REPLACE DOORS IN 1 OPENING ONLY.
NEW DOORS TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
OPENING PRODUCT DESIGN
OPENING SO. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO WIDTH. HGT FTG. ZONE POS NEG [N.O.A.#] POS. NEG.
1 74 80 41.11 4 34.4 1 -37.6 FL20867.1 55.0 1 -55.0 FRONT ENTRY-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS
NO CHANGE IN SIZE NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 114" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS
LESS THAN 30%OF STRUCTURE'S VALUE NOT A RENOVATED BUILDING. EXEMPT FROM 2020 ENERGY CONSERVATION CODE
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 14 FT 3 IN
MEAD RESiDENCE
5519 PINE TREE DRIVE DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA