Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Ridge Vent Product Approval
918121. 11:57 AM Florida Building Code Online ProfessionalBusiness & -r SCIS Home Log In User Registration Mot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links search Proddbpr USER: P b Approval USER: Public user Product Annroval Menu > Product or Algolicadon Search > ngRlication List > Application datatl • FL # FL38576-RI Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772)872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Standard TAS 100A Year 1995 Product Approval Method Method 1 Option D https:llfloridabuilding.org/pr/pr_app_dtl,aspx?para m=wGEVXQwtDqurhYH%2fNuQVrH7xpTGbOi snRIHRyDs3yAXKxR5eytbrsg%3d%3d 1 /2 918/21, 11:57 AM Florida Building Code Online Date Submitted 06/15/2021 Date Validated 06/15/2021 Date Pending FBC Approval 06/18/2021 Date Approved 08/10/2021 Summary of Products FL a' I Model, Number or Name Description 38576.1 Dynamic Ridge Vent 0.032" Alum or 26 Ga Steel Vented Ridge Cap (Low Slope). Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL38576 Rl It Rid el Dwa2.pd[ Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL38576 R1 AE Rickel Eval2.Ddf Limits of Use. Created by Independent Third Parry: Yes 38576.2 Dynamic Ridge Vent 0.032" Alum or 26 Ga Steel Vented Ridge Cap (High Slope) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL38576 RI 11 Rid D42,Qvsg2,gIff Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eva[ Report for FL38576 Rl AE Ridael Eva12.Ddf Limits of Use. Created by Independent Third Party: Yes Ba[M Nevl Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Flonda Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response W a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wM an email address If they have one. The emails provided may be used for ofOtlal communication with the licensee. However email addresses are public record. If you do not wish Io supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . product Approval Acoepb: ® U IFNI iCl"cM Credit Card Safe https:llfloridabuilding.org/prlpr app_dti.aspx?param=wGEVXQwtDqurhYH%2fNuQVrH7xpTGbQlsnR[HRyDs3yAXKxR5eytbmg%3d%3d 2/2 11 WOLTERS ENGINEERING ENGINEERING, DRAFTING, CONSULTING 15211 971h Road N West Palm Beach, FL 33412 Ph/Fx: (561) 225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DYNAMIC VENTED RIDGE CAP (HIGH SLOPE) (FLPA# 38576.2) MANUFACTURER: DYNAMIC METALS, LLC 3201 SE DOMINICA TERRACE STUART, FL 34997 To all concerned, The Dynamic Vented Ridge Cap (High Slope) is manufactured by Dynamic Metals LLC from 0.032" Fluropon coated aluminum (25 ksi min) or 26 Ga. galvalume or Fluropon coated steel (50 ksi min). The vented ridge cap meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panels have been tested per TAS 100(A) by Intertek B&C, with results shown in test report M1246.01-450-18. It has also been tested per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing 'DMRVHS-HZ" dated 4119/21, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 4. Supplemental Calculations to support DMRVHS-HZ, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This system is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Ridge Cap Width: 121/2" (Length is unlimited) Maximum Ridge Cap Height: Varies (Based on roof slope) Min. Slope: 3712" 5FECIALIZIN6 IN IMPACTEE515fANrCLRrNNWA15, %OPTROW5. & WINPOW5 Minimum Substrate: '/Y (15/32" min) 5-ply CDX Plywood or 3/:' solid wood planks (S.G. = .42 min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank nails spaced 6" on center. Note: The'/4" wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer or Structural panels with 16 Ga. (min) Steel Purlins. Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133. 5. Rational analysis, provided by a Florida licensed ArchitecUEngineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. If you have any questions or need more information concerning this approval please contact me. Thank you, 4VO� •` 9G DENS• 9s'• �2 Scott Wolters No 62354 FL PE# 62354 a JUN 14 2021 ; p'•, STATE OF :��/Z ' T (c �4OR10..���?`: %111!Iliiti' SPECIALIZING IN IMPAU e95TANT CUI?MAINWALLS, STOMKON5, & WINVOW5 _jau jojawjywwAp@ojm,:IIVV43 SW m__� elm m� _ 3S TOZE� �\ _ -- gd lw 7a»Nm (� | 4 q Z CL0 ƒ \ © R �§b § / ~ V) CL ! ■ \ � / > - k , K� |; M. !! (§ ■` -� � IL 0 o � ¢ |\■ L U fL « LU CD<3 ) {q f, | � d 12 E 2|=7®| o � o xa,..Zw � LU > z x \ / Q � 2 S :k?��©«» S q 2 |;•§�|Q|5 « w J.WM- 2 m m 4 ,4 q m > c o 9 o