HomeMy WebLinkAbout21-139C - Bryn Mawr Condos 2021 - Bldg C - Rep 6 - 10.01.21M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 21-139C Report No. 6
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
SLC Building Department
Mr. Chris Arias – Daniello & Associates, Inc.
Page 1 of 3
THRESHOLD INSPECTION REPORT
BRYN MAWR CONDOMINIUMS CONCRETE REPAIRS 2021 – BLDG. C
5055 N. HWY A1A, FORT PIERCE, FL 34949
SLC BLDG. DEPT. PERMIT NUMBER: 2106-0415
PROJECT NAME: Bryn Mawr Condominiums Concrete
Repairs 2021 – Bldg. C DATE: October 1, 2021
CLIENT: Elliott Merrill Community Management LOCATION: Fort Pierce, FL
CONTRACTOR: Daniello & Associates, Inc. PROJECT MGR: Mr. Chris Arias
INSPECTED BY: Todd Rhoten WEATHER: Sunny
WORK INSPECTED:
• Limited access balconies:
o Units 105, 506, 601 & 801 - Walk through to identify and highlight areas for repair.
o Units 201 & 801 - In progress inspection.
OBSERVATIONS:
Unit 105
• (1) surface spall was located at the west edge near the screen enclosure and is scheduled for demo.
Unit 201
• The north balcony edge and ceiling crack have been chipped of all loose concrete and corroded reinforcing
bars are exposed.
• The existing reinforcing bars were found to have some surface corrosion and are in serviceable condition.
• Bars have been power tooled cleaned and coated with the approved corrosion inhibitor.
Unit 506
• A column spall at the south kitchen sliding glass door jamb was found and is scheduled for demo.
Unit 601
• Found a surface spall adjacent to the east facing sliding glass door.
Unit 801
• A temporary weather wall has been placed inside the unit at the master bedroom.
• The sliding glass door and adjacent hurricane shutter top tracks have been removed.
• Ceiling spall – loose concrete has been chipped and corroded reinforcing has been exposed all the way to the
east edge.
Unit 805
• Loose topping was found at the east facing balcony.
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 21-139C Report No. 6
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
SLC Building Department
Mr. Chris Arias – Daniello & Associates, Inc.
Page 2 of 3
RECOMMENDATIONS:
Units 105, 506 & 601
• Chip and remove loose concrete to expose corroded reinforcing bars.
Units 201 & 801
• Form and pour repair areas with the approved concrete repair mortar.
______________________________ _________________________________
Michael Lue, P.E. Todd Rhoten
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 21-139C Report No. 6
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
SLC Building Department
Mr. Chris Arias – Daniello & Associates, Inc.
Page 3 of 3
Pic 1 - Unit 105
Surface spall at northeast edge
Pic 2 – Unit 601
Surface spall and adjacent to sliding glass door.
Pic 3 – Unit 801
Ceiling spall and edge repair