Loading...
HomeMy WebLinkAboutHealth SurveyPlanning & Development Services Department fY,tgxrS�M Building & Code Regulations Division *et3� }tea 2300 Virginia Avenue, Fort Pierce, FL 34982 -(772) 462-1553 L111-J� Certification for Design Load Compliance Project Name: MELISSA 2 MODEL Project Address: EASY ST. PermitIf: Occupancy Type: R Construction Type: 1 INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit, oAny non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2017 6th Edition with 20 _Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: IIX II III IV Exposure Category: X B C- D 4. Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 15 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding, Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 16.0 16.0 16.0 27.6 27.6 N/A Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: -25.3 -44.0 -65.1 -30.0 37.0 N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony:_ N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A FILE /CONCENTRATED 9. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: i certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the buildingcodes current) adopted and enforced 5 Lucie o ced b _ t. ucle Y I Y County. i also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified _- Building (Department Product Approval Submittal Affidavit Permit f# - - Building Address; ON PLANS Contractor: ON PLANS --- ng Sc eciufe i�`wing oors, ver ea Doors, S I mg C7onrs,T xe Gass, (n a -a- ws Sky(Igiifs- -' Opening ID _ EL fi or NOA # _ _Open_ -Product _ Model ff Manufacturer Attachment Method Type, Size, Spacing & Building Product Glass Embedment (DISTANCE FROM CORNER / Design Design - _ Description DISTANCE O.C.)_ _ Pressure Pressure 1, 2, 3, & 4 FL# V S.H. WINDOW 185 SH MI WONOWS & IMPACT 1/4" X 11/4" MIN EMBD. TAPCONS @ 2"/16" O.C. SEE ELEV. +/- 55 17495.1 DOORS 5 FLg 20468.5 _ S.C. DOOR _ _ SMOOTHSTAR THERMA-TRU N/A 1/4"X 1 112" MIN. EMBED TAPCONS @ 6"/14" SEE ELEV. +/- 50 W/SIDELiTE O.C. MAX fi FUt FRENCH DOOR -- SMOOTHSTAR THERMA-TRU - IMPACT 1/4"X 11/2" MIN. EMBED ULTRACONS @ SEE ELEV. +/-55 10975.1 6"/13.75" O.C. MAX --� 1173 _ CLQPAY BLDG 1/4"X 11f 2" MIN, EMBED TAPCONS @ 3"FROM 7 fit# 16546, 5 OHD PRODUCTS N/A ENDS AND 7 1/2" O.C. MAXO.C. MAX. SEE ELEV. +3G 42 Attachment Method: Bldg. Product PRODUCT MODEL 0 MANUFACTUER Type, Size, Spacing, Embedment, Stiff ner, Etc. Design Design " Pressure Pressure NOA 418-0529.03 LAWSON INDUSTRIES INC. 2" X 2"X 1/811 ALUM. ANGLE TO MULL W/ (2)-1114 SEE ELEV. +/- 6R MULLIONS Vertical Mullions SMS 5/16" TAPCON 13/4" EMBED INTO CONC. FL#f 18355.1 I (6) 1 1/4" E.G. ROOFING NAILS PER SHINGE ROOF ��- P1ERrTAG I TAMKO BLDG.� PRODDUCTS {MEETS REC1UlREMTS OF PRODUCT APPROVAL) _ �- Hurricane �- i?angls----- i have reviewed the above product approval Information and approve it. - Name: Paul Welch P.E. Certification Number: 29945 NOTE;3: 1) TH;E CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (1=13C) 2017, FBC 2017 RESIDENTIAL, FBC 2017 PLUMBING CODE, FBC 2017 MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2014 EDITION. S) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. 6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WiTH THE F.B.C. 2017 FOR EXISTING BUILDINGS. 12, ,�" - :_._ ' - -a Ik. O 1 11 1 , 11 I 11 k_ TP.USSrS CANi"ILrVrr �..6 CD Oj • ___.-.. -- e • • e e • • 0 • • 11 IGrr55 e • 8" X 1611 CONC. • - COWMN < ,� W/ # 5 13AF5 coyEff 7 rorai Vrri', s C/ C L O .. g11 L_,) , {;� • 171NIN6 FK - I MA51'rr I = ``� • rGrrss 1, II -�. .Fill 1 II 16 , 1 i' , 1 All ( 1_711 I - II C a I O I c,. I( e �c PWFOOvl # 4 NON-PFAFING I K � 41, rrAMr WAU. (11'f'J _ HVING r00M �l C� W:I:C I � W,I.0 i- -, s mi"Ow- - _ \ 11i13 0 W.I.0 I 00EN C • 1"105F P113 -f --- - J W/C s , f ANr�Y MA51 rf? I.IN:I PAIi-FOOU1 - SI Irl,rT - �" - - - - - 0 ,e l AL� �- W,I C HAI,� PA-1II rM.� I O I-s- -' r-\� Ilil3 h- + \% DC 7V r3 0 clll" W O �J 411 3i I� O " J 1/ 1 411 11 41_ 11 ('� 1-"�11 P I -lose PI V _J \0 1 1 � - - C3 _ Hi FN 0 0 LALIPJVrY f / n rOYrr /IF L o91r H" PF00M # 2 - VV/ C MAIN rGrr"55 - 13CC7r00M - - � 0 NON 1-r�, INSLILArr e A/ C. r r1 VVN.I. W/ r-11 - Mu LMIhING rC,I;r55 • • � � I� I LL �) 2 0 2 X 51 �11 * rGrr55 • C AHIC A(cr-55 L- - - - --I e • • • • • � I ( v� = rN rP.'r II 201-011 1 1_ 1 1 1 t 1 1 �< - - - - - - - - - - - - - 811 001-1 VVAI,I" (111') I i • IN (�000 r51) CONC, rll l 1:17 Cr115 I a - - - - - - - - - - • - A, I - - - - - - - - - - 1 1 -1 I 1 11 ,-II t II 1-.II 1 11 r1 II - /11-411 DOOR/WINDOW SCHEDULE 1. (37 fir' W X 63" 1-1) (DBL) SI125 WINDOW 2 (37 fir' W X 63" I -I) SH25 WINDOW rr 3rr VS 3 3 (37 4 3� II) SH23 WINDOW 4 (27 "' W X 26" I -I) SHIA.2 WINI)O�1' 5 3°6g S.C. DOOR W/ (1.) 12" SIDELITE 6 3°6' FRENCH DOOR 7 1.6°7° OVERHi+�AD GARAGE DOOR A 2s6s SOLED CORE 20 MIN FIRE RATED DOOR. 13 2468 1I.C. INTERIOR DOOR IL-1 2°6s H.C. INTERIOR DOOR D 2()6g POCKET DOOR E 61168 BI-FOLD DOOR F 2o6s H.C. SWING DOOR. G 346s CASED OPENING H 3°6s CASED OPENING J 2668 II.C. INTERIOR DOOR (SWING) Cate: 5 �Z Approved:Florida D_ep%a n of Nealt ,;n , keec ee 'taLlnty TABULATIONS LIVING: 2,232 SQFT COV. PORCH: 200 SQFT ENTRY: 139 SQFT GARAGE: 512 SQFT TOTAL: 3,083 SQFT FLOOF (�/"\I�1 SCAI.f III : 1' /�11 PAUL WELCH INC. MECHANICAL ELECTRLCAL CIVIL ENGINEE 1984 S.W. BILTMORE ST. SUITE #114 PORT ST. LUC:IE, FL 34984 PI -[ONE (772) 785-9888 E-MAIL PWELCHINC@AOL.COM NOV 2 3 2020 PAUL WELCH, RE. I LA REG NO.29945 N r { µAC t1' Ir A E �a { r 1 C� � r SHEET NUMBER OF