Loading...
HomeMy WebLinkAboutStructural Performance Certification Authorization ReportDocument Title: Doc No: FRIVI B1-02 Structural Performance Rev No: 7 Page: 1 Of: 1 G�ta`t'll"tG,FaT14Fi�s iF&G� Certification Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 622 - 103.0 Issue Date: 1/16/2015 Revision Date: 2/16/2018 Expiration Date: 7/18/2021 Company Code: 622 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. I Licensee Information: I Product Information: I Eastern Architectural Systems 16341 Domestic Avenue Fort Myers FL 33912 Model: 1 "x4" Aluminum Mullion HN/T/X Operator Type: Mull Config: No Reinforcement Max Width: See Table Max Height: See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test Report No: CTLA-3010W-8A/9A Test Report Expiration: 7/18/2021 Authorized Si.gna ure: l 1:1 0:21-:050 / t Keystone Certifications, Inc. 145 Limekiln Rd. Suite 100D New Cumberland, Pennsylvania 17070 Phone: 717-932-8500 Fax: 717-932-8501 W W W. KEYSTONECERTS. COM CL.RT{P?CATIONS INC. Appendix CAR No: 622-103.0 Expiration Date:7/18/2018 Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: 1"x4" Aluminum Mullion, Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION: 1" x 4" - ONE-WAY MULLIONS SPAN TRIBUTARY WIDTH'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 2TW 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 49 200.0 200.0 200.0 200.0 2 200.0 200.0 200.0 200.0 CL 60 200.0 200.0 200.0 200.0 200.0 00.0 200.0 200.0 200.0 72 200.0 200.0 200.0 181.5 1 147.9 139.7 138.6 132.6 84 200.0 159.9 130.4 111.2 98.0 88.5 82.5 81.7 76.7 96 140.1 106.3 86.3 73.2 64.1 57.4 53.1 52.5 48.8 108 98.1 74.2 60.1 50.8 1 44.3 1 39.5 36.3 35.9 33.1 DESIGN PRESSURE LIMITS FOR MULLION: 1" x 4" - TWO-WAY MULLIONS TRIBUTARY WIDTH 'W' (IN.) [SPAN'L' (IN.) 18 4 30 36 42 48 53.125 54 60 24 200.0 200. 00.0 200.0L200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200. 00.00.0 200.0 200.0 200.0 198.5 48 200.0 200.0 200.0 200.0.0 186.1 168.1 165.4 148.8 60 200.0 200.0 200.0 198.5 170. 148.8 134.5 132.3 119.1 - 72 200.0 200.0 196.6 163.8 140.4 122. 111.0 109.2 98.3 84 200.0 154.7 123.8 103.2 88.4 77.4 6 68.8 61.9 96 138.2 103.7 82.9 69.1 j 59.2 51.8 46.8 41.5 108 97.1 72.8 58.2 48.5 1 41.6 1 36.4 32.9 32.4 Impact Ratings ASTM E1996 - Wind Zone 4, Missile Level D PA/TAS 201/203 - Large Missile and Small Missile compliant Keystone Certifications, Inc. 145 Limekiln Rd, Suite 100E New Cumberland, PA 17070 Phone: 717.932.8500 www.keystonecerts.com