Loading...
HomeMy WebLinkAbout008 HVAC Energy & Manual Js(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Feketa Residence Builder Name: Street: 3401 Sneed Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34945 Permit Number: Owner: Feketa Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1168.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1168.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Types (1276.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1276.00 ft2 6. Conditioned floor area above grade (ft2) 1276 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(141.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Hall, AH: Utility R ft2 6 70 a. U-Factor: Sgl, U=0.28 141.00 ft2 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 25.4 SEER:17.30 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 5.404 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.220 a. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1276.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1276.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.111 Total Proposed Modified Loads: 38.65 PASS Total Baseline Loads: 41.74 1 hereby certify that the plans and specifications covered by Review of the plans and *tj4E Sr4p this calculation are in compliance with the Florida Energy specifications covered by this,�+4r� _ 0, Code. calculation indicates compliance 1lt with the Florida Energy Code. PREPARED BY: Before construction is completed= DATE: 7-22-2021 this building will be inspected for compliance with Section 553.908 0 I hereby certify that this building, as designed, is in compliance Florida Statutes. S� with the Florida Energy Code. aD OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/22/2021 11:49 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Feketa Residence Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1276 Lot # Owner Name: Feketa Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3401 Sneed Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34945 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1276 10208 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 1 195 1560 No 2 1 1 Yes Yes Yes 2 Bath 1 81 648 No 2 1 Yes Yes Yes 3 WIC 1 54 432 No 1 1 No Yes Yes 4 Hall 88 704 No 0 1 Yes Yes Yes 5 Bedroom 2 182 1456 No 2 1 1 Yes Yes Yes 6 WIC 2 26 208 No 1 1 Yes Yes Yes 7 Bath 2 40 320 No 1 1 No Yes Yes 8 Utility 91 728 No 1 1 Yes Yes Yes 9 Kitchen 196 1568 Yes 2 1 Yes Yes Yes 10 Living Room 323 2584 No 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 1 28 ft 195 ftz ---- 1 0 0 2 Slab -On -Grade Edge Insulatio Bath 1 9 ft 81 ftz ---- 1 0 0 3 Slab -On -Grade Edge Insulatio WIC 1 1 ft 54 ftz ---- 1 0 0 4 Slab -On -Grade Edge Insulatio Hall 4 ft 88 ftz ---- 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 2 27 ft 182 ftz ---- 1 0 0 6 Slab -On -Grade Edge Insulatio WIC 2 6 ft 26 ftz ---- 1 0 0 7 Slab -On -Grade Edge Insulatio Bath 2 1 ft 40 ftz ---- 1 0 0 7/22/2021 11:49 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio Utility 7 ft 91 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio Kitchen 29 ft 196 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Living Room 36 ft 323 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1345 ft2 0 ft2 Medium N 0.6 No 0.9 No 20 18.43 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1276 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Bedroom 1 0 Blown 195 ft2 0.1 Wood 2 Under Attic (Unvented) Bath 1 0 Blown 81 ft2 0.1 Wood 3 Under Attic (Unvented) WIC 1 0 Blown 54 ft2 0.1 Wood 4 Under Attic (Unvented) Hall 0 Blown 88 ft2 0.1 Wood 5 Under Attic (Unvented) Bedroom 2 0 Blown 182 ft2 0.1 Wood 6 Under Attic (Unvented) WIC 2 0 Blown 26 ft2 0.1 Wood 7 Under Attic (Unvented) Bath 2 0 Blown 40 ft2 0.1 Wood 8 Under Attic (Unvented) Utility 0 Blown 91 ft2 0.1 Wood 9 Under Attic (Unvented) Kitchen 0 Blown 196 ft2 0.1 Wood 10 Under Attic (Unvented) Living Room 0 Blown 323 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - Int InsuBedroom 1 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Int InsuBedroom 1 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Int Insul Bath 1 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Int Insul Hall 4.1 4 0 8 0 32.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block - Int InsuBedroom 2 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 6 S Exterior Concrete Block - Int InsuBedroom 2 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 7 S Exterior Concrete Block - Int Insul WIC 2 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Int Insul WIC 2 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Int Insul Utility 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 10 E Exterior Concrete Block - Int Insul Kitchen 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 11 S Exterior Concrete Block - Int Insul Kitchen 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Int Insul Kitchen 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 7/22/2021 11:49 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS It Ornt Adjacent To XNAI T)Ipp Space Cavity Width Height Sheathing Framing Solar Below 13 N 14 W Exterior Concrete Block - Int InsLUiving Room 4.1 17 0 8 0 Exterior Concrete Block - Int InsLUiving Room 4.1 19 0 8 0 136.0 ft2 0 152.0 ft2 0 0 0.6 0 0.6 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 2 S W Insulated Insulated Utility None .39 Living Room None .39 2 10 3 6 10 6 10 19.4 ft2 20.5 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 2 3 4 5 6 7 E 2 Vinyl N 3 Vinyl E 5 Vinyl S 11 Vinyl W 12 Vinyl N 13 Vinyl W 14 Vinyl Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes 0.28 0.22 Y 30.0 ft2 Yes 0.28 0.22 Y 6.0 ft2 Yes 0.28 0.22 Y 30.0 ft2 Yes 0.28 0.22 Y 12.0 ft2 Yes 0.28 0.22 Y 15.0 ft2 Yes 0.28 0.22 Y 24.0 ft2 Yes 0.28 0.22 Y 24.0 ft2 10 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 10 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in None None None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1190.9 65.34 122.67 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 17.325.4 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Utility 0.95 50 gal 60.9 gal 120 deg None 7/22/2021 11:49 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 70 ft2 Hall 15 ft2 Default Leakage Utility (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar A r May X Jun X Jul X Auge Oct Nov Dec HeatinJan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 1 Default(8lbs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Utility Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Living Room 7/22/2021 11:49 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows„ Description a. U-Factor: Sgl, U=0.28 SHGC: SHGC=0.22 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 3401 Sneed Road, Fort Pierce, FL, 34945 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1168.00 ft2 b. N/A R= ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area No a. Roof Deck (Unvented) R=20.0 1276.00 ft2 1276 b. N/A R= ft2 c. N/A R= ft2 Area 12. Ducts, location & insulation level R ft2 141.00 ft2 a. Sup: Attic, Ret: Hall, AH: Utility 6 70 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 25.4 SEER:17.30 ft2 5.404 ft. 0.220 Area ft2 Insulation Area R=0.0 1276.00 ft2 R= ft2 R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 17.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF. Pstat .IV0 5 g 0 yll �' 7f111t�i•'r. '; •a .+`�i tip`. �l Q h WIE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/22/2021 11:50 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Feketa Residence Builder Name: Street: 3401 Sneed Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34945 Permit Number: Y U Owner: Feketa Residence Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and an gaps in the air barrier shall be sealed. Y 9 p shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind p'p*na and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cellinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 7/22/2021 11:50 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 rightsoft Project Summary Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com For: Feketa Residence 3401 Sneed Road, Fort Pierce, FL 34945 Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 16362 Btuh Ducts 2231 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 18593 Btuh Simplified Average 0 Heating Cooling Area (ft2) 1276 1276 Volume (ft3) 10208 10208 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 77 39 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.4 kW 18376 Btuh 20 °F 847 cfm 0.046 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 15836 Btuh Ducts 1519 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 16488 Btuh Latent Cooling Equipment Load Sizing Structure 4635 Btuh Ducts 1177 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5811 Btuh Equipment Total Load (Sen+Lat) 22299 Btuh Req. total capacity at 0.70 SHR 2.0 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR7024A1 Coil TAM9AOA24V21 AHRI ref 10230600 Efficiency 12.5 EER, 17.3 SEER Sensible cooling 17780 Btuh Latent cooling 7620 Btuh Total cooling 25400 Btuh Actual air flow 847 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rk- rightsnf#- 2021-Jul-2211:58:41 RightSuiteO Universal 2019 19.0.21 RSU08101 Page 1 •' ...\Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W +}+ wrightsoft- Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House Bedroom 1 2 Exposed wall 146.0 ft 28.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 15.0 x 13.0 ft 5 Room area 1276.0 f? 195.0 f? Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft"F (Btuh/ft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T�13A-4ocs 0.143 n 4.00 2.19 312 282 1129 617 104 104 416 228 1A-rlov 0.900 n 25.20 19.79 6 0 151 119 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 24 0 605 475 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 272 212 849 464 120 90 360 197 11 1A-rlov 0.900 a 25.20 19.79 60 120 1512 1187 30 30 756 594 VL-D 13A-4ocs 0.143 s 4.00 2.19 312 281 1124 614 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 12 24 302 237 0 0 0 0 11 DO 0.390 s 10.92 10.34 19 19 210 199 0 0 0 0 VL1A-rl ocs 0.900 w 4.20 272 213 851 465 0 0 0 0 1A-rlov 0.900 w 25.20 0.30 40.30 24 4 605 967 0 0 0 0 1A-rlov 0.900 w 25.20 40.70 15 2 378 611 0 0 0 0 D 11 DO 0.390 w 10.92 10.34 20 20 223 211 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 1276 1276 2023 1746 195 195 309 267 F 22A-tol 0.989 27.69 0.00 1276 146 4043 0 195 28 775 0 61 c) AED excursion 4291 1 121 Envelope loss/gain i 14006 8341 i 1 2617 1264 12 a) Infiltration 2356 645 452 124 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 15 3450 2 460 Appliances/other 3400 0 Subtotal (lines 6 to 13) 16362 15836 3069 1847 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 120 56 14 Subtotal 16362 15836 3189 1903 15 Duct loads 14 % 10 % 2231 1519 14 % 10 % 435 183 Total room load 185931 173551 3624 2086 Air required (cfm) 8471 8471 165 102 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■ �gntsort 2021-Jul-22 11:58:42 Right-Suite(g) Universal 2019 19.0.21 RSU08101AfSl Page 1 \Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W +}+ wrightsoft- Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 1 WIC 1 2 Exposed wall 9.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 9.0 ft 6.0 x 9.0 ft 5 Room area 81.0 f? 54.0 f? Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btuh/ft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T�13A-4ocs 0.143 n 4.00 2.19 72 66 264 144 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 6 0 151 119 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 VL-D 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 11 DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 VL1A-rl ocs 0.900 w 4.20 0 0 0 0 0 0 0 0 1A-rlov 0.900 w 25.20 0.30 40.30 0 0 0 0 0 0 0 0 1A-rlov 0.900 w 25.20 40.70 0 0 0 0 0 0 0 0 D 11 DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 81 81 128 111 54 54 86 74 F 22A-tol 0.989 27.69 0.00 81 9 249 0 54 0 0 0 61 c) AED excursion 1 -1101 1 1 1 -3 Envelope loss/gain 793 364 86 70 12 a) Infiltration 145 40 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 938 864 86 300 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 83 39 14 Subtotal 938 864 169 339 15 Duct loads 14 % 10 % 128 83 14 % 10 % 23 33 Total room load 1066 947 192 371 Air required (cfm) 49 46 1 1 9 18 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■ �gntsort 2021-Jul-22 11:58:42 RightSuiteOUniversal 2019 19.0.21 RSU08101AfSl Paget \Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W +}+ wrightsoft- Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Hall Bedroom 2 2 Exposed wall 4.0 ft 27.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 4.0 x 22.0 ft 14.0 x 13.0 ft 5 Room area 88.0 f? 182.0 f? Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'°F (Btuh/ft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T�13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 Vy L-G 13A-4ocs 0.143 e 4.00 2.19 32 32 128 70 112 82 328 179 11 1A-rlov 0.900 a 25.20 19.79 0 0 0 0 30 30 756 594 VL-D 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 104 104 416 228 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 11 DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 VL1A-rl ocs 0.900 w 4.20 0 0 0 0 0 0 0 0 1A-rlov 0.900 w 25.20 0.30 40.30 0 0 0 0 0 0 0 0 1A-rlov 0.900 w 25.20 40.70 0 0 0 0 0 0 0 0 D 11 DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 88 88 140 120 182 182 289 249 F 22A-tol 0.989 27.69 0.00 88 4 111 0 182 27 748 0 61 c) AED excursion 1 -21 1 1 1 -21 Envelope loss/gain 378 188 2537 1229 12 a) Infiltration 65 18 436 119 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 443 206 2973 1808 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -443 -206 120 56 14 Subtotal 0 0 3093 1864 15 Duct loads 14 % 10 % 0 0 14 % 10 % 422 179 Total room load 0 0 3514 2043 Air required (cfm) 0 0 1 1 160 100 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■ �gntsort 2021-Jul-22 11:58:42 RightSuiteOUniversal 2019 19.0.21 RSU08101AfSl Page \Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W +}+ wrightsoft- Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name WIC 2 Bath 2 2 Exposed wall 6.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 26.0 ft 8.0 x 5.0 ft 5 Room area 26.0 f? 40.0 f? Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft"F (Btuh/ft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T�13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 VL-D 13A-4ocs 0.143 s 4.00 2.19 40 40 160 88 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 0 0 0 0 11 DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 VL1A-rl ocs 0.900 w 4.20 8 8 32 18 0 0 0 0 1A-rlov 0.900 w 25.20 0.30 40.30 0 0 0 0 0 0 0 0 1A-rlov 0.900 w 25.20 40.70 0 0 0 0 0 0 0 0 D 11 DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 26 26 41 36 40 40 63 55 F 22A-tol 0.989 27.69 0.00 26 6 166 0 40 0 0 0 61 c) AED excursion 1 -51 1 1 1 -3 Envelope loss/gain 400i 136 1 1 63 51 12 a) Infiltration 97 27 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 496 393 63 281 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 46 21 14 Subtotal 496 393 110 303 15 Duct loads 14 % 10 % 68 38 14 % 10 % 15 29 Total room load 564 430 125 332 Air required (cfm) 26 21 1 1 6 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■ �gntsort 2021-Jul-22 11:58:42 RightSuiteOUniversal 2019 19.0.21 RSU08101AfSl Page \Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W +}+ wrightsoft- Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Utility Kitchen 2 Exposed wall 7.0 ft 29.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 13.0 x 7.0 ft 14.0 x 14.0 ft 5 Room area 91.0 f? 196.0 f? Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft"F (Btuh/ft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T�13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 8 8 32 18 11 1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0 VL-D 13A-4ocs 0.143 s 4.00 2.19 56 37 147 80 112 100 400 219 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 12 12 302 237 11 DO 0.390 s 10.92 10.34 19 19 210 199 0 0 0 0 VL1A-rl ocs 0.900 w 4.20 0 0 0 0 112 97 380 212 1A-rlov 0.900 w 25.20 0.30 40.30 0 0 0 0 0 0 0 0 1A-rlov 0.900 w 25.20 40.70 0 0 0 0 15 1 378 611 D 11 DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 91 91 144 125 196 196 311 268 F 22A-tol 0.989 I 27.69 I 0.00 I 91 I 7 I 194 I 0 I 196 29 I 803 I 0 61 c) AED excursion I I I I -13 I I 1 188 Envelope loss/gain 696 391 2615 1753 12 a) Infiltration 113 31 468 128 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 2 460 Appliances/other 500 2000 Subtotal (lines 6 to 13) 809 1152 3083 4341 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 37 17 0 0 14 Subtotal 845 1169 3083 4341 15 Duct loads 14 % 10 % 115 112 14 % 10 % 420 416 Total room load 961 1281 3503 4757 Air required (cfm) 44 63 1 1 160 232 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �}� w■ �gntsort 2021-Jul-22 11:58:42 RightSuiteOUniversal 2019 19.0.21 RSU08101AfSl Pages \Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W wrlghtsoW Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Living Room 2 Exposed wall 36.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 19.0 x 17.0 ft 5 Room area 323.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuhu °F (Btuhlft') or perimeter (ft) (Btuh) or perimeter Heat Cool Gross I N/P/S j Heat I Cool j Gross N/P/S j Heat Cool 6 V 13A-4ocs 0.143 n 4.00 2.19 136 112 448 245 1A-rlov 0.900 n 25.20 19.79 0 0 0 0 1A-rlov 0.900 n 25.20 19.79 24 0 605 475 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 11 1A-rlov 0.900 a 25.20 19.79 0 0 0 0 VL-D 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 1A-rlov 0.900 s 25.20 19.79 0 0 0 0 11 DO 0.390 s 10.92 10.34 0 0 0 0 Vy 1A-rlocs 0.900 w 4.20 124 102 431 235 1A-rlov 0.900 w 25.20 0.30 40.30 24 2 605 967 I��,G"' 1A-rlov 0.900 w 25.20 40.70 0 0 0 0 D 11 DO 0.390 w 10.92 10.34 20 20 223 211 C 16X19-0md 0.408 1.59 1.37 323 323 512 442 F 22A-tol 0.989 27.69 0.00 323 36 997 0 61 c) AED excursion 1 320 Envelope loss/gain 3821 2896 12 a) Infiltration 581 159 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 3 690 Appliances/other 900 Subtotal (lines 6 to 13) 4402 4645 Less external load 0 0 Less transfer 0 0 Redistribution 37 17 14 Subtotal 4439 4662 15 Duct loads 14% 10% 605 447 Total room load 5044 5109 Air required (cfm) 230 249 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -FW w�MWW%2sart- 2021-Jul-2211:58:42 Aft RightSuite@Universal 2019 19.0.21 RSU08101 Page \Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W rightsoft Duct System Summary Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com For: Feketa Residence 3401 Sneed Road, Fort Pierce, FL 34945 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.368 in/100ft 847 cfm 136 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.368 in/100ft 847 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 1 h 1066 49 46 0.368 5.0 Ox 0 VIFx 20.8 115.0 st3 Bath 2 c 332 6 16 0.404 4.0 Ox 0 VIFx 8.6 115.0 SO Bedroom 1 h 3624 165 102 0.378 8.0 Ox 0 VIFx 17.2 115.0 st3 Bedroom 2 h 3514 160 100 0.389 7.0 Ox 0 VIFx 13.7 115.0 SO Kitchen c 4757 160 232 0.391 8.0 Ox 0 VIFx 13.0 115.0 st2 Living Room c 2555 115 125 0.375 7.0 Ox 0 VIFx 18.2 115.0 st2 Living Room -A c 2555 115 125 0.400 7.0 Ox 0 VIFx 10.0 115.0 st2 Utility c 1281 44 63 0.402 6.0 Ox 0 VIFx 9.2 115.0 st1 Wlc 1 c 371 9 18 0.378 4.0 Ox 0 VIFx 17.2 115.0 st3 WIC 2 h 564 26 21 0.395 4.0 Ox 0 VIFx 11.5 115.0 SO Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk SO Peak AVF 235 199 0.389 532 9.0 0 x 0 VinlFlx st3 Peak AVF 222 166 0.368 503 9.0 0 x 0 VinlFlx st2 Peak AVF 389 482 0.375 613 12.0 0 x 0 VinlFlx * wrightsof#' . .. RightSuiteOUniversal 2019 19.0.21 RSU08101 ...\Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W WYA15111IMPAIMMEN Page 1 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 847 847 0 0 0 0 Ox 0 VIFx * wrigh#sOf#' . .. RightSuiteOUniversal 2019 19.0.21 RSU08101 ...\Documents\Wrightsoft HVAC\Feketa Residence.rup Calc = MJ8 Front Door faces: W KIYA115111IMPAIMMEN Page 2