Loading...
HomeMy WebLinkAboutLetter; Siding Products8385 White aak Ave. C'AE Rancho Cucamonga, CA 91730 RECEIVED Phone: 626.409.8650 SEP 3 0 2021 St. Lucie County Permitting Project No.: 2001-14.3 Date: December 14, 2020 Rathisha Sabaratnam, Sr. R&D Technical Services Specialist James' Hardie Building Products, Inc. 10901 Elm Ave. Fontana, CA 92337 Subject: NOA 20-0730.06 for Compliance with 2020 Florida Building Code (7th Edition) Dear Rathisha, At your request in reference to the Miami Dade Checklist requirements, based on my review of applicable sections of the 2020 Florida Building Code and the submitted test reports, it is my professionalopinion that the siding products listed in the attached NOA meet the requirements of the 2020 Florida Building Code. At your request, based on my review of applicable sections of the 2020 Florida Building Code and the submitted test reports for the subject products listed in the above referenced NOA, it is my professional opinion that. the siding products listed in the NOA meet the requirements of the 2020 Florida Building Code. Attached are the updated stamped product installation drawings. The following are referenced standards in the 2020 FBC: (1) Wood: AWC NDS-2018 & SDPWS-2015 (2) Structural Design: A$CE 7-16 (3) Concrete: ACI 318-14 (4) Masonry: TMS 402-2016 (5) Structural Steel: AISC 360-16 and 2017 AISC Steel Construction Manual (6) Cold -formed Steel: AISI 100.46 (7) Aluminum: AA ADM 1-2015 In addition, I make the following Statement of Independence: (a) I, V. Andrew Tan, do not have nor intend to acquire or will acquire any financial interest in any company manufacturing or distributing products for which evaluations are issued. (b) CAE is not owned, operated or controlled by any company manufacturing or distributing products we.evaluate or inspect. ' (c) CAE does not have, nor will it acquire financial interest in any company manufacturing or distributing products for which reports are being issued. (d) CAE does not have, or will it acquire a financial interest in any other entity involved in the approval process of the product. - Please feel free to contact me %��ti�s/thank you again for your business. Efp E Al Respectfully submitted, zz. F CAE, Inc. = No. 81662 1', a 1 i STAtTEOF ' Aj �TOfVAL V. AndreWTan;-F'.E., exp. 2/28/210f 111 I tt 0 Principal Engineer Attachments. (1) NOA 20-0730.06 Fastener Spacing per Florida Building Code Section 2322-3 ........... Cladding Framing ---------- ------------------------------- Fastener Spacing per Florida Sheathing Building Code Section 2322.3 0.75in . ... ... ........ ....... . PRODUCT REVISED as i;amplyl.9 with the Florida Ix Building Code ------- 20-0730.06 ----------------- -- Eitpl—ficm Date OSIO112022 BY Miami -Dade Product Control ------- -------- ---- 81§62 58.25in. ASTAL E.,-n;: % FRAF At NG • NOMINAL 2"X 4S-P-F WOOD STUDS 16"O.C. FASTENED WITH 3-10'16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 518!'THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING BUILDING CODE SECTION 2322.3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION CLADDING . PLANKS OVERLAP 1-1/4' James Hardie Building Products, Inc. . THE EXPOSURE IS s8-1/4" 10901 Elm Avenue . THE PLANKS ARE FACE NAILED WITH 2-1/2" LONG, 0.223' HEAD DIAMETER, 0.092- SHANK DIAMETER, CORROSION-�- MR- Fontana, CA 92337 RESISTANT SIDING NAILS, PLACED 314- UP FROM THE Phone: 909-356-6300 [ZE FSCM NO DVVG NO REV BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Fax 909-427-0634 sA PNL-PLK-SOFF 2 Creator. E. Gonzales I.. I- = 1--0- Date: 9129=20 ISHEET 6 OF 12 16 in. OC i� Stud Spacing at i6" O-C. WALL SEE —PRODUCT REVISED 140-� q i * as compyyiirrrryp! with the Florida Buildtn Coda 9 -.—.•" = ; . WALL _NOA No 20-0730.06. - HEIGHT Fxpirationnate05101/2022 w.c`•' �A7SOF 4-f � i t By RA Miami -Dade Product 314" Minimum Edge Distance Nails at 16" O.C. (typ.) SECTII B--B PRODUCT -DESCRIPTION A HardiePlank@, Cemplank®, and �518' thick /5 pry APA Prevail® Plank Lap Sing materials rated plywood are nonasbestos fiber -cement fastened products tested in accordance with ••`�•sheathing to metal studs as ASTM C1186 Grade 11, Type A and described in Note 1 meeting the requirements of the Florida Building Code - Water -resistive barrier per Florida PLANK DIMENSIONS Building Code Width Length Thickness Section 14042 <_ 9-1/2' 12' 5/16" .-.20ga. 3-/8" X 1-518" DESIGN ME$SURE RATING lit MetalGstud Installation Design Pressure HardiePlank, Metal Studs -92 psf 'Cemplank, Prevail Lap Siding Impact Resistant -)N•. 1-1/4" tau X 5/16^ P Planks installed over 5/8" thick / 5 1Y thick starter strip APA rated plywood sheathing HARDIEPLANK. CEMPLANK PREVAIL LAP SIDING INSTALLATION DETtj_t.LS • All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation Sheathing fastener, as recommendations, and the applicable sections of the Florida Building Code_ described in Note 1 Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • [Note 11518" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at Woc at panel Siding fastener, as edges and all intermediate supports using a No.8-18, 0.315" head diameter 1-1W long bugle head screw described in Note 2 ' Planks shall be applied horizontally commencing from the bottom course of the wall wilh 1-1/4" wide taps at the top of the plank such that the exposure area of each plank is :5 8-1/4" vertically. • [Note 21 The siding fastener shall be a minimum No_ 8-18, 0.315' head diameter X 2-1/4' tong` bugle head HardiePlank, screw over metal studs for screw shall have at feast 3 full threads penetrating metal framing); The siding is fastened 5 8-1W O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/$" — Cemplank, thick / 5 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 3/4" Prevail Lap Siding from the bottom edge of the overlapping plank. • Vertical Joints shall be placed over studs. Water -resistive The planks shall be installed over 518" thick / 5 ply APA rated plywood sheathing supported by a minimum barrier per Florida 20ga, Nominal 3-5/8" X 1-51W Metal C-studs spaced a maximum of 16' O.C. _ Fasteners shall have a minimum edge distance of 3/8". 518" thick / 5 ply APA rated 4d plywood sheathing fastened to metal studs as described in Note 1 209a, 3-518" X 1-5/8" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. PJ 6.00in. +- i +-16 in. OC---o- 6.00in. I 6.001n.00 f PRODUCT REVISED as complying with the Florida Building Cade r 200730.06 ._-. —_....----.---- _......_noAHo. —......_._..-..----___..... ........ Expiration Date 05/02022 Cladding Framing / �r By MlamiDade Product Control \�..` • `� ` !i? :'{ '�/� i 58.25in. t FRAMING • NOMINAL 20 GAUGE 3-518" X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 51T LONG RIBBED BUGLE HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 5/8" THICK 15 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT G" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18, 0.315" HEAD DIAMETER X 1-1/4' LONG BUGLE HEAD SCREW CLADDING • PLANKS OVERLAP 1-1/4" • THE EXPOSURE IS 5 8-1/4" • THE PLANKS ARE FASTENED WITH NO. 8-18, 0.315" HEAD DIAMETER X 2-1/4" LONG CORROSION - RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACED 3/4" UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Sheathing OF �,lt��,'.c�ORIOP.•�0����• i FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRA�ITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) ; r HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Buildind Products, Inc. 10901 Elm Avenue pig Fontana, CA 92337 Phone: 909-356-6300 SIZE FSc1A No DM NO RE' Fax 909-427-0634 A PNL-PLK-SOFF 2 Creator: E. Gonzales sca1F t^ = 1'-0" Date: 9129/2020 sHl 8 OF 12 f-- — --WALL LENGTH---- — - Stud Spacing at 16" O.C. Bf-- PRODUCT REVISED as complying with the Florida Building Code NoA-No. 20-0730.06 f WALL IEIGHT�-, Expiration Date0510=022 - , BY ? Miami -Dade Product control -.-_.L.._ .. . Nails at 4" O.C. (typ.) 318" Minimum Edge Distance DETAIL A Soffit fastener, as I i ! described in Note 1 ----.�__._...—...__-- HardieSoffit, Cemsoifit Minimum 2" X 4" S-P-F Wood Studs } The wall and soffit frames are to be -- - designed by the Architect or Engineer of Record in compliance with the Florida Building Code. SEE DETAIL A 2' X 4" S-P-F (/ Wood Studs L` HardieSoffrt, tv / Cemsoffit i ;rn SECTION B-B PRODUCT DESCRIPTION HardieSoffitO & CemsoffitO materials are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A and meeting the requirements of the Florida Building Code. SOFFIT DIMENSIONS Width Length Thickness 4' 8' 1W DESIGN PRESSURE RATING Installation Design Pressure Wood Studs -70 psf 'lll//. HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS • AR installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. • Wood studs where HardieSoffd, Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" O.C. • [Note 11 The soffit fastener shall be a 2' long, 0.223' head diameter, 0.092" shank -diameter, corrosion resistant siding nail; the fasteners shall be spaced at 4" O.C. at panel edges and intermediate studs; the fasteners shall be driven into wood studs located at 16" O.C. • Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from corners- Creator: E_ Gonzales HARDIESOFFfT, CEMSOFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 No DING NO I PNL-PLK-SOFF tr"=t'-0" I Date:9/29/2020 9OF12 REV 4.00in:-r( �4- v——16.00in.--- ►j Cladding f • / Framing LPRODUCT REVISED Florida as comp) with tho Buildln Code HOA-Um 2"730.06 .,,. _ Expiration Date USIO112022230. 51 662 • M--,I-Dade Product Control — >j �'f: . • -� _ 1 FRAMING NOMINAL 2"X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3-1016d COMMON NAILS (2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLADDING. THE SOFFIT IS FASTENED WITH 2" LONG, 0.223" HEAD HARDIESOFFIT, CEMSOFFIT PANEL DIAMETER, 0.092" SHANK DIAMETER, CORROSION DETAILS WOOD STUD CONSTRUCTION RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL EDGES AND INTERMEDIATE STUDS James Hardie Building Products, Inc. VINSTALLATION 10901 Elm Avenue ° a•Fontana, CA 92337 Phone: 909 356 6300 M NO Dl0.G NOFax 909-427-0634 PNL-PLK-SOFF 2 Creator. E. Gonzales Isciurz i = 1'-9, I Date: 9MI2020 Sir 10 OF 12 WALL LENGTH+ —.— -----«I Stud Spacing at 16" O.C. ------------- :i •s 1 • PRODUCT REVISED as camobme,•nh �h"Flofda saeina coe• 20-0730.06 WALL ` • E,ptr2NooDam0510112022 4 1EIGHTi " Cmtrol j Nails at 6" O.C. (typ.) 31W Minimum Edge Distance DETAIL A J \, Soffit fastener, as f` described in Note 1 r ! h HardieSoffit, Cemsoffit j 20ga, 3-518" X 1-518" Metal C-stud LThe wall and soffit frames are to be designed by the Architect or Ertgm of Record in compliance with the Florida Building Code. SEE PRODUCT DESCRIPTION DETAIL A HardieSoMM & CemsoffitO materials are nonasbestos fiber -cement products - - tested in accordance with ASTM C1186 i Grade II, Type A and meeting the 1 requirements of the Florida Building Code. toga, 3-58" X 1-5/6 SOFFIT DIMENSIONS i,MetalC-stud Width Length Thickness 4• a. /" Hard�e5offd Cemsoifd DESIGN PRESSURE RATING Installation E n Pressure Meta! StiiV\\%s �e� SECTION__&B Nn 81662 STATE OF .�CQRtO?- �i�!l13i1111A HARDIESOFFIT. CEMSOFFIT PANEL INSTALLATION DETAILS • All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's Installation recommendations, and the applicable sections of the Florida Building Code. • Metal studs where HardieSoffht, Cemsoffit will be Installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N_OA • The soffit shall be installed over mim urrn 20ga, Nominal 3-5V X 1-5V Metal C-studs spaced a marmnum of 16" O.C. • [Note 1] The soffit fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-11W long' ribbed bugle head screw (•or screw shall have at least 3 full threads penetrating metal framing) -,the fastener: shall be spaced at 6" O.C. at panel edges and intermediate studs; the fasteners shall be driven into metal studs located at 16" O.C. • Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from comers. HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue a Fontana, CA 92337 eer Phone:909-356-6300 FscuNo m"+cco REV Fax 909-427-0634 s&mA I PNL-PLK-SOFF 2 Creator: E. Gonzales SCAtE 112• = l -(r Date: MR2020 j sxeEr 11 OF 12 6.00in.-► LO— r 16.00in. ' . Cladding . / Framing �l 6.00in. I PRODUCT REVISED compMtng mth the Florida H.Iding coda NoA-No. 20-0730.06 • E piratlon oatc05107/2022 BY .-0 pa..controt • . • . . :E No $16tz2 ''/i ,`t�-'ant- \'• 1 FRAMING • NOMINAL 20 GAUGE 3-518• X 1-518" STEEL STUDS 16" D.C. FASTENED WITH 51T WAFER HEAD SCREWS (2 PER TOP FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLADDING HARDIESOFFIT, CEMSOFFIT PANEL THE SOFFIT IS FASTENED -WITH NO. 8-18, 0.315" HEAD INSTALLATION DETAILS METAL STUD CONSTRUCTION DIAMETER X 1-1/4 " LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 lip FULL THREADS PENETRATING THE METAL FRAMING), PLACE James Hardie Building Products, Inc. SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE 10901 Elm Avenue STUDS Fontana, CA 92337 Phone:909-356-6300 size Fscntno DWG NO ne Fax 909427-0634 A PNL-PLK-SOFF 9 Creator: E. Gonzales Scale 1" = 1'-0" Date: 9/29/2020 sNEEer 12 OF 12 y { / �iaamng ` ,Framing 6.00in. Sheathing i / 6.00in. l PRODUCT REVISED the Florida Bs Complying with Bolding Code NOA-no. 204)730.06 _ Fxpimtion Date 05/01/2022 rM)rami-Dade Product Control FRAMING �// `}f�irr:`�..�ti•• • NOMINAL 20 GAUGE 3-5W X 1-5/8" STEEL STUDS 16" O.C. FASTENED WITH 518" WAFER HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 51W THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL, CEMPANEL, PREVAIL PANEL NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE INSTALLATION DETAILS METAL STUD CONSTRUCTION HEAD SCREW CLADDING THE PANEL IS FASTENED WITH NO. 8-18,0.315" HEAD James Hardie Building Products, Inc. DIAMETER X 1-5/8 " LONG CORROSION RESISTANT 10901 Elm Avenue RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE ATp;w Fontana, CA 92337 LEAST 3 FULL THREADS PENETRATING THE METAL Phone: 909-356.6300 SIZE FSCM NO - OM NO REV FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES Fax 909-427-0634 A PNL-PLK-SOFF 2 AND INTERMEDIATE STUDS Creator E. Gonzales SCALE t- = V-0" Date: W912020 S.." 4 OF 12 RECEIVED SEP 3 ® 2021 st. -ucie eunty @W W. MR -- - Stud Spacing at 16" O.C. WALL LENGTH ------•----- } SEE B� DETAIL A ..... — � 578" thick 15 ty AP ratedplywP sheathing fastened } � : � �` � ��.�•.' i. � t � to metal studs as .� - — —PRODUCT REVISED • : as complyrnit with the Florida ..\-,� : I "' ? �tt described in Note 1 E Water -resistive War -- -- �= * �— Q ��oodd^ ' Sending o 1 . _ WALL i NOA No. 20-0730.06 = - - :-- ' am Florida HEIGHT< Enpiration Date0510112022 tag c t 1F •„% (u ' Building Code ;• _._. „,. Miami-0ade Product Control .— c �� _� —.. ____—. \ n ;4 s Rt ... \\ _ — { f. £ ,.. fir'• \\ I k Section 14042 �20ga. 3-518" X 1-516" f — - - r - _ — -- Metal C-stud HardiePlank, � ..—:_...-::.....r................. .:.............._-....-_.... --..---- �_......... ..._..... ...._..... ....i _. ------ --- --- — A Prevail 'Cemplan P Lap Siding A B F-- SECTION: 314" Minimum Edge Distance Nails at 16" O.C. (typ.) B_B 1-1/4" tall X 5116" -- thick starter strip DETA&A i 1 ' A 'E t A ` 4 2 T Sheathing fastener, as described in Note 1 5/8" thick / 5 ply APA rated plywood sheathing fastened to by the Architect or Engineer of Record in compliance with the Florida Budding Code. PRODUCT DESCRIPTION HardiePlank®, Cemplank®, and Prevail® Plank Lap Siding materials { are nonasbestos fiber -cement products tested in accordance with ASTM C1186 Grade II, Type A and meeting the requirements of the Florida Building Code- j PLANK DIMENSIONS Wri th Length Thickness 5 9-12" 12' 5116, Installation Design Pressure Metal Studs -92 psf Impact Resistant - Planks installed over 518" thick / 5 ply APA rated plywood sheathing HARDIEPLANK CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS • All installation shall be done in conformance with this Notice of Acceptance, the manufacturers installation recommendations, and the applicable sections of the Florida Building Code_ • Metal studs where HardiePlank, Gemplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • [Note 1] 518' thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel edges and all intermediate supports using a No.8-18, 0.315' head diameter x 1-1/4' long bugle head screw • Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4' wide laps at the top of the plank such that the exposure area of each plank is :5 8-1/4' vertically. • [Note 2] The siding fastener shall be a minimum No. 8-18, 0.315' head diameter X 2-114" long' bugle head screw over metal studs ('or screw shall have at least 3 full threads penetrating metal framing); The siding is fastened:5 8-1/4" O.G. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 51W thick 15 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately WC from the bottom edge of the overlapping plank. • Vertical joints shall be placed over studs. • The planks shall be installed over 5B" thick 15 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3f18" X 1-5/8' Metal G-studs spaced a maximum of 16" O.C. • Fasteners shall have a minimum edge distance of 3/8'. ...... .. . . .. . . .. .. .. .... . . . .. . ..... . . 6-00in. —16 in. OC------: 6.00in. 6.001P'.00 0.75in PRODUCT REVISED as complying with the Florida Building Code ----------- NDA-No. 20-0730.06 ------------------------- --- ------- - Expiration Date 05101/2022 By N M12MI-02de Product Con1m] ........... . FRAMING • NOMINAL 20 GAUGE 3-50 X 1-518"STEEL STUDS 16" O.C. FASTENED WITH 518" LONG RIBBED BUGLE HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) • THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING • NOMINAL 518"THICK 15 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6"OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO-8-118.0.315"HEAD DIAMETER X 1-1/4' LONG BUGLE HEAD SCREW CLADDING • PLANKS OVERLAP 1-1/4" • THE EXPOSURE IS 8-1/4" • THE PLANKS ARE FASTENED WITH NO. 8-18.0.315- HEAD DIAMETER X 2-114"LONG CORROSION - RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACED 3/4- UP FROM THE B0770M EDGE OF THE PLANK AT EACH STUD LOCATION Cladding Framing Sheathing No. F 1662 'N FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909-356-6300 s s Fscm No Mr. NO Fax 909-427 4 3 A PNL-PLK-SOFF Creator: E. Go�n�zalessc4AaLEE Date: 9M(207n ISHEU 8 OF 12 2