HomeMy WebLinkAboutLetter; Siding Products8385 White aak Ave.
C'AE Rancho Cucamonga, CA 91730
RECEIVED Phone: 626.409.8650
SEP 3 0 2021
St. Lucie County
Permitting Project No.: 2001-14.3
Date: December 14, 2020
Rathisha Sabaratnam, Sr. R&D Technical Services Specialist
James' Hardie Building Products, Inc.
10901 Elm Ave.
Fontana, CA 92337
Subject: NOA 20-0730.06 for Compliance with 2020 Florida Building Code (7th Edition)
Dear Rathisha,
At your request in reference to the Miami Dade Checklist requirements, based on my review of applicable sections
of the 2020 Florida Building Code and the submitted test reports, it is my professionalopinion that the siding products
listed in the attached NOA meet the requirements of the 2020 Florida Building Code.
At your request, based on my review of applicable sections of the 2020 Florida Building Code and the submitted test
reports for the subject products listed in the above referenced NOA, it is my professional opinion that. the siding
products listed in the NOA meet the requirements of the 2020 Florida Building Code. Attached are the updated
stamped product installation drawings.
The following are referenced standards in the 2020 FBC:
(1) Wood: AWC NDS-2018 & SDPWS-2015
(2) Structural Design: A$CE 7-16
(3) Concrete: ACI 318-14
(4) Masonry: TMS 402-2016
(5) Structural Steel: AISC 360-16 and 2017 AISC Steel Construction Manual
(6) Cold -formed Steel: AISI 100.46
(7) Aluminum: AA ADM 1-2015
In addition, I make the following Statement of Independence:
(a) I, V. Andrew Tan, do not have nor intend to acquire or will acquire any financial interest in any company
manufacturing or distributing products for which evaluations are issued.
(b) CAE is not owned, operated or controlled by any company manufacturing or distributing products we.evaluate
or inspect. '
(c) CAE does not have, nor will it acquire financial interest in any company manufacturing or distributing products
for which reports are being issued.
(d) CAE does not have, or will it acquire a financial interest in any other entity involved in the approval process
of the product. -
Please feel free to contact me %��ti�s/thank you again for your business.
Efp
E Al
Respectfully submitted, zz. F
CAE, Inc. = No. 81662 1',
a 1
i STAtTEOF ' Aj
�TOfVAL
V. AndreWTan;-F'.E., exp. 2/28/210f 111 I tt 0
Principal Engineer
Attachments. (1) NOA 20-0730.06
Fastener Spacing per Florida
Building Code Section 2322-3
...........
Cladding
Framing
---------- -------------------------------
Fastener Spacing per Florida Sheathing
Building Code Section 2322.3
0.75in
. ... ... ........ ....... .
PRODUCT REVISED
as i;amplyl.9 with the Florida Ix
Building Code
------- 20-0730.06 ----------------- --
Eitpl—ficm Date OSIO112022
BY
Miami -Dade Product Control
------- -------- ----
81§62
58.25in.
ASTAL E.,-n;:
%
FRAF At NG
• NOMINAL 2"X 4S-P-F WOOD STUDS 16"O.C. FASTENED
WITH 3-10'16d COMMON NAILS (2 PER TOP AND
BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 518!'THICK / 5 PLY APA RATED PLYWOOD
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
BUILDING CODE SECTION 2322.3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION
CLADDING
. PLANKS OVERLAP 1-1/4' James Hardie Building Products, Inc.
. THE EXPOSURE IS s8-1/4" 10901 Elm Avenue
. THE PLANKS ARE FACE NAILED WITH 2-1/2" LONG, 0.223'
HEAD DIAMETER, 0.092- SHANK DIAMETER, CORROSION-�- MR- Fontana, CA 92337
RESISTANT SIDING NAILS, PLACED 314- UP FROM THE Phone: 909-356-6300 [ZE FSCM NO DVVG NO REV
BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Fax 909-427-0634 sA PNL-PLK-SOFF 2
Creator. E. Gonzales I.. I- = 1--0- Date: 9129=20 ISHEET 6 OF 12
16 in. OC
i� Stud Spacing at i6" O-C. WALL
SEE
—PRODUCT REVISED
140-� q i *
as compyyiirrrryp! with the Florida
Buildtn Coda
9
-.—.•"
=
; .
WALL _NOA No 20-0730.06.
-
HEIGHT Fxpirationnate05101/2022
w.c`•' �A7SOF 4-f
� i
t
By
RA
Miami -Dade Product
314" Minimum Edge Distance Nails at 16" O.C. (typ.)
SECTII
B--B
PRODUCT -DESCRIPTION
A
HardiePlank@, Cemplank®, and
�518' thick /5 pry APA
Prevail® Plank Lap Sing materials
rated plywood
are nonasbestos fiber -cement
fastened
products tested in accordance with
••`�•sheathing
to metal studs as
ASTM C1186 Grade 11, Type A and
described in Note 1
meeting the requirements of the
Florida Building Code -
Water -resistive
barrier per Florida
PLANK DIMENSIONS
Building Code
Width Length Thickness
Section 14042
<_ 9-1/2' 12' 5/16"
.-.20ga. 3-/8" X 1-518"
DESIGN ME$SURE RATING
lit MetalGstud
Installation Design Pressure
HardiePlank,
Metal Studs -92 psf
'Cemplank, Prevail
Lap Siding
Impact Resistant -)N•.
1-1/4" tau X 5/16^
P Planks installed over 5/8" thick / 5 1Y
thick starter strip
APA rated plywood sheathing
HARDIEPLANK. CEMPLANK PREVAIL LAP SIDING INSTALLATION DETtj_t.LS
•
All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation
Sheathing fastener, as
recommendations, and the applicable sections of the Florida Building Code_
described in Note 1
Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
•
[Note 11518" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at Woc at panel
Siding fastener, as
edges and all intermediate supports using a No.8-18, 0.315" head diameter 1-1W long bugle head screw
described in Note 2 '
Planks shall be applied horizontally commencing from the bottom course of the wall wilh 1-1/4" wide taps at
the top of the plank such that the exposure area of each plank is :5 8-1/4" vertically.
•
[Note 21 The siding fastener shall be a minimum No_ 8-18, 0.315' head diameter X 2-1/4' tong` bugle head
HardiePlank,
screw over metal studs for screw shall have at feast 3 full threads penetrating metal framing); The siding is
fastened 5 8-1W O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/$"
— Cemplank,
thick / 5 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 3/4"
Prevail Lap Siding
from the bottom edge of the overlapping plank.
•
Vertical Joints shall be placed over studs.
Water -resistive
The planks shall be installed over 518" thick / 5 ply APA rated plywood sheathing supported by a minimum
barrier per Florida
20ga, Nominal 3-5/8" X 1-51W Metal C-studs spaced a maximum of 16' O.C.
_
Fasteners shall have a minimum edge distance of 3/8".
518" thick / 5 ply APA rated 4d
plywood sheathing fastened to
metal studs as described in
Note 1
209a, 3-518" X 1-5/8" Metal C-stud
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
PJ 6.00in. +-
i +-16 in. OC---o-
6.00in.
I
6.001n.00 f
PRODUCT REVISED
as complying with the Florida
Building Cade r
200730.06 ._-. —_....----.---- _......_noAHo. —......_._..-..----___..... ........
Expiration Date 05/02022
Cladding
Framing
/ �r
By
MlamiDade Product Control \�..` • `� ` !i? :'{ '�/�
i
58.25in.
t
FRAMING
• NOMINAL 20 GAUGE 3-518" X 1-5/8" STEEL STUDS 16"
O.C. FASTENED WITH 51T LONG RIBBED BUGLE HEAD
SCREWS (2 PER TOP AND BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 5/8" THICK 15 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT G" OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
NO.8-18, 0.315" HEAD DIAMETER X 1-1/4' LONG BUGLE
HEAD SCREW
CLADDING
• PLANKS OVERLAP 1-1/4"
• THE EXPOSURE IS 5 8-1/4"
• THE PLANKS ARE FASTENED WITH NO. 8-18, 0.315"
HEAD DIAMETER X 2-1/4" LONG CORROSION -
RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW
SHALL HAVE AT LEAST 3 FULL THREADS
PENETRATING THE METAL FRAMING), PLACED 3/4" UP
FROM THE BOTTOM EDGE OF THE PLANK AT EACH
STUD LOCATION
Sheathing
OF
�,lt��,'.c�ORIOP.•�0����• i
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRA�ITY LOAD ARE
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) ;
r
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Buildind Products, Inc.
10901 Elm Avenue
pig Fontana, CA 92337
Phone: 909-356-6300 SIZE FSc1A No DM NO RE'
Fax 909-427-0634 A PNL-PLK-SOFF 2
Creator: E. Gonzales sca1F t^ = 1'-0" Date: 9129/2020 sHl 8 OF 12
f--
— --WALL LENGTH---- — -
Stud Spacing at 16" O.C.
Bf--
PRODUCT REVISED
as complying with the Florida
Building Code
NoA-No. 20-0730.06 f
WALL
IEIGHT�-,
Expiration Date0510=022
- ,
BY
?
Miami -Dade Product control
-.-_.L.._ .. .
Nails at 4" O.C. (typ.)
318" Minimum Edge Distance
DETAIL A
Soffit fastener, as
I i ! described in Note 1
----.�__._...—...__-- HardieSoffit, Cemsoifit
Minimum 2" X 4" S-P-F Wood Studs
} The wall and soffit frames are to be
-- - designed by the Architect or
Engineer of Record in compliance
with the Florida Building Code.
SEE
DETAIL A
2' X 4" S-P-F
(/ Wood Studs
L`
HardieSoffrt,
tv / Cemsoffit
i
;rn
SECTION B-B
PRODUCT DESCRIPTION
HardieSoffitO & CemsoffitO materials are
nonasbestos fiber -cement products tested in
accordance with ASTM C1186 Grade II, Type A
and meeting the requirements of the Florida
Building Code.
SOFFIT DIMENSIONS
Width Length Thickness
4' 8' 1W
DESIGN PRESSURE RATING
Installation Design Pressure
Wood Studs -70 psf
'lll//.
HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION DETAILS
• AR installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
• Wood studs where HardieSoffd, Cemsoffit will be installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N.O.A.
• The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" O.C.
• [Note 11 The soffit fastener shall be a 2' long, 0.223' head diameter, 0.092" shank -diameter,
corrosion resistant siding nail; the fasteners shall be spaced at 4" O.C. at panel edges and
intermediate studs; the fasteners shall be driven into wood studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from corners-
Creator: E_ Gonzales
HARDIESOFFfT, CEMSOFFIT PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
No DING NO
I PNL-PLK-SOFF
tr"=t'-0" I Date:9/29/2020
9OF12
REV
4.00in:-r( �4- v——16.00in.--- ►j
Cladding
f
•
/
Framing
LPRODUCT
REVISED
Florida
as comp) with tho
Buildln Code
HOA-Um 2"730.06
.,,. _
Expiration Date USIO112022230.
51 662
• M--,I-Dade Product Control
— >j �'f: . • -� _
1
FRAMING
NOMINAL 2"X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-1016d COMMON NAILS (2 PER TOP AND BOTTOM
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
CONNECTION)
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY
THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE
WITH THE FLORIDA BUILDING CODE
CLADDING.
THE SOFFIT IS FASTENED WITH 2" LONG, 0.223" HEAD
HARDIESOFFIT, CEMSOFFIT PANEL
DIAMETER, 0.092" SHANK DIAMETER, CORROSION
DETAILS WOOD STUD CONSTRUCTION
RESISTANT SIDING NAILS, PLACE NAILS 4" O.C. AT PANEL
EDGES AND INTERMEDIATE STUDS
James Hardie Building Products, Inc.
VINSTALLATION
10901 Elm Avenue
° a•Fontana, CA 92337
Phone: 909 356 6300
M NO
Dl0.G NOFax
909-427-0634
PNL-PLK-SOFF
2
Creator. E. Gonzales
Isciurz i = 1'-9, I
Date: 9MI2020
Sir 10 OF 12
WALL LENGTH+ —.— -----«I
Stud Spacing at 16" O.C.
-------------
:i •s
1 • PRODUCT REVISED
as camobme,•nh �h"Flofda
saeina coe•
20-0730.06
WALL ` • E,ptr2NooDam0510112022 4
1EIGHTi "
Cmtrol
j
Nails at 6" O.C. (typ.)
31W Minimum Edge Distance
DETAIL A
J \, Soffit fastener, as
f` described in Note 1
r
! h HardieSoffit, Cemsoffit
j 20ga, 3-518" X 1-518" Metal C-stud
LThe wall and soffit frames are to be
designed by the Architect or Ertgm
of Record in compliance with the
Florida Building Code.
SEE
PRODUCT DESCRIPTION
DETAIL A
HardieSoMM & CemsoffitO materials
are nonasbestos fiber -cement products
- -
tested in accordance with ASTM C1186
i
Grade II, Type A and meeting the
1
requirements of the Florida Building
Code.
toga, 3-58" X 1-5/6
SOFFIT DIMENSIONS
i,MetalC-stud
Width Length Thickness
4• a. /"
Hard�e5offd
Cemsoifd
DESIGN PRESSURE RATING
Installation E n Pressure
Meta! StiiV\\%s
�e�
SECTION__&B
Nn 81662
STATE OF
.�CQRtO?-
�i�!l13i1111A
HARDIESOFFIT. CEMSOFFIT PANEL INSTALLATION DETAILS
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
Installation recommendations, and the applicable sections of the Florida Building Code.
• Metal studs where HardieSoffht, Cemsoffit will be Installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N_OA
• The soffit shall be installed over mim urrn 20ga, Nominal 3-5V X 1-5V Metal C-studs spaced
a marmnum of 16" O.C.
• [Note 1] The soffit fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-11W long'
ribbed bugle head screw (•or screw shall have at least 3 full threads penetrating metal
framing) -,the fastener: shall be spaced at 6" O.C. at panel edges and intermediate studs; the
fasteners shall be driven into metal studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from
comers.
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
a Fontana, CA 92337
eer Phone:909-356-6300 FscuNo m"+cco REV
Fax 909-427-0634 s&mA I PNL-PLK-SOFF 2
Creator: E. Gonzales SCAtE 112• = l -(r Date: MR2020 j sxeEr 11 OF 12
6.00in.-► LO—
r 16.00in. '
.
Cladding
.
/ Framing
�l
6.00in.
I
PRODUCT REVISED
compMtng mth the Florida
H.Iding coda
NoA-No. 20-0730.06
•
E piratlon oatc05107/2022
BY
.-0 pa..controt
• .
• . . :E No $16tz2
''/i
,`t�-'ant- \'• 1
FRAMING
• NOMINAL 20 GAUGE 3-518• X 1-518" STEEL STUDS 16" D.C.
FASTENED WITH 51T WAFER HEAD SCREWS (2 PER TOP
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
AND BOTTOM CONNECTION)
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
CLADDING
HARDIESOFFIT, CEMSOFFIT PANEL
THE SOFFIT IS FASTENED -WITH NO. 8-18, 0.315" HEAD
INSTALLATION DETAILS METAL STUD CONSTRUCTION
DIAMETER X 1-1/4 " LONG CORROSION RESISTANT RIBBED
BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3
lip
FULL THREADS PENETRATING THE METAL FRAMING), PLACE
James Hardie Building Products, Inc.
SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE
10901 Elm Avenue
STUDS
Fontana, CA 92337
Phone:909-356-6300 size Fscntno DWG NO ne
Fax 909427-0634 A PNL-PLK-SOFF 9
Creator: E. Gonzales Scale 1" = 1'-0" Date: 9/29/2020 sNEEer 12 OF 12
y {
/ �iaamng
`
,Framing
6.00in. Sheathing i
/
6.00in.
l
PRODUCT REVISED
the Florida
Bs Complying with
Bolding Code
NOA-no. 204)730.06
_
Fxpimtion Date 05/01/2022
rM)rami-Dade
Product Control
FRAMING
�// `}f�irr:`�..�ti••
• NOMINAL 20 GAUGE 3-5W X 1-5/8" STEEL STUDS 16" O.C.
FASTENED WITH 518" WAFER HEAD SCREWS (2 PER TOP
AND BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 51W THICK / 5 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE
INSTALLATION DETAILS METAL STUD CONSTRUCTION
HEAD SCREW
CLADDING
THE PANEL IS FASTENED WITH NO. 8-18,0.315" HEAD
James Hardie Building Products, Inc.
DIAMETER X 1-5/8 " LONG CORROSION RESISTANT
10901 Elm Avenue
RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE ATp;w
Fontana, CA 92337
LEAST 3 FULL THREADS PENETRATING THE METAL
Phone: 909-356.6300
SIZE
FSCM NO -
OM NO
REV
FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES
Fax 909-427-0634
A
PNL-PLK-SOFF
2
AND INTERMEDIATE STUDS
Creator E. Gonzales
SCALE t- = V-0"
Date: W912020
S.." 4 OF 12
RECEIVED
SEP 3 ® 2021
st. -ucie eunty
@W W. MR
-- - Stud Spacing at 16" O.C. WALL LENGTH ------•----- }
SEE
B�
DETAIL A
..... —
�
578" thick 15 ty AP
ratedplywP
sheathing fastened
} � : � �`
� ��.�•.' i.
� t
� to metal studs as
.�
- — —PRODUCT REVISED
• : as complyrnit with the Florida
..\-,�
: I
"'
?
�tt described in Note 1
E
Water -resistive
War
-- -- �= * �—
Q
��oodd^
' Sending o
1 . _
WALL i NOA No. 20-0730.06
=
- - :-- '
am Florida
HEIGHT< Enpiration Date0510112022
tag c t 1F •„% (u
'
Building Code
;•
_._. „,.
Miami-0ade Product Control .—
c �� _�
—.. ____—. \ n ;4 s Rt ... \\ _ — {
f. £ ,..
fir'• \\
I
k Section 14042
�20ga. 3-518" X 1-516"
f
— - - r
- _ — --
Metal C-stud
HardiePlank,
� ..—:_...-::.....r................. .:.............._-....-_....
--..----
�_......... ..._..... ...._..... ....i _. ------
--- ---
— A Prevail
'Cemplan P
Lap Siding
A
B F--
SECTION:
314" Minimum Edge Distance
Nails at 16" O.C. (typ.)
B_B 1-1/4" tall X 5116"
--
thick starter strip
DETA&A
i
1 '
A
'E t
A
` 4
2
T
Sheathing fastener, as
described in Note 1
5/8" thick / 5 ply APA rated
plywood sheathing fastened to
by the Architect or Engineer of Record in
compliance with the Florida Budding Code.
PRODUCT DESCRIPTION
HardiePlank®, Cemplank®, and
Prevail® Plank Lap Siding materials {
are nonasbestos fiber -cement
products tested in accordance with
ASTM C1186 Grade II, Type A and
meeting the requirements of the
Florida Building Code- j
PLANK DIMENSIONS
Wri th Length Thickness
5 9-12" 12' 5116,
Installation Design Pressure
Metal Studs -92 psf
Impact Resistant -
Planks installed over 518" thick / 5 ply
APA rated plywood sheathing
HARDIEPLANK CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturers installation
recommendations, and the applicable sections of the Florida Building Code_
• Metal studs where HardiePlank, Gemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
• [Note 1] 518' thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel
edges and all intermediate supports using a No.8-18, 0.315' head diameter x 1-1/4' long bugle head screw
• Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4' wide laps at
the top of the plank such that the exposure area of each plank is :5 8-1/4' vertically.
• [Note 2] The siding fastener shall be a minimum No. 8-18, 0.315' head diameter X 2-114" long' bugle head
screw over metal studs ('or screw shall have at least 3 full threads penetrating metal framing); The siding is
fastened:5 8-1/4" O.G. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 51W
thick 15 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately WC
from the bottom edge of the overlapping plank.
• Vertical joints shall be placed over studs.
• The planks shall be installed over 5B" thick 15 ply APA rated plywood sheathing supported by a minimum
20ga, Nominal 3f18" X 1-5/8' Metal G-studs spaced a maximum of 16" O.C.
• Fasteners shall have a minimum edge distance of 3/8'.
...... .. . . .. . . .. .. .. .... . . . .. . ..... . .
6-00in.
—16 in. OC------:
6.00in.
6.001P'.00
0.75in
PRODUCT REVISED
as complying with the Florida
Building Code
----------- NDA-No. 20-0730.06 ------------------------- --- ------- -
Expiration Date 05101/2022
By N
M12MI-02de Product Con1m]
........... .
FRAMING
• NOMINAL 20 GAUGE 3-50 X 1-518"STEEL STUDS 16"
O.C. FASTENED WITH 518" LONG RIBBED BUGLE HEAD
SCREWS (2 PER TOP AND BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 518"THICK 15 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6"OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
NO-8-118.0.315"HEAD DIAMETER X 1-1/4' LONG BUGLE
HEAD SCREW
CLADDING
• PLANKS OVERLAP 1-1/4"
• THE EXPOSURE IS 8-1/4"
• THE PLANKS ARE FASTENED WITH NO. 8-18.0.315-
HEAD DIAMETER X 2-114"LONG CORROSION -
RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW
SHALL HAVE AT LEAST 3 FULL THREADS
PENETRATING THE METAL FRAMING), PLACED 3/4- UP
FROM THE B0770M EDGE OF THE PLANK AT EACH
STUD LOCATION
Cladding
Framing
Sheathing
No. F 1662
'N
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
Phone: 909-356-6300
s
s
Fscm No
Mr. NO
Fax 909-427 4 3
A
PNL-PLK-SOFF
Creator: E. Go�n�zalessc4AaLEE
Date: 9M(207n
ISHEU 8 OF 12
2