Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENCALCS
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Melissa Model II Builder Name: Street: Permit Office: St. Lucie County City,State,Zip: Port St. Lucie, FL,34983 Permit Number: Owner: Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type$1712.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1504.00 ft2 b. Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 11.Ceiling Types (2148.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic(Vented) R=19.0 2148.00 ft2 6. Conditioned floor area above grade(ft2) 2148 b. NIA R= ft2 Conditioned floor area below grade(ft2) 0 c- NIA R= ft2 7. Windows(160.3 sqft.) Description Area 12. Ducts R ft2 a.Sup:Attic, Ret:Attic,AH: Garage 6 105 a. U-Factor: Sgl,U=0.65 160.33 ft2 SHGC: SHGC=0.25 b. U-Factor: NIA ft2 13.Cooling systems kBtulhr Efficiency SHGC: a.Central Unit 45.0 SEER:16.00 c. U-Factor: NIA ft2 SHGC: 14. Heating systems kBtulhr Efficiency Area Weighted Average Overhang Depth: 2.779 ft. Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap:50 gallons 9. Floor Types (2148.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2148.00 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16.Credits CF, Pstat Glass/Floor Area: 0.075 Total Proposed Modified Loads: 60.19 PASS Total Baseline Loads: 60.56 1 hereby certify that the plans and specifications covered by Review of the plans and ��-THE STr this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance r�j �i„ ' ` = with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 5-6-2021 this building will be inspected for 0 ^` ,d compliance with Section 553.908 # ° I hereby certify that this buildinq, as designed, is in compliance Florida Statutes. with the Florida Energy Code. GOD WE,C4� OWNER/AGENT: BUILDING OFFICIAL: DATE: 5/6/2021 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 5/5/2021 6:50 PM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Melissa Model II Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2148 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90 Street: Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City,State,Zip: Port St. Lucie, Family Type: Detached FL, 34983 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2148 17184 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 178 1424 No 2 1 1 Yes Yes Yes 2 WIC 1 36 288 No 0 1 Yes Yes Yes 3 WIC 2 47 376 No 0 1 No Yes Yes 4 Pantry 12 96 No 0 1 No Yes Yes 5 Toilet 24 192 No 0 1 Yes Yes Yes 6 Master Bath 195 1560 No 1 1 Yes Yes Yes 7 Laundry 54 432 No 1 1 No Yes Yes 8 Bath 45 360 No 0 1 No Yes Yes 9 Dining Room 153 1224 No 2 1 Yes Yes Yes 10 Kitchen 216 1728 Yes 2 1 No Yes Yes 11 Living Room 342 2736 No 2 1 Yes Yes Yes 12 Foyer 50 400 No 0 1 Yes Yes Yes 13 Bedroom 2 240 1920 No 2 1 1 Yes Yes Yes 14 Bedroom 4 203 1624 No 2 1 1 Yes Yes Yes 15 WIC4 30 240 No 0 1 Yes Yes Yes 16 Bathroom 56 448 No 0 1 No Yes Yes 17 WIC 3 30 240 No 0 1 Yes Yes Yes 18 Bedroom 3 205 1640 No 2 1 1 Yes Yes Yes 19 Hall 32 256 No 0 1 No Yes Yes 5/5/2021 6:50 PM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Master Bedroom 33 ft 178 ft2 ---- 1 0 0 2 Slab-On-Grade Edge Insulatio WIC 1 6 ft 36 ft2 ---- 1 0 0 3 Slab-On-Grade Edge Insulatio WIC 2 1 ft 47 ft2 ---- 1 0 0 4 Slab-On-Grade Edge Insulatio Pantry 1 ft 12 ft2 ---- 1 0 0 5 Slab-On-Grade Edge Insulatio Toilet 4 ft 24 ft2 ---- 1 0 0 6 Slab-On-Grade Edge Insulatio Master Bath 11 ft 195 ft2 ---- 1 0 0 7 Slab-On-Grade Edge Insulatio Laundry 1 ft 54 ft2 ---- 1 0 0 8 Slab-On-Grade Edge Insulatio Bath 1 ft 45 ft2 ---- 1 0 0 9 Slab-On-Grade Edge Insulatio Dining Room 26 ft 153 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Kitchen 1 ft 216 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio Living Room 11 ft 342 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Foyer 5 ft 50 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulatio Bedroom 2 21 ft 240 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulatio Bedroom 4 28 ft 203 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulatio W IC4 5 ft 30 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulatio Bathroom 1 ft 56 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulatio WIC 3 5 ft 30 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulatio Bedroom 3 33 ft 205 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulatio Hall 1 ft 32 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch I/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2402 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 2148 ft2 N N 5/5/2021 6:50 PM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Master Bedroom 19 Batt 178 ft2 0.1 Wood 2 Under Attic(Vented) WIC 1 19 Batt 36 ft2 0.1 Wood 3 Under Attic(Vented) WIC 2 19 Batt 47 ft2 0.1 Wood 4 Under Attic(Vented) Pantry 19 Batt 12 ft2 0.1 Wood 5 Under Attic(Vented) Toilet 19 Batt 24 ft2 0.1 Wood 6 Under Attic(Vented) Master Bath 19 Batt 195 ft2 0.1 Wood 7 Under Attic(Vented) Laundry 19 Batt 54 ft2 0.1 Wood 8 Under Attic(Vented) Bath 19 Batt 45 ft2 0.1 Wood 9 Under Attic(Vented) Dining Room 19 Batt 153 ft2 0.1 Wood 10 Under Attic(Vented) Kitchen 19 Batt 216 ft2 0.1 Wood 11 Under Attic(Vented) Living Room 19 Batt 342 ft2 0.1 Wood 12 Under Attic(Vented) Foyer 19 Batt 50 ft2 0.1 Wood 13 Under Attic(Vented) Bedroom 2 19 Batt 240 ft2 0.1 Wood 14 Under Attic(Vented) Bedroom 4 19 Batt 203 ft2 0.1 Wood 15 Under Attic(Vented) W IC4 19 Batt 30 ft2 0.1 Wood 16 Under Attic(Vented) Bathroom 19 Batt 56 ft2 0.1 Wood 17 Under Attic(Vented) WIC 3 19 Batt 30 ft2 0.1 Wood 18 Under Attic(Vented) Bedroom 3 19 Batt 205 ft2 0.1 Wood 19 Under Attic(Vented) Hall 19 Batt 32 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Type Space R--Value Ft In Ft In Area R-N[alue 1 NE=>SE Exterior Concrete Block-Int InsMaster Bedro 4.1 17 0 8 0 136.0 ft2 0 0 0.4 0 2 NW=>NE Exterior Concrete Block-Int InsMaster Bedro 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 3 NW=>NE Exterior Concrete Block-Int Insul WIC 1 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 4 NW=>NE Exterior Concrete Block-Int Insul Toilet 4.1 4 0 8 0 32.0 ft2 0 0 0.4 0 5 NW=>NE Exterior Concrete Block-Int InsLMaster Bath 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 6 NE=>SE Exterior Concrete Block-Int InsdDining Room 4.1 17 0 8 0 136.0 ft2 0 0 0.4 0 7 SE=>SW Exterior Concrete Block-Int InsdDining Room 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 8 NE=>SE Exterior Concrete Block-Int Insilliving Room 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 9 SW=>N Exterior Concrete Block-Int Insul Foyer 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 10 SW=>N Exterior Concrete Block-Int InsuBedroom 2 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 11 NW=>NE Exterior Concrete Block-Int InsuBedroom 2 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 12 NE=>SE Exterior Concrete Block-Int InsuBedroom 4 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 13 SE=>SW Exterior Concrete Block-Int InsuBedroom 4 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 14 SE=>SW Exterior Concrete Block-Int Insul W IC4 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 15 SE=>SW Exterior Concrete Block-Int Insul WIC 3 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 16 SE=>SW Exterior Concrete Block-Int InsuBedroom 3 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 17 SW=>N Exterior Concrete Block-Int InsuBedroom 3 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 18 NW=>NE Exterior Concrete Block-Int InsuBedroom 3 4.1 3 0 8 0 24.0 ft2 0 0 0.4 0 19 SE=>SW Garage Frame-Wood Master Bath 11 14 8 112.0 ft2 0.23 0.4 0 20 SE=>SW Garage Frame-Wood Laundry 11 6 8 48.0 ft2 0.23 0.4 0 21 SE=>SW Garage Frame-Wood Bath 11 5 8 40.0 ft2 0.23 0.4 0 5/5/2021 6:50 PM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent V # Ornt To Wall Type Space Cavity Width Height Sheathing Framing Solar Belo lue Ft In Ft In Area i Fraction Ab w 22 SW=>N Garage Frame-Wood Foyer 11 1 8 8.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW=>N Wood Foyer None .39 3 6 10 20.5 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 Ni 1 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 1 ft 0 in 1 ft 4 in None None 2 NW=>NE 4 Metal Low-E Single Yes 0.65 0.25 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None 3 NW=>NE 5 Metal Low-E Single Yes 0.65 0.25 Y 9.0 ft2 1 ft 0 in 1 ft 4 in None None 4 Ni 6 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 1 ft 0 in 1 ft 4 in None None 5 Si 7 Metal Low-E Single Yes 0.65 0.25 Y 20.5 ft2 3 ft 0 in 1 ft 4 in None None 6 Ni 8 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 8 ft 0 in 1 ft 4 in None None 7 SW=>NW 9 Metal Low-E Single Yes 0.65 0.25 Y 6.8 ft2 6 ft 0 in 1 ft 4 in None None 8 SW=>NW10 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 0 in 1 ft 4 in None None 9 Ni 12 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 8 ft 0 in 1 ft 4 in None None 10 SW=>NW17 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 575 ft2 575 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1432 78.56 147.49 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 45 kBtulhr cfm 0.7 1 sys#1 5/5/2021 6:50 PM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ---Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 105 ft2 Attic 30 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan F:b Mar pr JU Oct Nov Dec Jun VHe Jan F A enting HJan Feb �X�MMar ar �X�Apr May rj Jun lX�Jul ri Aug lX�Sep Oct Nov Dec Oct Nov Dec Jun Jul Aug [ Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 0 ft 0.3 Master Bedroom Default(8 Ibslsq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibslsq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibslsq.ft. ft2 ft 0.3 Pantry Default(8 Ibslsq.ft. ft2 ft 0.3 Toilet Default(8 Ibslsq.ft. ft2 ft 0.3 Master Bath Default(8 Ibslsq.ft. ft2 ft 0.3 Laundry Default(8 Ibslsq.ft. ft2 ft 0.3 Bath Default(8 Ibslsq.ft. ft2 ft 0.3 Dining Room Default(8 Ibslsq.ft. ft2 ft 0.3 Kitchen Default(8 Ibslsq.ft. ft2 ft 0.3 Living Room Default(8 Ibslsq.ft. ft2 ft 0.3 Foyer Default(8 Ibslsq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibslsq.ft. ft2 ft 0.3 Bedroom 4 Default(8 Ibslsq.ft. ft2 ft 0.3 W IC4 Default(8 Ibslsq.ft. ft2 ft 0.3 Bathroom 5/5/2021 6:50 PM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibslsq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibsls .ft. ft2 ft 0.3 Hall 5/5/2021 5:50 PM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 7 of 7 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPertormance Index, the more efficient the home. , Part St. Lucie, FL, 34983 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1504.00 ft2 b. Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? Yes a. Under Attic(Vented) R=19.0 2148.00 ft2 6. Conditioned floor area(ft2) 2148 b. NIA R= ft2 7. Windows- Description Area c. NIA R= ft2 a. U Factor: Sgl,U-0.65 160.33 ft2 12. Ducts, location&insulation level R ft2 a.Sup:Attic, Ret:Attic,AH: Garage 6 105 SHGC: SHGC=0.25 b. U-Factor: NIA ft2 SHGC: 13.Cooling systems kBtulhr Efficiency c. U-Factor: NIA ft2 a.Central Unit 45.0 SEER:16.00 SHGC: d. U-Factor: NIA ft2 14. Heating systems kBtulhr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:9.00 Area Weighted Average Overhang Depth: 2.779 ft. Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): NIA ft2 a. Electric Cap:50 gallons EF: 0.95 SHGC(AVG): NIA b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 2148.00 ft2 Credits(Performance method) CF, Pstat b. NIA R= ft2 c. NIA R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building 114E S74 Construction through the above energy saving features which will be installed (or exceeded) o = o in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,,,'''•4 based on installed Code compliant features. Builder Signature: rG Date: 6/6/2021 . Address of New Home: City/FL Zip: Port St Lucie, FL oD WF c�`t *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/5/2021 6:50 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Melissa Model II Builder Name: Street: Permit Office: St. Lucie County City,State,Zip: Port St. Lucie, FL,34983 Permit Number: Y U Owner: Jurisdiction: St. Lucie County W x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceilinglattic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the tap of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind popona and wormna. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fore sprinkler cover plates and walls or cemimnas, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/5/2021 5:50 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 Pro S Job: +� wrightsoft Project Summary ry Date: Entire House By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com Project • • For: Melissa Model II Port St.Lucie,FL 34983 Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21856 Btuh Structure 24180 Btuh Ducts 7668 Btuh Ducts 9508 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29524 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmen�sensible load 32003 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4914 Btuh Ducts 3087 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft�) 2148 2148 Equipment latent load 8001 Btuh Volume(ft3) 17184 17184 Air changes/hour 0.32 0.16 Equipment Total Load(Sen+Lat) 40004 Btuh Equiv.AVF(cfm) 92 46 Req.total capacity at 0.70 SHR 3.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX160481 F AHRI ref Coil ASPT49D14A AHRI ref 201384390 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.5 kW Sensible cooling 31500 Btuh Heating output 28862 Btuh Latent cooling 13500 Btuh Temperature rise 18 °F Total cooling 45000 Btuh Actual airflow 1500 dim Actual airflow 1500 cfiT1 Air flow factor 0.051 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2021-May-0518:46:35 ^M^oksI°�k,�„. --,1.o, r,, Right-Sute®Uriversal201919.0.21RSU08101 Pagel ACCA ts\wrightsoftHVAC\Melissa Model ll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Entire House Master Bedroom 2 E)posed wall 179.0 It 32.0 ft 3 Room height 8.0 ft 8.0 It heat/000l 4 Room dimensions 1.0 x 245.0 It 5 Room area 2148.0 W 245.0 W Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 344 309 1236 675 0 0 0 0 I; CCI 10A-m 1.670 ne 46.76 42.95 20 0 954 876 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 15 0 533 645 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 280 238 952 520 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 15 2 533 619 0 0 0 0 1 B-rlfm 1.130 se 31.64 24.50 7 7 215 167 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 20 20 223 211 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 328 315 1261 689 120 120 480 263 1A-r1om 1.270 sw 35.56 38.29 4 1 142 153 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 9 2 320 360 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 480 390 1562 853 136 106 424 232 ,A-r1om 1.270 nw 35.56 43.03 60 0 2134 2582 30 0 1067 1291 1A-r1om 1.270 nw 35.56 43.03 30 0 1067 1291 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 2148 2148 2947 5263 245 245 336 600 F 22A-tpl 0.989 27.69 0.00 21411 179 4957 0 245 32 886 0 6 c)AED excursion 771 269 Envelope loss/gain 19036 15674 3194 2654 12 a) Infiltration 2820 755 504 135 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 15 3450 2 460 Appliances/other 4300 900 Subtotal(lines 6 to 13) 21856 24180 3698 4149 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 21856 24180 3698 4149 15 Dud loads 35% 39% 76681 9508 35% 39%1 1297 1631 FFTotal room load 29524 33688 4996 5781 Airrequired(dm) 1500 1500 254 257 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101ACCK Page l ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name WIC 1 WIC 2 2 E)posed wall 6.0 ft O ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 6.0 x 6.0 It 1.0 x 47.0 It 5 Room area 36.0 ft' 47.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-r1fim 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 48 48 192 105 0 0 0 0 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 ViV 13A-flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 36 36 49 88 47 47 64 115 F 22A-tpI 0.989 27.69 0.00 36 6 166 0 47 0 0 0 6 c)AED excursion -5 -3 Envelope loss/gain 408 188 64 113 12 a) Infiltration 95 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 502 214 64 113 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 502 214 64 113 15 Dud loads 35% 39%1 176 84 35% 39%1 23 44 FFTotal room load 678 298 87 157 Airrequired(dm) 34 13 4 7 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101 Paget ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Pantry Toilet 2 E)posed wal I O ft 4.0 ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 3.0 x 4.0 It 6.0 x 4.0 It 5 Room area 12.0 ft2 24.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-rlfm 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 32 28 112 61 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 4 1 142 153 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 13A-flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 12 12 16 29 24 24 33 59 F 22A-tpl 0.989 27.69 0.00 12 0 0 0 24 4 111 0 6 c)AED excursion -1 49 Envelope loss/gain 16 29 398 322 12 a) Infiltration 0 0 63 17 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 16 29 461 339 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16 29 461 339 15 Dud loads 35% 39% 61 11 35% 39%1 162 133 FFTotal room load 22 40 623 473 Airrequired(dm) 1 2 32 21 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101 Page ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Master Bath Laundry 2 E)posed wal I 11.0 It O ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 1.0 x 195.0 It 6.0 x 9.0 It 5 Room area 195.0 ft 54.0 ft Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-rlfm 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 88 79 316 173 0 0 0 0 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 9 2 320 360 0 0 0 0 ViV 13A-flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 195 195 268 478 54 54 74 132 F 22A-tpl 0.989 27.69 0.00 195 11 305 0 54 0 0 0 6 c)AED excursion 96 -19 Envelope loss/gain 1209 1106 74 113 12 a) Infiltration 173 46 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 1 230 Appliances/other 0 500 Subtotal(lines 6 to 13) 1382 1383 74 843 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1382 1383 74 843 15 Dud loads 35% 39% 4851 544 35% 39%1 26 331 qT.0, tal room load 1867 1927 100 1175 quired(dm) 95 86 5 52 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101ACCK Page 4 ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Bath Dining Room 2 E)posed wal I O ft 22.0 It 3 Room height 8.0 It heat/000l 8.0 ft heat/000l 4 Room dimensions 5.0 x 9.0 It 14.0 x 8.0 It 5 Room area 45.0 ft' 112.0 W Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 64 44 175 95 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 20 0 954 876 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-rlfm 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 112 82 328 179 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 30 0 1067 1291 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 45 45 62 110 112 112 154 274 F 22A-tpl 0.989 27.69 0.00 45 0 0 0 112 22 609 0 6 c)AED excursion -2 145 Envelope loss/gain 62 108 3286 2861 12 a) Infiltration 0 0 347 93 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 62 108 3633 3184 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 62 108 3633 3184 15 Dud loads 35% 39%1 22 42 35% 39%1 1275 1252 FFTotal room load 83 150 4908 4436 Airrequired(dm) 4 7 249 198 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101 Pages ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Kitchen Living Room 2 E)posed wal I O ft 14.0 ft 3 Room height 8.0 ft heat/000l 8.0 ft heat/000l 4 Room dimensions 1.0 x 216.0 ft 18.0 x 19.0 ft 5 Room area 216.0 fF 342.0 fF Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-r1fim 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 0 0 0 0 112 97 388 212 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 15 0 533 645 C 1613-19ad 0.049 1.37 2.45 216 216 296 529 342 342 469 838 F 22A-tpl 0.989 27.69 0.00 216 0 0 0 342 14 388 0 6 c)AED excursion -67 143 Envelope loss/gain 296 462 1779 1838 12 a) Infiltration 0 0 221 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 2 460 Appliances/other 2000 900 Subtotal(lines 6 to 13) 296 2922 1999 3257 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 7 13 14 Subtotal 296 2922 2007 3270 15 Dud loads 35% 39%1 104 1149 35% 39%1 704 1286 qT.0, tal room load 400 4072 2711 4556 quired(dm) 20 181 138 203 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101 Page ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Foyer Bedroom 2 2 E)posed wall 5.0 ft 20.0 It 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 5.0 x 11.0 ft ft 15.0 x 16.0 5 Room area 55.0 ft2 240.0 W Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 40 13 51 28 120 105 420 230 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 15 2 533 619 1 B-rlfm 1.130 se 31.64 24.50 7 7 215 167 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 20 20 223 211 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 40 40 160 88 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 ViV 13A-flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 55 55 75 135 240 240 329 588 F 22A-tpI 0.989 27.69 0.00 55 5 138 0 240 20 554 0 6 c)AED excursion -13 74 Envelope loss/gain 703 528 1997 1599 12 a) Infiltration 79 21 315 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 782 549 2312 2143 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 7 13 14 Subtotal 782 549 2320 2156 15 Dud loads 35% 39%1 274 216 35% 39%1 814 848 FFTotal room load 1056 764 3133 3003 Airrequired(dm) 54 34 159 134 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101ACCK Pagel ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Bedroom 4 WIC4 2 E)posed wall 28.0 It 5.0 ft 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 1.0 x 203.0 It 6.0 x 5.0 It 5 Room area 203.0 W 30.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 104 104 416 228 40 40 160 88 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-rlfm 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.19 120 105 420 230 0 0 0 0 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 15 0 533 645 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 203 203 279 497 30 30 41 74 F 22A-tpl 0.989 27.69 0.00 203 28 775 0 30 5 138 0 6 c)AED excursion 164 -4 Envelope loss/gain 2424 1764 340 157 12 a) Infiltration 441 118 79 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2865 2342 419 178 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 13 0 0 14 Subtotal 2873 2355 419 178 15 Dud loads 35% 39% 10081 926 35% 39%1 147 70 FFTotal room load 3880 3281 565 248 Air required(dm) 197 146 29 11 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101 Page ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Bathroom WIC 3 2 E)posed wal I O ft 5.0 ft 3 Room height 8.0 ft heat/000l 8.0 ft heat/000l 4 Room dimensions 1.0 x 56.0 ft 6.0 x 5.0 ft 5 Room area 56.0 ft2 30.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 40 40 160 88 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-rlfm 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 ViV 13A-flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 56 56 77 137 30 30 41 74 F 22A-tpl 0.989 27.69 0.00 56 0 0 0 30 5 138 0 6 c)AED excursion -3 -4 Envelope loss/gain 77 134 340 157 12 a) Infiltration 0 0 79 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 77 134 419 178 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 15 26 0 0 14 Subtotal 91 160 419 178 15 Dud loads 35% 39% 321 63 35% 39%1 147 70 FFTotal room load 124 222 565 248 Air required(dm) 6 10 29 11 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101 Page ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E + wrightsoft°° Right-J®Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quckcalcs@aol.com 1 Room name Bedroom 3 Hall 2 E)posed wall 27.0 It 0 ft 3 Room height 8.0 It heat/000l 8.0 ft heat/cool 4 Room dimensions 1.0 x 174.0 It 4.0 x 8.0 It 5 Room area 174.0 W 32.0 tt Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)/ 13A-4ocs 0.143 ne 4.00 2.19 96 81 324 177 0 0 0 0 I; CCI 10A-m 1.670 ne 46.76 42.95 0 0 0 0 0 0 0 0 1A-r1om 1.270 ne 35.56 43.03 15 0 533 645 0 0 0 0 V[ 13A-4ocs 0.143 se 4.00 2.19 120 120 480 263 0 0 0 0 11 1A-r1om 1.270 se 35.56 41.28 0 0 0 0 0 0 0 0 1 B-rlfm 1.130 se 31.64 24.50 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 38.29 0 0 0 0 0 0 0 0 1A-r1om 1.270 sw 35.56 39.95 0 0 0 0 0 0 0 0 13A-flocs 0.143 nw 4.00 2.19 0 0 0 0 0 0 0 0 ,A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 1.37 2.45 174 174 239 426 32 32 44 78 F 22A-tpI 0.989 27.69 0.00 174 27 748 0 32 0 0 0 6 c)AED excursion -47 -2 Envelope loss/gain 2325 1465 44 77 12 a) Infiltration 425 114 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2750 2039 44 77 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 13 -44 -77 14 Subtotal 2757 2052 0 0 15 Dud loads 35% 39% 9671 807 35% 39%1 0 0 Total room load 3725 2858 0 100 T.0, quired(dm) 189127 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-May-0518:46:35 Right-Sute@ Universal 201919.0.21 RSU08101 Page 10 ..ts\Wri htsoftHVAC\MelissaModelll-MASTER.rup Calc=MJ8 Front Door faces: E Duct stem Summary Job: +� wrightsoft D System Date: Entire House By: Quick Calcs, Inc. 317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com Project Information For: Melissa Model II Port St.Lucie,FL 34983 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.248 in/100ft 0.248 in/100ft Actual airflow 1500 cfm 1500 cfm Total effective length(TEL) 202 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath c 150 4 7 0.403 4.0 Ox 0 Wx 9.0 115.0 st3 Bathroom c 222 6 10 0.254 4.0 Ox 0 Wx 41.9 155.0 st5 Bedroom 2 h 3133 159 134 0.386 8.0 Ox 0 Wx 14.7 115.0 st1 Bedroom 3 h 2858 189 127 0 0 Ox 0 Wx 0 0 Bedroom 4 h 3880 197 146 0.254 8.0 Ox 0 Wx 41.6 155.0 st5 Dining Room h 4908 249 198 0.294 9.0 Ox 0 Wx 35.1 135.0 st7 Foyer h 1056 54 34 0.384 5.0 Ox0 VI Fx 15.3 115.0 st1 Kitchen-A c 4072 20 181 0.304 8.0 Ox0 VI Fx 29.7 135.0 st7 Laundry c 1175 5 52 0.402 5.0 Ox0 VI Fx 9.4 115.0 st3 Living Room-A c 4556 138 203 0.297 8.0 Ox 0 VI Fx 33.2 135.0 st7 Master Bath h 1867 95 86 0.369 6.0 Ox 0 VI Fx 20.6 115.0 st2 Master Bedroom-A c 5781 254 257 0.333 9.0 Ox 0 VI Fx 35.0 115.0 st2 Pantry c 40 1 2 0.390 4.0 Ox 0 Wx 13.0 115.0 st3 Toilet h 623 32 21 0.359 4.0 Ox 0 Wx 24.4 115.0 st2 WIC 1 h 678 34 13 0.350 4.0 Ox 0 Wx 27.8 115.0 st2 WIC 2 c 157 4 7 0.353 4.0 Ox 0 Wx 26.6 115.0 st2 WIC 3 h 565 29 11 0.295 4.0 Ox 0 Wx 34.7 135.0 st4 WIN h 565 29 11 0.248 4.0 Ox 0 Wx 46.8 155.0 st5 wrightsoft® 2021-May-0518:46:36 A= AMA=ek=Iae,-"e-h-,1-p-, Right-Sute®Urrversal201919.0.21RSU08101 Pagel ACCA ...ts\WrightsoftHVAC\Melissa Model ll-MASTER.rup Calc=MJ8 Front Door faces: E SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st5 PeakAVF 232 167 0.248 525 9.0 0 x 0 VinlFlx st4 st4 PeakAVF 261 178 0.248 591 9.0 0 x 0 VinlFlx st1 st1 PeakAVF 474 346 0.248 443 14.0 0 x 0 VinlFlx st7 PeakAVF 407 582 0.294 544 14.0 0 x 0 VinlFlx st3 st3 PeakAVF 418 642 0.294 601 14.0 0 x 0 VinIFIX st2 PeakAVF 419 384 0.333 534 12.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 1500 1500 0 0 0 0 Ox 0 VIFx wrightsoft® 2021-May-0518:46:36 A —=ek=Iae,•.-.—aw,1—p". Right-Sute®Urrversal 2019 19.0.21 RSU08101 Page 2 ACCA ...tswrightsoftHVAC\Melissa Model ll-MASTER.rup Calc=MJ8 Front Door faces: E