Loading...
HomeMy WebLinkAboutREVISION 2, WS LOT 40 - MANJ 10.12.21Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Oct-08 20:56:47 Right-Suite® Universal 2019 19.0.12 RSU08398 Page 1 ...CTS ENERGY\A- MANUAL J\KHOV-ASHMERE GOODMAN.rup Calc = MJ8 Front Door faces: E Job:Project Summary Date:Entire House LINDSTROMBy: Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com Project Information KHOVNANIANFor: LOT 40 ASHMERE MODELNotes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90 Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15 Daily range M Relative humidity %50 Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh15848 Structure Btuh16086 Ducts Btuh2715 Ducts Btuh5018 Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh18563 Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh21104 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average 0Fireplaces Structure Btuh2863 Ducts Btuh1498 Central vent (0 cfm) Btuh0 CoolingHeating (none) 14641464Area (ft²)Equipment latent load Btuh4361 1288312883Volume (ft³) Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh25465 Equiv. AVF (cfm) 4997 Req. total capacity at 0.79 SHR ton2.2 Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade Trade Model 7.5 KW Cond GSX16S301 AHRI ref Coil ASPT37C14 AHRI ref 201785798 Efficiency 100 AFUE Efficiency 16 SEER Heating input kW0 Sensible cooling Btuh22000 Heating output Btuh0 Latent cooling Btuh6000 Temperature rise °F0 Total cooling Btuh28000 Actual air flow cfm1000 Actual air flow cfm1000 Air flow factor cfm/Btuh0.054 Air flow factor cfm/Btuh0.047 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Oct-08 20:56:47 Right-Suite® Universal 2019 19.0.12 RSU08398 Page 1 ...CTS ENERGY\A- MANUAL J\KHOV-ASHMERE GOODMAN.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House LINDSTROMBy: Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name Entire House BED 2 2 Exposed wall 164.5 ft 32.5 ft 3 Room height 8.8 ft 8.8 heat/coolft 4 Room dimensions ft12.0x11.8 5 Room area 1464.0 ft²141.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 423 399 1598 873 126 126 505 276 .GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 24 0 215 337 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 153 116 464 254 99 83 332 182 .GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 16 0 143 753 16 0 143 753 11 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 21 21 229 217 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 432 416 1666 910 63 63 252 138 GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 16 74 143 224 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 302 211 845 462 0 0 0 0 GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 49 0 439 2307 0 0 0 0 GG 1D-h2omd1D-h2omd 0.5500.550 ww 15.4015.40 17.4717.47 42 84 647 734 0 0 0 0 PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 167 147 399 195 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 20 20 218 207 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 ee 0.900.90 1.601.60 1464 1464 1312 2342 141 141 126 226 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1464 165 4555 0 141 33 900 0 6 c) AED excursion 2136 52 Envelope loss/gain 12874 11952 2259 1626 12 a) Infiltration 2973 814 654 179 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 1 230 Appliances/other 2400 0 Subtotal (lines 6 to 13)15848 16086 2912 2035 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 15848 16086 2912 2035 15 Duct loads 17%31%2715 5018 17%31%499 635 Total room load 18563 21104 3411 2670 Air required (cfm)Air required (cfm)1000 1000 184 126 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Oct-08 20:56:47 Right-Suite® Universal 2019 19.0.12 RSU08398 Page 2 ...CTS ENERGY\A- MANUAL J\KHOV-ASHMERE GOODMAN.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House LINDSTROMBy: Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name HALL BATH LAUNDRY 2 Exposed wall 9.0 ft 7.5 ft 3 Room height 8.8 heat/coolft 8.8 heat/coolft 4 Room dimensions ft7.0x9.0 ft8.0x8.0 5 Room area 63.0 ft²64.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 81 81 324 177 0 0 0 0 .GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 0 0 0 0 GG 1D-h2omd1D-h2omd 0.5500.550 ww 15.4015.40 17.4717.47 0 0 0 0 0 0 0 0 PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 0 0 0 0 68 48 130 64 DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 20 20 218 207 CC 16B-30ad16B-30ad 0.0320.032 ee 0.900.90 1.601.60 63 63 56 101 64 64 57 102 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 63 9 249 0 64 8 208 0 6 c) AED excursion -14 -40 Envelope loss/gain 630 264 614 332 12 a) Infiltration 184 50 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 600 Subtotal (lines 6 to 13)814 315 614 932 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 814 315 614 932 15 Duct loads 17%31%139 98 17%31%105 291 Total room load 953 413 719 1223 Air required (cfm)Air required (cfm)51 20 39 58 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Oct-08 20:56:47 Right-Suite® Universal 2019 19.0.12 RSU08398 Page 3 ...CTS ENERGY\A- MANUAL J\KHOV-ASHMERE GOODMAN.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House LINDSTROMBy: Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name BED 3 KIT DIN GRT RM 2 Exposed wall 24.0 ft 51.0 ft 3 Room height 8.8 heat/coolft 8.8 heat/coolft 4 Room dimensions ft11.0x13.0 ft24.0x29.0 5 Room area 143.0 ft²696.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 216 192 769 420 .GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 0 0 0 0 24 0 215 337 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 54 33 132 72 .GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 21 21 229 217 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 117 101 404 221 0 0 0 0 GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 16 16 143 224 0 21 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 189 123 492 269 GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 24 0 215 1130 GG 1D-h2omd1D-h2omd 0.5500.550 ww 15.4015.40 17.4717.47 0 0 0 0 42 42 647 734 PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 99 99 269 132 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 ee 0.900.90 1.601.60 143 143 128 229 696 696 624 1114 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 143 24 665 0 696 51 1412 0 6 c) AED excursion -23 1683 Envelope loss/gain 1609 783 4736 5975 12 a) Infiltration 266 73 1042 285 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 0 0 Appliances/other 0 1800 Subtotal (lines 6 to 13)1875 1086 5777 8061 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1875 1086 5777 8061 15 Duct loads 17%31%321 339 17%31%990 2515 Total room load 2196 1425 6767 10575 Air required (cfm)Air required (cfm)118 68 365 501 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Oct-08 20:56:47 Right-Suite® Universal 2019 19.0.12 RSU08398 Page 4 ...CTS ENERGY\A- MANUAL J\KHOV-ASHMERE GOODMAN.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House LINDSTROMBy: Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name PANTRY MAST SUITE 2 Exposed wall 0 ft 26.5 ft 3 Room height 8.8 heat/coolft 8.8 heat/coolft 4 Room dimensions ft5.0x7.0 ft14.0x13.0 5 Room area 35.0 ft²182.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 126 126 505 276 GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 113 88 352 193 GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 25 0 224 1177 GG 1D-h2omd1D-h2omd 0.5500.550 ww 15.4015.40 17.4717.47 0 0 0 0 0 0 0 0 PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 ee 0.900.90 1.601.60 35 35 31 56 182 182 163 291 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 35 0 0 0 182 27 734 0 6 c) AED excursion -2 505 Envelope loss/gain 31 54 1978 2441 12 a) Infiltration 0 0 542 149 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)31 54 2520 3050 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 31 54 2520 3050 15 Duct loads 17%31%5 17 17%31%432 951 Total room load 37 70 2952 4001 Air required (cfm)Air required (cfm)2 3 159 190 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Oct-08 20:56:47 Right-Suite® Universal 2019 19.0.12 RSU08398 Page 5 ...CTS ENERGY\A- MANUAL J\KHOV-ASHMERE GOODMAN.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House LINDSTROMBy: Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name M BATH WIC MAST 2 Exposed wall 9.0 ft 5.0 ft 3 Room height 8.8 heat/coolft 8.8 heat/coolft 4 Room dimensions ft10.0x9.0 ft10.0x5.0 5 Room area 90.0 ft²50.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1D-h2om1D-h2om 0.3200.320 nn 8.968.96 14.0214.02 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1D-h2om1D-h2om 0.3200.320 ee 8.968.96 47.0847.08 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 81 81 324 177 45 45 180 98 GG 1D-h2om1D-h2om 0.3200.320 ss 8.968.96 14.0214.02 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1D-h2om1D-h2om 0.3200.320 ww 8.968.96 47.0847.08 0 0 0 0 0 0 0 0 GG 1D-h2omd1D-h2omd 0.5500.550 ww 15.4015.40 17.4717.47 0 0 0 0 0 0 0 0 PP 12B-0sw12B-0sw 0.0970.097 --2.722.72 1.331.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 ee 0.900.90 1.601.60 90 90 81 144 50 50 45 80 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 90 9 249 0 50 5 138 0 6 c) AED excursion -15 -9 Envelope loss/gain 654 306 363 170 12 a) Infiltration 184 50 102 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)838 356 466 198 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 838 356 466 198 15 Duct loads 17%31%144 111 17%31%80 62 Total room load 982 467 545 260 Air required (cfm)Air required (cfm)53 22 29 12