Loading...
HomeMy WebLinkAboutAPPROVED Posny Floor Plan(1)e 8 s E �g 4p �E td **It has been verified that existing slabs aboves and below unit are not post —tensioned A Ceilings to be Removed and Reframed i. -ial is Z LLI � 2 Remove Drywall for MEP Work; Wall to be Restored, • �,-_- Per Fire Wall Rating Q' =:r W • F� �qM '�.LU,L t. 3135 ••. O EK m *: ccLIJ s 12 E T or- lU .. ; y r _ d Pf. p•.. F�Z ` zcn U c aX �a S-1 Typical Ceiling Framing 25 Go. Stud Runner Attached to Clip Angle w/ (2) #7 Tek Screws 18 Go. L2"x2"x4" Clip Angle ® 16"o.c. w/ 0.145"x0.5" Shot Pins ® 12"o.c. Existing Reinforced d Concrete Slab; (No Post —Tension) 25 Go. 11" Framing Stud @ 16" o.c. Attached to Steel Stud Runner w/ (3) #7 Tek Screws J" Drywall w/ #7-1" Drywall Screws GENERAL STRUCTURAL NOTES Applicable Codes A. Construction shall be in accordance with the 2014 Edition of the Florida Building Code and ASCE 7-10. The above shall govern except where other applicable codes or the construction Section A —A Fire Wall drawings are more restrictive. Metal Framing A. Studs shall be 25 gauge metal and meet the Existing Reinforced 4—Hour Fire Resistance Rating Steel Stud Manufacturers Association Standards. Concrete Slab; (No Post —Tension) 10" Carbonate Aggregate B. End studs shall be seated firmly in the top and ,.: Concrete w� Type 'X' Drywall bottom runner tracks. Over 1" PT Furring Strip C. All lateral bracing must be fastened at the time wall is erected. (ACI 216.1M-7) D. Use a minimum of 3 Studs at wall corners and intersections. E. All screw connections are based on CCFSS Technical Bulletin Vol. 2 No. 1 which outlines the AISI Specifications for screw connections. A i" clearance must be maintained from all edges of Type 'X' Drywall steel members. over 1" PT Furring F. Provide wind anchors at supports for all roof Strips ® 16" o.c. joists and truss rafters. Anchors/Fasteners shall a be Simpson brand or approved equal. G. Power driven fastener system, expansion anchors, 10" Reinforced masonry screws, and adhesive anhor system Concrete °. 25 Go. 1i"x3j" connections are based on literature published by Shear Wall Metal Studs ® Hilti Fastening System, Inc. Alternate fasteners in 16" o.c. accordance to Hilti specifications are acceptable. ° Verification of Construction Conditions Neighboring Remodel Unit A. Dimensions and elevations of construction are Unit Bathroom for bidding only. B. Contractor shall inspect existing conditions and verify dimensions, elevations, etc.. which affect 25 Ga. 1F"x14" the scope on the construction drawings. Bottom Channel C. The Engineer of Record shall be notified of any Existing Reinforced w/ 1j" Tapcon or variations or discrepancies on the construction Concrete Slab; a Concrete anchor drawings. Any variations of the constructions (No Post —Tension) ® 12" o.c. drawings without the Engineer of Record consent are the responsibility of the contractor and ' owner. 1111111111e1 D. The construction drawings depict a finished `` �0ZA t'� °°, product and all temporary bracing and means ..•••••••.;9 S °'tee and methods of construction are the pQ.•�,EN •••' responsibility of the Contractor. SASS •:� E. All Roofing and Window Products shall be o furnished and installed in accordance to all W applicable governing codes and manufacturer * : of : W e r G specifications. � ��°°9O • • • L O%\• ••� %sve 10tA ® 0 4FSS 0) w H 0 z J 9 w z w 0 oa 10 J_ Q LU w a J W 0 O 2 W S-2