Loading...
HomeMy WebLinkAboutLETTER-DESIGN PRESSURE CALCULATIONS'. Architectonic Inc St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 July 6, 2021 RE: 5600 West Midway Road, Fort Pierce To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed Roofing is incompliance with the 2020 Florida Building Code, 155 mph wind zone, exposure "C", risk category il. Exposure "C" Multiplier for 20' mean roof height is 1.29 Wind Zone 1 32.6 x 1.29 = 42.1 Wind Zone 2 43.1 x 1.29 = 55.6 Wind Zone 3 55.3 x 1.29 = 71.4 Required Design Pressures: +/-71.4 Product Design Pressure: +/-80 Product: MBCI Metal Roof and Wall Systems, Roof Deck PBR Panel, FL# 11819.5 A Li SFq � Micha Seal AIA •;� �R96 ; V k�itectonic, Iqc`�� "tln- Dof REVIEWED 613 CODE COMPLIANCE ST. LUCIE COUNTY ROCC Q�' y yGr� n +\ V. %'' 4 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1