Loading...
HomeMy WebLinkAboutCERTIFICATION OF COMPLIANCECERTIFICATION OF COMPLIANCE 12" x 12" SQUARE GRATE: P/N ,, t Contents: 1 Part Number: 640-472x V Description: Square Grate Size: 12" x 12" Open Area: 62.4 in' GPM @ 1.5 fps: 292 Floor Flow Rate: 356 GPM Wall Flow Rate: 280 GPM VGB Zoos Date of Manufacture: ry Date of Installation: Name of Installer:A uat c Surfaces of Treasure Signature of Installer: ` Coast This product has been tested, certified and listed to the requirements of ASME/ANS1 A .1 .8-2007, ASME/ANSI A 112.19.8a- 2008, ASME/ANSI A112.19.8b-2009 and APSP-16-2011 per §1404 ofthe Virginia Grah aker (VGB 2008) Pool and Spa Safety Act Certified by: Underwriters Laboratories, Inc., 2929 E. Imperial Highway, Suite 100, Brea, CA 92821-6729 This product is certified to comply with §1404 of the Virginia Graham Baker (VGB 2008) Pool and Spa Safety Act. A copy of the test results for the above may be found at www.waterwayplastics.com or go to: www.ul.com.This product is manufactured by Waterway Plastics, Oxnard CA 93030 Designed, ' / r l / , waterway._ Engineered 8 Menuraclured 2200 East Sturgis Road Oxnard CA 93030 • Phone 805.981.0262 - Fax 805.981.9403 in me USA. waterway@waterwayplastics.com • www.waterwayplastics.com 02020waTeNgP1ja1x5 810-0253.0320 VGB GRATE AND FRAME OWNER'S MANUAL For Model Number- 640-472x V 02" x 12` ) WARNING Read and keep these instructions for future reference. Follow all instructions in this owner's manual and on the equipment. Failure to follow instructions can cause severe injury and/or death. IMPORTANT SAFETY INSTRUCTIONS WARNING - SUCTION ENTRAPMENT HAZARD Body Suction Entrapment: A negative pressure applied to a large Suction in suction outlets and/or suction outlet oortion of the body or limbs can result in an entrapment covers which are damaged, broken, cracked missing, or unsecured can cause severe injury anal Evisceration / Disembowelment Entrapment: A negative pressure or death due to the following entrapment hazards applied directly to the intestines through an unprotected suction Hair Entrapment: Harr can become entangled in suction outlet cover Limb Entrapment: A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken cracked, missing or not securely attached can result in a mechanical bind or swellinc the limb. outlet sump or suctlon outlet cover which is damaged, broken, cracked missing, or unsecured can result in evisceration / disembowelment entrapment. Mechanical Entrapment: There is potential for jewelry, swimsuit, -iai, ler,rranom finger the or knuckle to be caught in an openino of a 'nul 0111let cower resulting ni mechanical entrapment TO REDUCE THE RISK OF ENTRAPMENT HAZARDS: Use two or more suction htting on eac r pump suction Irne. The suction fittings shall be separated by a minimum of 3 ft nf1 (91.44 (m), or if any are located closer they �LI shall be located on two different planes (i.e., one on the bottom and one on the vertical wall, or one each Of' two separate vertical wall). In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump(s) for the specific suction system. Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. The maximum system flow rate shall not exceed the flow rating of any listed (per ASME Al 12.19.8-2007) suction outlet cover installed. In the event of one suction outlet being completely blocked the remaining suction outlets serving the system shall have a flow rating capable of the full flow of the pump(s) Never use a pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. Two or more suction outlets per pump should be installed in accordance with latest APSP Standards and CPSC guidelines, and follow dll National, State, and Local codes applicable Replace the suction within 7 years from the installation date Installation of a vacuum release system, which relieves entrapping suction, is recommended USE ONLY GENUINE SUPER PRO REPLACEMENT PARTS. Screws Grat Glace rrame Head Loss Curve 12' x 12' 23 0.5 0 0 SO IW I50 200 250 3W 1S0 �W :SG ry flow Rate (GMA) Head Loss Curve W 1 �" u iW Aso 200 LSO no 1SO 40 Flow Rate 1fiPM) 02018 Waterway Plastic` 810-0213.0618 WARNING AFailure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets can result in an increased potential for suction entrapment as described on the previous page. AFailure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material, can result in an increased potential for suction entrapment as described on the previous page. ASuction outlet components have a finite life. The cover/grate should be inspected frequently and replaced at least every seven years, or if found to be damaged; broken, cracked, missing, or not securely attached. AThe 12" x 12" fitting is rated at 356 GPM for floor and 280 GPM for wall. If the fitting is missing or broken, replace with a fitting of equivalent rating or higher. Use of a lower rated suction fitting could result in entrapment of the body which could result in serious injury including drowning. ADo not use or operate pool, spa, or hot tub if this suction fitting is missing, broken or not secured per instructions. The suction fitting is intended to prevent entrapment of the body. Use of the spa hot tub with a missing, broken or improperly secured suction grate may result in serious personal injury including drowning. AWhen the pool, spa or hot tub is in operation, suction is created at this fitting. Users of the spa or hot tub must be instructed not to come in contact with this fitting in such a way as to block its orifice. If a user of the spa or hot tub blocks this fitting with his/her body, serious personal injury or drowning may occur. AIn order to remove the suction cover (for service or winterization), using a Phillips -head screw driver remove the screws. Inspect both the suction cover and suction fitting for any cracks or damages. Ait is imperative to securely attach the suction cover to the wall fittings (use only the original supplied screws or obtain original replacements). Do not over tighten the screws. Inspection of fasteners and observation for damaged/tampered with suction fittings is required. AAny and all broken or missing parts must be replaced prior to starting spa or pool pump. Never operate spa or pool without drain cover in place and properly affixed, death or serious injury can result. ADo not exceed the safe flow rate. Do not increase flow through system by increasing pump size or horsepower. ADo not allow children to sit, play or interact with main drains or suction outlet. ;02i' P Waten av Plasti" INSTRUCTIONS FOR THE USE OF FIELD BUILT SUMPS A C D min. ' 1.5 D min. GENERAL NOTES (al D = inside diameter of pipe. (b All dimensions shown are minimums. icl A broken line ) indicates suggested sump configuration FIELD BUILT SUMP la I-- Dmin. 1.5 Dmin. D min. O -- n min jD min. �. 5 D mir, — 7 The design of field fabricated sumps shall be further specified by a Registered Design Professional so as to fully address the considerations of cover/grate loadings, durability. hair, finger, and limb entrapment issues, as well as features particular to the site. LIMITED WARRANTY Waterway Plastics manufactures Its produCU and equipment In accordance with very nigh standards of workmanship. We use the best materials available and maintain the highest quality procedures practical In the industry. ror Warranty, product must be registered at time of purchase/installation at www.waterwayplastics.com. For Warranty claims or Questions, please contact point of purchase. Super*Fro, genuine replacement parts MR - Designed\ by _ngineered & Manufactured n the USA Vvz�3tIL?r--way 'J20'L0 Waterway Plastics 810.0213-SG 0320