HomeMy WebLinkAboutBryant whole house Manual J_10-5-21Residential System Sizing Calculation
Summary
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
10/5/2021
Location for weather data: St. Lucie, FL - Defaults: L a t i t u d e ( 2 7 . 4 8 ) Altitude(7 ft.) Temp Range(M)
Humidity data: Interior RH (50%) Outdoor wet bulb (78F) Humidity difference(58gr.)
Winter design temperature(TMY3 99%) 40 F Summer design temperature(TMY3 99%) 91 F
Winter setpoint 70 F Summer setpoint 75 F
Winter temperature difference 30 F Summer temperature difference 16 F
Total heating load calculation 21619 Btuh Total cooling load calculation 21984 Btuh
Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh
Total (Electric Heat Pump)115.6 25000 Sensible (SHR = 0.75)80.4 16500
Heat Pump + Auxiliary(0.0kW) 115.6 25000 L a t e n t 374.8 5500
T o t a l (Electric Heat Pump) 100.1 22000
WINTER CALCULATIONS
Winter Heating Load (for 984 sqft)
Load component Load
Window total 296 sqft 10049 Btuh
Wall total 1059 sqft 4603 Btuh
Door total 40 sqft 552 Btuh
Ceiling total 984 sqft 2430 Btuh
Floor total See detail report 2571 Btuh
Infiltration 43 cfm 1414 Btuh
Duct loss 0 Btuh
Subtotal 21619 Btuh
Ventilation 0 cfm 0 Btuh
TOTAL HEAT LOSS 21619 Btuh
Summer Cooling Load (for 984 sqft)
Load component Load
Window total 296 sqft 10805 Btuh
Wall total 1059 sqft 4219 Btuh
Door total 40 sqft 497 Btuh
Ceiling total 984 sqft 2057 Btuh
Floor total 943 Btuh
Infiltration 32 cfm 566 Btuh
Internal gain 1430 Btuh
Duct gain 0 Btuh
Sens. Ventilation 0 cfm 0 Btuh
Blower Load 0 Btuh
Total sensible gain 20516 Btuh
Latent gain(ducts)0 Btuh
Latent gain(infiltration)1268 Btuh
Latent gain(ventilation)0 Btuh
Latent gain(internal/occupants/other)200 Btuh
Total latent gain 1468 Btuh
TOTAL HEAT GAIN 21984 Btuh
EnergyGauge® / USRCZB v7.0.00
SUMMER CALCULATIONS
8th Edition
EnergyGauge® System Sizing
PREPARED BY: _________________________________
DATE: ________________________________________October 5, 2021
Certificate of Product Ratings
†
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and
confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated;
entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user’s individual,
personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on “Verify Certificate” link
and enter the AHRI Certified Reference Number and the date on which the certificate was issued,
which is listed above, and the Certificate No., which is listed at bottom right.
© Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.:
Date : 10-05-2021
Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous (i.e. WAS) rating.
†"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being
marketed but are not yet being produced.“Production Stopped” Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still
selling or offering for sale.
2021
AHRI Certified Reference Number : 201754902 Model Status : Active
AHRI Type : HMSV-A-CB-O (Multi-Split Heat Pump, Free Delivery)
Series Name : M-Series
Outdoor Unit Brand Name : Mitsubishi Electric
Outdoor Unit Model Number : MXZ-3C24NA2
Indoor Type : Non-Ducted Indoor Units
Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary
Air-Conditioning & Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing:
Cooling Capacity (95F) : 22000
EER (95F) : 13.60
SEER : 20.00
High Heat (47F) : 25000
Low Heat (17F) : 14000
HSPF : 9.80
Sold in? : USA
Eligible for Federal Tax Credit.
Eligible For Federal Tax Credit (installed between 2/17/09 and 12/1/16)
132779137655113198
System Sizing Calculations - Winter
Residential Load - Whole House Component Details
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Building Type: User
10/5/2021
Reference City: St. Lucie, FL ( D e f a u l t s ) Winter Temperature Difference: 30.0 F (TMY3 99%)
Component Loads for Whole House
Window Frame UP a n e s / T y p e Orientation Area(sqft) X HTM=L o a d
1 1, Tint Metal 1.13 S 13.7 33.9 465 Btuh
2 1, Tint Metal 1.13 E 12.0 33.9 407 Btuh
3 1, Tint Metal 1.13 E 12.0 33.9 407 Btuh
4 1, Tint Metal 1.13 S 10.8 33.9 367 Btuh
5 1, Tint Metal 1.13 S 10.8 33.9 367 Btuh
6 1, Tint Metal 1.13 S 10.8 33.9 367 Btuh
7 1, Tint Metal 1.13 W 10.8 33.9 367 Btuh
8 1, Tint Metal 1.13 W 10.8 33.9 367 Btuh
9 1, Tint Metal 1.13 W 10.8 33.9 367 Btuh
10 1, Tint Metal 1.13 W 8.3 33.9 282 Btuh
11 1, Tint Metal 1.13 W 8.3 33.9 282 Btuh
12 1, Tint Metal 1.13 W 8.3 33.9 282 Btuh
13 1, Tint Metal 1.13 W 9.4 33.9 320 Btuh
14 1, Tint Metal 1.13 N 9.4 33.9 320 Btuh
15 1, Tint Metal 1.13 N 9.4 33.9 320 Btuh
16 1, Tint Metal 1.13 E 9.4 33.9 320 Btuh
17 1, Tint Metal 1.13 E 9.4 33.9 320 Btuh
18 1, Tint Metal 1.13 E 9.4 33.9 320 Btuh
19 1, Tint Metal 1.13 N 13.7 33.9 465 Btuh
20 1, Tint Metal 1.13 N 13.7 33.9 465 Btuh
21 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
22 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
23 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
24 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
25 1, Tint Metal 1.13 S 13.7 33.9 465 Btuh
26 1, Clear Metal 1.13 S 16.0 33.9 542 Btuh
Window Total 296.4(sqft)10049 Btuh
Walls Ornt.Ueff.R-ValueT y p e Area X HTM=L o a d
( C a v / S h )
1 Frame - Wood - Ext (0.145)4.1/0.0 63 4.35 272 Btuh
2 Frame - Wood - Ext (0.145)4.1/0.0 38 4.35 164 Btuh
3 Frame - Wood - Ext (0.145)4.1/0.0 50 4.35 215 Btuh
4 Frame - Wood - Ext (0.145)4.1/0.0 428 4.35 1859 Btuh
5 Frame - Wood - Ext (0.145)4.1/0.0 71 4.35 309 Btuh
6 Frame - Wood - Ext (0.145)4.1/0.0 157 4.35 683 Btuh
7 Frame - Wood - Ext (0.145)4.1/0.0 79 4.35 341 Btuh
8 Frame - Wood - Ext (0.145)4.1/0.0 175 4.35 759 Btuh
Wall Total 1059(sqft)4603 Btuh
Doors Storm Ueff.Type Area X HTM=L o a d
1 Wood - Exterior,n (0.460) 24 13.8 331 Btuh
2 Wood - Exterior,n (0.460) 16 13.8 221 Btuh
Door Total 40(sqft)552Btuh
EnergyGauge® / USRCZB v7.0.00 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Building Type: User
10/5/2021
Ceilings Ueff.T y p e / C o l o r / S u r f a c e R - V a l u e Area X HTM=L o a d
1 Cathedral/W /M e t a l (0.082)9.0/0.0 672 2.5 1659 Btuh
2 Cathedral/W /M e t a l (0.082)9.0/0.0 312 2.5 770 Btuh
Ceiling Total 984(sqft)2430Btuh
Floors Ueff.T y p e R - V a l u e Size X HTM=L o a d
1 Raised - Open ( 0 . 0 8 7 )9.0 672.0 s q f t 2.6 1756 Btuh
2 Raised - Open ( 0 . 0 8 7 )9.0 312.0 s q f t 2.6 815 Btuh
Floor Total 984 s q f t 2571 Btuh
Envelope Subtotal: 20205 Btuh
Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM=
Natural 0.33 7872 1.00 42.9 1414 Btuh
Duct load NA, R0.0, Supply(), Return()(DLM of 0.000)0 Btuh
All Zones Sensible Subtotal All Zones 21619 Btuh
WHOLE HOUSE TOTALS
Subtotal Sensible Heat Loss 21619 Btuh
Totals for Heating Ventilation Sensible Heat Loss 0 Btuh
Total Heat Loss 21619 Btuh
EQUIPMENT
1. Electric Heat Pump # M X Z 3 C 2 4 N A 2 25000 Btuh
Key: Window types - NFRC (Requires U-Factor and Shading coefficient(SHGC) of glass as numerical values)
or - Glass as 'Clear' or 'Tint' (Uses U-Factor and SHGC defaults)
U - (Window U-Factor)
HTM - (ManualJ Heat Transfer Multiplier)
Version 8
EnergyGauge® / USRCZB v7.0.00 Page 2
System Sizing Calculations - Summer
Residential Load - Whole House Component Details
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
10/5/2021
Reference City: St. Lucie, FL Temperature Difference: 16.0F(TMY3 99%)Humidity difference: 58gr.
Component Loads for Whole House
Type*Overhang Window Area(sqft)HTM L o a d
Window Panes SHGC U InSh IS O r n t Len Hgt Gross Shaded Unshaded Shaded Unshaded
1 1 Tint 0 . 5 2 , 1.13 N o No S 7.0ft 2.0ft 13.7 13.7 0.0 29 32 401 Btuh
2 1 Tint 0 . 5 2 , 1.13 N o No E 12.0f 2.0ft 12.0 12.0 0.0 29 69 351 Btuh
3 1 Tint 0 . 5 2 , 1.13 N o No E 12.0f 2.0ft 12.0 12.0 0.0 29 69 351 Btuh
4 1 Tint 0 . 5 2 , 1.13 N o No S 4.5ft 0.2ft 10.8 10.8 0.0 29 32 316 Btuh
5 1 Tint 0 . 5 2 , 1.13 N o No S 4.5ft 0.2ft 10.8 10.8 0.0 29 32 316 Btuh
6 1 Tint 0 . 5 2 , 1.13 B-L No S 4.5ft 0.2ft 10.8 10.8 0.0 24 26 255 Btuh
7 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 10.8 10.8 0.0 29 69 316 Btuh
8 1 Tint 0 . 5 2 , 1.13 B-L No W 9.0ft 3.0ft 10.8 10.8 0.0 24 53 255 Btuh
9 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 10.8 10.8 0.0 29 69 316 Btuh
10 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 8.3 8.3 0.0 29 69 243 Btuh
11 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 8.3 8.3 0.0 29 69 243 Btuh
12 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 8.3 8.3 0.0 29 69 243 Btuh
13 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 9.4 9.4 0.0 29 69 276 Btuh
14 1 Tint 0 . 5 2 , 1.13 B-L No N 3.0ft 0.2ft 9.4 0.0 9.4 24 24 222 Btuh
15 1 Tint 0 . 5 2 , 1.13 B-L No N 3.0ft 0.2ft 9.4 0.0 9.4 24 24 222 Btuh
16 1 Tint 0 . 5 2 , 1.13 N o No E 3.0ft 0.2ft 9.4 6.6 2.9 29 69 388 Btuh
17 1 Tint 0 . 5 2 , 1.13 N o No E 3.0ft 0.2ft 9.4 6.6 2.9 29 69 388 Btuh
18 1 Tint 0 . 5 2 , 1.13 B-L No E 3.0ft 0.2ft 9.4 6.6 2.9 24 54 311 Btuh
19 1 Tint 0 . 5 2 , 1.13 B-L No N 4.0ft 0.2ft 13.7 0.0 13.7 24 24 323 Btuh
20 1 Tint 0 . 5 2 , 1.13 B-L No N 4.0ft 0.2ft 13.7 0.0 13.7 24 24 323 Btuh
21 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
22 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
23 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
24 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
25 1 Tint 0 . 5 2 , 1.13 N o No S 4.0ft 0.2ft 13.7 13.7 0.0 29 32 401 Btuh
26 1 Clear 0 . 7 4 , 1.13 N o No S 0.0ft 0.0ft 16.0 0.0 16.0 34 38 603 Btuh
E x c u r s i o n 1548 Btuh
Window Total 296 ( s q f t ) 10805 Btuh
Walls Type U-Value R-Value Area(sqft)HTM Load
Cav/Sheath
1 Frame - Wood - Ext 0.14 4.1/0.0 62.6 4.0 249 Btuh
2 Frame - Wood - Ext 0.14 4.1/0.0 37.8 4.0 151 Btuh
3 Frame - Wood - Ext 0.14 4.1/0.0 49.5 4.0 197 Btuh
4 Frame - Wood - Ext 0.14 4.1/0.0 427.7 4.0 1704 Btuh
5 Frame - Wood - Ext 0.14 4.1/0.0 71.1 4.0 283 Btuh
6 Frame - Wood - Ext 0.14 4.1/0.0 157.2 4.0 626 Btuh
7 Frame - Wood - Ext 0.14 4.1/0.0 78.6 4.0 313 Btuh
8 Frame - Wood - Ext 0.14 4.1/0.0 174.8 4.0 696 Btuh
Wall Total 1059 ( s q f t )4219 Btuh
Doors Type Area (sqft)HTM Load
1 Wood - Exterior 24.0 12.4 298 Btuh
2 Wood - Exterior 16.0 12.4 199 Btuh
Door Total 40 ( s q f t )497 Btuh
Ceilings U-Value R-ValueType/Color/Surface Area(sqft)HTM Load
1 Cath/Sngl Assem/White/Metal 0.082 9.0/0.0 672.0 2.09 1405 Btuh
2 Cath/Sngl Assem/White/Metal 0.082 9.0/0.0 312.0 2.09 652 Btuh
Ceiling Total 984 ( s q f t )2057 Btuh
EnergyGauge® / USRCZB v7.0.00 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Climate:FL_VERO_BEACH_MUNICIPAL_A
10/5/2021
Floors R-ValueType Size HTM Load
1 Raised - Open 9.0 672 ( s q f t )1.0 644 Btuh
2 Raised - Open 9.0 312 ( s q f t )1.0 299 Btuh
Floor Total 984.0 ( s q f t )943 Btuh
Envelope Subtotal: 18521 Btuh
Infiltration AverageType A C H Volume(cuft) Wall Ratio CFM=Load
Natural 0.25 7872 1 32.1 566 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 1 X 230 +1200 1430 Btuh
Sensible Envelope Load: 20516 Btuh
Duct load N A , Supply(R0.0-None), Return(R0.0-None)(DGM of 0.000) 0 Btuh
Sensible Load All Zones 20516 Btuh
EnergyGauge® / USRCZB v7.0.00 Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Climate:FL_VERO_BEACH_MUNICIPAL_A
10/5/2021
WHOLE HOUSE TOTALS
Sensible Envelope Load All Zones 20516 Btuh
Sensible Duct Load 0 Btuh
Total Sensible Zone Loads 20516 Btuh
Sensible ventilation 0 Btuh
B l o w e r 0 Btuh
Whole House Total sensible gain 20516 Btuh
Totals for Cooling Latent infiltration gain (for 58 gr. humidity difference)1268 Btuh
Latent ventilation gain 0 Btuh
Latent duct gain 0 Btuh
Latent occupant gain (1.0 people @ 200 Btuh per person)200 Btuh
Latent other gain 0 Btuh
Latent total gain 1468 Btuh
TOTAL GAIN 21984 Btuh
EQUIPMENT
1. Central Unit # M X Z 3 C 2 4 N A 2 22000 Btuh
*Key: Window types (Panes - Number and type of panes of glass)
(SHGC - Shading coefficient of glass as SHGC numerical value)
(U - Window U-Factor)
(InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half closed
(IS - Insect screen: none(N), Full(F) or Half(½))
(Ornt - compass orientation)
Version 8
EnergyGauge® / USRCZB v7.0.00 Page 3
System Sizing Calculations - Winter
Residential Load - Room by Room Component Details
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Building Type: User
10/5/2021
Reference City: St. Lucie, FL ( D e f a u l t s ) Winter Temperature Difference: 30.0 F (TMY3 99%)
Component Loads for Room #1: Main
Window Frame UP a n e s / T y p e Orientation Area(sqft) X HTM=L o a d
2 1, Tint Metal 1.13 E 12.0 33.9 407 Btuh
3 1, Tint Metal 1.13 E 12.0 33.9 407 Btuh
4 1, Tint Metal 1.13 S 10.8 33.9 367 Btuh
5 1, Tint Metal 1.13 S 10.8 33.9 367 Btuh
6 1, Tint Metal 1.13 S 10.8 33.9 367 Btuh
7 1, Tint Metal 1.13 W 10.8 33.9 367 Btuh
8 1, Tint Metal 1.13 W 10.8 33.9 367 Btuh
9 1, Tint Metal 1.13 W 10.8 33.9 367 Btuh
10 1, Tint Metal 1.13 W 8.3 33.9 282 Btuh
11 1, Tint Metal 1.13 W 8.3 33.9 282 Btuh
12 1, Tint Metal 1.13 W 8.3 33.9 282 Btuh
13 1, Tint Metal 1.13 W 9.4 33.9 320 Btuh
14 1, Tint Metal 1.13 N 9.4 33.9 320 Btuh
15 1, Tint Metal 1.13 N 9.4 33.9 320 Btuh
16 1, Tint Metal 1.13 E 9.4 33.9 320 Btuh
17 1, Tint Metal 1.13 E 9.4 33.9 320 Btuh
18 1, Tint Metal 1.13 E 9.4 33.9 320 Btuh
Window Total 170.7(sqft)5786 Btuh
Walls Ornt.Ueff.R-ValueT y p e Area X HTM=L o a d
( C a v / S h )
2 Frame - Wood - Ext (0.145)4.1/0.0 38 4.35 164 Btuh
3 Frame - Wood - Ext (0.145)4.1/0.0 50 4.35 215 Btuh
4 Frame - Wood - Ext (0.145)4.1/0.0 428 4.35 1859 Btuh
5 Frame - Wood - Ext (0.145)4.1/0.0 71 4.35 309 Btuh
6 Frame - Wood - Ext (0.145)4.1/0.0 157 4.35 683 Btuh
Wall Total 743(sqft)3230 Btuh
Doors Storm Ueff.Type Area X HTM=L o a d
1 Wood - Exterior,n (0.460) 24 13.8 331 Btuh
2 Wood - Exterior,n (0.460) 16 13.8 221 Btuh
Door Total 40(sqft)552Btuh
Ceilings Ueff.T y p e / C o l o r / S u r f a c e R - V a l u e Area X HTM=L o a d
1 Cathedral/W /M e t a l (0.082)9.0/0.0 672 2.5 1659 Btuh
Ceiling Total 672(sqft)1659Btuh
Floors Ueff.T y p e R - V a l u e Size X HTM=L o a d
1 Raised - Open ( 0 . 0 8 7 )9.0 672.0 s q f t 2.6 1756 Btuh
Floor Total 672 s q f t 1756 Btuh
Room Envelope Subtotal: 12983 Btuh
Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.33 5376 0.70 30.1 992 Btuh
EnergyGauge® / USRCZB v7.0.00 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Building Type: User
10/5/2021
Duct load No ducts assigned to this zone.(DLM of 0.000)0 Btuh
Room #1 Sensible Room Subtotal 13975 Btuh
Component Loads for Room #2: Living Room
Window Frame UP a n e s / T y p e Orientation Area(sqft) X HTM=L o a d
1 1, Tint Metal 1.13 S 13.7 33.9 465 Btuh
19 1, Tint Metal 1.13 N 13.7 33.9 465 Btuh
20 1, Tint Metal 1.13 N 13.7 33.9 465 Btuh
21 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
22 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
23 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
24 1, Tint Metal 1.13 E 13.7 33.9 465 Btuh
25 1, Tint Metal 1.13 S 13.7 33.9 465 Btuh
26 1, Clear Metal 1.13 S 16.0 33.9 542 Btuh
Window Total 125.8(sqft)4264 Btuh
Walls Ornt.Ueff.R-ValueT y p e Area X HTM=L o a d
( C a v / S h )
1 Frame - Wood - Ext (0.145)4.1/0.0 63 4.35 272 Btuh
7 Frame - Wood - Ext (0.145)4.1/0.0 79 4.35 341 Btuh
8 Frame - Wood - Ext (0.145)4.1/0.0 175 4.35 759 Btuh
Wall Total 316(sqft)1373 Btuh
Ceilings Ueff.T y p e / C o l o r / S u r f a c e R - V a l u e Area X HTM=L o a d
2 Cathedral/W /M e t a l (0.082)9.0/0.0 312 2.5 770 Btuh
Ceiling Total 312(sqft)770Btuh
Floors Ueff.T y p e R - V a l u e Size X HTM=L o a d
2 Raised - Open ( 0 . 0 8 7 )9.0 312.0 s q f t 2.6 815 Btuh
Floor Total 312 s q f t 815 Btuh
Room Envelope Subtotal: 7222 Btuh
Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.33 2496 0.30 12.8 422 Btuh
Duct load No ducts assigned to this zone.(DLM of 0.000)0 Btuh
Room #2 Sensible Room Subtotal 7644 Btuh
EnergyGauge® / USRCZB v7.0.00 Page 2
Manual J Winter Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Building Type: User
10/5/2021
WHOLE HOUSE TOTALS
Subtotal Sensible Heat Loss 21619 Btuh
Totals for Heating Ventilation Sensible Heat Loss 0 Btuh
Total Heat Loss 21619 Btuh
EQUIPMENT
1. Electric Heat Pump # M X Z 3 C 2 4 N A 2 25000 Btuh
Key: Window types - NFRC (Requires U-Factor and Shading coefficient(SHGC) of glass as numerical values)
or - Glass as 'Clear' or 'Tint' (Uses U-Factor and SHGC defaults)
U - (Window U-Factor)
HTM - (ManualJ Heat Transfer Multiplier)
Version 8
EnergyGauge® / USRCZB v7.0.00 Page 3
System Sizing Calculations - Summer
Residential Load - Room by Room Component Details
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
10/5/2021
Reference City: St. Lucie, FL Temperature Difference: 16.0F(TMY3 99%)Humidity difference: 58gr.
Component Loads for Room #1: Main
Type*Overhang Window Area(sqft)HTM L o a d
Window Panes SHGC U InSh IS O r n t Len Hgt Gross Shaded Unshaded Shaded Unshaded
2 1 Tint 0 . 5 2 , 1.13 N o No E 12.0f 2.0ft 12.0 12.0 0.0 29 69 351 Btuh
3 1 Tint 0 . 5 2 , 1.13 N o No E 12.0f 2.0ft 12.0 12.0 0.0 29 69 351 Btuh
4 1 Tint 0 . 5 2 , 1.13 N o No S 4.5ft 0.2ft 10.8 10.8 0.0 29 32 316 Btuh
5 1 Tint 0 . 5 2 , 1.13 N o No S 4.5ft 0.2ft 10.8 10.8 0.0 29 32 316 Btuh
6 1 Tint 0 . 5 2 , 1.13 B-L No S 4.5ft 0.2ft 10.8 10.8 0.0 24 26 255 Btuh
7 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 10.8 10.8 0.0 29 69 316 Btuh
8 1 Tint 0 . 5 2 , 1.13 B-L No W 9.0ft 3.0ft 10.8 10.8 0.0 24 53 255 Btuh
9 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 10.8 10.8 0.0 29 69 316 Btuh
10 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 8.3 8.3 0.0 29 69 243 Btuh
11 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 8.3 8.3 0.0 29 69 243 Btuh
12 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 8.3 8.3 0.0 29 69 243 Btuh
13 1 Tint 0 . 5 2 , 1.13 N o No W 9.0ft 3.0ft 9.4 9.4 0.0 29 69 276 Btuh
14 1 Tint 0 . 5 2 , 1.13 B-L No N 3.0ft 0.2ft 9.4 0.0 9.4 24 24 222 Btuh
15 1 Tint 0 . 5 2 , 1.13 B-L No N 3.0ft 0.2ft 9.4 0.0 9.4 24 24 222 Btuh
16 1 Tint 0 . 5 2 , 1.13 N o No E 3.0ft 0.2ft 9.4 6.6 2.9 29 69 388 Btuh
17 1 Tint 0 . 5 2 , 1.13 N o No E 3.0ft 0.2ft 9.4 6.6 2.9 29 69 388 Btuh
18 1 Tint 0 . 5 2 , 1.13 B-L No E 3.0ft 0.2ft 9.4 6.6 2.9 24 54 311 Btuh
Window Total 171 ( s q f t ) 5015 Btuh
Walls Type U-Value R-Value Area(sqft)HTM Load
Cav/Sheath
2 Frame - Wood - Ext 0.14 4.1/0.0 37.8 4.0 151 Btuh
3 Frame - Wood - Ext 0.14 4.1/0.0 49.5 4.0 197 Btuh
4 Frame - Wood - Ext 0.14 4.1/0.0 427.7 4.0 1704 Btuh
5 Frame - Wood - Ext 0.14 4.1/0.0 71.1 4.0 283 Btuh
6 Frame - Wood - Ext 0.14 4.1/0.0 157.2 4.0 626 Btuh
Wall Total 743 ( s q f t )2961 Btuh
Doors Type Area (sqft)HTM Load
1 Wood - Exterior 24.0 12.4 298 Btuh
2 Wood - Exterior 16.0 12.4 199 Btuh
Door Total 40 ( s q f t )497 Btuh
Ceilings U-Value R-ValueType/Color/Surface Area(sqft)HTM Load
1 Cath/Sngl Assem/White/Metal 0.082 9.0/0.0 672.0 2.09 1405 Btuh
Ceiling Total 672 ( s q f t )1405 Btuh
Floors R-ValueType Size HTM Load
1 Raised - Open 9.0 672 ( s q f t )1.0 644 Btuh
Floor Total 672.0 ( s q f t )644 Btuh
Zone Envelope Subtotal: 10521 Btuh
EnergyGauge® / USRCZB v7.0.00 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Climate:FL_VERO_BEACH_MUNICIPAL_A
10/5/2021
Infiltration WholehouseType A C H Volume(cuft) Wall Ratio CFM=Load
Natural 0.25 5376 0.70 22.6 397 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 1 X 230 +1200 1430 Btuh
Sensible Envelope Load: 12348 Btuh
Duct load No duct systemNo ducts assigned to this zone.(DGM of 0.000)0 Btuh
Sensible Zone Load 12348 Btuh
Component Loads for Room #2: Living Room
Type*Overhang Window Area(sqft)HTM L o a d
Window Panes SHGC U InSh IS O r n t Len Hgt Gross Shaded Unshaded Shaded Unshaded
1 1 Tint 0 . 5 2 , 1.13 N o No S 7.0ft 2.0ft 13.7 13.7 0.0 29 32 401 Btuh
19 1 Tint 0 . 5 2 , 1.13 B-L No N 4.0ft 0.2ft 13.7 0.0 13.7 24 24 323 Btuh
20 1 Tint 0 . 5 2 , 1.13 B-L No N 4.0ft 0.2ft 13.7 0.0 13.7 24 24 323 Btuh
21 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
22 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
23 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
24 1 Tint 0 . 5 2 , 1.13 N o No E 4.0ft 0.2ft 13.7 10.0 3.7 29 69 548 Btuh
25 1 Tint 0 . 5 2 , 1.13 N o No S 4.0ft 0.2ft 13.7 13.7 0.0 29 32 401 Btuh
26 1 Clear 0 . 7 4 , 1.13 N o No S 0.0ft 0.0ft 16.0 0.0 16.0 34 38 603 Btuh
Window Total 126 ( s q f t ) 4242 Btuh
Walls Type U-Value R-Value Area(sqft)HTM Load
Cav/Sheath
1 Frame - Wood - Ext 0.14 4.1/0.0 62.6 4.0 249 Btuh
7 Frame - Wood - Ext 0.14 4.1/0.0 78.6 4.0 313 Btuh
8 Frame - Wood - Ext 0.14 4.1/0.0 174.8 4.0 696 Btuh
Wall Total 316 ( s q f t )1258 Btuh
Ceilings U-Value R-ValueType/Color/Surface Area(sqft)HTM Load
2 Cath/Sngl Assem/White/Metal 0.082 9.0/0.0 312.0 2.09 652 Btuh
Ceiling Total 312 ( s q f t )652 Btuh
Floors R-ValueType Size HTM Load
2 Raised - Open 9.0 312 ( s q f t )1.0 299 Btuh
Floor Total 312.0 ( s q f t )299 Btuh
Zone Envelope Subtotal: 6451 Btuh
EnergyGauge® / USRCZB v7.0.00 Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Climate:FL_VERO_BEACH_MUNICIPAL_A
10/5/2021
Infiltration WholehouseType A C H Volume(cuft) Wall Ratio CFM=Load
Natural 0.25 2496 0.30 9.6 169 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 0 X 230 +0 0 Btuh
Sensible Envelope Load: 6620 Btuh
Duct load No duct systemNo ducts assigned to this zone.(DGM of 0.000)0 Btuh
Sensible Zone Load 6620 Btuh
The following window Excursion will be assigned to the system loads.
Windows July excursion for System 1 1548 Btuh
Excursion Subtotal: 1548 Btuh
Duct load 0 Btuh
Sensible Excursion Load 1548 Btuh
EnergyGauge® / USRCZB v7.0.00 Page 3
Manual J Summer Calculations
Residential Load - Component Details (continued)
Patricia M F Bryant
ST LUCIE BLVD
FORT PIERCE, FL 34946
Project Title:
BRYANT_WHOLE HOUSE BLOCK
Climate:FL_VERO_BEACH_MUNICIPAL_A
10/5/2021
WHOLE HOUSE TOTALS
Sensible Envelope Load All Zones 20516 Btuh
Sensible Duct Load 0 Btuh
Total Sensible Zone Loads 20516 Btuh
Sensible ventilation 0 Btuh
B l o w e r 0 Btuh
Whole House Total sensible gain 20516 Btuh
Totals for Cooling Latent infiltration gain (for 58 gr. humidity difference)1268 Btuh
Latent ventilation gain 0 Btuh
Latent duct gain 0 Btuh
Latent occupant gain (1.0 people @ 200 Btuh per person)200 Btuh
Latent other gain 0 Btuh
Latent total gain 1468 Btuh
TOTAL GAIN 21984 Btuh
EQUIPMENT
1. Central Unit # M X Z 3 C 2 4 N A 2 22000 Btuh
*Key: Window types (Panes - Number and type of panes of glass)
(SHGC - Shading coefficient of glass as SHGC numerical value)
(U - Window U-Factor)
(InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half closed
(IS - Insect screen: none(N), Full(F) or Half(½))
(Ornt - compass orientation)
Version 8
EnergyGauge® / USRCZB v7.0.00 Page 4