Loading...
HomeMy WebLinkAboutRevisions; Add Bench Change to new formed BenchOFFICE USE ONLY: DATE FILED: 08/23/2021 REVISION FEE: PERMIT # 2014-0363 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 LOCATION/SITE ADDRESS: 12772 NW MARINER CT PALM CITY FL APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION FILE COPv DETAILED DESCRIPTION OF PROJECT REVISIONS: ADD A BENCH CHANGE TO NEW FORMED BENCH ETC SEE ATTACHED ENGINEERING FOR DETAILS CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CPC1456929 BUSINESS NAME: FAMILY POOLS INC QUALIFIERS NAME: FRANK RUSSO ADDRESS: 873 SWS MACEDO BLVD CITY: PORT ST LUCIE STATE: FL PHONE (DAYTIME): 7728788452 OWNERBUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: M RANDALL RODGERS ADDRESS: 1801 HAZELWOOD DRIVE CITY: FT PIERCE PHONE (DAYTIME): 772201163 SLCCC: 9123109 Revised 06130117 STATE: FL ST. LUCIE CO CERT. #: ZIP: 34983 FAX: 7727859558 FAX: rax: �. x y f Wi p ZIP: ZIP: 34982 ............. POOL LIGHT JUCTION Box YARD BY POOL PATIO EQUIPMENT WATER LEVEL 1116611121 Jill 12 VAC FROM UNDERWATER POWER SUPPLY LIGHT SIZE AS DETERMINED BY LICENSED ELECTRICIAN POOL FINISH 1. PVC SCHEDULE 40 PVC SLEEVE CONDUIT NO BONDING OR GROUND REQUIRED NICHLESS UNDERWATER LIGHT DETAIL (NO SCALE) WHEN PROVIDE SHALL BE AT 20" MAX BELOW THE WATERLINE AN VISUALLY SET APART FROM POO SWIMOUTS < NO MAX= MISC. NOTE 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2, HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL Im (n 04 44 A* .'A CA 4'4 STEP DETAIL 1. TREAD IS MIN OF 10* WIDE. 2. BOTTOM & TOP RISERS MAY VARY IN HEIGHT 3. RISER NOT GREATER THAN 12' EXCEPT BOTTOM STEP WHERE DEPTH IS 4' OR GREATER 4. ALL STEPS TO BE SOLD GUNITE 3000 P.S.I. 16" mW(Typ)'.- STEPS (NOCAL) 06 PSI. . EXISTING DECK ----------------- I 12" #3 REBAR DOWELS EPDXY SET 12" O.C. NEW TO EXISTING DECK (NO SCALE) .................. * .................... * ............ FYSTINC, P001 SHF[ I 12"#3 DOWELS EPDXY SET-3 EMBEDMENT 12" O.C. (MIN) NEW POOL & SPA CONSTRUCTION NEW TO EXISTING DETAIL (NO CAL) EXISTING REBAR ,Y- #8 SOLID COPPER WIRE W/ APPROVED: CLAMPS NEW CAP TILE WHERE APPLICABLE NEW 6" SPA WALL EXTENSION-3,000 PSI GUNITE 12" #3 REBAR DOWELS EPDXY SET 12" O.C. W/(1)#3 HORIZONTAL NEW 6"x6" TILE EXISTING DECK EXISTING SPA SHELL SPA WALL EXTENSION ( NO SCALE-) T