Loading...
HomeMy WebLinkAboutAPPROVED_10-05-2021_Planset(1) - Reviewed-S&S(1)5.22KWSYSTEM SIZE :6.12KW DC STCVICINITY MAPSITE MAP (N.T.S)A-01SITE MAP &VICINITY MAPTE 'AUNA CROSSNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (6.12KW)33°C0°C0 PSF160MPH (ASCE 7-16)IIC21.78 A(18) ENPHASE IQ7PLUS-72-2-USMICROINVERTERSLINE SIDE TAP IN THE MSPWIND FLOW MAP(2) BRANCHES OF 9 MODULESSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINT OFINTERCONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILSGOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)NATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70SITE MAP & VICINITY MAPA - 01A - 02S - 01SINGLE LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILSINVERTER DATASHEETCOMBINER BOX DATASHEETATTACHMENT DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTSITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORY(18) HANWHA Q.PEAK DUO BLK-G8 340WMODULESRACKING DATASHEETDS - 05THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLE O'NEAL, PE ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.LAYOUT SUBJECT TO CHANGEBASED ON SITE CONDITIONS40.55"68.50" MSP UM (E) UTILITY METER(OUTSIDE HOUSE)(E) SERVICE DROP(E) MAIN SERVICE PANEL(INSIDE HOUSE)ROOF 118" SETBACKPV ARRAY3' SETBACK124'-9"71'-5"124'-9"71'-8"6'-10"64'9'32'-4" DRIVEWAYSAN CARLOS DR A-02 & MODULESROOF PLANMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3.BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS, AND EQUIPMENT DEAD LOADS.GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLEDAS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WINDZONE:WIND ZONE 1: MAX SPAN 2'-0" O.C. WIND ZONE 2: MAX SPAN 2'-0" O.C. WIND ZONE 3: MAX SPAN 1'-6" O.C.2) EXISTING RESIDENTIAL BUILDING ROOF WITH MEAN ROOFHEIGHT 15 FT AND 2"X4" WOOD ROOF TRUSSES SPACED 24" O.C.CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANSAND IN FIELD CONDITIONS.LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT- PRODUCTION METER- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- JUNCTION BOXCP- COMBINER PANEL- CONDUIT- MICROINVERTER- FIRE SETBACKNUMBER OF MODULES = 18 MODULESMODULE TYPE = HANWHA Q.PEAK DUO BLK-G8 340W MODULESMODULE WEIGHT = 43.87 LBS / 19.9 KG.MODULE DIMENSIONS = 68.50" X 40.55" = 19.29 SFNUMBER OF INVERTER = 18 MICROINVERTERSINVERTER TYPE = ENPHASE IQ7PLUS-72-2-US MICROINVERTERSDC SYSTEM SIZE: 6.12KWAC SYSTEM SIZE: 5.22KWNOTES:1.LOCATION OF JUNCTION BOX(ES), ACDISCONNECTS(S), AC COMBINER PANEL(S), ANDOTHER ELECTRICAL EQUIPMENT(S) RELEVANT TOPV INSTALLATION SUBJECT TO CHANGE BASEDON SITE CONDITIONS.2. SETBACKS AT RIDGES CAN BE REDUCED TO 18INCHES IN COMPLIANCE WITH FBC R 324.6.2:TOTAL PLAN VIEW AREA = 2062.88 SQFTTOTAL PV AREA = 18(68.50 IN)(40.55 IN)/(144 IN^2) = 347.21 SQFT( 347.21 SQFT/ 2062.88 SQFT)100 = 16.83 %TOTAL PV AREA POPULATES 16.83 % OF TOTALPLAN VIEW AREA AND IS WITHIN THE 33%REQUIREMENT.M- METER MAIN COMBO MSP UM (E) UTILITY METER(OUTSIDE HOUSE)(E) SERVICE DROP(E) MAIN SERVICE PANEL(INSIDE HOUSE)ROOF 118" SETBACKPV ARRAY3' SETBACKJB(E) BACK YARD(E) FRONT YARDACDCP (N) AC DISCONNECT(N) COMBINER PANELCONDUIT RUNROOF ACCESS POINTROOF ACCESS POINTROOF ACCESS POINT S-01ARRAYLAYOUTROOF DESCRIPTION:SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809WIND LOAD INFORMATION:THIS SYSTEM HAS BEEN DESIGN TO MEETTHE REQUIREMENTS OF THE 7TH EDITION OFTHE FLORIDA BUILDING CODE AND USED THE FOLLOWING DESIGN PARAMETERS: ULTIMATE WIND SPEED: 160 MPHEXPOSURE CATEGORY: CRISK CATEGORY: II MEAN ROOF HEIGHT: 15 FEET ROOF SLOPE: 7-20°LEGENDS- VENT, ATTIC FAN(ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- RAFTERS / TRUSSES- FIRE SETBACKWIND ZONE 1- WIND ZONE 1- WIND ZONE 1'WIND ZONE 2- WIND ZONE (2)- WIND ZONE (2r)- WIND ZONE (2e)- WIND ZONE (2n)WIND ZONE 3- WIND ZONE (3)- WIND ZONE (3r)- WIND ZONE (3e)- RAIL- METAL SEAM(ROOF #1)MODULES - 18ROOF TILT - 20°ROOF AZIMUTH - 180°TRUSSES SIZE - 2"X4" @ 24" O.C.42'-4"7'-2"9'-5"55'-4"10'-3"6'-6"ROOF #118" SETBACKSOLAR MODULE3' SETBACK PHOTOVOLTAIC MODULE GENERAL NOTES:1. APPLICABLE CODE: 2020 FLORIDA BUILDING CODE 7th ED. & ASCE 7-16MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON AWOOD ROOF TRUSS AS EMBEDMENT MATERIAL.3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO AMAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOTEXCEED 30'-0" MEAN ROOF HEIGHT.4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511.5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TOMANUFACTURERS MANUAL FOR ALL ARCHITECTURAL, MECHANICAL,ELECTRICAL AND SOLAR SPECS.6. ALL ALUMINIUM COMPONENTS SHALL BE ANODIZED ALUMINIUM 6105-T5 UNLESSOTHERWISE NOTED.7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.8. ALL RAILING AND MODULES SHALL BE INSTALLED PERMANUFACTURERS' INSTRUCTIONS.9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCEWITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATEDWIND LATERAL AND UPLIFT FORCES AND EQUIPMENT DEAD LOADS.S-02STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809BILL OF MATERIALROOF TECH MINI: 66Q RAIL LIGHT: 9Q MOUNT END CLAMP: 12Q MOUNT MID CLAMP: 30Q MOUNT GROUND LUG : 3HANWHA Q.PEAK DUO BLK-G8 340W: 18 ENPHASE IQ7PLUS-72-2-US MICROINVERTERS: 18 60A FUSED AC DISCONNECT: 1SOLAR MODULERAFTERSWOOD SHEATHINGRT MINI BASETWO 5X60MM WOODSCREWS INTO CENTEROF TRUSSL FOOTQUICK MOUNT QRAIL LITE NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURERAND MODEL NUMBER, INVERTER MANUFACTURER AND MODELNUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.E-01SINGLELINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809SOLAR ARRAY (6.12KW-DC STC)(18) HANWHA Q.PEAK DUO BLK-G8 340W MODULES(2) BRANCHES OF 9 MODULESINVERTER SPECIFICATIONSMANUFACTURERENPHASEMODEL NO.IQ7PLUS-72-2-USMAX DC INPUT VOLTAGE60 VMAX OUTPUT POWER290 VANOMINAL AC OUTPUT VOLTAGE 240 VNOMINAL AC OUTPUT CURRENT1.21 AMODULE SPECIFICATIONMODEL NO.HANWHA Q PEAK DUO BLK-G8 340PEAK POWER340WRATED VOLTAGE (Vmpp)33.34 VRATED CURRENT (Impp)9.90 AOPEN CIRCUIT VOLTAGE (Voc)40.70 VSHORT CIRCUIT CURRENT (Isc)10.40 APER FL. STATUE 377.705 (REVISED 7/1/2017) I, MINDY NICOLE O'NEAL PE#69779, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE.G(N)JUNCTION BOX1 STRING OF9 MODULES WITHMICROINVERTERS1 STRING OF9 MODULES WITHMICROINVERTERS20A/2P20A/2PGENVOY IQ15A/2P(N)IQ AC COMBINER PANEL(2) #10 AWG THWN-2 - L1(2) #10 AWG THWN-2 - L2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(E)200A(N)60A AC DISCONNECT FUSEDUMGNG30A/2P200A(E)MAIN SERVICE PANEL120/240V(3) #10 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNLINE SIDE TAPENPHASE Q CABLES(1) #6 AWG BARECOPPER CONDUCTOR(3) #10 AWG THWN-2IN 3/4" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUN ELECTRICAL NOTESE-02WIRINGCALCULATIONSMAX VOLTAGE DROP CALCULATIONCABLE SIZECABLE DESCRIPTIONONE WAYDISTANCE INFEET (D)BRANCHCURRENT (I)RESISTANCE OFCONDUCTOR(R)VOLTAGE (V)% VOLTAGEDROP=(0.2*D*I*R)/V#10 THWN-2JUNCTION BOX TOCOMBINER PANEL2021.781.242400.45SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809ELECTRICAL CALCULATIONS:1. CURRENT CARRYING CONDUCTOR(A)BEFORE IQ COMBINER PANELAMBIENT TEMPERATURE = 33°CCONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a)GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY= (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)= [(9 x 1.21) x 1.25] / 0.96 / 0.8= 17.72 ASELECTED CONDUCTOR - #10THWN-2 ...NEC 310.15(B)(16)(B)AFTER IQ COMBINER PANELTEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(18x 1.21) x 1.25] /0.96 / 1=28.36 ASELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.15(B)(16)2.PV OVER CURRENT PROTECTION ..NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25=(18 x 1.21) x 1.25 = 27.23 ASELECTED OCPD = 30ASELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #10 THWN-2 ... NEC 250.122(A)1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL ANDLABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR 75DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.14 4.4. WiRING, CONDUIT AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO AND LOCATED AS CLOSE AS POSSIBLETO THE NEAREST RIDGE, HIP, OR VALLEY.5. WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAICSYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE.13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). WARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 21.78 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICEPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDE-03WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING PHOTOVOLTAICPOWER SOURCE!727-571-4141EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSSHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809SYSTEMLABELINGLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION, COMBINER PANEL(PER CODE: NEC 690.13(B))LABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54)LABEL LOCATION:CONDUIT RUNWAY(PER CODE: NEC690.31(G)(3)(4))LABEL LOCATION:MAIN SERVICE DISCONNECT(NEC 705.12(B)(3-4) & NEC 690.59)ADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, ANDLOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1)·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED. NEC 110.21(B)(3)·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3LABEL LOCATION:COMBINER PANEL, AC DISCONNECT(PER CODE: NEC 690.52)LABEL LOCATION:POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT(PER CODE: NEC 705.12 (B)(2)(c))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]DATA PER PANELLABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C)(3))IFC 605.11.3.1(1) & 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the arrayNOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATINGFOR AC MODULE PROTECTION PER CIRCUIT-2402901.2120VVA 60 HzAA DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-02DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-03DATASHEETCOMBINER BOXSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-04DATASHEETATTACHMENTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-05DATASHEETRACKINGSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROVR10/05/2021DESIGNERREVIEWERDATETE 'AUNA CROSS 7506 SAN CARLOS DR, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809