HomeMy WebLinkAboutProject Information-�- wrightsofto Pro Summary QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For. PALLAS RENOVATION 2504 KERR STREET, FORT PIERCE, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: Jul 22, 2021 By: Reviewed for Code Compliance 93 Universal Engineering Sciences Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 9200 Btuh Ducts 2135 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 11334 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area ft Z 33 8 3 Volume (ft3) 6472 6472 Air changes/hour 0.37 0.19 Equiv. AVF (cfm) 40 20 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 3.0 kW 10308 Btuh 600 0 cfm 0.053 cfm/Btuh 1.00 in H2O 90 OF 75 OF 15 OF M 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 10305 Btuh Ducts 3216 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier Equipment sensible load n 0.95 12845 Btuh Latent Cooling Equipment Load Sizing Structure, 2354 Btuh Ducts 854 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3208 Btuh Equipment Total Load (Sen+Lat) 16053 Btuh Req. total capacity at 0.70 SHR 1.5 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX16S181A Coil ASPT291314A AHRI ref 201786257 Efficiency 13.0 EER, 16 SEER Sensible cooling 12600 Btuh Latent cooling 5400 Btuh Total cooling 18000 Btuh Actual air flow 600 cfm Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -*- wrights41ft. 2021-Jul-23 08:07:03 ��^M RlghtSuite® Universal 2021 21.0.02 RSU08101 Page 1 E:IDocumnets%Wrightsoft WACIPALLAS RENOVATION.rup Calc = MJ8 Front Door faces: W -�d- wrightsoft, Project Summary MINI SPLIT QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emall: QUICKCALCS AOL.COM For PALLAS RENOVATION 2504 KERR STREET, FORT PIERCE, FL Notes: Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 10824 Btuh Ducts 2206 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 13030 Btuh Infiltration Fort Pierce, FL, US Job: Date: Jul 22, 2021 By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr/Ib Sensible Cooling Equipment Load Sizing Structure 14724 Btuh Ducts 3235 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipmenf sensible load 17061 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3284 Btuh Ducts 847 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 626 626 Equipment latent load 4131 Btuh Volume (W) 5008 5008 Air changes/hour 0.55 0.28 Equipment Total Load (Sen+Lat) 21192 Btuh Equiv. AVF (cfm) 46 24 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Make Daikin Trade DAIKIN Model 3MXS24RMVJUA AHRI ref 205663356 Efficiency Heating input Heating output • Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 26 OF Backup: 12.5 HSPF 24000 Btuh @ 470F 27 a 800 cfm 0.061 cfm/Btuh 1.00 in H2O Input = 3 kW, Output = 11680 Btuh, 100 AFUE Cooling Equipment Summary Make Daikin Trade DAIKIN Cond 3MXS24RMVJUA Coil FTS12LVJU, FTS12LVJU AHRI ref 205663356 Efficiency 12.7 EER, 16 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2021-Jul-23 08:07:03 "" RlghtSulte® Universal 2021 21.0.02 RSU08101 Page 2 E:\Documnets\Wrightson WAMPALLAS RENOVA7ION.rup Calc = MJ8 Front Door faces: W + wrightsoft Right4@ Worksheet AHU QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Enall: QUICKCALCS AOL.COM Job: Date: Jul 22, 2021 By- 1 Room name AHU UTILITY 2 3 Exposed wall Room height 79.0 ft 8.0 ft 11.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 809.0 ft2 6.0 x 11.0 ft 66.0 ft2 Ty Construction number U-value (Btuh/ftMF) Or HTM (Btuh/ft2) Area -) or perimeter (ft) Load (Stuh) wiper meter (ft) Load (Btuh) Heat Cod Gross NIP/S Heat Cod Gross N/P/S Heat Cod 6 - 13A5ocs 2 glazing, dr low-e 2 glazing, dr low- 6.125 0.650 0.650 n n n 3 50 0.00 0.00 1.91 0.00 0.00' 98 0 0 68 0 - - 0 238 0 - 0 130 0 0 88 0 -0 6B 0 0 238 0 0 130 0 0 11 11D0 13ASacs 0.390 0.125 n a . . _ 10.92 3.50 10.34 1.91 _ . 20 168 20 123 - ..219 431 208 235 , . 20 0 20 0 - 219 0 208 0 2 glazing, dr low-e 2 glazing, dr low-e 2 glazing, dr low-e .13A5ocs 13A5ocs 0.650 0.650 0.650 0.125 0.125 a a e_ -- s w 18.20 0.00 0.00 3.50 3.50 3242 0.00 0.00 . _ 1.91 1.91 45 0 0 216 160 3 0 0 216 145 819 0 0 756 508 1459 0 _ 0- 413 277 0 0 0 0. 0 0 0 -0 0 0 0 0 _ 0 _ 0 0 0 0 0 0 0 W %-G 2 glazing, dr low-e 2 glazinq, dr,low-e 18A-10)d 0.650 0.650 0.076 w w - 18.20 0.00 213 3242 .. 0.00 - _&04 15 , . 0 809 1 . 0 809 273 0 1722 486 . _. 0 2459 0 0 66 0 0 66 0 _ _ 0 140 0 _ 0 201 C F _ 22A-tph .. 1.358 - 38.02 - 0.00 809 - 79 .3004 0 -. 66 _-. 11- _ 418 0 6 c)AED excursion 0 -19 Envdope loss/gain 7969 5668 1016 519 12 a) Infiltration 1231 337 171 47 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 4300 200 Subtotal (lines 6 to 13) 9200 10305 1187 766 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 31% 0 0 0 9" 2135 0 0 0 10305 3216 239/6 31%1 0 0 0 1187 275 0 0 0 766 239 Total roan load Air required (cfm) 11334 600 13521 600 1463 77 1006 45 Calculations approved WACCA to meet all requirements of Manual J 8th Ed. -VP- wr!gftt .Mq:tr RightSuite® Universal 2021 21.0.02 RSU08101 2021 Ju123 08P:age 1 E:%Documnets%Wdghtsoft HVACIPALLAS RENOVATION.rup Calc = MJB Front Door faces: W 9 �d- wrightsoft Right-J® Worksheet Job: AHU Date: Jul 22, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOLCOM 1 Roan name NOOK BEDROOM 3 2 3 ed wall Roan height O ft 8.0 ft heat/cool 220 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 11.0 x 11.0 ft 121.0 W 11.0 x 11.0 ft 121.0 ft' y Construction number U-value Btuh/ftA-'F ( ) Or HTM (Btuh/ft') Area o perimeter (ft) Load (Btuh) (ftt or or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cod Gross N/P/S Heat Cool 6 13A-5ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.125 0.650 0.650 n n n 3.50 0.00 0.00 ' 1.91 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G ll--Gp V1/ 11 11DO 13A5ocs 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, cir low-e 13A-5ocs 13AZocs 0.390 0.125 0.650 0.650 0.650 0.125 0.125 n a a a a s w 10.92 3.50 18.20 0.00 0.00 3.50 3.50 10.34 1.91 3242 0.00 0.00 1.91 1.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0, 0 0 0 0 0 0 0 0 0 88 15 0 0 88 0 0 73 1 0 0 88 0 0 256 273 0 0 308 0 0 140 486 0 0 168 0 W W� ��G` 2 glazing, cir low-e 2 glazinq, cir low-e 18/410xd 0.650 0.650 0.076 w w_ - 18.20 0.00 213 3242 0.00 3.04 0 0 121 0 0 121 0 0 257 0 0 368 0 0 121 0 0 121 0 0 257 0 0 368 C F 22A-tph 1.358 - 38.02 0.00 121 0 0 0 121 22 837 0 6 c)AED excursion -42 -34 Envelopeloss/gain 257 326 1931 1128 12 a) Infiltration 0 0 343 94 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1400 500 Subtotal Pines 6 to 13) 257 1726 2273 1722 Less wdemal load 0 0 0 0 14 151 Less transfer Redistribution Subtotal Duct loads 23% 31% 0 0 257 60 0 0 1726 539 23% 31% 0 114 2387 554 0 64 1786 558 Total room load Air required (cfm) 317 2264 100 11556 2104 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. A& -ri- wrigtitsoTt- 2021-Jul-23 08:07:03 RlghtSuite® Universal 2021 21.0.02 RSU08101 Page 2 EADocurnnets%Wrightsoft HVAC%PALLAS RENOVATION rup Calo = MJ8 Front Door faces: W -�- wrightsofta Right-M Worksheet Job: AHU Date: Jul 22, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name CLST 3 AHU CLST 2 Exposed wall 2.0 ft 0 It 3 Room height 8.0 ft heat/cool 8.0 ft heat/cod 4 5 Room dimensions Room area 6.0 x 2.0 ft 120 ft2 5.0 x 2.0 ft 10.0 ft' Ty Constriction U-value Or HTM Area (ft-) Load Area (ft-) Load number (Btuh/ft&-F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 13A-5ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.125 0.650 0.650 n n n 3.50 0.00 0.00 1.91 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11DO 13A-5ocs 0.390 0.125 n a 10.92 3.50 10.34 1.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 VII 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, dr low-e 13A-5ocs 13A-rocs 0.650 0.650 0.650 0.125 0.125 a a a s w 18.20 0.00 0.00 3.50 3.50 32.42 0.00 0.00 1.91 1.91 0 0 0 16 0 0 0 0 16 0 0 0 0 56 0 0 0 0 31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W V� 2 glazing, cir low-e 2 glazing, clr low-e 18A-10xd 0.650 0.650 0.076 w w - 18.20 0.00 Z 13 32.42 0.00 3.04 0 0 12 0 0 12 0 0 26 0 0 36 0 0 10 0 0 10 0 0 21 0 0 30 F-C T--C C F 22A-tph 1.358 - 38.02 0.00 12 , 2 76 0 10 0 0 0 6 c)AED excursion -2 -1 Envelope loss/gain 158 65 21 30 12 a) Infiltration 31 9 0 0 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 189 74 21 30 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -189 -74 -21 -30 14 Subtotal 0 0 0 0 15 Duct loads 23% 31% 0 0 23% 31% 0 0 Total room load Air required (cfm) 0 0 0 0 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Aft� -4- wrig�+tsoft� 2021-Jul-23 08:07:03 P. RlghtSuite® Universal 2021 21.0.02 RSUD8101 Page 3 E:\Docucnnets%Wdghtsoft WACIPALLAS RENOVA7ION.rup Calc = MJ8 Front Door faces: W -�- wrightsoft RighW@ Worksheet Job: AHU Date: Jul 22, 2021 QUICK CALCS, INC. By, 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOLCOM 1 Room name CLST 2 HALLWAY 2 Fgosed wall 2.0 ft 0 ft 3 Room height 8.0 ft heat/cool &0 ft heat/trod 4 5 Room dimensions Room area 20 x 6.0 ft 120 ftz 5.0 x 5.0 ft 25.0 ft' Ty Construction U-value Or HTM Area Load Area (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cod Gross N/P/S Heat Cod 6 11 13A;5ocs 2 glazing, dr low-e 2 glazing, dr low-e 11DO _ - - 0.125 0.650 0.650 0.390. 0.125 n n n n : a 3.50 0.00 0.00 . _ 10.92 3.50 1.91 '0.00 0.00 10'34 1.91 0 0 0, 0 0 0 0 0 0 0 . 0 0 0 , -. 0 0 .0 0- 0 ._ _0 0 . _ 0 0 0 0 0 .. _ 0 0_ 0_ 0 0 , t) 0 0 . 0 0 _ 0, 0 0 0 0 Vh1345ocs 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, dr low-e _ 13A-6ocs M60cs 0.650 0.650 0.650 0.125 0.125 a a e , .. s w 18.20 0.00 0.00 3.50. 3.60 32.42 0.00 0.00 - _ 1.01 1.91 0 0 0 16 0 0 - 0 16 0 0 0 56 0 0 -0,-- 31 0 0 - . _ 9 0 0 0 .. 6 0 0 0 -.- 0 0 0 0 .._ 0 0 W 2 glazing, cir low-e 2 Clazma, dr low-e 1t3Ar10xd _ 0.650 0.650 _ " 0.076 w w_ - 18.20 . 0.00 213 32.42 .. _ . 0.00 3.04 0 - _ 0 12. 0 - - - 0 _. 12 0 _ .. ._ 0 26' 0 0 35 0 0 .. 25 0 _ ._ 0 25 0 _.- _ _ 0 53 0 - -0 76 Lr---yG C F . • _ 22A-tph _ .. 1.356 •-- - 38.02 0.00 12 2 .. 76 0 _ 25 _0 - 0 0 6 c)AED ursicn -2 -2 Envelope loss/gain 158 65 53 74 12 a) Infiltration 31 9 0 0 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 189 74 53 74 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -189 -74 -W -74 14 Subtotal 0 0 0 0 15 Duct loads 23% 31% 0 0 239/6 31% 0 0 Total room load Air required (cfm) 0 0 00 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. '4- 2021.1ul-23 08:07:03 RightSuite® Universal 2021 21.0.02 RSU08101 Page 4 E:1DocunnetsMightsoft WMPALLAS RENOVATION.rup Calc = MJ8 Front Door faces: W -�+- wrightsoft° Right-J® Worksheet Job: AHU Date: Jul 22, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Emali: QUICKCALCS ,40L,COM 1 Room name BEDROOM 2 BATH 2 2 3 Exposed wall Room height 22.0 ft 8.0 ft heal/cool &0 ft 8.0 ft heat/cool 4 5 Room dimensions Roan area 1.0 x 128.0 ft 128.0 ft2 5.0 x 8.0 ft 40.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load number (Btuhlft'-°F) (Btuh/ft2) or perimeter (ft) (Btuh) orperimeter (ft) (Btuh) Heat Cod Gross WP/S Heat . Cod Gross N/P/S Heat Cod 6 y! �---C 13A5ocs 2 glazing, dr low a 2 glazing, dr low- 0.125 0.650 0.650 n n n 3.50 0.00 0.00 1.91 0.00 0.00 -0 0 0 0 0 0 -0 0 0 0 0 0 0 0 0 - - '0 0 0 0 0 0 0 0 0 1L--(p' 11 11DO 13A5ocs 0.390 0.125 n a 10.92 3.50 10.34 1.91 0 0 .,- 0 0 = 0 0 0 0 0 40 0 25 0 88 0 48 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, dr low- 19A-5ocs 13A-5ocs 0.650 0.650 0.650 0.125 0.125 a a a a w 18.20 0.00 0.00 _ 3.50 3.50 32.42 0.00 0.00 1.91 1.91 0 0 0 80 96 0 0 0 80 81 0 0 0 - 280 284 0 0 0 153 155 15 0 0 0 0 1 0 0_ 0 0 273 0 0 0 0 486 0 0 0 0 W V�/ 1--C` 2 glazing, dr low-e 2 olazin.cdr low- 18A 10xd _ , 0.650 0.650. -, 0.076 w w_ - 18.20 0.00 2.13 32.42 -0.00-- 3.04 15 _ - 0 128 1 0 1A 273 0 272 486 0 389 0 0 40 0 0 .40 0 0 85 0 0 122 �G C F 22A vh 1.358 - 38.02 - 0.00 128 22 _ 837 0 40 5 190 . , - 0 6 c)AED exursion 186 -8 Envelope loss/gain 1945 1370 636 648 12 a) Infiltration 343 94 78 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 200 0 Subtotal Pines 6 to 13) Vw 1663 714 669 Less wdemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 2U 2510 0 106 1770 0 15 728 0 21 Wo 15 Duct loads 23% 31% 582 552 23% 31% 169 215 Total room load Air required (cfm) 3092 164 2322 103 897 48 905 40 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FP- wrigF+tsotFt- 2021^Jul-23 08:07:03 C.4�A Right -Suite® Universal 2021 21.0.02 RSU08101 Page 5 E:1DocumnetslWrlghtsoft HVACIPALLAS RENOVATION.rup Calc = MJ8 Front Door faces: W -�- wrightsoft Right-M Worksheet Job: AHU Date: Jul'22, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Emall: QUICKCALCS@AOL.COM 1 Room name DINING RM KITCHEN 2 Exposed wall 10.0 ft 5.0 ft 3 Room height 8.0 ft heaVcool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 144.0 ft 144.0 ft2 10.0 x 13.0 ft 130.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load (Btuh/ft-"F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (l3tuh) Heat Cod Gross N/P/S Heat Cod Gross N!P/S Heat Cod 6 13A 5ocs 2 glazing, dr low-e 2 glazing, dr low-e 0.125 0.650 0.650 n n n 3.50 0.00 0.00 1.91 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1i * 11 11DO 13A5ocs 0.390 0.125 n a 10.92 3.50 _ 10.34 1.91 .-_ - 0- 0 0 0 0 0 .0 0 - - 0 40 0 25 0 88 0 48 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, dr lower 0.650 0.650 0.650 a a e , 18.20 0.00 0.00 32.42 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 15 0 0 1 0 0 273 0 0 486 0 0 W V613A5ocs . 13A-5ocs " .,_ 0.125 0.125 - s w 3.50 3.50 .. 1.91 1.91 32 48 32 48 _ , - - _ 112 168 . 61 92 _ 0 0 0 0 - - _ 0 0 0 0 2 glazing, cir low-e 2 alazmq, cir.law-e 18A-10xd 0.650 0.650 0.076 w w - 18.20 0.00. Z13 32.42 0.00 3.04 0 _ _ 0 144 0 0- 144 0 - 0 , _ 306 0 0 438 0 0 130 0 A. 130 0 _ _. 0 - 277 0 0 395 C F 22A-tph - _ 1.358 - 38.02 _ 0.00 , 144 10 380 _ 0 _ .. _ 130 5 _ .. 190 0 6 c)AED exursion -44 -34 Envelope loss/gain 967 547 827 896 12 a) Infiltration 156 43 78 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants aQ 230 0 0 0 0 Appliances/other 1200 800 Subtotal (lines 6 to 13) .1123 1790 905 1717 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 87 40 15 21 14 Subtotal 1209 1829 920 1738 15 Duct loads 23% 31% 281 571 23% 31% 213 542 Total room load 1490 2400 1133 2280 Air required (cfm) 1 1 79 107 60 101 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pid- w�YgFtboft- 2021.1ul-23 08:07:03 .&'. ""'"" RightSuiteO Universal 2021 21.0.02 RSU08101 Page 6 E:1Documnets\Wrightsoft HVAC%PALLAS RENOVATION.rup Calc = M.18 Front Door faces: W - wrightsoft' Right-M Worksheet Job: MINI SPLIT Date: Jul 22, 20211 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS !AOL.COM 1 Room name MINI SPLIT MASTER BEDROOM 2 Exposed wall 91.0 ft 31.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 626.0 ft2 16.0 x 15.0 ft 240.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft5 Load number (Btuh/ftvF) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 Ti 13A-5ocs 2 glazing, dr tow-e 2 glazing, dr low-e 0.125 0.650 0.650 n n n 3.50 18.20 18.20 1.91 14.99 14.99 248 - 40 20 188 0 0 657 728 372 359._ 600 306 120 0 20 100 0 0 '349 0 372 190 0 306 11 11DO 13A-Socs 0.390 0.125 n a 0.00 3.50 0.00-- 1.91 0 176 0 136 0 476 0 260 0 128 0 88 0 308 0 168 2 glazing, dr low-e 2 glazing, dr low-e 2 glazing, cir low-e 0.650 0.650 0.650 a is e 0.00 18.20 18.20. 0.00 32-42 32.76 0 20 20 0 1 1 0 364 366 0 648 659 0 20 20 0 1 1 0 364 366 0 648 659 W y/ 13A 5ocs - - 13A-5ocs 0.125 0.125 s _ w _ _ 3.50 3.50 1.91 1.91 _ 120. 184 _ 120 144 420. 504 M9 275 0 0 0 0 0 0 0 0 2 glazing, dr low-e 2 glazinq, dr lower . 18410:a1 0.650 0.650. 0.076 w _ w - 0.00 1.8.20 Z13 0.00 32.42 3.04 0 _ 40 626 0 3 626 0 728 1332 0 - 1297 1903 0 0 240 0 _ 0 240 0 _ 0 511 0 _ 0 .730 C F 22Atph 1.358 _- 38.02 0.00 _ 626 - 91 - 3460 0 240 31 1179 0 6 c)AED excursion 0 .194 Envelope loss/gain 9406 65M 3447 2508 12 a) Infiltration 1418 388 483 132 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 7800 2900 Subtotal (lines 6 to 13) 10824 14724 3930 5540 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6894 9185 14 Subtotal 10824 14724 10824 14724 15 Duct loads 20% 22% Mi 3= 20% 22% I =I 3235 Total room load -T7 I 13030 17959 13030 17959 Air required (cfm) 800 800 800 800 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -pk- wrYghbo�t- 2021Jul-23 08:07:03 Aft Right -Suite® Universal 2021 21.0.02 RSLI08101 Page 7 E:IDocurmets%Wrightsoft WACIPALLAS RENOVATION.rup Calc = MJ8 Front Door faces: W - +- wrightsoft .Right-M Worksheet Job: MINI SPLIT Date: Jul 22, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name M WIC M BATH 2 Exposed well 11.0 ft 10.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 5.0 ft 30.0 ft2 6.0 x 10.0 ft 60.0 ft2 Ty Construction number LLvalue (Btuh/ft'L°F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Gross WP/S Heat Cod Gross WP/S Heat cod6 VJI 13A5ocs glazing, clr low-e 2 glazing, dr low- 0.125 0.650 0.650 n n n lHeatcool 1.91 14.99 14.99 0 0 0 0- 0 0 6 -0 0 0 0 0 6 0 0 0 0 0 0 0 0 02 0 0 11 11D0 13A50cs 0.390 0.125 n a 3.50 0.00 1.91 0 48 .: 0 48 0" 168 0 92 0 0 0 0 0 0 0 0 2 glazing, dr low-e 2 glazing, dr low-e 2 glazing, dr low-e _ 13A5ocs 0.650 0.650 0.650 0.125 0.125 a a a .. s w 0.00 18.20 18.20 3.50 3.50 0.00 32.42 _ 32.76 1.91 1.91 0 0 _ _ 0 40 0 0 0 0 40 0 0 0 0 140 0 0 0 0 76 0 0 0 0 80 0 0 0 0 80 0 0 0 0 280 0 0 0 .. 0 153 0 W V613A-5ocs 2 glazing, clr low-e 2 alazinrt, dr low- - 18A-10zd _ 0.650 0.650 0.076 w _ w - 0.00 18.20 2:13 0.00 32.42 . 3.04 0 0 30 0 _ 0 - 30 0 0 ` ' 64 0 _ 0 91 0 _ - _ _ 0 60 0 0 60. 0 0 _ _ . 128 0 _ 0 182 C F 22Atph--.. _ 1.358 - 38,02 0.00 30 11 , -, _ 418 - _ -0 60 10 386 0 6 c)AED excursion -44 -47 Envelope loss/gain 790 215 788 289 12 a) Infiltration 171 47 156 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants aQ 230 0 0 0 0 Appliances/other 1000 1000 Subtotal Qines 6 to 13) 962 1262 944 1332 Less edema) load 0 0 0 0 Less transfer 0 0 0 0 Redistribution .962 -1262 -944 -1332 14 Subtotal 0 0 0 0 15 Duct loads 20% 22% 0 0 20%1 220/6 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. C -r+- =igFVtBoft- 2021Jul-Jul08:07:03 Right-Sulte® Universal 2021 21.0.02 RSU08101 Page 8 EADocumnets\Wrightsoft HVAC%PALLAS RENOVATION.rup Calc = MJ8 Front Door faces: W -�- wrightsoftRight,JO Worksheet Job: MINI SPLIT Date: Jul 22, 2021 QUICK CALCS, INC. By. . 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING RM 2 Biposed wall 39.0 ft 3 Roan height 8.0 ft heat/cod 4 5 Room dimensions Room area 1.0 x 296.0 ft 296.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area Load number (Btuh/ft2-'F) (etuh/ftl or perimeter (ft) (Btuh) or perimeter Heat Cool Gross WP/S Heat Cod Gross NIP/S Hoe Cod 6 13ASocs- 2 glazing, cir low-e 2 glazing, dr low-e 0.125 0.650 0.650 n n n 3.50 18.20 18.20 1.91 14.99 14.99 128 40 0 88 0,' 0 308 728 '0 _ 168 600 0 1i , 11 11DO 13ASocs 0.390 0. . n a 0.00 3.0 0.00 1.91 ,.. , 0 0 . , .. 0 0 10 0 0 0 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 13A 5ocs 13ASocs 0.650650 0.650 0.650 0.125 0.125 a a _ e . s. w 0.000 18.20 18.E 3.60 3.50 0.00 32.42 32.76 1.91 1.91 0 0 0 0 184 0 0 0 0 144 0 0 0 0 504 0 0 0 0 275 T�� W 16 2 glazing, dr low-e 2 plazinq. olr low-e 18A-10xtf _ . 0.650 0.650 0.076 w . w_ _ - 0.00 _ _ 18.20 Z13 0.00 32.42 3.04 0 40 296 0 3 296 0 _ _ 728 630 0 1297 900 C F 22A-tph... 1.358 _ - 38.02 _ , 0.00 296 39 1483 . _ 0 6 c)AED excursion 284 Envelope loss/gain 4381 3524 12 a) infiltration 608 166 b) Room ventilation 0 0 13 Internal gains: Occupants aQ 230 0 0 Appliances/other 2900 Subtotal Pines 6 to 13) 4989 6591 Less extemal load 0 0 Less transfer 0 0 Redistribution 4989 -6591 14 Subtotal 0 0 15 Duct loads 20% 22% 0 .0 Total room load Air required (cfm) 0 0 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. A& "PI'- `MrEgl'`�c.�- 2021-Jul-23 08:07:03 "' 1 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 9 EADocumnets\Wrightsoft WACIPALLAS RENOVA110N.rup Calc = MJ8 Front Door faces: W wri htsoft® Duct System Summary Job: Date: Jul 22, 2021 AHU By: QUICK CAws, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77246"799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM f-Iroject intormation For: PALLAS RENOVATION 2504 KERR STREET, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 600 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 600 cfm 165 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 897 48 40 1.000 6.0 Ox 0 VIFx 8.0 115.0 st2 BEDROOM h 3092 164 103 .1.000 7.0 Ox0 VIFx 6.0 115.0 st1 BEDROOM h 2941 156 104 1.000 7.0 Ox0 VIFx 5.2 115.0 st1 DINING RM c 2400 79 107 1.000 7.0 Ox 0 VIFx 9.1 115.0 st2 KITCHEN c 2280 60 101 1.000 7.0 Ox0 VIFx 10.6 115.0 st2 NOOK c 2264 17 100 1.000 7.0 Ox 0 VIFx 27.4 135.0 st3 UTILITY h 1463 77 45 1.000 6.0 Ox 0 VIFx 29.8 135.0 st3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 94 145 1.000 416 8.0 0 x 0 VinlFlx st2 st2 Peak AVF 281 393 1.000 720 10.0 0 x 0 VinlFlx st1 Peak AVF 319 207 1.000 915 8.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 600 600 0 0 0 .0 Ox 0 VIFx wri�ghtsoft- 2021-Jul-23 08:07:11 i..�- '-- I— Right-Sulte® Universal 2021 21.0.02 RSU08101 Page 1 ACCA E:\Documnets\Wrightsoft WAC\PALLAS RENOVAnoRrup Calc = MJ8 Front Door faces: W -�- wrightsoft® Duct System Summary MINI SPLIT QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCSQAOL.COM For. PALLAS RENOVATION 2504 KERR STREET, FORT PIERCE, FL Job: Date: Jul 22, 2021 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 0 ft Name Design (Btuh) Htg (cfm) -Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk MASTER BEDROOM -A c 17959 800 800 1.000 13.0 OxO VIFx 0 0 Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (In) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 800 800 0 0 0 0 Ox 0 VIFx -�- wrightsoft" 2021-Jul-23 08:07:11 ^. >µ • • aa•��• •-•.•�+ . Right•Suite® Universal 2021 21.0.02 RSU08101 Page 2 �� E:\Docurmets\Wrlghtsoft WVACIPALLAS RENOVATION.rup Calc = MJ8 Front Door faces: W