Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEReviewed for Code Compliance Universal Engineering FORM R405-2020 99 Sciences FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PALLAS RENOVATION Builder Name: Street: 2504 KERR STREET Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number:, Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 10. Wall Types(1360.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=5.0 1272.00 ft2 b. Frame - Wood, Exterior R=19.0 88.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms (Bedrms In Addition) 3(0) d. N/A R= ftz 11. Ceiling Types (1459.0 sgfL) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=19.0 1393.00 ft2 6. Conditioned floor area above grade (ft2) 1459 b. Roof Deck (Unvented) R=19.0 66.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(220.4 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST R ft2 6 125 a U-Factor. Sgl, U=0.65 220.42 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 13. Coding systems kBkdhr Efficiency SHGC: a. Central Unit 18.0 SEER:16.00 c. U-Factor: N/A ft2 b. Central Unit 24.0 SEER:18.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 1 17.0 COP;.00 OP:.50 b. Electric Heat Pump 17HS 8. Skylights Area c. U-Factor.(AVG) N/A ft2 15. Hot water systems - SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1459.0 sgfL) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1459.00 ft2 b. Conservation features b. N/A R= ft2 None c. WA R= ft2 16. Credits None Glass/Floor Area: 0.151 Total Proposed Modified Loads: 36.57 PASS Total Baseline Loads: 48.07 I hereby certify that the plans and specifications covered by Review of the plans and -ViE ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this O y a -; Off, Code. calculation indicates compliance '-ifN,ii''0 \�. k&EaQ with the Florida Energy Code. ti lurr''%. =~.•''.�` ,� O PREPARED BY: DATE: 7-22-2021 Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy o . OWNER/A ENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure quen as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection. Checklist In accordance with R402.4.1.1 andQ project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 7/21/2021 6:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY GFIEGKLI5T REPORT PROJECT Title: PALLAS RENOVATION Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1459 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 2504 KERR STREET Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: Addition Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 %. Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 AHU 833 6664 2 MINI SPLIT 626 5008 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Coded Heated 1 UTILITY 66 528 No 0 1 Yes Yes Yes 2 NOOK 121 968 No 0 1 No Yes Yes 3 BEDROOM 3 133 1064 No 0 1 1 Yes Yes Yes 4 CLST 3 12 96 No 0 1 Yes Yes Yes 5 AHU CLST 10 80 No 0 1 No Yes Yes 6 CLST 2 12 96 No 0 1 Yes Yes Yes 7 HALLWAY 25 200 No 0 1 No Yes Yes 8 BEDROOM 2 140 1120 No 0 1 1 Yes Yes Yes 9 BATH 2 40 320 No 0 1 Yes Yes Yes 10 DINING RM 144 1152 No 0 1 Yes Yes Yes 11 KITCHEN 130 1040 Yes 0 1 Yes Yes Yes 12 MASTER BEDROO 240 1920 No 0 1 1 Yes Yes Yes 13 M WIC 30 240 No 0 1 Yes Yes Yes 14 M BATH 60 480 No 0 1 Yes Yes Yes 15 LIVING RM 296 2368 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation UTILITY lift 66 ft2 1 0 0 2 Slab -On -Grade Edge Insulation NOOK 1 ft 121 ft' 1 0 0 7/21/2021 6:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulation BEDROOM 3 22 ft 133 ftz a 1 0 0 4 Slab -On -Grade Edge Insulation CLST 3 2 ft 12 ftz 1 0 0 5 Slab -On -Grade Edge Insulation AHU CLST 1 ft 10 ftz 1 0 0 6 Slab -On -Grade Edge Insulation CLST 2 2 ft 12 ftz 1 0 0 7 Slab -On -Grade Edge Insulation HALLWAY 1 ft 25 ftz 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 2 22 ft 140 ftz 1 0 0 9 Slab -On -Grade Edge Insulation BATH 2 5 ft 40 ftz 1 0 0 10SIab-On-Grade Edge Insulation DINING RM loft 144 ftz 1 0 0 11SIab-On-Grade Edge Insulation KITCHEN 5ft 130 ft' 1 0 0 12SIab-On-Grade Edge Insulation MASTER BEDRO 31 ft 240 ftz --- 1 0 0 13SIab-On-Grade Edge Insulation M W IC lift 30 ftz 1 0 0 14SIab-On-Grade Edge Insulation M BATH loft 60 ftz __ 1 0 0 15SIab-On-Grade Edge Insulation LIVING RM 39 ft 296 ftz r 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Flat Gravel 1464 ftz 60 ftz Medium N 0.3 No 0.9 No 19 4.76 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Unvented 0 1459 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) UTILITY 30 Blown 66 ftz 0.1 Wood 2 Under Attic (Unvented) NOOK 0 Blown 121112 0.11 Wood 3 Under Attic (Unvented) BEDROOM 3 0 Blown 133 ftz 0.1 Wood 4 Under Attic (Unvented) CLST 3 0 Blown 12 ftz 0.1 Wood 5 Under Attic (Unvented) AHU CLST 0 Blown 10 ftz 0.1 Wood 6 Under Attic (Unvented) CLST 2 0 Blown 12 ftz 0.1 Wood 7 Under Attic (Unvented) HALLWAY 0 Blown 25 ftz 0.1 Wood 8 Under Attic (Unvented) BEDROOM 2 0 Blown, 140 ftz 0.1 Wood 9 Under Attic (Unvented) BATH 2 0 Blown 40 ftz 0.1 Wood 10 Under Attic (Unvented) DINING RM 0 Blown 144 ftz 0.1 Wood 11 Under Attic (Unvented) KITCHEN 0 Blown 130 ftz 0.1 Wood 12 Under Attic-(Unvented) MASTER BEDRO 0 Blown 240 ftz 0.1 Wood 13 Under Attic (Unvented) M WIC 0 Blown 30 ftz 0.1 Wood 14 Under Attic (Unvented) M BATH 0 Blown 60 ftz 0.1 Wood 15 Under Attic (Unvented) LIVING RM 0 Blown 296 ftz 0.1 Wood i12021 6:02 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition 2020 Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Frame -Wood UTILITY 19 11 0 8 0 88.0 ft2 0 0.1 0.3 0 2 E Exterior Concrete Block - Int InsuBEDROOM 3 5 11 0 8 0 88.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Int InsuBEDROOM 3 5 11 0 8 0 88.0 f12 0 0 0.3 0 4 S Exterior Concrete Block - Int Insul CLST 3 5 2 0 8 0 16.0 ft2 0 0 0.3 0 5 W Exterior Concrete Block - Int Insul CLST 2 5 2 0 8 0 16.0 ft2 0 0 0.3 0 6 S Exterior Concrete Block - Int InsuBEDROOM 2 5 10 0 8 0 80.0 ft2 0 0 0.3 0 _ 7 W Exterior Concrete Block - Int InsuBEDROOM 2 5 12 0 8 0 96.0 ft2 0 0 0.3 0 8 E Exterior Concrete Block - Int Insul BATH 2 5 5 0 8 0 40.0 ft2 0 0 0.3 0 9 S Exterior Concrete Block- Int InsulDINING RM 5 4 0 8 0 32.0 ft2 0 0 0.3 0 _ 10 W Exterior Concrete Block - Int InsulDINING RM 5 6 0 ( 8 0 48.0 ft2 0 0 0.3 0 11 E Exterior Concrete Block - Int Insul KITCHEN 5 5 0 8 0 40.0 ft2 0 0 0.3 0 12 N Exterior Concrete Block - Int InsuMASTER BE 5 15 0 8 0 120.0 ft2 0 0 0.3 0 _ 13 E Exterior Concrete Block - Int InsuMASTER BE 5 16 0 8 0 128.0 ft2 0 0 0.3 0 14 E Exterior Concrete Block- Int Insul M W IC 5 6 0 8 0 48.0 ft2 0 0 0.3 0 _ 15 S Exterior Concrete Block - Int Insul M W IC 5 5 0 8 0 40.0 ft2 0 0 0.3 0 _ 16 S Exterior Concrete Block - Int Insul M BATH 5 10 0 8 0 80.0 ft2 0 0 0.3 0 17 N Exterior 'Concrete Block - Int Insul LIVING RM 5 16 0 8 0 126.0 ft2 0 0 0.3 0 18 W Exterior Concrete Block - Int Insul LIVING RM 5 23 0 8 0 184.0 ft2 0 0 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated UTILITY None .23 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 it 0 in 1 ft4 in None None 2 W 7 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft0 in 1 ft 4 In None None 3 E 8 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft0 in 1 ft4 in None None 4 E 11 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 N 12 Metal Low-E Single Yes 0.65 0.25 Y 20.4 ft2 2 ft 0 in 1 ft 4 in None None 6 E 13 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 In None None 7 E 13 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft0 in 1 ft 4 in None None 8 N 17 Metal Low-E Single Yes 0.65 0.25 Y 40.0 ft2 2 ft0 in 1 ft 4 in None None 9 W 18 Metal Low-E Single Yes 0.65 0.25 Y 40.0 ft2 2 ft 0 in 1 ft 4 in None None 10 W 18 Metal Low-E Single Yes 0.65 0.26 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None 7/21/2021 6:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 972.7 53.36 100.18 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ 2 Electric Heat Pump/Existing/co None Split COP:1 17 kBtu/hr Single HSPF:12.5 17 kBtu/hr 1 2 sys#1 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Replacement for w 2 Central Unit/EAsting/confirmed Split Split Single SEER: 16 18 kBtu/hr 540 cfm 0.8 Single SEER: 18 24 kBtu/hr 720 cfm 0.8 1 2 sys#1 Ductless HOT WATER.SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — v # Location R-Value Area — Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 125 ftz Attic 13 ft' Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Cooling Jan Feb Mar HeatingJan Feb Mar VentinJan Feb Mar Ceiling Fans: Apr M Jun Jul AugSe Oct Apr May Jun Jul Auge Oct Apr May Jun Jul Aug Sep Oct Nov Nov Nov Dec Dec Dec 7/21/2021 6:02 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 UTILITY Default(8 Ibs/sq.ft. ft2 ft 0.3 NOOK Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8lbs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/s.ft. ft2 ft 0.3 LIVING RM 7/21/2021 6:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 76 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows** Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor. N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 2504 KERR STREET, FORT PIERCE, FL, Addition Detached 1 3(0) No 1459 Area 220.42 ft2 ft2 ft2 ft2 2.000 ft. 0.250 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1459.00 1`12 b. N/A R= ft2 c. N/A R= ft2 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Exterior c. N/A d. N/A 11. Ceiling Type and insulation level a. Roof -Deck (Unvented) b. Roof Deck (Unvented) c. N/A 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: AHU CLST 13. Cooling systems a. Central Unit b. Central Unit 14. Heating systems a. Electric Strip Heat b. Electric Heat Pump 15. Hot water systems - a. Electric b. Conservation features None Credits (Performance method) Insulation R=5.0 R=19.0 R= R= Insulation R=19.0 R=19.0 R= Area 1272.00 ft2 88.00 ft2 ft2 ft2 Area 1393.00 ft2 66.00 ft2 ft2 R ft2 6 125 kBtu/hr Efficiency 18.0 SEER:16.00 24.0 SEER:18.00 kBtu/hr Efficiency 17.0 COP:1.00 17.0 HSPF:12.50 Cap: 50 gallons EF: 0.98 None I certify that this home has complied with the Florida Energy Efficiency Code for Building -,Till, S Construction through the above energy saving features which will be installed (or exceeded) ox in this home before final inspection.- Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: ALADate:7 'k �, a Address of New Home: City/FL Zip: e" �; y'< COD WE t� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/21/2021 6:03 PM EnergyGauge@) USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PALLAS RENOVATION Builder Name: Street: 2504 KERR STREET Permit Office: ST LUCIE COUNTY City, State, Zip: FORT -PIERCE, FL, Permit Number: U Owner. Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce (3 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit lit shall be aligned with the J Ceiling/attic insulation and any gaps In the air barrier shall be sealed. The insulation in any dropped ceiling/sofft shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction 4 the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed wails shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be Installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall. be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind vinina and wiri Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or. ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Qlates and walls or ceilin s a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 7/21/2021 6:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1