Loading...
HomeMy WebLinkAboutAPPROVED FL20867_R2_AE_PER4418 SS 2016-08-06, BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Product Evaluation Report Of Trinity Glass International '6'8" Glazed Fiberglass Door Outswing" (Impact) Sub for Florida Product Approval FL# FL20867 Report No. 4418 Current Florida Building Code 1Method: Category: Category: Product: Material: Product Dimensions: 398 E Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com 1 - D (Engineering Evaluation) Exterior Door Swinging Exterior Door Assemblies Glazed Fibergiass Door Outswing Fiberglass See Installation Instructions, FL-20867.1 Prepared For: Trinity Glass International 33625 1St Way S Federal Way, WA 98003 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 07/25/2016 Contents: Evaluation Report Pages 1-4 Digitally signed by Hermes F. Norero, P.E. Reason: I amapproving thisdocument Date: 2016.08.26 14:47:07 -04'00' 00 4SS F....... S e .... 0 :0 S -:..7... E*.3 * i 3 11: TT i Or i : 4/ 21 1..... 4 0 05... * f %>sigil.IG»«If HermdY.'M#8,P.E. Florida No. 73778 / BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub-Category: Compliance Method: Product Name: Scope: Limits of Use: Trinity Glass International Exterior Door Swinging Exterior Door Assemblies State Product Approval Method (1)(d) Glazed Fiberglass Door Outswing (Impact) Date: 07/25/2016 Report No: 4418 This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Trinity Glass International based on Method ld of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions FL-20867.1, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing FL-20867.1 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions FL-20867.1 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 / BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Quality Assurance: Performance Standards: Referenced Data: Date: 07/25/2016 Report No: 4418 The manufacturer has demonstrated compliance in Accordance with the Florida Building Code and Florida Product Approval system for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation Management Institute. (FBC Organization # QUA1789) The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM 283-04 • ASTM E330-02 • ASTM E331-00 • AAMA 1304-02 1. Product Testing performed by (FBC Organization # TST1910) Report #: F5877.01-109-18, Report #: F7081.01-109-18, Report #: F8603.01-109-18, Report #: 85950.01-106-18, Report #: C3995.01-106-18, Report #: D8467.01-106-18, Report #: D8467.02-106-18, 2. Product Testing performed by (FBC Organization # TST4317) Report #: TEL 06-0918-1, Report #: TEL 01370051, Report #: TEL 01370210, Report #: TEL 01470437, Report #: TEL 04251336, Report #: TEL 01370079, Report #: TEL 02010411, Report #: TEL 02010412, Report #: TEL 08-01370020, Architectural Testing, Inc. Report Date: 04/12/2016 Report Date: 05/12/2016 Report Date: 05/27/2016 Report Date: 08/29/2012 Report Date: 12/10/2012 Report Date: 01/23/2015 Report Date: 01/23/2015 Testing Evaluation Laboratories, Inc. Report Date: 10/10/2006 Report Date: 10/01/2008 Report Date: 12/21/2009 Report Date: 11/30/2011 Report Date: 05/05/2015 Report Date: 12/05/2008 Report Date: 10/11/2011 Report Date: 10/11/2011 Report Date: 06/10/2008 3. Product Testing performed by ETC Laboratories (FBC Organization # TST2411) Report #: ETC-05-781-16179.0, Report Date: 12/21/2005 Report #: ETC-05-781-16208.0, Report Date: 12/21/2005 Report #: ETC-05-781-17122.0, Report Date: 10/19/2005 Report #: ETC-05-756-10828.0, Report Date: 12/31/2001 Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 / BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Installation: Design Pressure: Date: 07/25/2016 Report No: 4418 Refer to Installation Instructions (FL-20867.1) for anchor spacing and more details of the installation requirements. Refer to Installation Instructions (FL-20867.1) for design pressures based on size, configuration, and glass types. Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4