Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1ST FLOOR IMPROVEMENTS
OFFICE CONFERENCE $t. Lucie Count BOCC EXISTING y 2300 Virginia Avenue ❑ ❑ ; r ; Fort Pierce, Florida 34982 T: 772.462.1100 i CORRIDORi ® OFFICE EXISTING i EXISTING NEW F OFFICE I PROVIDE AS-BUILT i LOCATIONS OF r'Nv PRINTER/FILE EXISTING POWER, D I ROOM DATA BREAK ROOM FE EXISTING I i F EXISTING I General Contractor: PRINTER/FILE14 NEW i CORRIDOR (PRINTER) i WEST ADMINISTRATION ROOM OFFICE , EXISTING = — IL GROUND FLOOR I — CUSTOMER SERVICE CORRIDOR ® EXISTING CORRIDOR i i CORRIDOR CUSTOMER � �'� I I EXISTING � CORRIDOR I I I F FE L--- J PROVIDE POWER -- -- - - USB FOR FUTURE S/ CUSTOMER KIOSKS � I OFFICE I Keyplan: = TAX COLLECTOR OFFICES 36"AFF EXISTING NOTE:FIRE LARGED ii CUSTOMER OFFICE PULL-DOWN AND I SERVICE BBY AITING i CUSTOMER STROBE TO REMAIN I I ENLARGED LOBBY/WAITING SERVICE OFFICE - -�� 66' IL A -&F` WGRK— --.a-- — — — — — — — - - - - - - - - - -- EXISTING FIRE MAXIMUM NEW EMERGENCY EXISTING L--J FE EXTINGUISHER El-> TRAVEL DISTANCE EMERGENCY ®EXIT (EXISTING) FIRE ALARM EXISTING 36" AFF LIGHTING STROBE Life Safety Plan 1/8" = V-0" Existing Building Plan 1/32" = 1'-0" _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - EXCEPT AS NOTED, =Q-- COMBINATION H H EXISTING ELECTRIC TO REMAIN AREA OF WORK 4 RECEPTACLE USB ❑ = Area of Improvements - - - - - - - - - - - - - - - - - - - - - _ - - - - - - - - - - - - - - - - - - - - - - - - _- - - - Electrical Plan 1/8" = V-0" Issues: — OFFICE CONFERENCE — No.: Date: Description: EXISTING EXISTING - - - - - - - - - - - - - - - - - - - - - - - - - A 06.22.2021 REVIEW/COMMENT OFFICE CONFERENCE EXISTING EXISTING B 06.24.2021 REVIEW/COMMENT I I I I 01 06.25.2021 FOR PERMIT L7 REMOVE EXISTING DOOR, C i D FRAME I OPENING, OFFICE EXX ISTINISTING i DRYWA , PAINT TO I I EXISTING MAT EXISTING ENCLOSE DOOR CORRIDO OPENING OFFICE EXISTING PRINTER/FILE NEW EXISTING ROOM OFFICE BREAK ROOM EXISTING EXISTING I FILING NEW OFFICE FILES FILES i � CEILING AND � � � CEILING AND LUMINAIRES LUMINAIRES BREAK ROOM I I - I TO REMAIN I � CORRIDOR i I 3AND FRADR TO REMAIN I � EXISTING ' — I EXISTINGDOR TCH EXISTI G ----- - - CUSTOMER SERVICE ,' , CORRIDOR ` LING AND 4CT OPENING IN WALL i I CUSTOMER SERVICE � �� i LUMINAIRES Project:i Project: i GLAZING AT i i FOR NEW DOOR 3-0" i EXISTING TO REMAIN i CORRIDOR � OPENINGS TO BE I I WIDE, MATCH CORRIDOR i i CORRIDOR ENCLOSE DOOR I ! / REMOVED I I EXISTING DOORS I I I I EXISTING OPENING CUSTOMER SERVICE T I I \ �� I I I CEILING AND LUMINAIRES ----, _I I _ LUMINAIRES TO REMAIN i I I F I I I FUTURE CUSTOMER TO REMAIN J i i I ---- ---- KIOSK(S) LOCATION ' II Ground Floor Offices n FT-7 OFIICE I . I I I T I I CUSTOMER XXIST NG ' ' Planning and i SOFFIT, WALLS, DOORS, CEILING OFFICE I I OFFICE ENLARGED LOBBY/WAITING SERVICE GRID TO BE REMOVED (TYP.) I I I I 396 SF _ OFFICE I ENLARGED LOB Y/W ITIN CUSTOMER Development "'XPA DED EILI G TO MATCH LOBBY �% ,�' I i i i oo EXISTING LOBBY CEILINGSERVICE HEI HT �❑ I i BUILT-IN STAFF CEILING AND Services II II I DESK SET 30' LUMINAIRE I Pierce, Florida CUT' PENING IN WALL BUILT-IN CUSTOMER TO REMAIN PASS-THROUGH SERVICE COUNTER AFF Fort I i F111M T] 17 F CLOSET I LJ i (REF. ELEVATION) _____ ________________J F1 01 _i - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - T � 3 I AREA OF WORK AREA OF WORK - _ - _ _ _ - - _ _ _ _ Drawing Title: Demolition Plan 3/16 - 1 -0 Improvements Plan 3/16 - 1 -0 AREA OF WORK PDS 1ST FLOOR - - FLUORESCENT �❑ AIR ❑ AIR LOBBY, OFFICE CODES REVIEW: FIXTURE SUPPLY RETURN 3 3-WAY IMPROVEMENTS DEMOLITION NOTES: THE SCOPE OF WORK CONSISTS OF THE RECONFIGURATION OF CHAPTER 13 ENERGY EFFICIENCY Reflected Ceiling Plan 1. THIS DEMOLITION PLAN SHOWS GRAPHIC AND WRITTEN INFORMATION CONCERNING THE EXISTING AN EXISTING LOBBY AND OFFICE INTO A LARGER LOBBY (396 SF). 1/8" = V-0" Drawn: Issue Date: SPACE. THIS IS INCLUDED AS "INFORMATION ONLY" REPRESENTING AVAILABLE RECORD INFORMATION THE OCCUPANCY IS CONSIDERED TO BE BUSINESS GROUP 'B'. THE FLORIDA BUILDING CODE - ACCESSIBILITY, 7TH EDITION (2020) PWJ 06.25.2021 OF THE ORIGINAL LEASE DRAWINGS PLUS FIELD NOTATIONS. SOME MODIFICATIONS MAY HAVE BEEN WORK CONSISTS OF INTERIOR IMPROVEMENTS, INCLUDING MADE AND NOT SHOWN. THIS INFORMATION IS FOR THE CONTRACTOR'S REFERENCE AS MAY BE ELECTRICAL AND MECHANICAL. NFPA 1 , FIRE CODE, 2018 EDITION PROPOSED EXPANDED Checked: Scale: USEFUL. CODES REFERENCED: CHAPTER 1 ADMINISTRATION LOBBY CEILING HEIGHT SECTION 1 .14 PLAN REVIEW 9'-6" (MATCH EXISTING) 2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DETERMINE THE SCOPE OF WORK FLORIDA BUILDING CODE 7TH EDITION (2020) CHAPTER 6 CLASSIFICATION OF OCCUPANCY Project No.: Sheet No.: REQUIRED. FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020): SECTION 6.1 CLASSIFICATION OF OCCUPANCY EXISTING OFFICES NFPA 1 , NFPA 101 6.1 .1 1 BUSINESS CEILING HEIGHT 8'-4" �- CHAPTER 10 GENERAL SAFETY REQUIREMENTS 3. THE CONTRACTOR SHALL EXAMINE THE EXISTING BUILDING AND WORK SHOWN BY ALL CONTRACT SYNOPSIS OF APPLICABLE CODES CHAPTERS/SECTIONS: CHAPTER 14 MEANS OF EGRESS DOCUMENTS TO DETERMINE THE SCOPE OF DEMOLITION REQUIRED WHETHER SPECIFICALLY SHOWN CHAPTER 20 OCCUPANCY FIRE SAFETY OR NOT. FLORIDA BUILDING CODE - EXISTING, 7TH EDITION (2020) SECTION 20.13 BUSINESS OCCUPANCIES 4. REFER TO MECHANICAL& ELECTRICAL DEMOLITION NOTES AND MEP DOCUMENTS FOR EXTENT OF CHAPTER 6 CLASSIFICATION OF WORK NFPA 101 , LIFE SAFETY CODE, 2018 EDITION THE ATTACHED PLANS HAVE BEEN DESIGNED FOR AND ARE DEMOLITION OF THOSE SYSTEMS. SECTION 603 ALTERATION - LEVEL 2 IN COMPLIANCE WITH THE 7TH EDITIONS OF THE FLORIDA 603.2 APPLICATION. LEVEL 2 ALTERATIONS SHALL CHAPTER 4 GENERAL BUILDING CODE AND FLORIDA FIRE PREVENTION CODE. COMPLY WITH THE PROVISIONS OF CHAPTER 7 FOR 4.5.3 MEANS OF EGRESS DESIGN IS SITE SPECIFIC AND NOT VALID WITHOUT THE 5. PROTECT ALL EXISTING STRUCTURE, SYSTEMS, FINISHES AND GENERAL CONSTRUCTION THAT ARE TO LEVEL 1 ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 6 CLASSIFICATION OF OCCUPANCY AND AUTHORIZED SIGNATURE AND SEAL OF A REGISTERED REMAIN THROUGHOUT THE COURSE OF THE WORK TO PREVENT DAMAGE OR LOSS. CHAPTER 8. HAZARD OF CONTENTS ARCHITECT.THESE NOTES ARE PART OF THE CONSTRUCTION DOCUMENTS.DO NOT SCALE THESE 6.1 CLASSIFICATION OF OCCUPANCY DRAWINGS,USE FIGURED DIMENSIONS ONLY.IF A FLORIDA BUILDING CODE - BUILDING, 7TH EDITION (2020) 6.1 .11 BUSINESS PASS THROUGH OPENING DISCREPANCY OCCURS,CONTACT THE ARCHITECT FOR 6. CONTRACTOR IS TO VERIFY UTILITY LINE LOCATIONS AND MAINTAIN THOSE THAT SERVE OTHER PARTS CHAPTER 7 MEANS OF EGRESS CLARIFICATIONS. OF THE BUILDING THAT ARE NOT AFFECTED BY THE DEMOLITION. CHAPTER 2 DEFINITIONS 7.3 CAPACITY OF MEANS OF EGRESS CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION TABLE 7.3.1 .2 OCCUPANT LOAD FACTOR 7. PRIOR TO INTERRUPTING OR OTHERWISE AFFECTING ANY SUCH OPERATING SYSTEM, UTILITY OR SECTION 304 BUSINESS GROUP B BUSINESSI 50 SF GROSS 9 SERVICE, CONTRACTOR SHALL CONSULT WITH OWNER'S REPRESENTATIVE TO ESTABLISH A MUTUALLY CHAPTER 10 MEANS OF EGRESS 7.6 MEASUREMENT OF TRAVEL DISTANCE TO EXITS r P 00 SATISFACTORY SCHEDULE FOR CUT OVER, CUT OFF DISRUPTION OR OTHER CHANGE IN THE SECTION 1004 OCCUPANT LOAD REFERENCE LIFE SAFETY PLAN 1 )P �oo OPERATION OF THE AFFECTED SYSTEM, UTILITY OR SERVICE. 1004.1 DESIGN OCCUPANT LOAD CHAPTER 10 INTERIOR FINISH, CONTENTS, AND FURNISHINGS Q oQ ° "°' °°° �� •o TABLE 1004.5 MAXIMUM FLOOR AREA 10.1 GENERAL ALLOWANCES PER OCCUPANT (REFERENCE LIFE 10.1 .1 APPLICATION =~ 8. ALL WORK WILL BE PERFORMED IN THE BEST WORKMANSHIP POSSIBLE IN ACCORDANCE WITH THAT SAFETY PLAN) PROVISIONS IN THIS CHAPTER SHALL APPLY CDQ ° S#v°J®N�P� TRADE'S BEST INDUSTRY STANDARDS. CONFERENCE ROOM 20 SF NET CHAPTER 39 EXISTING BUSINESS OCCUPANCIES w J O° .0 b OCCUPANTS 39.1 GENERAL REQUIREMENTS =� 8'-0" 1 -6" 0 ° a a� o ° 9. NOISE AND DUST IS NOT TO BE DISRUPTIVE TO THE OCCUPIED AREA OF THE BUILDING. PROVIDE SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS 39.1 .1 APPLICATION O:LJ AR00178b, TEMPORARY PARTITIONS AS REQUIRED. DOORWAYS PROVISIONS OF THIS CHAPTER SHALL APPLY N �° ° signed b Peter TABLE 1006.2.1 SPACES WITH ONE EXIT OR Z 9 y EXIT ACCESS DOORWAY 0 D c©2'* 25 18:, 0 10. DEMOLITION IS TO BE DONE IN A CAREFUL AND ORDERLY MANNER SO AS NOT TO DAMAGE FINISHES CHAPTER 12 INTERIOR ENVIRONMENT OQ �� Q�� . 1, 6 OR EQUIPMENT TO REMAIN. SECTION 1210 SURROUNDING MATERIALS �p��obooDaaQ� 06.25.2021 Wall Opening Elevation 1/2 - 1 -0 Peter W. ,Jones Date - AR0017858