Loading...
HomeMy WebLinkAboutJacques Interlock kit specsl;�ti�i��i� �� o METLaboratories, ' 1 � v ■ Safety Certification -EMI -Telecom -Environmental Simulation - NEBS 914 WEST PATAPSCO AVENUE BALTIMORE, MARYLAND 21230-3432 •PHONE (410) 949-1802 •FAX (410) 354-3313 May 17, 2019 Genlnterlock.com 2227 US Highway 1 Unit 124 North Brunswick, NJ 08902 USA Subject: Generator Interlock Kit, model EAT-PN200 Listing Number E113887; MET Project Number 103667 Safety Standards: • UL 67 - Panelboards Dear Mr. Samson: Congratulations on successfully completing the MET Certification process for the Generator Interlock Kit. Genlnterlock, lnc may begin to apply the MET Mark on the previously identified products at this time in accordance with the MET Mark Utilization Agreement or the MET Applicant Contract. The reports covering the above stated products are forthcoming. Thank you for the opportunity to perform this service for Genlnterlock, Inc. W e look forward to future opportunities with your company. ,$u�;�tie�y, MET LABORATORIES, INC. Keith Greenway Baltimore Safety Lab Manager The Nation's First Nationally Recognized Testing Laboratory I�If //� MET Laboratories, Inc. is accredited by OSHA and the Standards Council of Canada. SAFJ TEMP-160-0 Approval Letter for US CAN and MEX 5-31-16.doc Page 1 of 2 Step 2: Turn off main breaker and remove panel cover. Step 3: Drill holes as marked on panel cover with supplied 3/16 drill bit and remove all burs from drilling cover. Step 4: Insert screws from rear of cover, install bottom plate, and install top plate (slotted) install thread lock to screws and install retaining nuts. Ensure proper movement. Step 5: Install 2 pole Generator breaker on top right side and place Generator Warning Sticker on Generator breaker. Step 6: Combine the zip ties to make a loop and install zip ties around top set of breakers in panel as shown in picture below. Pull on ends to make tight around breakers. True zip ties as needed and install Warning label next to release tab on zip tie at Step 7: Re -Install panel cover, Verify proper operation of interlock. Main breaker ON, generator breaker OFF and generator breaker CAN NOT be turned on. Generator breaker ON, main breaker OFF and main breaker CAN NOT be turned on. Generator on Main on Step 8: Place Generator start-up procedure label on panel box, Place CAUTION label on panel box and electric meter pan. The MA1N and the GENERATOR breakers should NEVER be able to be turned on at the same time. If panel cover is removed the Generator. breaker is NEVER to be turned on. If for any reason the interlock does not function properly, DO NOT USE and contact us immediately at sales GenInterlock.com for support and instructions. Thank You for your support, GenInterlock Team DISCLAIMER: Geninterlock.com is NOT responsible for misuse or improper installation. All electrical equipment should be installed and maintained by qualified personnel. Any consequences arising from improper use is the responsibility of the user. Genlnterlock.com Sales rr geninterlock.com 732-339-4191