HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 43 Block 1 Waterstone 1820 DGL
Builder Name: ADAMS HOMES
Street: 5443 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 270.00 ft2
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(239.3 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 168.74 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33 .20.42 ft2
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.067 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 60.29
Glass/Floor Area: 0.131
PASS
Total Baseline Loads: 64.83
I hereby certify that the plans ications covere
this in
Revie of the plans and
oTjriB ST,q
calculation are compli c ergy
specifications covered by thisp
Code.
calculation indicates compliance
with the Florida Energy Code.
f
PREPARED BY:
Before construction is completed
DATE: 1715-1718-9n91 Inlinn KPnmany
this building will be inspected for
compliance with Section 553.908
I hereby certif�tktat-t�bti+ldi as designed liance
Florida Statutes.
S
with the Florida Energy Code.G,OD:
1
OWNER/AGENT:
ILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
5/6/2021 12:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
.J
FORM R405-2020 INPUT SUMMAJ1Y CHECKLIST RFP()RT
1�
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 43 Block 1 Waterstone 18 Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot # 43-1
Block/Subdivision: Waterstone
PlatBook:
Street: 5443 Lugo Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2 ____ 0.42 0 0.58
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
1820 ft2 0.11 Wood
80 ft2 0.11 Wood
5/6/2021 12:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
I-UKM K4U5-2UZU
INPUT SUMMARY
CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
-
Height
Sheathing Framing
Solar
Below
o
1
SW
Exterior
Concrete Block - Int Insul
Main
4.1 59
0 10 0
590.0 ftZ
0
0
0.6
0
2
SE
Exterior
Concrete Block - Int Insul
Main
4.1 20
0 10 0
200.0 ftZ
0
0
0.6
0
3
NE
Exterior
Concrete Block - Int Insul
Main
4.1 66
0 10 0
660.0 ftz
0
0
0.6
0
4
NW
Exterior
Concrete Block - Int Insul
Main
4.1 40
0 10 0
400.0 ftz
0
0.6
0
5
-
Garage
Frame - Wood
Main
13 27
0 10 0
270.0 ftZ
0
0.23
0.01
0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 SE Insulated Main None .25 3 6 8 20 ftZ
2 Insulated Main None .25 2 8 6 8 17.8 ftZ
WINDOWS
Orientation shown is the entered, Proposed orientation
V
Wall
Overhang
#
Ornt
ID Frame
Panes NFRC
U-Factor SHGC
Imp
Area Depth
Separation
Int Shade
Screening
1
SW
1 Vinyl
Low-E Double
Yes
0.33 0.23
N
6.9 ftZ 1 ft 4 in
0 ft 10 in
None
Exterior 5
2
SW
1 Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ft' 1 ft 4 in
0 ft 10 in
None
Exterior 5
3
SE
2 Vinyl
Low-E Double
Yes
0.33 0.31
N
7.1 ftZ 9 ft 0 in
0 ft 6 in
None
None
4
SE
2 Vinyl
Low-E Double
Yes
0.33 0.21
N
16.2 ft' 1 ft 0 in
3 ft 11 in
None
Exterior 5
5
SE
2 Vinyl
Low-E Double
Yes
0.33 0.21
N
16.2 ftZ 1 ft 0 in
5 ft 4 in
None
Exterior 5
6
SE
2 Vinyl
Low-E Double
Yes
0.33 0.31
N
13.3 ftZ 9 ft 0 in
2 ft 0 in
None
None
7
NE
3 Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ftZ 1 ft 4 in
0 ft 10 in
None
Exterior 5
8
NW
4 Vinyl
Low-E Double
Yes
0.55 0.7
N
17.8 ftZ 11 ft 5 in
0 ft 6 in
None
Exterior 5
9
NW
4 Vinyl
Low-E Double
Yes
0.33 0.23
N
32.4 ftZ 1 ft 4 in
0 ft 10 in
None
Exterior 5
10
NW
4 Vinyl
Low-E Double
Yes
0.33 0.23
N
32.4 ft' 11 ft 6 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
596 ftZ
596 ftZ
64 ft
8 ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49
218.7 .1381
7
HEATING SYSTEM
#
System Type
Subtype
Speed
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl
HSPF:8.5
34.6 kBtu/hr
1
sys#1
5/6/2021 12:14 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
Page 3 of 4
FORM R405-2020 INPl1T Sl1MMLi2Y rwpr-KI ICT RGanQT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
V
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft2
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling] Jan H Feb
Heatinf X] Jan Feb
Mar
Mar
HX
Apr
Apr
Jul
May Jun Jul
Ma X Jun rl
Au
AuSep
ri
Se
rl
Oct
Oct
Nov
Nov
Dec
Dec
Ventin [ ] Jan Feb
Mar
[X] Apr
May [ Jun Jul
Aug
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
5/6/2021 12:14 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
5443 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ft2
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ft2
6. Conditioned floor area (W)
1820
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows** Description
Area
R _
2
a. U-Factor: Dbl, U=0.33
168.74 ft2
12cDucts, location &insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
20.42 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.31
d. U-Factor: other (see details)
17.78 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.067 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:0.94
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1820.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed-Eode-se liant features.
Builder Signature: 1
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/6/2021 12:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1