HomeMy WebLinkAboutColton Residence PoolUES Project No:
Workorder No:
Report Date:
3310.2100340.0000
248460-3
10/13/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:Melissa Colton UES Technician:Johnnie Smith
2279 Keen Road
Fort Pierce, FL 34946
Date Tested:10/08/2021
Project:CMT Colton Residence Pool
2279 Keen Rd, Fort Pierce, St Lucie County, FL 34946
Type of Test:
Area Tested:Pool Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:AASHTO T180 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 98% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 S Side 0-1 ft 120.6 11.0 118.1 9.9 98 Pass
2 E Side 0-1 ft 120.6 11.0 117.9 9.9 98 Pass
3 N Side 0-1 ft 120.6 11.0 119.0 10.7 99 Pass
4 W Side 0-1 ft 120.6 11.0 120.2 11.1 100 Pass
Remarks:Test #1:
1-2’, 2-3’, 3-4', 4-5' HCP=50+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of
the soil.
Permit #: 2104-0669
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G. Abubakar,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.