Loading...
HomeMy WebLinkAboutEnergy Code6 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 116 Block 5 Waterstone 1820 BGL Builder Name: ADAMS HOMES Street: 5326 San Benedetto Place Permit Office: City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeQ120.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1520.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 330.00 ft2 c. Frame - Wood, Adjacent R=13.0 270.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1900.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1820 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 1820.00 ft2 R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(239.3 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 168.74 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.33 20.42 ft2 SHGC: SHGC=0.31 Area Weighted Average Overhang Depth: 4.143 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.269 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (1820.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 62.15 PASS Total Baseline Loads: 63.72 I hereby certify that the plans s ications covere .... Revi of the plans and TNB S92' this calculation are in compl' c' r' ergy Code. specifications covered by this _ p. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: ns-10-91191 IA/inn Kanmany this building will be inspected for - I compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Energy Florida Statutes. ` ,S Code.0D:;vy OWNER/AGENT BUILDING OFFICIAL: DATE: e-- DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 K't requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).Y 6/30/2021 11:40 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FILE COPY FILE COPY FIORM R405-2020 IKIDI IT ¢1111A11AAOV ir-r- .....�.�. v.1 RGrVl�1 PROJECT Title: Lot 116 Block 5 Waterstone 1 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1820 Lot # 116-5 Owner Name: # Units: Total Stories: 1 Block/Subdivision: Waterstone of 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5326 San Benedetto PI Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE Design Location Design Temp TMY Site Int Design Temp Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_ BEACH 39 90 70 _MUNI 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 0.42 0 ---- 0.58 ROOF / V # Type Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles _ 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 ft2 0.11 Wood 6/30/2021 11:40 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 -VKM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS if nrnr Adjacent To WAI Tyne Space Cavity Width R value F+ In Height In nrpn 1 NE Exterior Concrete Block - Int Insul Main 4.1 49 -Et 0 10 0 490.0 ftz 2 NW Exterior Concrete Block - Int Insul Main 4.1 20 0 10 0 200.0 ftz 3 SW Exterior Concrete Block - Int Insul Main 4.1 56 0 10 0 560.0 ftz 4 SE Exterior Concrete Block - Int Insul Main 4.1 27 0 10 0 270.0 ftz 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ftz 6 NE Exterior Frame - Wood Main 13 10 10 100.0 ftz 7 SE Exterior Frame - Wood Main 13 13 10 130.0 ftz 8 SW Exterior Frame - Wood Main 13 10 10 100.0 ftz DOORS # Ornt Door Type 1 NW Insulated 2 Wood / Wall # Ornt ID Frame Panes 1 NE 1 Vinyl Low-E Double 2 NE 1 Vinyl Low-E Double 3 NW 2 Vinyl Low-E Double 4 NW 2 Vinyl Low-E Double 5 NW 2 Vinyl Low-E Double 6 NW 2 Vinyl Low-E Double 7 SW 3 Vinyl Low-E Double 8 SE 4 Vinyl Low-E Double 9 SE 4 Vinyl Low-E Double 10 SE 4 Vinyl Low-E Double # Floor Area Ceiling Are 1 396 ftz 396 ftz # Scope Method 1 Wholehouse Proposed ACH(50) SLA .000444 Space Storms U-Value Main None .25 Main None .25 WINDOWS ation shown is the entered, Proposed orientation. NFRC U-Factor SHGC Imp Area Yes 0.33 0.23 N 6.9 ftz Yes 0.33 0.23 N 4&6 ftz Yes 0.33 0.31 N 7.1 ftz Yes 0.33 0.21 N 16.2 ftz Yes 0.33 0.21 N 16.2 ftz Yes 0.33 0.31 N 13.3 ftz Yes 0.33 0.23 N 48.6 ftz 1 Yes 0.55 0.7 N 17.8 ftz 1 Sheathing Framing Solar Below -va Riiue Fraction-Absor_Grade� 0 0 0.6 0 0 0 0.6 0 0 0 0.6 0 0 0.6 0 0 0.23 0.01 0 0.23 0.6 0 0.23 0.6 0 0.23 0.6 0 Width Height Area Ft In Ft In 3 6 8 20 ftz 2 8 6 8 17.8 ftz 1 1 Overhang Depth Separatic 1ft4in 0ft10in 1ft4in 0ft10in 9ft0in 0ft6in 1ft0in 0ft10in 1ft0in 0ft10in 9ft0in 2ft0in ft4in 0ft10in ft10in Oft6in ft4in Oft10in ft10in Oft6in ACH 381 Int Shade None None None None None None None None None None Wall Insulation 1 ACH 50 7 None None None None None None None None None None 6/30/2021 11:40 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 Width Height Area Ft In Ft In 3 6 8 20 ftz 2 8 6 8 17.8 ftz 1 1 Overhang Depth Separatic 1ft4in 0ft10in 1ft4in 0ft10in 9ft0in 0ft6in 1ft0in 0ft10in 1ft0in 0ft10in 9ft0in 2ft0in ft4in 0ft10in ft10in Oft6in ft4in Oft10in ft10in Oft6in ACH 381 Int Shade None None None None None None None None None None Wall Insulation 1 ACH 50 7 None None None None None None None None None None 6/30/2021 11:40 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R4n5-gn9n IAIDI IT 01111nnnAOv tc+r ...-..�. v.l f�GrVltl HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling j Jan Feb Mar Heating X] Jan Feb Mar Venting Jan A r APr Ma rj JunX Jul X Au May Jun Jul AuSep Se ri Oct Oct Nov Nov HX Dec Dec [ ] Feb X Mar [ A r [ Ma Jun [ Jul [ Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 78 78 78 78 78 78 78 80 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 PM 68 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 PM 68 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 6/30/2021 11:40 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 .FORM R405-2020 N ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5326 San Benedetto Place , Fort Pierce, FL, 34951 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.31 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1520.00 ftZ 1 b. Frame - Wood, Exterior R=13.0 330.00 ftZ c. Frame - Wood, Adjacent R=13.0 270.00 ftZ 4 d. N/A R= ftZ No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ftZ 1820 b. Knee Wall (Vented) R=19.0 80.00 ftZ Area c. N/A R= ftZ 168.74 ftZ 12. Ducts, location & insulation level R ftZ a. Sup: Attic, Ret: Main, AH: Main 6 364 32.38 ftZ 13. Cooling systems kBtu/hr Efficiency 20.42 ftZ a. Central Unit 35.0 SEER:16.00 17.78 ftZ 4.143 ft. 0.269 Area ftZ Insulation Area R=0.0 1820.00 ftZ R= ftZ R= ftZ 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature ( -�� Date: Address of New Home: City/FL Zip: kBtu/hr Efficiency 34.6 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/30/2021 11:41 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1