HomeMy WebLinkAboutEnergy CodeA
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 44 Block 1 Waterstone 1780 BGR
Street: 5435 Lugo Street
City, State, Zip: Fort Pierce , FL , 34951
Owner:
Design Location: FL, ST LUCIE CO INTL
Builder Name: ADAMS HOMES
Permit Office:
Permit Number:
Jurisdiction: 661000
County: St. Lucie (Florida Climate Zone 2 )
I. New construction or existing
New (From Plans)
10. Wall Type41513.4 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1245.40 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0 268.00 ft2
4. Number of Bedrooms
3
c. N/A
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (1900.0 sqft.)
R= ft2
Insulation Area
6. Conditioned floor area above grade (ft2)
1780
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 1780.00 ft2
R=19.0
Conditioned floor area below grade (ft2)
0
c. N/A
120.00 ft2
R= ft2
7. Windows(177.0 sqft.) Description
Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33
113.31 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 356
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
45.94 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55
17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 2.639 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.272
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
SHGC(AVG): N/A
ft2
15. Hot water systems
9. Floor Types (1780.0 sqft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1780.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.099
Total Proposed Modified Loads: 52.37
PASS
Total Baseline Loads:
52.75
I hereby certify that the plans s ications covered
this calculation are in comp the Flori rg}
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE: e_
RbVNw of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- c:ompliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
5/6/2021 4:04 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPI IT CI IMMADV f%UCf%V1 10r 130onor
PROJECT
Title:
Lot 44 Block 1 Waterstone 17 Bedrooms: 3
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 1780
Lot #
44-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
' # of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5435 Lugo Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL , 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp Heating Design Daily Temp
Design
Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1780 15664 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ft2 ----
0.38 0 0.62
ROOF
/
V
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
#
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1990 ft2 446 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1780 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Knee Wall (Vented)
Main 19 Batt
120 ft2 0.11
Wood
2
Under Attic (Vented)
Main 30 Blown
1780 ft2 0.11
Wood
5/6/2021 4:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPI IT All IMMADV r%14=rr1e1 icT oconor
- - -
..�..,.. .
WALLS
Adjacent
Space
Cavity Width
-
Height
Sheathing Framing Solar Below
o
1 NW Exterior Concrete Block - Int Insul
Main
4.1 40 0
8 0
320.0 ft2
0
0 0.6
0
2 NE Exterior Concrete Block - Int Insul
Main
4.1 40 6
8 0
324.0 ft2
0
0 0.6
0
3 E Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ftz
0
0 0.6
0
4 SE Exterior Concrete Block - Int Insul
Main
4.1 11 10
9 6
112.4 ft'
0
0 0.6
0
5 S Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ft2
0
0 0.6
0
6 SW Exterior Concrete Block - Int Insul
Main
4.1 54 0
8 0
432.0 ft'
0
0 0.6
0
7 - Garage Frame - Wood
Main
13 33 6
8 0
268.0 ft2
0
0.23 0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 SE Insulated Main
None
.25
3
6 8
20 ft'
2 - Wood Main
None
.46
2
8
6 8
17.8 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
V
Overhang
# Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 NW 1 Metal Low-E Double
Yes
0.55 0.7 N
17.8 ft2
14 ft 4 in
0 ft 10 in
None
None
2 NW 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3 NE 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
4 E 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
5 SE 4 Vinyl Low-E Double
Yes
0.33 0.21 N
23.2 ft2
1 ft4 in
0 ft 10 in
Drapes/blinds
None
6 S 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7 SW 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 591 ft2 591 ftZ
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1827.5 100.26 188.23
.1312
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
5/6/2021 4:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020
# System Type
1 Central Unit/
INPUT SUMMARY CHECKLIST REPORT
# System Type SubT
1 Electric None
FSEC
Cert # Company Name
None None
COOLING SYSTEM
Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
Location EF Cap Use SetPnt Conservation
Garage 0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
Collector Storage
System Model # Collector Model # Area Volume FEF
ft2
DUCTS
/
---- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT QN
RLF
Heat Cool
1
Attic
6 356 ft2 Main
89 ft2
Proposed Qn
Main
--- cfm
106.8 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Venting
Jan
f X Jan
Feb
Feb
HX
Mar
Mar
Apr
Apr
May
May
Jun
Jun
rl
Jul
Jul
ri
X Au
AuSep
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
[ Jan
Feb
Mar
[X] Apr
[
May
Jun
Jul
[ Aug
Se
[
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66,
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft2
0 ft
0.3
Main
5/6/2021 4:04 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
5435 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1245.40 ftZ
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
268.00 ftZ
c. N/A
R=
ftZ
4. Number of Bedrooms
3
d. N/A
R=
ftZ
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1780.00 ftZ
6. Conditioned floor area (ftZ)
1780
b. Knee Wall (Vented)
R=19.0
120.00 ftZ
7. Windows- Description
Area
c. N/A
R=
ftZ
a. U-Factor: Dbl, U=0.33
113.31 ftZ
12. Ducts, location & insulation level
R ftZ
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 356
b. U-Factor: Dbl, U=0.33
45.94 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
C. U-Factor: Dbl, U=0.55
17.78 ftZ
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ftZ
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.639 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.272
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ftZ
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation
Area
b. Conservation features
a. Slab -On -Grade Edge Insulation
R=0.0
1780.00 ftZ
None
b. N/A
R=
ftZ
Credits (Performance method)
Pstat
c. N/A
R=
ftZ
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder SignaDate:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/6/2021 4:04 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1