HomeMy WebLinkAboutSITE PLAN 74" X 80" 1 REPLACE DOORS IN 1 OPENING ONLY. NEW DOORS TO BE IMPACT RESISTANT- HURRICANE SHUTTERS NOT REQUIRED. OPENING PRODUCT DESIGN OPENING SO. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO WIDTH. HGT FTG. ZONE POS NEG [N.O.A.#] POS. NEG. 1 74 80 41.11 4 34.4 1 -37.6 FL20867.1 55.0 1 -55.0 FRONT ENTRY-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS NO CHANGE IN SIZE NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 114" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS LESS THAN 30%OF STRUCTURE'S VALUE NOT A RENOVATED BUILDING. EXEMPT FROM 2020 ENERGY CONSERVATION CODE SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 14 FT 3 IN MEAD RESiDENCE 5519 PINE TREE DRIVE DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA