In-Place Density Test Report
Client:D. R. Horton America's Builder UES Technician:Johnnie Smith
6123 Lyons Road
Coconut Creek, FL 33073
Date Tested:10/05/2021
Project:CMT CREEKSIDE
Various Locations, Vero Beach, County, FL 32967
Type of Test:
Area Tested:Lot 126 / 9620 Potomac Dr,, Ft Pierce Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 E Section 0-1 ft 118.6 10.8 117.8 9.8 99 Pass
2 W Section 0-1 ft 118.6 10.8 117.9 10.0 99 Pass
3 Center 0-1 ft 118.6 10.8 118.0 9.9 99 Pass
Remarks:Permit 2104-1009
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G.
Abubakar, P.E. on the date adjacent to the seal. Printed copies of
this document are not considered signed and sealed and the
signature must be verified on any electronic copies.