Subject: Generator Interlock Kit, model EAT-PN200
Listing Number E113887; MET Project Number 103667
Safety Standards: • UL 67 - Panelboards
Dear Mr. Samson:
Congratulations on successfully completing the MET Certification process for the Generator Interlock Kit.
Genlnterlock, lnc may begin to apply the MET Mark on the previously identified products at this time in
accordance with the MET Mark Utilization Agreement or the MET Applicant Contract. The reports
covering the above stated products are forthcoming.
Thank you for the opportunity to perform this service for Genlnterlock, Inc. W e look forward to future
opportunities with your company.
,$u�;�tie�y,
MET LABORATORIES, INC.
Keith Greenway
Baltimore Safety Lab Manager
The Nation's First Nationally Recognized Testing Laboratory I�If //�
MET Laboratories, Inc. is accredited by OSHA and the Standards Council of Canada.
SAFJ TEMP-160-0 Approval Letter for US CAN and MEX 5-31-16.doc
Page 1 of 2
Step 2: Turn off main breaker and remove panel cover.
Step 3: Drill holes as marked on panel cover with supplied 3/16 drill bit and remove all burs from drilling cover.
Step 4: Insert screws from rear of cover, install bottom plate, and install top plate (slotted) install thread lock to screws and install
retaining nuts. Ensure proper movement.
Step 5: Install 2 pole Generator breaker on top right side and place Generator Warning Sticker on Generator breaker.
Step 6: Combine the zip ties to make a loop and install zip ties around top set of breakers in panel as shown in picture below. Pull on
ends to make tight around breakers. True zip ties as needed and install Warning label next to release tab on zip tie at
Step 7: Re -Install panel cover, Verify proper operation of interlock. Main breaker ON, generator breaker OFF and generator breaker
CAN NOT be turned on. Generator breaker ON, main breaker OFF and main breaker CAN NOT be turned on.
Generator on
Main on
Step 8: Place Generator start-up procedure label on panel box, Place CAUTION label on panel box and electric meter pan.
The MA1N and the GENERATOR breakers should NEVER be able to be turned on at the same time. If panel cover is removed the
Generator. breaker is NEVER to be turned on. If for any reason the interlock does not function properly, DO NOT USE and contact us
immediately at sales GenInterlock.com for support and instructions.