HomeMy WebLinkAboutProduct Approval (2) BCIS Home i Log In t User Registration i Hot Topics ; Submit Surcharge i Stats&Facts ; Publications Contact Us ; BCIS Site Map Links iN+Search 1
Florida
r
Product Approval
u�
USER:Public User
P
d.,,�„i,..rt
c ns�EIVED
Product Approval Menu>Product or Application Search>Application List>Applica to i o >Application Detail
FL# FL5259 IT08 ZOZO
r 3
Application Type Revision
St.Lucie County
2 �a Code Version 2020 Permitting
Application Status Approved
. � Comments
Archived
.: u®py
' Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext 242
,x malpert@polyglass.corri
t : Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
< i. Address/Phone/Email 1111 West Newport Center Drive
F- Deerfield Beach, FL 33442
866 802-8017
uspolyglasstechnical@polyglass.com
V Y'
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnica)@polyglass.com
f.`
Category Roofing
Subcategory Underlayments
mot:;
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
U Evaluation Report-' Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
?s+` the Evaluation Report
Florida License PE-59166
s ; Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 1O/21/2022
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
c .
Y
Certificate of Independence FL5259 R31 COI_2020 Ol COI_NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
N ASTM D1970 2015
ASTM D226 2009
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...rxQEK%2fPlg53SOJbxti0ftKayE8OIA1Vriw1ejHLVwh3DQ%3d%3d 1018/21,2:50 PM
Page 1 of 2
"i ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
-- ASTM D6222 2011
ASTM D6509 2015
FM 4474 2011
FRSA/TRI,Sixth Edition 2018
UL1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/22/2020
Date Validated 10/26/2020
Date Pending FBC Approval 11/01/2020
f.
Date Approved 12/15/2020
Date Revised 12/21/2020
Summa of Products - - — - _-
FL# Model,Number or Description
Name
5259.1 Polyglass Roof Roofing underlayments
Underlayments
Limits of Use Installation Instructions
3g Approved for use in HVHZ: No FL5259_1131 II_2020 09 30 FINAL_ER_POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside HVHZ:Yes R31.Ddf
{ Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this Evaluation Reports
application relates to one particular FL5259_R33 AE 2020_0_30_ IF NAL ER_POLYGLASS UNDERLAYMENTS_ LF 5259_
underlayment system for use in tile roof R31.Ddf
systems. Refer to ER Section 5.8.3 for Created by Independent Third Party:Yes
other systems and associated maximum
design pressures. 2.) Refer to ER Section
a 5 for other limits of use.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
N" The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
'T" personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
. i
Credit Card
Safe
https://fioridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...rxQEK%2fPlg63S0JbxtlOftKayE8QA1Vriw1ejHLVwh3DQ%3d%3d 1018/21,2:50 PM
Page 2 of 2
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Polyglass USA, Inc. Evaluation Report P12060.02.09-1127
1111 West Newport Center Drive F1.5259-1331
Deerfield Beach, FL 33442 Date of Issuance:02/24/2009
(954) 233-1330 Revision 27:09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
I
use of the product under the Florida BuildingCode and Florida Building Code Residential Volume. The products described
g
herein have been evaluated for compliance with the 7tb Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assuri nce Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate o the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review,of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words)"NEMO I etc. (Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done ini its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the�Building Official.
I
This Evaluation Report consists of pages 1 through 17.
Prepared by:
!. S•\i.it �i
Robert J.M. Nieminen P.E. • T•._..>•o..-:
Florida Registration No.59166,Florida DCA ANE1983 "%ems. o'` ' The facsimile seal appearing was authorized by Robert Nieminen,P.E.on
09/30/2020. This does notlserve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE: I
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates. 1
2. NEMO ETC,LLC is not awned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or!design guidance unless retained specifically for that
purpose.
02019 NEMO ETC,LLC
I
I
I
ONEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
•D
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1/R905.1.1 Material standard ASTM D226 2009
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
1507.11.2/R905.11.2 Material standard ASTM D6164 2011
1507.11.2/R905.11.2 Material standard ASTM D6222 2011
1507.11.2/R905.11.2 Material standard ASTM D6509 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Enti Examination Reference Date Enti Examination Reference Date
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) TAS 103 PLYG-SC12115.08.17 08/08/2017
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) TAS 103 PLYG-SC13035.08.17 10/31/2017
ERD(TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 FM(TST 1867) Wind Uplift 3004091 01/12/2000
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ICC-ES(EVL 2396) IBC Compliance ESR-1697 04/01/2019
ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 M-D(CER 1592) HVHZ Compliance NOA 17-0614.22 07/06/2017
ERD(TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 MTI(TST 2508) ASTM D4798 JX20H7A 04/01/2008
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 NEM0(TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018
ERD(TST 6049) ASTM D4977 P11030.11.09-3 11/30/2009 NEM0(TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019
ERD(TST 6049) ASTM D1970 P33360.06.10 06/25/2010 NEM0(TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019
ERD(TST 6049) TAS 103 P33370.03.11 03/02/2011 NEMO(TST 6049) ASTM D6222 4S-PLYG-18-002.05.19-C 05/20/2019
ERD(TST 6049) Tensile Adhesion P33370.04.11 04/26/2011 NEMO(TST 6049) ASTM D1970 4j-PLYG-19-5SUDL-00.A 09/10/2019
ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 NEMO(TST 6049) TA5 103 4S-PLYG-18-004.10.19-G 10/08/2019
ERD(TST 6049) TAS 103 P40390.08.12-1 08/06/2012 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-1 10/08/2019
ERD(TST 6049) Tensile Adhesion P40390.08.12-2 08/07/2012 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-L 10/09/2019
ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 NEM0(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-01.A 10/10/2019
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEM0(TST 6049) TAS 103 4S-PLYG-18-004.12.19-F 12/18/2019
ERD(TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEM0(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-02.A 01/02/2020
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 NEM0(TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.H 01/14/2020
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEMO(TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.K 01/14/2020
ERD(TST 6049) ASTM D6164 P37590.03.13-3A 05/06/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.01.20.A 01/16/2020
ERD(TST 6049) ASTM D6509 P37590.03.13-1-R1 06/26/2013 NEMO(TST 6049) ASTM D6164 4S-PLYG-18-004.01.20.B 01/16/2020
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO(TST 6049) ASTM D6222 4S-PLYG-18-002.12.19-K-Rl 01/07/2020
ERD(TST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO(TST 6049) TAS 103 PLYG-SC15855.05.20.A 05/29/2020
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 NEM0(TST 6049) TAS 103 4j-PLYG-20-SSUDL-01 07/06/2020
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 NEM0(TST 6049) ASTM D6222 4q-PLYG-I9-SSMBB-05.A 07/23/2020
ERD(TST 6049) 30/90 physicals P45270.05.14 05/12/2014 NEMO(TST 6049) ASTM D4798/D1623 4j-PLYG-I9-SSUDL-05.A 09/10/2020
ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 NEMO(TST 6049) ASTM D1970 4j-PLYG-20-SSUDL-05.A 09/30/2020
ERD(TST 6049) Tensile adhesion 6020.09.14-6 09/08/2014 NEMO(TST 6049) TAS 103 4j-PLYG-20-SSUDL-05.0 09/30/2020
ERD(TST 6049) Tensile adhesion P46520.10.14 10/03/2014 NEMO(TST 6049) TAS 103 4j-PLYG-20-S5UDL-11 09/30/2020
NEIVIO ETC,I.I.C. Evaluation Report 1312060.02.09-1127
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 2 of 17
i
NNEMOjetc.
Enti Examination Reference Date Enti Examination Reference Date
ERD(TST 6049) ASTM D1970/D4798 P43290.30.14 10/17/2014 PRI(TST 5878) Tensile Adhesion PRIO1111 04/08/2002
ERD(TST 6049) TAS 103 PLYG-SC7550.03.15 03/24/2015 PRI(TST 5878) TAS 103 PUSA-018-02-01 07/14/2003
ERD(TST 6049) Tensile adhesion P40390.04.15 04/03/2015 PRI(TST 5878) TAS 103 PUSA-035-02-01 09/29/2006
ERD(TST 6049) TAS 103 P44360.10.14-R1 05/18/2015 PRI(TST 5878) TAS 103 PUSA-055-02-02 12/10/2007
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 PRI(TST 5878) ASTM D6222 PUSA-061-02-02 01/28/2008
ERD(TST 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016 PRI(TST5878) ASTM D6164 PUSA-088-02-01 07/29/2009
ERD(TST 6049) Tensile adhesion PLYG-SC10130.06.16-2 06/27/2016 Polyglass USA P/L Affidavit Mlule-Hide Cross Ltg 03/01/2008
ERD(TST 6049) TAS 103 PLYG-SC10130.06.16-3 06/27/2016 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
ERD(TST 6049) ASTM D1970/D4798 PLYG-SC8080.07.16 07/16/2016 UL(QUA9625) Quality Control Service Confirmation(FL) 09/13/2018
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 UL(QUA9625) Quality Control Service Confirmation(TX) 11/07/2019
ERD(TST 6049) TAS 103 PLYG-SC13040.12.16 12/27/2016 UL(QUA9625) Quality Control Florida BCIS Current
' '•DDESCRIPTION:
Product Material Standard Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet
4.3 Elastoflex S6 G ASTM D6164 FL, PA Polyester-re'i,nforced,SBS modified bitumen cap sheet
FRSA/TR109-18
4.4 Elastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRl 09-18
4.5 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.6 HydraGuard Tile Pro ASTM D1970 FL Nominal 60 mil thick dual-layer rubberized asphalt
FRSA/TRI 09-18 waterproofing membranejfiberglass reinforced,with a
polyester fabric surface
4.7 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI 09-18
4.8 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
(FR) FRSA/TR109-18
4.9 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet"in the
"Two Ply System"from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
4.10 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP'modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied"Cap Sheet"in the
Two Ply System from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth
Edition beneath mechanically fastened tile roof systems
4.11 Polyflex SA P ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TR109-18
4.12 Polyflex SA P FR ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRl 09-18
4.13 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet
4.14 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet
NEMO ETC,LLC. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 3 of 17
i
OMEMO etc.
4. PRODDESCRIPTION'
Product Material Standard Plant(s) Description
4.15 Polystick IR-Xe ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.16 Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 PA,TX membrane,glass fiber reinforced,surfaced with
polyolefinic film surface
4.17 Polystick MU-X ASTM D19701 FL, NV, PA Nominal 54-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polypropylene film surface
4.18 Polystick TU Max ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane with a 190 g/m'polyester fabric surface
4.19 Polystick TU P FRSA/TRI 09-18 FL, PA,TX Nominal 130-mil thick rubberized asphalt waterproofing
membrane,glass-fiber/polyester reinforced,with a
granular surface
4.20 Polystick TU Plus ASTM D1970 FL, PA,TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane,glass fiber reinforced,with a polyester fabric
surface
4.21 Polystick XFR ASTM D1970 NV,TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane,glass fiber reinforced,surfaced with a
textured film surface
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEW ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for
any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
1 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard
laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 4 of 17
I 1
i
I
NMEMO etc.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt Clay and Concrete Tile Metal Slate or i Wood
Underlayment Shingles (1507.3) Slate-Type j
(2507.2)
Mechanical Adhesive- Panels Shingles Shingles Shingles
Shakes(1507.9)
Attach Set (1507.4) (1507.5) I! (1507.7J (1507.8)
Yes Yes Yes Yes Yes Yes Yes Yes
Elastobase (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to' (Alternate to (Alternate to D226, (Alternate to D226,
D226,Type 11) See 5.8.3) See 5.8.3) D226,Type 11) D226,Type 11) D226,Type II) Type II) Type 11)
Yes Yes Yes Yes Yes Yes Yes Yes
Elastobase P (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate tol (Alternate to (Alternate to D226, (Alternate to D226,
D226,Type 11) See 5.8.3) See 5.8.3) D226,Type 11) D226,Type 11) D226,Type II) Type 11) Type 11)
Yes Yes
Polyglass Base No (as Base Sheet, (as Base Sheet, No No No No No
See 5.8.3) See 5.8.3)
Yes Yes
Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No I No No
See 5.8.3) See 5.8.3) I+
Elastoflex S6 G No Yes Yes No No No No No
(See 5.6.1)
Elastoflex S6 G FR No Yes No No No No I No No
HydraGuard Dual Pro Yes No No Yes Yes Yes Yes Yes
(joint strips,1507.1.13 Goint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
HydraGuard Tile Pro Yes Yes Yes(See 5.6.1) Yes Yes Yes Goint strips,15oz1.1.3 Goint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Mule-Hide SA-APP Cap Sheet No Yes Yes(See 5.6.1) No No No No No
Mule-Hide SA-APP Cap Sheet(FR) No Yes Yes No No No No No
(See 5.6.1)
Polyflex G No Yes Yes No No No No No
(See 5.6.1)
Polyflex G FR No Yes No No No No No No
i
Polyflex SA P No Yes Yes No No No No No
(See 5.6.1)
Polyflex SA P FR No Yes Yes No No No No No
(See 5.6.1)
Yes Yes
Polystick IR-Xe Yes No No No No Yes Goint strips,1507.1.1.3 Goint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
Polystick MTS Plus Yes Yes No Yes Yes Yes
(Joint strips,1507.1.1.3 Goint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3j
Yes Yes
Polystick MU-X Yes No No Yes Yes Yes J Goint strips,1507.1.1.3 Goint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes Yes
Polystick TU Max No Yes Yes Yes No
(See 5.6.1) � (Joint strips,1507.1.1.3 Goint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Polystick TU P No Yes Yes No No No Yes Yes
(See 5.6.1) (Joint strips,1507.1.1.3 Goint strips,1507.1.1.3
i. /R905.1.1.3) /R905.1.13)
Yes Yes Yes
Polystick TU Plus Yes Yes Yes Yes Yes 1
(See 5.6.1) i I Goint strips,1507.1.1.3 Qoint strips,1507.1.1.3
l /R905.1.1.3) /R905.1.1.3)
Yes Yes
Polystick XFR Yes Yes No Yes Yes Yes
Goint strips,1507.1.1.3 Goint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 fH EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 5 of 17
NNEMO I etc.
5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS2
Underlayment Adhesive Florida Product Approval
Polystick TU Max or Polystick TU Plus DAP Foam"Touch'n SealStormBond Roof Tile Adhesive" FL14506
HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or Polystick Dupont"Tile Bond"Roof Tile FL22525
TU Plus Adhesive"
Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA- ICP Adhesives and Sealants
APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, "Polyset®AH-160" FL6332
Polystick TU P or Polystick TU Plus
Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA- ICP Adhesives and Sealants
APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, "Polyset®RTA-1" FL6276
Polystick TU P or Polystick TU Plus
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
HydraGuard Dual Pro, (Optional)ASTM plywood,OSB,Southern Yellow Pine or Huber Engineered
HydraGuard Tile Pro,Polystick IR- Deck/ D41 Woods"ZIP System"Panels
Xe,Polystick MTS Plus,Polystick sheathing
Y y ASTM D41 structural concrete
MU-X,Polystick TU Max, self- ASTM C1289 Type II Class 1 polyisocya n u rate,ASTM
Polystick TU P,Polystick TU Plus, adhering Insulation (Optional)ASTM C1289 Type V polyisocyanurate-composite,DensDeck
Polystick XFR,Mule-Hide SA-APP D41 or WB-3000
Prime or SECUROCK Gypsum-Fiber Roof Board
Cap Sheet,Mule-Hide SA-APP
Cap Sheet(FR),Polyflex SA P or Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P or Mule-
Polyflex SA P FR Hide Nail Base
Deck ASTM D41 structural concrete
Elastoflex 56 G or Elastoflex S6 G Insulation (Optional)ASTM DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
FR hot asphalt D41
Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P,Mule-
Hide Nail Base or Polyglass G2 Base
Deck ASTM D41 structural concrete
torch- Insulation (Optional)ASTM DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
Polyflex G or Polyflex G FR applied D41
Base Sheet N/A Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass
G2 Base or Polyglass Base
2 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FLS2S9-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 6 of 17
� ! 1
i
ONEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets- not less than FBC
1507.1.1 or R905.1.1. 1 1
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturers installation instructions, but—
for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition Appendix A,Table 1(for Two-
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A for the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-52.5 psf: I.
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min.4-inch wide strips of Elastoflex SAN over all OSB joints
Base Ply: Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#2 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),PolyfleX SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%" ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction'of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS Plus,self-adhered. I9
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1'/0" ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 7 of 17
I
ONEMOletc.
#5 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#6 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
PolystickTU Max,PolystickTU P or PolystickTU Plus,self-adhered.
#7 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#8 All other direct-deck,adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29(February 2020)for enhancements.
#9 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#10 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#11 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
MEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 8 of 17
° I
i
IRMEMO etc.
#12 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Havi I
g Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),PolyflexiSA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#13 Maximum Design Pressure=-45 psf*:
Deck: Min:19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt.
#14 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#15 Maximum Design Pressure=-45.0 psf: I:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflexx SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#16 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt.
#17 Maximum Design Pressure=-45.0 psf: j
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction. '
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#18 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap orl poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
I
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-RZ7
Certificate of Authorization#32455 74H EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 9 of 17
ONEMO I etc.
#19 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#20 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#22 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#23 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#25 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
NEMO ETC,U.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 10 of 17
i
NEMO l etc.
#26 Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied under/ayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equallylspaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#27 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project require I ents to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: (Optional)PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#28 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet(project require I ents to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#29 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meetlproject requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width direction of the sheet. I 1
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#30 Maximum Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Ha i ing Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
5 acin : 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c. h p g p at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied for Polyflex G,torch-applied.
#31 Maximum Design Pressure=-90 psf: j
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#32 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction'of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap orlpoly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
i
NEMO ETC,LLC. I Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 11 of 17
NMEMO etc.
�
#33 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#34 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underloyment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with CMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#35 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),PolyflexSA P,PolyflexSA P FR,PolystickTU Max,Polystick
TU P or PolystickTU Plus,self-adhered.
#36 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#37 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#38 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 12 of 17
I
' I
ONEMO etc.
#39 Maximum Design Pressure=-97.5 psf: j
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates. J
Base Ply: (Optional)Polystick MTS Plus,self-adhered. JJ
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#40 Maximum Design Pressure=-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#41 Maximum Design Pressure=-97.5 psf: .
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet 1project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#42 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners I ISpacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#43 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) I!
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate'installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
I
#44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate linstalled 180.into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt.
I
I
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#132455 fH EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 13 of 17
ONEMO I etc.
#45 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#46 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS Plus,self-adhered
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#47 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#48 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#49 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#50 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#51 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
NEMO ETC,LLC. Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 1"'EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 14 of 17
ONEMOjetc.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Prepared Roof Cover Maximum
Underlayment I: i
Installation Type Exposure(days)
Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base I' Mechanically attached 30
Polystick IR-Xe or Polystick MU-X Mechanically attached 90
HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick MTS Plus,Polystick TU Max,Polystick
TU P,Polystick TU Plus or Polystick XFR IAny type per Table 1 I ) 180
Elastoflex S6 G,Elastoflex S6 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Adhesive-set tilelroof system 180
Sheet(FR),Polyflex G,Polyflex G FR,Polyflex SA P or Polyflex SA P FR Mechanicallylattached UNLIMITED
5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direelt-deck We roof assemblies,the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens durl 1 g loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Staging Slope
Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) Prohibited without battens
HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) { 7:12
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) I 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS Plus Flat 6-tile stack(4 over 2) 5:12
Lugged 6-tile stack(4 over 2) 4:12
Flat 6-tile stack(4 over 2)or 10-tile stack I 7:12
Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat or Lugged 6-tile stack(4 over 2) 7:12
Polystick TU Plus
Flat or Lugged 10-tile stack 6:12
Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens
I
I
I
I
I
I. 1
MEMO ETC,I.I.C. j Evaluation Report P12060.02.09-R27
Certificate of Authorization 532455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 15 of 17
I
I
NEM01 etc.
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM D226,Type
II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed,and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule-Hide SA-APP Cap
Sheet or SA-APP Cap Sheet(FR), self-adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G
FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table
1
6.3.2 Tile Applications:
6.3.2.1 Elastobase(poly-film top), Elastobase P(poly-film top)and Mule-Hide Nail Base are limited to use as a mechanically attached
base sheet in the"TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth
Edition,followed by Polystick MTS Plus,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick XFR,Polyflex SAP,Polyflex
SA P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered or Polyflex G or Polyflex G FR,torch-applied. Tile
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.3.2.2 Elastobase(sanded-top)and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the"TWO-
PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by
Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380),asphalt-applied or Polyflex
G or Polyflex G FR,torch-applied. Tile roof installation method is limited by the selected Cap Sheet,as set forth in Table 1.
• When Elastobase(sanded-top) or Elastobase P(sanded-top)is followed by asphalt-applied Elastoflex S6 G, Elastoflex S6
G FR or FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380), refer to FRSA/TRI,Sixth Edition,Appendix A,Table 1
or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase(sanded-top)or Elastobase P(sanded-top)is followed by torch-applied Polyflex G or Polyflex G FR,refer
to Section 5.8.3.2 herein for attachment requirements.
6.4 HydraGuard Dual Pro,HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,
Polyflex SA P FR,Polystick IR-Xe, Polystick MTS Plus,Polystick MU-X, Polystick TU Max,Polystick TU P,Polystick TU Plus or
Polystick XFR:
6.4.1 General:
All seal-lap seams (selvage laps) must be firmly rolled with a V
in accordance with Polyglass requirements to ensure full ' '
contact and adhesion. For HydraGuard Dual Pro and '' ''"'
j HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern(the sheet will overlap the fabric).
View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
NEMO ETC,U.C. Evaluation Report P12060.02.09-RZ7
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 16 of 17
*NEM01 etc.
6.4.2 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt, Elastobase, Elastobase P or
Mule-Hide Nail Base,the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile Applications(excludes HydraGuard Dual Pro,Polystick IR-Xe and Polystick MU-X): I
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forthi in FRSA/TRl Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi-Ply Underlayment Systems:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro,Polyflex SA P,Polystick MTS Plus,Polystick MU-X,Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanicallv attached prepared roof
systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired. I
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive-set tile systems. Limits of use are those associated with the top-layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply
System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile'Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
I
6.6 Polyflex G or Polyflex G FR:
6.6.1 Shall be installed in compliance with requirements as an alternate to the"Heat Applied Cap Slieet"in the"Two Ply System"in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations. {
7. BUILDING PERMIT •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 611320-3 QA lrequirements. Refer to Section
4 herein for products and production locations having met codified material sti'ndards.
QUALITY9.
UL LLC—QUA9625;(414)248-6409; Karen.buchmann@ul.com
-END OF EVALUATION REPORT-
NEMO ETC,U.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 17 of 17
I