HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BRADY RESIDENCE
Builder Name: HOMES BYABURTON
Street: GULLOTTI PLACE
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL,
Permit Number.
Owner: JACK AND LYNN BRADY
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or eAsting New (From Plans)
10. Wall Types(2100.0 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead Aggret=0.0 1880.00 ft2
b. Frame - Wood, Adjacent
R=11.0 220.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2048.0 sqft,)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2048.00 ft2
6. Conditioned floor area above grade (ft2) 2048
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft'
7. Windows(296.3 sqft.) Description Area
12. Ducts
a Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 150
a. U-Factor. Sgl, U=0.31 272.33 ft2
SHGC: SHGC=0.19
b. U-Factor: Sgl, U=0.26 24.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.24
a. Central Unit
36.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.333 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.194
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor.(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cep: 50 gallons
9. Floor Types (2048.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.145 Total Proposed Modified Loads: 66.13
PASS
Total Baseline Loads: 68.28
I hereby certify that the plans and specifications covered by
Review of the plans and
O� ><HE STRTc�
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
indicates
calculation compliance
•;;
�O
with the Florida Energy Code.
Fr a r,... r�(!•a ;;;:, �;;, 5
PREPARE BY•
Before construction is completed
DATE: 4- 6-202
this building will be inspected for
compliance with Section 553.908
I hereby certify that this4bulldln esigned, is in compliance
Florida Statutes.with
the Florida Energy
�,05
OWNER/AGEN
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with 11402A.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
4/15/2021 4:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
BRADY RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2048
Lot #
Owner Name:
JACK AND LYNN BRADY
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
HOMES BY ABURTON
Rotate Angle: 0
Street:
GULLOTTI PLACE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Detached
FL,
New/E)asting:
New (From Plans)
Comment
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design
Daily Temp
�/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2048
20480
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BEDROOM 3
186
1860 No
0
1
1
Yes
Yes
Yes
2
LAUNDRY RM
140
1400 No
0
1
Yes
Yes
Yes
3
CLST 2
18
180 No
0
i
Yes
Yes
Yes
4
BEDROOM 2
168
1680 No
0
1
1
Yes
Yes
Yes
5
BATH 2
60
600 No
0
1
No
Yes
Yes
6
FAMILY RM
432
4320 No
0
1
Yes
Yes
Yes
7
KITCHEN
311
3110 Yes
0
1
Yes
Yes
Yes
8
HALLWAY
52
520 No
0
1
No
Yes
Yes
9
PANTRY
Be
560 No
0
1
Yes
Yes
Yes
10
M BATH
224
2240 No
0
1
Yes
Yes
Yes
11
M TOILET
24
240 No
0
1
Yes
Yes
Yes
12
POWDER RM
34
340 No
0
1
No
Yes
Yes
13
M WIC 1
40
400 No
0
1
Yes
Yes
Yes
14
MWIC2
45
450 No
0
1
Yes
Yes
Yes
15
MASTER BEDR00
238
2380 No
0
1
1
Yes
Yes
Yes
16
M HALL
20
200 No
0
1
No
Yes
Yes
FLOORS
it
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 3 16 ft
186 ft2
�e
1 0
0
2 Slab -On -Grade Edge Insulation
LAUNDRY RM 5 ft
140 It'
.._
1 0
0
4/15120214:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
3 Slab -On -Grade Edge Insulation
CLST 2
2 ft
18 ft2
_..
1
0
0
4 Slab -On -Grade Edge Insulation
BEDROOM 2
26 ft
168 ft2
___
1
0
0
5 Slab -On -Grade Edge Insulation
BATH 2
1 ft
60 ft2
1
0
0
6 Slab -On -Grade Edge Insulation
FAMILY RM
34 ft
432 ft2
.__
1
0
0
7 Slab -On -Grade Edge Insulation
KITCHEN
25 ft
311 ft2
__
1
0
0
8 Slab -on -Grade Edge Insulation
HALLWAY
1 ft
52 ft2
1
0
0
9 Slab -On -Grade Edge Insulation
PANTRY
E ft
56 ft2
1
0
0
10Stab-On-Grade Edge Insulation
M BATH
20 ft
224 ft2
__
1
0
0
11SIab-On-Grade Edge Insulation
M TOILET
loft
24 ft2
1
0
0
12SIab-On-Grade Edge insulation
POWDER RM
1 ft
34 ft2
1
0
0
13SIab-On-Grade Edge Insulation
M W IC 1
8 ft
40 ft2
a
1
0
0
14Siab-On-Grade Edge Insulation
M W IC 2
14 ft
45 ft2
w_
1
0
0
15SIab-On-Grade Edge Insulation
MASTER BEDRO 22 ft
238 ft!
_.__
1
0
0
16SIab-On-Grade Edge Insulation
M HALL
1 ft
20 ft2
__
1
0
0
ROOF
Roof
Gable Roof
Red,
Solar SA Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Instil.
(deg)
1 Hip Metal 2219 ft2
0 ft2 Light
N
0.3 No 0.9
No
20
22.62
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2048 ft2
N N
4/15/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST Rr=PnRT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) BEDROOM 3
0
Blown
186 ft2
0.1
Wood
2
Under Attic (Unvented) LAUNDRY RM
0
Blown
140 ft2
0.1
Wood
3
Under Attic (Unvented) CLST 2
0
Blown
18 ft2
0.1
Wood
4
Under Attic (Unvented) BEDROOM 2
0
Blown
166 ft2
0.1
Wood
5
Under Attic (Unvented) BATH 2
0
Blown
60 ft2
0.1
Wood
6
Under Attic (Unvented) FAMILY RM
0
Blown
432 ft'
0.1
Wood
7
Under Attic (Unvented) KITCHEN
0
Blown
311 ft2
0.1
Wood
8
Under Attic (Unvented) HALLWAY
0
Blown
52 ft2
0.1
Wood
9
Under Attic (Unvented) PANTRY
0
Blown
56 ft2
0.1
Wood
10
Under Attic (Unvented) M BATH
0
Blown
224 ft2
0.1
Wood
11
Under Attic (Unvented) M TOILET
0
Blown
24 ft2
0.1
Wood
12
Under Attic (Unvented) POWDER RM
0
Blown
34 ft2
0.1
Wood
13
Under Attic (Unvented) M WIC 1
0
Blown
40 ft2
0.1
Wood
14
Under Attic (Unvented) M W IC 2
0
Blown
45 ft2
0.1
Wood
15
Under Attic (Unvented) MASTER BEDRO
0
Blown
238 ft2
0.1
Wood
16
Under Attic (Unvented) M HALL
0
Blown
20 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
_ 1
S
Exterior Concrete Block - PolystytiZB®ROOM 3
0
16
0 10
0
160.0 ft2
0
0
0.3
0
2
W
Garage Frame - Wood BEDROOM 3
11
12
0 10
0
120.0 ft2
0
0.1
0.3
0
_ 3
N
Exterior Concrete Block - Polystyd PJNDRY R
0
5
0 10
0
60.0 ft2
0
0
0.3
0
_ 4
W
Garage Frame - Wood LAUNDRY R
11
10
0 10
0
100.0 ft2
0
0.1
0.3
0
_ 5
S
Exterior Concrete Block - PolystyrenfiLST 2
0
2
0 10
0
20.0 ft2
0
0
0.3
0
_ 6
E
Exterior Concrete Block- Polyst MOROOM 2
0
12
0 10
0
120.0 ft2
0
0
0.3
0
_ 7
S
Exterior Concrete Block - PolystyMOROOM 2
0
14
0 10
0
140.0 ft2
0
0
0.3
0
_ 8
E
Exterior Concrete Block - Polystyr&&ILY RM
0
24
0 10
0
240.0 ft2
0
0
0.3
0
_ 9
S
Exterior Concrete Block - PolystyrVAMILY RM
0
10
0 10
0
100.0 ft2
0
0
0.3
0
10
N
Exterior Concrete Block - PolystyreKijbTCHEN
0
8
0 10
0
80.0 1`1:2
0
0
0.3
0
11
W
Exterior Concrete Block - Polystyre0TCHEN
0
17
0 10
0
170.0 ft2
0
0
0.3
0
_ 12
W
Exterior Concrete Block - PolystyreiRANTRY
0
6
0 10
0
60.0 ft2
0
0
0.3
0
_ 13
N
Exterior Concrete Block - Polystyreft BATH
0
14
0 10
0
140.0 f12
0
0
0.3
0
14
W
Exterior Concrete Block - Polystyrend BATH
0
6
0 10
0
60.0 ft2
0
0
0.3
0
_ 15
N
Exterior Concrete Block - Polystyr&sTOILET
0
6
0 10
0
60.0 ft2
0
0
0.3
0
16
W
Exterior Concrete Block - PolystyrdhbTOILET
0
4
0 10
0
40.0 ft2
0
0
0.3
0
_ 17
N
Exterior Concrete Block - Polystyreft W IC 1
0
8
0 10
0
80.0 ft2
0
0
0.3
0
18
N
Exterior Concrete Block - Polystyredd W IC 2
0
9
0 10
0
90.0 ft2
0
0
0.3
0
19
E
Exterior Concrete Block - Polystyreft W IC 2
0
5
0 10
0
50.0 1`12
0
0
0.3
0
_ 20
E
Exterior Concrete Block - Polysty"TER BE
0
14
0 10
0
140.0 ft2
0
0
0.3
0
21
S
Exterior Concrete Block - Polysty TER BE
0
8
0 10
0
80.0 ft2
0
0
0.3
0
4/15/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown Is the entered Proposed orientation.
/
wall
Overhang
V #
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp Area
Depth
Separation int Shade
Screening
1
S 1 Vinyl
Low-E Single
Yes
0.31 0.19 Y 21.3 ft2
1 ft 4 In
1 ft 4 in
None
None
2
N 3 Vinyl
Low-E Single
Yes
0.31 0.19 Y 9.0 f?
1 ft 4 In
1 ft 4 in
None
None
3
E 6 Vinyl
Low-E Single
Yes
0.31 0.19 Y 18.0 ft2
1 ft 4 In
1 ft 4 in
None
None
4
E 8 Vinyl
Low-E Single
Yes
0.31 0.19 Y 72.0 ft2
1 ft 4 in
1 ft 4 In
None
None
5
E 8 Vinyl
Low-E Single
Yes
0.31 0.19 Y 48.0 ft2
1 ft 4 in
1 ft 4 In
None
None
6
S 9 Vinyl
Low-E Single
Yes
0.31 0.19 Y 48.0 ft2
1 ft 4 in
1 ft 4 in
None
None
7
W 11 Vinyl
Low-E Single
Yes
0.31 0.19 Y 16.0 ft2
1 ft 4 In
1 ft 4 in
None
None
8
W 11 Vinyl
Low-E Single
Yes
0.26 0.24 Y 12.0 ft2
1 ft 41n
1 ft 4 In
None
None
9
W 12 Vinyl
Low-E Single
Yes
0.26 0.24 Y 6.0 ft2
1 ft 4 In
1 ft 4 In
None
None
10
N 13 Vinyl
Low-E Single
Yes
0.31 0.19 Y 10.0 ft2
1 ft 4 in
1 ft 4 in
None
None
11
W 14 Vinyl
Low-E Single
Yes
0.26 0.24 Y 6.0 ft2
1 ft 4 in
1 ft 4 in
None
None
12
E 20 Vinyl
Low-E Single
Yes
0.31 0.19 Y 30.0 ft2
1 ft 4 In
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wail Insulation
1
484 ft2
484 f12
22 ft loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000317
1706.7 93.63 175.79
.0987
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heatt
None
COP:1 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER:16 36 kBtu/hr 1080 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.98 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
#
Area
Volume FEF
None None
ft,
4/15/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
DUCTS
/ ---- Supply ---
---- Return --
Air
CFM 25
CFM25
HVAC #
V # Location
R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 150 ft2
Attic
15 ft2
Default Leakage
Garage
(Default) c(Default) c
1 1
F,-,g.,,,
TEMPERATURES
mable Thermostat:
N
Ceiling Fans:
oJan Feb
HeatinJan Feb
((�� Mar
(X] Mar
[
[
A r
7 Apr
Ma
M�
Jun
Jun
Jul
Jul
Au
Aug
Se
Sep
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan
Feb
[[�X11 Mar
[X]
Jun
Jul
Aug
Sep
X
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
MM
80
80
80
80
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Heating(WD)
AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
6B 68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 3
Default(8 Ibs/sq.fL
ft2
ft
0.3
LAUNDRY RM
Default(8 lbs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft,
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8lbslsq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.fL
ft2
ft
0.3
M TOILET
Defauit(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER RM
Default(8lbs/sq.fL
ft2
ft
0.3
M WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft,
ft2
ft
0.3
MASTER BEDROO
Default(8 lbs/sci.ft.
ft2
ft
0.3
M HALL
4/16/20214:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6