Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 48 Block 1 Waterstone 2000 BGR Builder Name: ADAMS HOMES Street: 5415 Lugo Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1941.1 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. Frame - Wood, Exterior R=13.0 288.56 ft2 R=13.0 224.40 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2104.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ft2 6. Conditioned floor area above grade (ft2) 2004 b. Knee Wall (Vented) R=19.0 100.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(199.2 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 142.83 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 400.8 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 38.54 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 4.831 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.268 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2004.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 58.31 Glass/Floor Area: 0.099 PASS Total Baseline Loads: 61.34 I hereby certify that the plans an tions covered b this in lia Review f the plans and �H$ ST9 calculation are com h d p g specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. tr rr_rrr �• =�;; �,� O. PREPARED BY: Before construction is completed t F DATE: 1715-1718-2091 V inn KPnmany this building will be inspected for �- �•< compliance with Section 553.908 ,� I hereby certify that this building, as designed, is in compliance Florida Statutes. y,S with the Florida�e ode. OWNER/AGE^�T'i - - BUILDING OFFICIAL: DATE:: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 5/6/2021 10:40 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPnRT PROJECT Title: Lot 48 Block 1 Waterstone 20 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2004 Lot # 48-1 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5415 Lugo Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2004 18837.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2004 18837.6 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0 2004 ft' ---- 0.35 0 0.65 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2241 ftz 502 ftz Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RIBS IRCC 1 Full attic Vented 300 2004 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2004 ftz 0.11 Wood 2 Knee Wall (Vented) Main 19 Blown 100 ftz 0.11 Wood 5/6/2021 10:40 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block - Int Insul Main 4.1 53 7 9 7 513.5 ftZ 0 0 0.6 0 2 S Exterior Concrete Block - Int Insul Main 4.1 20 0 9 4 186.7 ftZ 0 0 0.6 0 3 W Exterior Frame - Wood Main 13 25 2 8 11 224.4 ftZ 0 0.23 0.6 0 _ 4 W Exterior Concrete Block - Int Insul Main 4.1 39 0 9 4 364.0 ftZ 0 0 0.6 0 5 N Exterior Concrete Block - Int Insul Main 4.1 37 4 9 9 364.0 ftZ 0 0.6 0 6 - Garage Frame - Wood Main 13 30 11 9 4 288.6 ftZ 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .25 2 8 6 8 17.8 ftZ 2 S Insulated Main None .25 3 6 8 20 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 13.3 ftZ 1 ft 5 in 0 ft 9 in None None 2 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ftZ 1 ft 5 in 0 ft 9 in None None 3 S 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ftZ 1 ft 5 in 4 ft 0 in None None 4 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 1 ft 5 in 0 ft 9 in None None 5 N 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft' 11 ft 8 in 1 ft 0 in None None 6 N 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 1 ft 5 in 0 ft 9 in None None 7 N 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft' 11 ft 8 in 0 ft 9 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 754 ftZ 754 ftZ 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2197.7 120.57 226.36 .1348 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 5/6/2021 10:40 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT RIIMMARY C_I-II=rKI IRT RFPnPT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 400.8 ft Main 100.2 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Heatinf X� Jan H Feb Mar Mar HX Apr Apr Jul May Jun Jul May X Jun ri AuSeP rj Aug Se ri Oct Oct Nov Nov Dec Dec Ventin [ ] Jan Feb Mar [X] Apr [ May Jun Jul Aug Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 5/6/2021 10:40 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2 7. Windows" Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 5415 Lugo Street, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ft2 b. Frame - Wood, Adjacent R=13.0 288.56 ft2 1 c. Frame - Wood, Exterior R=13.0 224.40 ft2 4 d. N/A R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ft2 2004 b. Knee Wall (Vented) R=19.0 100.00 ft2 Area c. N/A R= ft2 142.83 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 400.8 38.54 ft2 13. Cooling systems kBtu/hr Efficiency 17.78 ft2 a. Central Unit 35.0 SEER:16.00 ft2 4.831 ft. 0.268 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: kBtu/hr Efficiency 34.6 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, ' Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/6/2021 10:40 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1