HomeMy WebLinkAboutProduct Approval 1
- a
BCIS Home Log In User Registration I ,Hot Topics Submit Surcharge Stats&Facts I Publications I Contact Us I! BCIS Site Map Links I sSearch
Florda
pr �'� Product Approval
- ,USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
® e FL# FL25621-112
Application Type Revision
l Code Version 2020
RECEIVED
Application Status Approved pl
Comments OCT 01 2021
Archived _I St.Lucie County
1 Permit
ting
9
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive REVIE"EVIVED
Palm City, FL 34990,
(772) 872-8034 � Cl WPUANC
flvalidation@yahoo.com,aT a L� IBC CUNT
Authorized Signature Richard McKuhen BOCC
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email F%P, COPY
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
?' Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
HjJ Validation Checklist- Hardcopy Received
Certificate of Independence F p L25621 R2 COI 26g napMax plywood.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
I
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
I
Summary of Products
FL# Model, Number or Name Description
25621.1 01: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4 (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R2 II 26ga SnapMax plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,l PE 81377
Impact Resistant: N/A Created Iby Independent Third Party: Yes
Design Pressure: +N/A/-97.25 Evaluation Reports
Other: Refer to evaluation report FL25621' R2 AE 26ga SnapMax plywood.edf
Created Iby Independent Third Party: Yes
i I
25621.2 02: 032 Aluminum SnapMax on Nominally 0.032" alumi i um (or thicker) SnapMax 1.0" nail strip
Plywood on 15/32" (min) plywood or 3/4" wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R2 II 032 SnapMax &LAood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,j PE 81377
Impact Resistant: N/A Created Iby Independent Third Party: Yes
Design Pressure: +N/A/-78.5 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 032 SnapMax plywood.pdf
Created Iby Independent Third Party: Yes
{
25621.3 03: 032 Aluminum 12"SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood with 12"coverage on 15/32" (min) plywood or 3/4"wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R2 II 032 SnapMax 12in Plvwood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng,l PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-69.25 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 032 SnapMax 12in PI wood.Ddf
Created Iby Independent Third Party: Yes
I
25621.4 04: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R2 II 26ga SnapMax plywood D.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,l PE 81377
Impact Resistant: N/A Created Iby Independent Third Party: Yes
Design Pressure: +N/A/-121.75 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 26ga I SnapMax plywood D.pdf
Created Iby Independent Third Party: Yes
I I
25621.5 05: 26ga SnapMax on Plywood HVHZ 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min,) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL25621 R2 II 26ga SnapMax plywood HVHZ.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng,1 PE 81377
Impact Resistant: N/A Created Iby Independent Third Party: Yes
Design Pressure: +N/A/-176 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 26ga Sna-L_pMax plywood HVHZ.
Created Iby Independent Third Party: Yes
� I
i
25621.6 05: 24ga SnapMax on Plywood 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (mi j) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R2 II 24ga SnapMax plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant: N/A Created Iby Independent Third Party: Yes
Design Pressure: +N/A/-206 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 24ga SnapMax ptywood.edf
Created Iby Independent Third Party: Yes
�cc�ti -7 n-7. now n no-),, n,, —a }..
s F,s•
AX
i
FL25621.01- R2
EXTREMEMETAL
FABRICATORS
SKILLED CRAFTERS OF METAL ROOFING SYSTEMS
26ga (min ) S [,Q1APMAX over 15/32" (min ) plywood
Extreme Metal Fabricators 1
2160 SW Poma Dr I Palm City FL 34990 I
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#10 x 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of O�.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC ,
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 I FL CA 33344
www.TimberLakeCove.com
...E'..F^'��'%
i
Digitally signed by _ No. 81377
David E Eng
'�b'ate:�2020.12.16
10t26� _
54+01'00' i `�0 STATE OF
i '�CORVDF'
/ONAL '�:
��I111111�`
i
rThis itern has been digitally
and sealed by D.E.Eng,PE,on the
date indicated.Printed copies of this
SNA
PMAX
document are not • ••
verified on • copies
Nall StripSnap Lock Standing Seam
-
2°5 6 21 `O 1 f' R 2
Underlayment: Comply with local building code or FBC 1507.1.1 wher i required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re-Roofing: This panel may be installed over a single layer of existinlg shingles as permitted
by local building code or FBC 1511, provided the existing roof meets theiconditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A• #10 x 1" fastener at 6" o c along nail strip: 86 PSF
Method B: #10 x 1" fastener at 6" o c along nail strip WITH sealant: 97 25 PSF
For Method B, use continuous 3/16" bead of Bostik 915 sealant or similar:
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre-punched slots.
Technical Documentation :
I
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D8133.01-450-18, as referenced in FL 17022.05-R7
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ), as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• .UL 1897 - Uplift test for roof covering systems
I
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for iproject specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a 'financial interest in any company
manufacturing or distributing products under this evaluation. The same entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the',scope of thiis evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC'1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
•R •
CATORS
EXTREMEMETAL
� � t° �
Instructions:
Select the appropriate load table that applies to the
structure in question.
2 2 3
Determine the design wind speed for the project
location. 2 1 1 2
Use the attachment method indicated for that 2
windspeed within each roof zone. 21 2 3 a
2 ,1 2 a
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. 1 2 3
For the load tables below, the worst case was taken 2
for each zone and reported using the standard zones 2 1 1 2
1-2-3: j
Zone 1 includes zones 1 and 1' I I3 a
Zone 2 includes zones 2e, 2r, and 2n �aL HIPIROOF GAEILEROOF --+a
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple IV.OF LEAST HOIZONTAL DIMENSION OR B.M,WHICHEVER IS SMALLER.BUT NOT
T LE SS THAN EITHER 4Y.OF LEAST HORIZONTAL DIMENSION OR 3FT(0.9M).
scheme, at the expense of some design efficiency. OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE°ODE
Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional.
METHOD A METHOD B
NR: NOT RATED
I
FEMALE LEG SNAPS �FEMALE LEG SNAPS CONSULT DESIGN
ONTO MALE LEG ONTO MALE LEG PROFESSIONAL AS
I
SEALANT APPLIED TO
BASE OF MALE LEG NECESSARY
fi10 FASTENER #10 FASTENER
AT 6"O.C. AT 6"O,C.
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B, C,or D exposurel area
Have either a flat roof, or gable/hip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL25621.01: 26 a Sna Max on 15/32" plywood FL25621.01: 26 a Sna I Max on 15/32" Plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 .1.70. 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A' A A !A A A B
Zone 2: A A A A A A A A B Zone 2: A A A A �B wal
Zone 3: A A A A A A B Zone 3: A A' A B
I
I
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 70,hip roof with Have either a flat roof less than . J hip roof with
max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12&12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL25621.01: 26 a Sna Max on 15/32! I ood FL25621.01: 26 a SnailJlMax on 15/32" plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 1140 150 160 1_70. 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A All A A A A A B
Zone 2: A A A A A A A A A B Zone 2: A Ai A A iA B
Zone 3: A A A A A A A B Zone 3: A A! A B
y • - •
EXTREMEMETAL
_ II i