Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction:
Permit #:
Job Information`
Builder: K Hovnanian Community: `�Lot: i
Addresse 0Unit.
City:�� r.� �� L ; State: FL Zip: 9t/ c `
House S.F: I i
Avg. Ceiling Height:
Total Volume:
Air Li kalge Test Result$ passing results must meet either the Perf ormonce, Proscriptive, or E/1v/ Method
0PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate or not exceeding i air
change per hour at a pressure of 0.2�inch w.g. (50 pascals) In climate zones 1 and 2.
0 PERFORMANCE OR ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding the selected ACH(50) value, as shown on FORM R405"2017 (performance) or R4062017 (ERR), section labeled as infiltrations sub*
section' ACH.
ACH(50) specified on Form R4055 2017WEnergy Calc (Performance) or R4062017 (4ERI); ,
Pressure & Flow Data (For Single Point)
Test #
House Pressure: Pascals
Flow: CFM (50)
Ring Used
ACH50 = CFM (50) x 60 / House Volume = i. Method for calculating_ building volume:
[;?PASS FAIL 0 Retrieved from architectural plans
Code Software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation must
; Field measured and calculated
be verified by building department.
Testing, Testing shall be conducted in accordance with ANSI/RESNET/iCC 380 and reported at a pressure or 0.2 inch w.g, (50 pascals), resting shall be
conducted by either individual as defined in Section 553,593(5) or (7), Florida Statues, or individuals licensed as set forth in Section 4891o105(3)(f), (g), or (1) or
an approved third party: A written report of the results of the test shall be signed by the party conducting the test and provided to the code offlclal. Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope,
Testing Company
Company Name: RunBrook, LLC Phone: 561-510-5715
1 hereby verify that the above Air Lepk, results are in accordance with the 2017 6" Edition Florida Building Code
Energy Conservation requiremen/o2rd'nto e compliance method selected above.
Signature of Tester: Date of Test: Ij
Printed Name of Tester: k Costagliola
License/Certification #: G� 3243649 _ Issuing Authority: RESNET
RUNBROOK
Duct Leakage Test Report
CREEf'�': BUILDING BSc FC�I�:C�''�`��"'�;S�"It�{1
sidenti Real Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
jurisdiction, Permit
,fob Information
Builder: K Hovnanian Community: rr -11 Lot:
Address: 131 F�3� Unit:
M„2..
City:470)f+� +`.. State, FL Zip: 5LKy S
IF IF I I
Duct Leakage Test Results
I.
IF I IF
.......... ............... ......
System 1 Prescriptive Method cfm25 (Total)
y cfm25
To qualify as "substantially leak free" Qn must be less than or equal to
System 2 cfm25 0.04 if air handler unit is installed. If air handler unit is not installed,
Qn Total must be less than or equal to 0.03. This testing method
System 3 meets the requirements in accordance with Section R403.3.3.
cfm25w....:.......... w .........:.._..... _H.....,... ...... .. __........w.... _H
Sum of any
additional systems cfm25
0 Performance l ERI Method cfm25 (out or Total)
Total of all To qualify using this method, Qn must not be greater than the
systems cfm25 proposed duct leakage Qn specified on Form R405-2017 or R406-2017.
Qn
Total of all Total Conditioned Leakage Type selected on Form Qn specified on Form R405-2014
systems S u Footage R405-2017 (Energy Calc) or R406-2017 (Energy Caic) or 406-2017
IF
PASS FAIL
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (1), Florida Statutes.
Testing Company ,
RunBrook, LLC 561-510-5715
Company Name: Phone:
I hereby verify that the above duct leakage testing r ul f are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements according to the co is e method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
Frank Costagliola