HomeMy WebLinkAboutAPPROVED Metal Panels9/8121, 11:41 AM
Florida Building Code Online
BCIS Home Log In User Registration
bo
r
Product Approval
USER: Public User
IiI�'r,
Hot Topics Submit Surcharge Stars B Facts Puhllcatlons Contact Us BCIS Site Map tanks Search
Product Annrovaf Menu > Prpduct or Application Search > Application List > Application Detail
FL #
FL27499-114
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A, Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL27499 R4 C01 Dyn COL�f
Standard Year
TAS 100 1995
TAS 110 2000
TAS 125 2003
https:/liloFidabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDquHDE2Ywe°/a2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 1/5
9/8/21,, 11:41 AM Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page 0
04/18/2021
04/30/2021
05/03/2021
06/08/2021
0 0 Page 1 / 20 0
FL O
Model, Number or Name
Description
27499.1
DM Class 1000 1" Nallstrip
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 tI 4993 Dwd,pdf
Approved for use outside HVHZ: Yes
Verifled By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Umlts of Use.
FL27499 R4 AE 4991 Eval.odf
Created by Independent Third Party: Yes
27499.2
DM Class 1000 1" Nallstrip,
.032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 4992 Dwa,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4992 Eval.odf
Created by Independent Third Party: Yes
27499.3
DM Class 1050 1 1/2" Nallstrip
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4993 Dw9,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4993 Eval.odF
Created by Independent Third Party: Yes
27499.4
DM Class 1050 1 1/2" Nallstrip
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 11 4994 Dwc,gdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4994 Eval.odf
Created by Independent Third Party: Yes
27499.5
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 11 4995 DW9,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eva[ Report for Limits of Use.
FL27499 R4 AE 4995 Eval.odf
Created by Independent Third Parry: Yes
27499.6
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL27499 R4 II 4996 Dw9,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eva] Report for
FL27499 R4 AE 4996 EvdLpdf
Limits of Use.
Created by Independent Third Party: Yes
27499.7
DM Class 1150 1" Mechanical Seam
26 Ga. Galvalume coated steel roof panel, 21" wide, with 1"
standing seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 4997 DwojWf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
hftps://floddabuilding.org/pr/pr_app_dtl.aspx?param=wOEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 215
9/8/21 11:41 AM
Florida Building Code Online
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL27499 R4 AF 4997 Eval.odf
Umits of Use.
Created by Independent Third Party: Yes
27499.8
DM Class 1500 1 1/2" Mechanical
.032" Aluminum roof panel, 20" wide, with 1 1/2" standing
Seam
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4998 Dwgj&
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4998 Eval.odf
Created by Independent Third Party: Yes
27499.9
DM Class 1500 1 1/2" Mechanical
16 oz. Copper roof panel, 16" wide, with 1 1/2" standing
Seam
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4999 Dw9,gdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Umits of Use.
FL27499 R4 AE 4999 Fval.Ddf
Created by Independent Third Party: Yes
27499.10
OM Class 1500 1 1/2" Mechanical
26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
Seam
standing seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 It 49910 Dwe,gdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49910 Eval.gdf
Created by Independent Third Party: Yes
27499.11
DM Class 1500 1 1/2" Mechanical
.032" Aluminum roof panel, 16" wide, with 1 1/2" standing
Seam
seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 49911 Dw9,7_df
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Umits of Use.
FL27499 R4 AE 49911 Eval.gff
Created by Independent Third Party: Yes
27499.12
DM Class 1500 1 1/2" Mechanical
24 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
Seam
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49912 Dwg,W
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49912 Eval.odf
Created by Independent Third Party: Yes
27499.13
DM Class 1500 1 1/2" Mechanical
24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2"
Seam,
standing seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 lI 49913 PAgj f
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49913 Eval.gyf
Created by Intlependent Third Party: Yes
27499.14
DM Class 1750 1 3/4" Snaplock
24 Ga. Galvalume coated steel roof panel, 18" wide, with I.
3/4" Snaplock seams, attached to metal deck.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 49914 Dwc,gILf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49914 Eval.odf
Created by Independent Third Party: Yes
27499.15
DM Class 1750 1 3/4" Snaplock
.032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams, attached to metal deck.
https://8oddabuilding.org/pr/pr app_dtl.aspx7param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d W5
9/8/21, 11:41 AM
Florida Building Code Online
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49915 Owa,pd(
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49915 Eval.gd(
Created by Independent Third Party: Yes
27499.16
DM Class 1750 1 3/4" Snaplock
.032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 11 49916 DwD,pd(
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Umlts of Use.
FL27499 R4 AE 49916 Eval.Ddf
Created by Independent Thlyd Party: Yes
27499.17
DM Class 1750 1 3/4" Snaplock
24 Ga. gaivalume coated steel roof panel, 18" wide, with 1 3/4"
Snaplock seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 49917 dwa,gd_f
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Unnits of Use,
FL27499 R4 AE 49917 Eval.Ddf
Created by Independent Third Party: Yes
27499.18
DM Gass 2000 2" Mechanical Seam
.032 Aluminum roof panel, 18" wide, with 2" standing seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 49918 Dwc,pd(
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49918 Eval.gd(
Created by Independent Third Party: Yes
27499.19
DM Class 2000 2" Mechanical Seam
24 Ga. gaivalume coated steel roof panel, 18" wide, with 2"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49919 Dwu,gd(
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Llmits of Use.
FL27499 R4 AE 49919 Eval.Ddf
Created by Independent Third Party: Yes
27499.20
OM Class 500 5V Crimp
26 Ga. galvalume coated steel roof panel, 24" wide, with SV
crimp.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 49920 Dwa,pd(
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eva] report for Umits of Use.
FL27499 R4 AE 49920 EvDLW
Created by Independent Third Party: Yes
Go to Page
00 Page l/200
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 phone: 850-487-1824
The State of Florida Is an A4/EED employer. Coovright 2W7-2013 State of Florida.:: privacy Statement :: Accessiblllty Statement :: Refund Statement
Under Florlda law, email addresses are publlc records. If you do not want your e-mall address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the pMce by phone or by traditional mall. If you have any questions, please contact 850.487.1395. "pursuant W section 455.275(t),
Florida Statutes, effed ve October 1, 2012, ]licensees licensed under Chapter 455, F.S. must provide the Department with an email address 4 May have one. The emalls
provided may be used for official wmmuniotion with the licensee. However email addresses are public word. If you do not wish to supply a personal address, please
provide the Department with an emall address which can be made available W the public. To determine if you are a licensee under Chapter 455, FS., please dick here .
product Approval Accepts:
cr Cl M KNCY
https://floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCePABg3°/2bkM6Ffy6ER6Ez MOZCvLCMMgagp/o3dp/o3d 4/5
916/2t, 11A1 AM
Florida Building Code Online
Credit Card
Safe
https:lfloridabuilding.orgtpr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%a2bOsCepABg3%2bkM6Fiy6ER6EzwMOZCvLCMMgag%3d%3d 515
' WOLTERS ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
PRODUCT:
MANUFACTURER:
To all concerned,
15211 97th Road N
West Palm Beach, FL 33412
PhIFx: (561) 225-19k
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
DM CLASS 1000 26 GA. GALVALUME 1" NAILSTRIP 16" WIDE
ROOF PANEL (FLPA# 27499.1)
DYNAMIC METALS, LLC
3201 SE DOMINICA TERRACE
STUART, FL 34997
The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been
tested per TAS 100, TAS 125, and ASTM E2140 by Intertek B&C with results shown in test reports G3443.40-450-
44, G3443.14-45044, and M1607.01-45044. It has also been tested per TAS 110 by PRI Construction Materials
Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "NSS16-HZ" dated 8/16119, signed and sealed by Scott Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE.
3. Supplemental Calculations to support NSS16-HZ, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 7w Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 16" (nominal)
Fastener Spacing across panel: 16" (at Nailstrip)
(Panels overlap with male/female snap fit)
Min. Slope: HVHZ: 1712"
Non-HVHZ: 'V112"
SPECIALIZING IN IMPACf F�515fANf CLKM WALl,5, 5f0MFP0Nf5, & WIN170W5
Option #1
Installation
Option #2
Installation
Max. Design Pressure:
-116 psf
-176 psf
Fastener Spacing:
3" From Ends, 6" Max. O.C.
3" From Ends, 6" Max. O.C.
Min Panel Fasteners:
#10xl" Panclip Fasteners
#10x1" Panclip Fasteners
Panel Sealant:
Continuous bead of Geocell 2300
or 2320 at Nailstdp side of seam
at roof slopes <3712" only)
Continuous bead of Geocel 2300
or 2320 at Nailstrip side of seam
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1" round
plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be
used to prevent galvanic reactions.
Underlavment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section
1507.1.1.1 (min).
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ in areas with windspeeds < 170 mph,1" round
plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be
used to prevent galvanic reactions.
Minimum Substrate: ''/z' (15132" min) 4-ply CDX Plywood or %" solid wood planks (S.G. = .42
min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The'/" wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory fdr fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
5nCI&1ZING IN IMPACT 1�515TANf CLETAINWA15, 5TOUPONT5, & WINPOW5
4. All panel system perimeters, penetrations, and transitions to be
flashed and sealed per the requirements of RAS 133.
5. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
6. Where required by the Florida Building Code, panels shall be
permanently labeled with the manufacturer's name and/or logo, and the
following statement, "Dynamic Metals FL #27499.1, DM Class 1000".
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 31dparty QA provider, to the dimensions shown on Drawing NSS16-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ2-2310920
5VC-0490718 5VC-0360516 SSQ2-2320920
Re -Roofing: The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1511 of the Florida Building Code.
If you have any questions or need more information concerning this approval, please contact me.
Thank you, `%%� XCO
` .
No 62354
Scott olters"
FL PE# 623�, ? 0
APR 15 2(12.10 STATE OF :44
Fc;•�ORInP����
SPECIALIZING IN IMPACT M515TANT MAINWALLS, STOREFRONTS, & WINPOW5
m
� n m
vwi °1 a
N w
O
p X NCN d m
N 0 O
� N �
fb
w
0
a
w
a