Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BRADY RESIDENCE Builder Name: HOMES BYABURTON Street: GULLOTTI PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number. Owner: JACK AND LYNN BRADY Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or eAsting New (From Plans) 10. Wall Types(2100.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead Aggret=0.0 1880.00 ft2 b. Frame - Wood, Adjacent R=11.0 220.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2048.0 sqft,) Insulation Area a. Roof Deck (Unvented) R=20.0 2048.00 ft2 6. Conditioned floor area above grade (ft2) 2048 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft' 7. Windows(296.3 sqft.) Description Area 12. Ducts a Sup: Attic, Ret: Attic, AH: Garage R ft2 6 150 a. U-Factor. Sgl, U=0.31 272.33 ft2 SHGC: SHGC=0.19 b. U-Factor: Sgl, U=0.26 24.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 36.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.194 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor.(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cep: 50 gallons 9. Floor Types (2048.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.145 Total Proposed Modified Loads: 66.13 PASS Total Baseline Loads: 68.28 I hereby certify that the plans and specifications covered by Review of the plans and O� ><HE STRTc� this calculation are in compliance with the Florida Energy Code. specifications covered by this indicates calculation compliance •;; �O with the Florida Energy Code. Fr a r,... r�(!•a ;;;:, �;;, 5 PREPARE BY• Before construction is completed DATE: 4- 6-202 this building will be inspected for compliance with Section 553.908 I hereby certify that this4bulldln esigned, is in compliance Florida Statutes.with the Florida Energy �,05 OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with 11402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 4/15/2021 4:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BRADY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2048 Lot # Owner Name: JACK AND LYNN BRADY Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMES BY ABURTON Rotate Angle: 0 Street: GULLOTTI PLACE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Detached FL, New/E)asting: New (From Plans) Comment CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp �/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2048 20480 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 186 1860 No 0 1 1 Yes Yes Yes 2 LAUNDRY RM 140 1400 No 0 1 Yes Yes Yes 3 CLST 2 18 180 No 0 i Yes Yes Yes 4 BEDROOM 2 168 1680 No 0 1 1 Yes Yes Yes 5 BATH 2 60 600 No 0 1 No Yes Yes 6 FAMILY RM 432 4320 No 0 1 Yes Yes Yes 7 KITCHEN 311 3110 Yes 0 1 Yes Yes Yes 8 HALLWAY 52 520 No 0 1 No Yes Yes 9 PANTRY Be 560 No 0 1 Yes Yes Yes 10 M BATH 224 2240 No 0 1 Yes Yes Yes 11 M TOILET 24 240 No 0 1 Yes Yes Yes 12 POWDER RM 34 340 No 0 1 No Yes Yes 13 M WIC 1 40 400 No 0 1 Yes Yes Yes 14 MWIC2 45 450 No 0 1 Yes Yes Yes 15 MASTER BEDR00 238 2380 No 0 1 1 Yes Yes Yes 16 M HALL 20 200 No 0 1 No Yes Yes FLOORS it Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 16 ft 186 ft2 �e 1 0 0 2 Slab -On -Grade Edge Insulation LAUNDRY RM 5 ft 140 It' .._ 1 0 0 4/15120214:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulation CLST 2 2 ft 18 ft2 _.. 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 2 26 ft 168 ft2 ___ 1 0 0 5 Slab -On -Grade Edge Insulation BATH 2 1 ft 60 ft2 1 0 0 6 Slab -On -Grade Edge Insulation FAMILY RM 34 ft 432 ft2 .__ 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN 25 ft 311 ft2 __ 1 0 0 8 Slab -on -Grade Edge Insulation HALLWAY 1 ft 52 ft2 1 0 0 9 Slab -On -Grade Edge Insulation PANTRY E ft 56 ft2 1 0 0 10Stab-On-Grade Edge Insulation M BATH 20 ft 224 ft2 __ 1 0 0 11SIab-On-Grade Edge Insulation M TOILET loft 24 ft2 1 0 0 12SIab-On-Grade Edge insulation POWDER RM 1 ft 34 ft2 1 0 0 13SIab-On-Grade Edge Insulation M W IC 1 8 ft 40 ft2 a 1 0 0 14Siab-On-Grade Edge Insulation M W IC 2 14 ft 45 ft2 w_ 1 0 0 15SIab-On-Grade Edge Insulation MASTER BEDRO 22 ft 238 ft! _.__ 1 0 0 16SIab-On-Grade Edge Insulation M HALL 1 ft 20 ft2 __ 1 0 0 ROOF Roof Gable Roof Red, Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Instil. (deg) 1 Hip Metal 2219 ft2 0 ft2 Light N 0.3 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2048 ft2 N N 4/15/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST Rr=PnRT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 3 0 Blown 186 ft2 0.1 Wood 2 Under Attic (Unvented) LAUNDRY RM 0 Blown 140 ft2 0.1 Wood 3 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 4 Under Attic (Unvented) BEDROOM 2 0 Blown 166 ft2 0.1 Wood 5 Under Attic (Unvented) BATH 2 0 Blown 60 ft2 0.1 Wood 6 Under Attic (Unvented) FAMILY RM 0 Blown 432 ft' 0.1 Wood 7 Under Attic (Unvented) KITCHEN 0 Blown 311 ft2 0.1 Wood 8 Under Attic (Unvented) HALLWAY 0 Blown 52 ft2 0.1 Wood 9 Under Attic (Unvented) PANTRY 0 Blown 56 ft2 0.1 Wood 10 Under Attic (Unvented) M BATH 0 Blown 224 ft2 0.1 Wood 11 Under Attic (Unvented) M TOILET 0 Blown 24 ft2 0.1 Wood 12 Under Attic (Unvented) POWDER RM 0 Blown 34 ft2 0.1 Wood 13 Under Attic (Unvented) M WIC 1 0 Blown 40 ft2 0.1 Wood 14 Under Attic (Unvented) M W IC 2 0 Blown 45 ft2 0.1 Wood 15 Under Attic (Unvented) MASTER BEDRO 0 Blown 238 ft2 0.1 Wood 16 Under Attic (Unvented) M HALL 0 Blown 20 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 S Exterior Concrete Block - PolystytiZB®ROOM 3 0 16 0 10 0 160.0 ft2 0 0 0.3 0 2 W Garage Frame - Wood BEDROOM 3 11 12 0 10 0 120.0 ft2 0 0.1 0.3 0 _ 3 N Exterior Concrete Block - Polystyd PJNDRY R 0 5 0 10 0 60.0 ft2 0 0 0.3 0 _ 4 W Garage Frame - Wood LAUNDRY R 11 10 0 10 0 100.0 ft2 0 0.1 0.3 0 _ 5 S Exterior Concrete Block - PolystyrenfiLST 2 0 2 0 10 0 20.0 ft2 0 0 0.3 0 _ 6 E Exterior Concrete Block- Polyst MOROOM 2 0 12 0 10 0 120.0 ft2 0 0 0.3 0 _ 7 S Exterior Concrete Block - PolystyMOROOM 2 0 14 0 10 0 140.0 ft2 0 0 0.3 0 _ 8 E Exterior Concrete Block - Polystyr&&ILY RM 0 24 0 10 0 240.0 ft2 0 0 0.3 0 _ 9 S Exterior Concrete Block - PolystyrVAMILY RM 0 10 0 10 0 100.0 ft2 0 0 0.3 0 10 N Exterior Concrete Block - PolystyreKijbTCHEN 0 8 0 10 0 80.0 1`1:2 0 0 0.3 0 11 W Exterior Concrete Block - Polystyre0TCHEN 0 17 0 10 0 170.0 ft2 0 0 0.3 0 _ 12 W Exterior Concrete Block - PolystyreiRANTRY 0 6 0 10 0 60.0 ft2 0 0 0.3 0 _ 13 N Exterior Concrete Block - Polystyreft BATH 0 14 0 10 0 140.0 f12 0 0 0.3 0 14 W Exterior Concrete Block - Polystyrend BATH 0 6 0 10 0 60.0 ft2 0 0 0.3 0 _ 15 N Exterior Concrete Block - Polystyr&sTOILET 0 6 0 10 0 60.0 ft2 0 0 0.3 0 16 W Exterior Concrete Block - PolystyrdhbTOILET 0 4 0 10 0 40.0 ft2 0 0 0.3 0 _ 17 N Exterior Concrete Block - Polystyreft W IC 1 0 8 0 10 0 80.0 ft2 0 0 0.3 0 18 N Exterior Concrete Block - Polystyredd W IC 2 0 9 0 10 0 90.0 ft2 0 0 0.3 0 19 E Exterior Concrete Block - Polystyreft W IC 2 0 5 0 10 0 50.0 1`12 0 0 0.3 0 _ 20 E Exterior Concrete Block - Polysty"TER BE 0 14 0 10 0 140.0 ft2 0 0 0.3 0 21 S Exterior Concrete Block - Polysty TER BE 0 8 0 10 0 80.0 ft2 0 0 0.3 0 4/15/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown Is the entered Proposed orientation. / wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation int Shade Screening 1 S 1 Vinyl Low-E Single Yes 0.31 0.19 Y 21.3 ft2 1 ft 4 In 1 ft 4 in None None 2 N 3 Vinyl Low-E Single Yes 0.31 0.19 Y 9.0 f? 1 ft 4 In 1 ft 4 in None None 3 E 6 Vinyl Low-E Single Yes 0.31 0.19 Y 18.0 ft2 1 ft 4 In 1 ft 4 in None None 4 E 8 Vinyl Low-E Single Yes 0.31 0.19 Y 72.0 ft2 1 ft 4 in 1 ft 4 In None None 5 E 8 Vinyl Low-E Single Yes 0.31 0.19 Y 48.0 ft2 1 ft 4 in 1 ft 4 In None None 6 S 9 Vinyl Low-E Single Yes 0.31 0.19 Y 48.0 ft2 1 ft 4 in 1 ft 4 in None None 7 W 11 Vinyl Low-E Single Yes 0.31 0.19 Y 16.0 ft2 1 ft 4 In 1 ft 4 in None None 8 W 11 Vinyl Low-E Single Yes 0.26 0.24 Y 12.0 ft2 1 ft 41n 1 ft 4 In None None 9 W 12 Vinyl Low-E Single Yes 0.26 0.24 Y 6.0 ft2 1 ft 4 In 1 ft 4 In None None 10 N 13 Vinyl Low-E Single Yes 0.31 0.19 Y 10.0 ft2 1 ft 4 in 1 ft 4 in None None 11 W 14 Vinyl Low-E Single Yes 0.26 0.24 Y 6.0 ft2 1 ft 4 in 1 ft 4 in None None 12 E 20 Vinyl Low-E Single Yes 0.31 0.19 Y 30.0 ft2 1 ft 4 In 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wail Insulation 1 484 ft2 484 f12 22 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000317 1706.7 93.63 175.79 .0987 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heatt None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:16 36 kBtu/hr 1080 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft, 4/15/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DUCTS / ---- Supply --- ---- Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage Garage (Default) c(Default) c 1 1 F,-,g.,,, TEMPERATURES mable Thermostat: N Ceiling Fans: oJan Feb HeatinJan Feb ((�� Mar (X] Mar [ [ A r 7 Apr Ma M� Jun Jun Jul Jul Au Aug Se Sep Oct Oct Nov Nov Dec Dec Venting Jan Feb [[�X11 Mar [X] Jun Jul Aug Sep X Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM MM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 6B 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.fL ft2 ft 0.3 LAUNDRY RM Default(8 lbs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft, ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8lbslsq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.fL ft2 ft 0.3 M TOILET Defauit(8 Ibs/sq.ft. ft2 ft 0.3 POWDER RM Default(8lbs/sq.fL ft2 ft 0.3 M WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft, ft2 ft 0.3 MASTER BEDROO Default(8 lbs/sci.ft. ft2 ft 0.3 M HALL 4/16/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6