HomeMy WebLinkAboutAPPROVED, Villas 5,6,7 & 8 Truss Layout3/12 SLOPE CEILING TO 10'-0"8'-0" INTERIOR BEARING8'-0" INTERIOR BEARING8'-0" INTERIOR BEARING8'-0" INTERIOR BEARING8'-0" INTERIOR BEARING8'-0" INTERIOR BEARING8'-0" INTERIOR BEARING8'-0" INTERIOR BEARING8'-0" INTERIOR BEARINGEND VERTICAL HELD BACK 6"END VERTICAL HELD BACK 6"END VERTICAL HELD BACK 6"8'-0" INTERIOR BEARING10'-0" CLG.10'-0" CLG.10'-0" CLG.10'-0" CLG.10'-0" CLG.10'-0" CLG.10'-0" CLG. 10'-0" CLG.BEARINGSUPPORTREQUIRED0LUS24360036002155490JA*0A5320MODEL09100HGUS28-4FHGUS28-22140AHGUS26-3HTU28-2155552302155ROOF4680F3SPECIALG4095ROOF TRUSSHTU26-274603235HTU26D2175A*HSYMBOL74600KHED03485JQTY4680BHGUS28-30GUPLIFTESIMPSON CONNECTORSCHEDULE263235C00CHTU28ID895BHGUS26-2CAAAAAAAAAAAAAAAAAAAAAAAAAACCA12A13A14A15A16A17A18A19A20A21A22A23A24A25A26A27A28A29A30A31A32A33A34A53A52A51A50A49A48A47A46A45A44A43A42A41A40A39A38A37A36A36A36A36A35B04B05B06B12B13B14B14B14B14B14B15B15B15B15B15B01B02B02B02B02B02B03B03B03B03B03B07B04B05B06E52E52EG5B11B08B09B10H4C1C3C1C3E4E4E4E4EE4E4H38C1C3C1C3E38AG1FW01FW02FW03FW04FW05FW06H24C1C1E24E24A01A02A03A04A05A06A07A08A09A10A11H7C1C3C5C1C3C5E7E7VE7VE7VE7VE7VE7VE7VE7VE7VE7VE7VE7E7E7E7E7E7E7P01P02P03A65A64A63A62A61A60A59A58A57A56A55A54H7C1C3C5C1C3C5E7E7E7E7E7E7E7E7E7E7E7E7E7E7E7E7E7E7E7P01P02P03P03MV04MV07MV05MV06MV09MV10MV11MV12MV01MV02MV03MV08MV13P03P03P03P03P03P03P03P03P03P05P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P03P04P03P0357' 0" 8' 0" 65' 0" 65' 0" 20' 8"6' 8" 12' 8"20' 0"4' 4" 10' 8"15' 0"20' 0"11' 8" 7' 4"21' 4"150' 4"22' 8"17' 4"13' 4"10' 0"11' 8"13' 8"10' 0"11' 4"40' 4"150' 4"7' 0"7' 0"4' 0" 9"1' 4"11' 9"8' 2"6"4' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 1' 10 1/2"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 1' 0"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 1' 10 1/2"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 11 1/4"2' 0"1' 8 3/4"4' 0" 4' 0"4' 0" 4' 0"4' 0" 4' 0"1' 3 1/4"2' 0"1' 8 3/4"6 1/2"6 1/2"1' 8 3/4"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"1' 0" 2' 0"1' 8 3/4"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"1' 0" 2' 0"1' 8 3/4"6 1/2"1' 8 3/4"20' 1"1' 0" 1' 0"1' 0"1' 0" 2' 0"2' 0"2' 0"2' 0" 2' 0" 2' 0"1' 0" 1' 0"1' 4" 2' 0" 1' 4"2' 0"2' 0"1' 3 1/4"2' 0"2' 0" 2' 0" 2' 0" 1' 0" 1' 0"2' 0" 8" 2' 0" 2' 0"11 1/4"2' 0"2' 0" 8"8" 2' 0" 2' 0"2' 0" 2' 0"2' 0" 2' 0" 2' 0"2' 0"11' 8"16' 0" 15' 0" 12' 11"12' 9"VERIFYALLDIMENSIONSANDCEILINGCONDITIONSPRIORTOAPPROVAL.SOMECEILINGFRAMINGREQUIREDINFIELDBYBUILDER.PORT ST. LUCIEWARNING:Backcharges Will Not Be Accepted Regardless of Fault Without PriorNotification By Customer Within 48 Hours & Investigation ByBuilders First Source.TCLL:SCALE:TOTAL:ROOFPITCH:6/12CEILINGPITCH:3/12TOPCHORDSIZE:2 X 4BOTTOMCHORDSIZE:2 X 4OVERHANGLENGTH:12"ENDCUT:PLUMBCANTILEVER:-ROOFSPACING:24"FLOORSPACING:N/AFLOORDEPTH:N/ADROPPEDGABLES:YESBUILDINGCODE:FBC2020-JOB # :3/16"=1'-0"940 West Jefferson StreetBrooksville, FL 34601Ph. (352) 796-7232Fax (352) 754-6078PSFmodel:DURATION:MAIN WIND FORCE RESISTING SYSTEM/C-C HYBRID WINDASCE7-16EXPOSURE CATEGORY:OCCUPANCY CATEGOR:WIND LOAD:WIND IMPORTANCE FACTOR:TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSF BOTTOMCHORD LIVE LOAD NONCONCURRENT WITH ANY OTHERLIVE LOADSROOFLOADINGPSF-40CAUTION!!!DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRINGTO THE ENGINEERING DRAWINGS AND BSCI-B1 SUMMARYSHEETS.ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TOLOADING TRUSSES. (ie. SHEATHING, SHINGLES, ETC.)ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TOINSTALLING TRUSSES.REFER TO FINAL ENGINEERING SHEETS FOR THEFOLLOWING:1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE.2) BEARING BLOCK REQUIREMENTS.3) SCAB DETAILS (IF REQUIRED)4) UPLIFT AND GRAVITY REACTIONS.city:address:This Drawing Must BeAND Returned Before FabricationWill Begin. For Your Protection Check All Dimensions AND ConditionsPrior To Approval Of Plan.SIGNATURE BELOW INDICATES ALL NOTES and DIMENSIONSHAVE BEEN ACCEPTED.DATE:_______________________________BY:___________________________2.1.25-BCDL:4.PSF10--lot/block:1.TOTAL:2711493subdivision:TCDL:02/03/20213.DATE:PLAN DATE:BCDL:VILLA TOWNHOMESFLOORLOADINGAPPROVAL:PSFPSFPSFproject:ADAMS HOMESTCLL:-DURATION:10PSFREVISIONS:20-TCDL:BUILDER:WJH05/19/2021drawn by:PSFELEVATION "A"-