NOTICE OF ACCEPTANCE (NOA)
James Hardie Building Product, Inc.
10901 Elm Avenue
Fontana, CA 92337
SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product
Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: "Hardie", "Cem" and "Prevail' Planks and Panels Fiber Cement Siding and Soffit
APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail
Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details
Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the
manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020, bearing the Miami -Dade County
Product Control revision stamp with the -Notice of Acceptance number and expiration date by the Miami -
Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the
following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control
Approved"' is to be located on each, siding plank or panel and per FBC 1710.9.2 and 1710:9.3 on soffit
panels.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising -literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 17-0821.21 and consists of this page 1 and evidence pages E-1 and E-2, as well
as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 20-0730.06
Expiration Date: May 1, 2022
Approval Date: November 12, 2020
Page 1
James Hardie Building Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs
A. DRAWINGS "Submitted under NOA # 13-0311.07"
1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel;
Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated
04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I.Ogawa,
P.E.
B. TESTS "Submitted under NOA # 13-0311.07"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit
and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No.
100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and
sealed by Rick Curkeet, P.E.
"Submitted under NOA # 02-0729.02"
Laboratory Report Test Date Signature
2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E.
3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E.
4. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS "Submitted under NOA # 15-0122.04"
1. Statement letter of code conformance to the 5 h edition (2014) FBC issued by Ronald
I.Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I.
Ogawa, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 204730.06
Expiration Date: May 1, 2022
Approval Date: November 12, 2020
E-1
}
James Hardie Building Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation
Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013,
prepared by the manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 76' Edition (2020) of the FBC and of no
financial interest issued by Construction Applied Engineering, dated 07/22/2020,
signed and sealed by V. Andrew Tan, P.E.
"Submitted under NOA # 17-0821.21"
2. Statement letter of code conformance to the 6`h Edition (2017) FBC and of no financial
interest issued by Ronald I.Ogawa & Associates, Inc., dated 07/30/2017, signed and
sealed by Ronald I.Ogawa, P.E.
E-2
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0730.06
Expiration Date: May 1, 2022
Approval Date: November 12, 2020
-- WALL LENGTH s
Stud Spacing at 16" O.C.
I ; `' ik. lj
t1�;rn+Sc?}3 p jij� ;
PRODUCTREVISE
dnmtamjwith the Florida`�� i.' :V;•' c N
D noA-to20-0730.06 10 81^�'<<�:WALL Si' Enpraon ae5f0112022
HEIGHT'By
arzand-nade Product Control �- STP-E''F
NAL
BF=
Nails at 16" O.C. (typ)
3/8" Minimum Edge Distance
DETAIL A
Sheathing fastener, as described in
1
Panel fastener, as described in
Note 2
! f 1
iHardiePanel, Cempanel,
I j' jj j y Prevail Panel Siding
! Water -resistive barrier per
Florida Building Code Section
i ♦ ! / 1404.2
j 5/8" thick 15 ply APA rated
plywood sheathing fastened in
accordance with Florida Building
Code Section 2322.3
2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
SEE
DETAIL A
f�
SW thick! 5 ply APA rated
plywood sheathing in
accordance with Florida
p}i
Building Code Section
ii
2322.3
Water -resistive
barrier per Florida
Building Code
Section 1404.2
2" X 4" S-P-F
Wood Studs
HardieParrel,
SECTION B-8
Cempanel,
Prevail Panel
Siding
PRODUCT DESCRIPTION
HafdiePane[O, CempanelD. &
Prevai'M Panel Siding materials are
nonasbestos fiber -cement products
tested in accordance with ASTM
C1186 Grade 11, Type A and meeting
the requirements of the Florida
Building Code.
PANEL DIMENSIONS
Width Length Thickness
4- 8,9,1V 5/16"
DESIGN PRESSURE RATING
Installation Design Pressure
Wood Studs -76 psf
Impact Resistant —
Planks installed over 518" thick /5 ply
APA rated plywood sheathing
HARDIEPANEL, CEMPANEL. PREVAIL PANEL SIDING INSTALLATION SIJETAILS
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's i
installation recommendations, and the applicable sections of the Florida Building Code.
• Wood studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be l
designed by an Engineer or Architect per the Florida Building Code and the requirements of this 7
N.O.A.
• [Note 1] 518" thick / 5 ply APA rated plywood sheathing shalt be attached to the studs in
accordance with Florida Building Code Section 2322.3.
• The siding panels shall be installed over 518" thick 15 ply APA rated plywood sheathing supported
by a minimum of 2"X4" S-P-F wood studs spaced a ma)dmum of 16" O.C.
• [Note 2] The siding panel fastener shall be a 2" long, 0.223" head diameter, 0.092" shank
diameter, corrosion resistant siding nail; the fasteners shall be spaced at 6" O.C. at panel edges
and intermediate studs; the fasteners shall be driven through the 518" thick 15 ply APA rated
plywood sheathing into wood studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of 318" and a minimum clearance of 2" from
comers.
Fastener Spacing per Florida 1
Building Code Section 2322.3-
•
Fastener Spacing per Florida
Building Code Section 2322.3
..
T�71�// PRODUCT REVISED
as complying with the Florida
•`.:.. N n
\�� `
Building Code
NOA-pro. 20-0730.06
Coo St5b2 Expiration Date05/0112022
:. \
—0 y • • : F >�i• , dliami-Dade Product Control
LL�`��
Jeri^".
yll fll llli�`��
iy
�J
Cladding
! % Framing
Sheathing
r�.
FRAMING
• NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O_C. FASTENED
WITH 3-112. 16d COMMON NAILS (2 PER TOP AND
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BOTTOM CONNECTION)
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
BUILDNG CODE SECTION 2322.3
CLADDING
• THE PANEL IS FASTENED WITH 2- LONG, 0.223" HEAD
James Hardie Building Products, Inc.
DIAMETER, 0.092" SHANK DIAMETER, CORROSION
o 10901 Elm Avenue
RESISTANT SIDING NAILS, PLACE NAILS 6" O.C. AT
Fontana, CA 92337
PANEL EDGES AND INTERMEDIATE STUDS
Phone 909 356 6300
s+if
Fsc +r+o
ova no
nsv
Fax 909-427-0634
A
PNL-PLK-SOFF
2
Creator. E. Gonzales
scare 1— v-0"
Date: 9129=0
SST 2 OF 12
rf
— MALL LENGTH ---
Stud Spacing Spacing at 16'
O.C.
PRODUCT REVISED
-
complying with the Florida
B
Building Code
` ' • '
NOA No. 20-0730.06
WALL
Expiration Date05/01/2022
HEIGHT.'
� r ` 0
BY
Miami
% STATE Or (r.
-Dade Product Control
!':
•, ��� rim"".�\` ..�
f
B
318" Minimum Edge Distance Nails at 6" O.C. (typ.)
DETAIL A
A—
f�/
I
�
4
i
1
Sheathing fastener, as
described in Note 1
Panel fastener, as described in
Note 2
HardiePaneYJ Siding
t { r
Water -resistive barrier per
Florida Building Code Section
14042
5/8" thick 15 ply APA rated
plywood sheathing fastened
j to metal studs as described
in Note 1.
j 20ga, 3-5/8" X 1-5/8" Metal C-stud
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
SEE
DETAIL A
/ = •- 5/8" thick 15 ply APA rated
'Y Plywood sheathing fastened
to metal studs as described
{ in Note 1
Water -resistive
barrier per Florida
Building Code
Section 1404.2
20ga, 3-5/81X 1-518"
Metal C-stud
HardiePanel,
SECTION B-B Cempanel,
Prevail Panel
Siding
HardiePanet@, CempanelS, & Prevail@
Panel Siding materials are nonasbestos
fiber -cement products tested in
accordance with ASTM C1186 Grade 11.
Type A and meeting the requirements of;
the Florida Building Code. ,
PANEL DIMENSIONS
Width Length Thickness
4' 8,9,10' 5116"
DESIGN PRESSURE RATING
Installation Design Pressure
Metal Studs -104 psf
Impact Resistant —
Panel installed over 5/8' thick 15 ply
APA rated plywood sheathing
HARDIEPANE—LCEMPANEL. PREVAIL PANEL SIDING INSTALLATION DETAILS
• All installation shall be done in conformance with this otice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
• Metal studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be
designed by an Engineer or Architect per the Florida Building Code and the requirements of this
N.OA-
• [Note 11518" thick / 5 ply APA rated plyvvood sheathing shall be attached to meta) studs at 6"oe
at panel edges and all intermediate supports using a No.848, 0.315"tread diameter x 1-1W long
bugle head screw
• The siding panels shall be installed over SM" thick 15 ply APA rated plywood sheathing
supported by a minimum 20ga, Nominal 3-5/8" X 1-518" Metal C-studs spaced a maxdmum of 16"
O.C.
• [Note 21 The siding panel fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-518"
long' ribbed bugle head screw ('or screw shall have at least 3 full threads penetrating metal
framing); the fasteners shall be spaced at 6" O.C. at panel edges and 'intermediate studs; the
fasteners shall be driven through the 518" thick / 5 ply APA rated plywood sheathing into metal
studs located at 16" O.C.
• Fasteners shall have a min -arum edge distance of 318" and a minimum clearance of 2" from
comers.
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
pFar90� 7-0634 1 sA FSCMND I DMNO
PNL- KSOFF
Creator: E. Gonzales IscALE 112- = 7'-0" I Date: 9W/2020
3OF12
RFV
------------------
6.00in.
.. . .......
Cladding
6.00111.
Framing
6.00m.
Sheathing
6.0ffin-
PRODUCT REVISED
as Ca-P= with the Florida
Buildingld...
NOA-Ho. 2041730.06
, el
Expiration oate0510112022
/,q A
BY
%
Nrraml-Klado Product Control
FRAMING
• NOMINAL 20 GAUGE 3-5ffi'X 1-5/8"STEEL STUDS 16"O.C.
FASTENED WITH 51W WAFER HEAD SCREWS (2 PER TOP
AND BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING'
• NOMINAL 5/8"THICK 15 PLY ARA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A 111111reeM,
NO.&-18,0.316"HEAD DIAMETER X 1-1W LONG BUGLE
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
HEAD SCREW
CLADDING
• THE PANEL IS FASTENED WITH NO. 8-18,0.315" HEAD
w pl;
James Hardie Building Products, Inc.
DIAMETER X 1-518"LONG CORROSION RESISTANT
10901 Elm Avenue
RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT
Fontana, CA 92337
LEAST 3 FULL THREADS PENETRATING THE METAL
Phone: 909-356-6300
s
Fscm r4o -
owr. NO
v
-k
F2
FRAMING), PLACE SCREWS 6'0.C- AT PANEL EDGES
Fax 909-427-0634
A7
PNL-PLK-SOFF
I
AND INTERMEDIATE STUDS
Creator: E. Gonzales
semi
I- = 1'-T
Date: 9J29/2020
Is-- 4 OF 12
---------- --
LENGTH SEE PRODUCT DESCRIPTION
Stud Spacing at 16" O.C. DETAIL A HardiePlank8i, Cemplank®, &
B4---. PrevaiND Plank Lap Siding materials
thick 5 ply ApA are nonasbestios fiber-cemen . . . . . . . . . . . . . . . . . . . .. . - - - - . . . .
itti
products tested in accordance with
rated plywood
ASTM C1186 Grade 11, Type A and
' :��sheathing in
uIrements of the
accordance with
PRODUCT REVISED meeting the req
as conIplyIng viM the - .5i Florida Building Code Florida Building -Code.
Building Code
KDA-No. 20-0730.06 i Section 2322.3
WALL PANEL DIMENSIONS
HEIGHT � F-piration Dat,0510112022 Water -resistive Width Length Thickness
barrier per Florida ,-9-1 /2. 12' 5116"
BY
Mianifpodo Product control Building Code
Section 1404.2
DESIGN PRESSURE RATING
2- X 4- S-P-F Installation Design Pressure
Wood Studs Wood Studs -92 psf
- ------------ ----------
.......... - ------ ------- - .......
Lap Siding Impact Resistant -
3/4!'Minimum Edge Distance Nails at 16" O.C. (typ.) SECTION,, ' Planks installed over 518" thick f 5 ply
B-B N, 1-114* tall X 5116" APA rated plywood sheathing
thick starter strip
DETAIL A Sheathing fastener, as HARDIEPLANK. CEMPI ANK, PREVAIL LA.PqJQ1NNQ INSTALLATION DETAILS
described in Note I All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
7 J installation recommendations, and the applicable sections of the Florida Building Code.
Wood studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
q
5 [Note 1] 518" thick 15 ply APA Fated plywood sheathing shall be attached to the studs in accordance
Siding fastener, as
with Florida Building Code Section 2322.3.
described in Note 2 Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1 14'wide
laps at the top of the plank such that the exposure area of each plank is t5 8-1 K'verficafly. ti
HardiePlank [Note 21 The siding fastener shall be a 2-112" long, 0.223* head diameter, 0.092' shank diameter,
Cemplank, Prevail corrosion -resistant siding nag; The siding is fastened:s EI-1/4" O.C_ vertically and 16" O.C. horizontally,
7
AF Lap Siding fasteners are driven into wood studs through 518" thick 15 ply APA rated plywood sheathing, fasteners
are placed in the overlapping area approximately 3W from the bottom edge of the overlapping plank.
Vertical joints shall be placed over studs.
Water -resistive barrier The plankg shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a
minimum of 2"X4' S-P-F wood studs spaced a maximum of 16' D.C.
ig per Florida Budding
Fasteners shall have a minimum edge distance of 318".
Code Section 1404.2
518" thick/ 5 ply APA rated HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
plywood sheathin
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
fastened
-------- in accordance whg id.
h Florida
James Hardie Building Products, Inc.
Building Code Section 10901 Elm Avenue
2322.3 pipFontana, CA 92337
2"X 4"S-P-F Wood Studs Phone: 909-356-6300 SIZE 17,SCII NO DWG NO REV
The wall and sofft frames are to be designed
Fax 909-427-0634 A PNL-PLK-SOFF 2
by the Architect or Engineer of Record in
compliance with the Florida Building Code. Creator: E. Gonzales SCALE 1/2" = I%0" Date: 9/2912020 _SHEET 5 OF 12