HomeMy WebLinkAbout21-145A - OHS Condos-N Bldg-Bldg A- SLCPermit 2106-0287 - Report 02 10.01.21 DSIGNEDM L Engineering Inc. Consulting Engineers Threshold Inspector 2030 37th Avenue Vero Beach, Florida 32960 Phone: (772) 569-1257 Fax: (772) 569-4041 www.mlengineeringinc.com Project No. 21-145A Report No. 2 Project Manager: Building Official: Contractor: File: Mr. Gene Ross – Elliott Merrill Community Mgmt. SLC Building Department Mr. Robert Stark – Structure-Con Mr. Khris McConnell – Structure-Con Page 1 of 2 THRESHOLD INSPECTION REPORT OCEAN HARBOR SOUTH CONDOMINIUMS – 2021 BALCONY REPAIRS 4250 N. HWY A1A – (NORTH BLDG – BLDG. A) – FT. PIERCE, FL 34949 SLC BUILDING PERMIT NUMBER: 2106-0287 PROJECT NAME: Ocean Harbor South Condos – 2021 Balcony Repairs – N. Bldg. / Bldg. A DATE: October 1, 2021 CLIENT: Elliott Merrill Community Management LOCATION: Ft. Pierce, FL CONTRACTOR: Structure-Con PROJECT MGR: Mr. Khris McConnell INSPECTED BY: Todd Rhoten WEATHER: Sunny WORK INSPECTED: Unit 808 – Balcony Demo OBSERVATIONS: • Shoring has been placed at the south and east edge from the 5th floor up to the bottom of the 9th floor slab. • A temporary weather wall has been placed across both sliding glass door (SGD) openings. South-Facing sliding glass door • The SGD has been removed. • Loose concrete has been removed and corroded reinforcing bars exposed. • (6) post tension (PT) cables in total were found running parallel under the sliding glass door track in the east to west direction. (3) cables are directly under the track and the other (3) are inside the unit. • The steel reinforcing bars above and below the PT cables under the SGD track were found to have major corrosion and many of the bars will require replacement. RECOMMENDATIONS: • Contractor to contact the post tension specialist for recommendations to splice and replace the broken cables. ______________________________ _________________________________ Michael Lue, P.E. Todd Rhoten, Inspector M L Engineering Inc. Consulting Engineers Threshold Inspector 2030 37th Avenue Vero Beach, Florida 32960 Phone: (772) 569-1257 Fax: (772) 569-4041 www.mlengineeringinc.com Project No. 21-145A Report No. 2 Project Manager: Building Official: Contractor: File: Mr. Gene Ross – Elliott Merrill Community Mgmt. SLC Building Department Mr. Robert Stark – Structure-Con Mr. Khris McConnell – Structure-Con Page 2 of 2 Pic 1 (6) post tension cables under south facing SGD Pic 2 Column spall at the northeast corner of the balcony. Reinforcing bars to be repaired and replaced as per specs. Pic 3 South sliding glass door There was approximately 1-1/4” concrete cover above the PT cables