S Exterior Concrete Block - Int InsuWIC MAST 4.1 4 10 9 4 45.1 ft2 0 0 0.5 0 10/8/2021 8:11 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPIIT Al IMMARV rW1=rICI ICT 0PDn0T Ornt Adjacent To Wall WALLS Typia Space Cavity Width Height Sheathing Framing Solar Below 0 13 W 14 W Garage Frame - Wood KIT DIN GIRT 11 18 0 8 Exterior Concrete Block - Int InsI6IT DIN GIRT 4.1 10 4 9 8 156.0 ft2 4 96.4 ft2 0 0 0.5 0 0 0.5 0 0 DOORS # Ornt Door Type Space Storms l!-Value Ft Width Height In Ft In Area 1 2 E E Insulated FOYER Wood FOYER None None .39 3 .39 2 2 6 10 10 6 10 21.6 ft2 19.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 E 2 Metal S 6 Metal N 7 Metal W 8 Metal W 14 Metal W 10 Metal Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes Double (Tinted) Yes 0.27 0.32 N 0.32 0.3 N 0.32 0.3 N 0.32 0.3 N 0.55 0.34 N 0.32 0.3 N 16.2 ft2 1 ft 0 in 16.2 ft2 1 ft 0 in 24.1 ft2 1 ft 0 in 24A ft2 1 ft 0 in 42.1 W 11 ft 0 in 24.1 ft2 1 ft 0 in 1 ft 0 in None 1 ft 0 in None 1 ft 0 in None 1 ft 0 in None 1 ft 0 in None 1 ft 0 in None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 385 ft2 385 ft2 64 ft 8.8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1503 82.46 154.81 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip HeaU None COP:1 23 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 28 kBtulhr 840 cfm 0.71 1 sys#1 10/8/2021 8:11 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPI IT RI IMMARY rNII=rLCI ICT 09=0nDT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- --- Return --- Air CFM 25 CFM25 HVAC # 1/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft2 FOYER 1 ft2 Default Leakage FOYER (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Feb ]] Heating Jan Feb [X] Mar HJan [ 1 ]] -1 Apr jMaX Jul Jun Ju Jun �X� Aug �X� Se X� 0 H �X� Nov Dec Venting Feb [X Mar I ttt��x1JJJ May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 65 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 Oft 0.3 BED 2 Default(8 Ibslsq.ft. ft2 ft 0.3 HALL BATH Default(8 Ibslsq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibslsq.ft. ft2 ft 0.3 BED 3 Default(8 Ibslsq.ft. ft2 ft 0.3 KIT DIN GRT RM Oefault(8 Ibslsq.ft. ft2 ft 0,3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 MAST SUITE Default(8 Ibslsq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/s .ft. ft2 ft 0.3 WIC MAST 10/8/2021 8:11 PM EnergyGauge�D USA 7.0,00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.34 c. U-Factor: Dbl, U=0.27 SHGC: SHGC=0.32 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): NIA SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. NIA c. NIA 5145 ARMINA PL., FORT PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4,1 1316.90 ft2 b. Fr2me -Wood, Adjacent R=11.0 156.00 ft2 1 c. NIA R= ft2 3 d. NIA R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1464.00 f12 1464 b. N/A R= ft2 Area c. NIA R= ft2 88.38 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: FOYER, AH: FOYER 6 300 42.08 ft2 13. Cooling systems kBtulhr Efficiency 16.19 ft2 a. Central Unit 28.0 SEERA6.00 ft2 3.869 ft. 0.314 Area ft2 Insulation Area R=0.0 1464.00 ft2 R= ft2 R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) l certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL ,Zip: kBtufhr Efficiency 23.0 COP:1.00 Cap: 50 gallons EF: 0.93 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. IM12021 8:11 PM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1