HomeMy WebLinkAboutSmith WH app 3809 nimblewill ct Miranda P&ACAIIAPPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 1011512021 Permit Number:
Building Permit Application
Planning ond Development Services
Building ond Code Regulotion Division COmmefCial
2300 Virginio Avenue, Fort Pierce FL 94982
Phone: (772')462-L553 Fax: (772) 462-ti7g
Residential
PERM IT APPLICATION FOR:Water Heater
PROPOSED IMPROVEMENT LOCATION:
Address:
Property Tax lD #: 3425-706-0123-000-g
Site Plan Name:
Lot No
Block No.
Project Name: Water Heater Smith
DETAILED DESCRIPTION OF WORK:
likE fgr li(e qater heater change out -AO Smith 30 sallon electric-
tnstaileo tn ctoset
New Electrical Meter_ Second Electrical Meter (Affidavit required)
CONSTRUCTION I N FO RMATION :
Additional work to be performed under this permit - check all that apply:
_Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Windows/Doors _ pond
Electric x Plumbing _ Sprinklers _ Generator _ Roof _ Pitch
Total Sq. Ft of Construction:Sq. Ft. of First Floor:
Cost of Construction: $1612.00 Utilities: _ Sewer _ Septic Building Height:
lf value of construction is 2500 or more, a RECORDED Notice of Commencement is required.
lf value of HAVC is 57,500 or more, a RECoRDED Notice of commencement is required.
3809 Nimblewill Ct PSL, Fl 34952
OWNER/LESSEE:CONTRACTOR:
Name Robert Smith
Zip Code: 34952 Fax.
Phone No. 772-878-5123
E-Mail: njohns@mirandacompanies.com
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
Address: 3809 Nimblewill Ct
City: PSL State: -F!
Name: Don Miranda
Company: Miranda Plumbinq & Air Conditioninq
Address: 750 NW Enterprise Dr. Suite 100
City: Port Saint Lucie State: FL
ZiP Code:349ffi Fax:
Phone No 7728785123
g-1y1s11 njohns@mirandacompanies.com
State or County yissnss CFC1427227
IUGljIg
X
Name:_ Not AppiTcable
LtP: Phone
State:
MORTGAGE..MPANY, MName:
Address:
__Ltp: phone:State:
FEE SlMptE TTTLE HOLDEiT, LL r,,ryrrLE I I I LE FTULDER: __ Not ApplicablJName:
Address:
Zip: --.--ffi*
BONDINGCOMnANv,G
Name;
Address;
Zip: phon".
rlu vr q Pet IIltL.
ilth1:il!;',u'i*rl^L?i?n,'""r,r:'','"fir'fi!Hi$iiii$,u#,,fli,[#1,,H,]Tffi*;,*,lffii,:*l?iilili,.d.,r,rj"]i,:,H,ririnh
ln consideration of the
in ui.oiI.n." *iill iilE 3r#l5r"ili,i:;fJ?i::,ifB'JXilJrrE*T,":Xffi:f..l,ll,J;.r;ll[:iH"..,li;,",,",m the work
The following building permit applications are exempt from undergoing a fu, concurrency review: room additions,accessory structures' swimming poolt, iun*r, walls,'signs, ,;;";; ;;;, .nd ,..ersory il;;; another non_residentiar useWA[]I]_G To OWNIR: your failure to Record a Notice of conlTllollrints to your profeitv, e lrroti.e of cnmr,^^^:I:11"331-t,Ttv result in paying twice for
1;,,l:1i,f,ri:i::h
STATE OF FLORI
couNTy or',::
llgent for ownil
--...- online Notarization
202[ by
Swnrlto (or affirmed) and subscribed before me ofL.{Physical presence or online [\tni:rizr+;^
Personat ty Known -!jj;- prod uced tdentificatio nType of ldentificati6n--
this _ day of
)r fl\ C'JciName of p"rcon miIG statement.
STATE OF FLORIDACOUNTYOF ) -
ty"i#,1:laffirmed) and subscribed before me of
Swornp.(or affirmed) and subscribed before me of
#f nrr]::l presence or -.-.--.* Ontine Notarization
Personal ly Known *-{ o oproduced I de ntificationType of I dentificat[i-*
Produced
this -- day of
ature of Notary Ru6iiEttat6 ' -.....--
:ure oy'Notary public_ State of
on*oGG_5fSt!
FRONT
COUNTER
ZONING
REVIEW
SUPERVISOR
REVIEW
VEGETATION
REVIEW
SEA TURTLE
REVIEW
MANGROVE
REVIEW
RECEIVED
COMPLETED
zoz h ny
Smith.COMMERCIAL.GRADE
RESIDENTIAL ELECTRIC WATER HEATERS
PROLINE@ STANDARD
COM M ERCIAL-G RADE RESI DENTIAL
ENHANCED HEATING ELEMENTS
. Dual 4500 watt elements for fast recovery
and reliable operation. *
. lncoloy stainless steel Iower element lasts
longer than a standard copper element.
DYNACLEAN'" DIFFUSER DIP TUBE
. Helps reduce lime and sediment bulldup
and maximizes hot water output. tvlade
from long-lasting PEX cross-linked
polymer (diffuser design is not used on
lowboy models.)
HIGH ENERGY FACTORS
. EcoJriendly non-CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximlzes savings on operating costs.
COREGARD*ANODE ROD
. 0ur anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMOND@ GLASS COATING
. Provides superior corrosion resistance
compared to industry standard glass
lin ing.
ENHANCED-FLOW BRASS DRAIN VALVE
. 0ur residential water heaters have a solid
brass, tamper resistant, enhanced{low,
balltype, drarn valve.
. Uses a standard female hose fining that
allows for fast and easy draining during
maintenance.
. Designed for easy operation, this valve
includes an integral screwdriver slot that
features a 1/r lurn (open/close) radius,
which not only permits full straight-
through water flow but also a quick and
positive shut off.
.lVodel ENL-20 has a single element.
CODE COMPTIANCE
o Meets UBC and ICC National Codes and
listed with CEC.
. Complies with the Federal Energy
Conservation Standards effective
April 16,2015, in accordance with the
Energy Policy and Conservation Act
(EPCA), as amended.
APPROVED FOR MANUFACTURED
HOUSING
. All residential electric water heaters are
compliant with HUD Standards for mobile
homes/manufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ETECTRIC WATER HEATERS
CSA CERT!FIED AND ASME RATED T&P
RELIEF VALVE
DESIGN.LISTED BY UNDERWRITERS
LABORATORIES
. Certified at 300 psi test pressure and 1 50
psi working pressure,
. Listed according to UL 1 74 standards
governing storage tank-type electric water
heaters.
6.YEAR TIMITED TANKAND PARTS
WARRANTY
. For complete information, consult written
warranty or go to hotwater.com.
@ November 2017 A. 0. Smith Corporation.All rights reserved.
www.hotwater.com | 800'527'1 953 Toll-Free USA I A. O. Smith Corporation | 500 Tennessee Waltz parkway I Ashland city, TN 3701 5
Page 1 of 2
AOSRE50608
@.@
r r,,E-."L--r#il
(t
f-\
Male 3i4" water connections on 8" center..l\lodels ship with supplied insulation blanket,
tFor'i0-year tank and 1o-year parts wananty, change "E" to "P" in the nrodel number (example: ENT-30 becomes pNT-30).
ENL-20 is a single element confrguration only.
Ivlodels r-equir ng a lower wattage than what is list€d in the minimum wattage column and showing the @ symbol, will (hange to a "W" suffix rnodel number,"W" suffix models are available down to 1kW (example: ENS'40 using 4,000 watt elements or less will become "ENS-40W'i).
Top T&P is not available on the 1 0 year lowboy models.
Dimenslons and specifications subject to chang€ without notice in accordance with our policy o{ continuous product improvement.
@smith. l
T&P VALVE
ACCESS
PANEL
I
c
IACCESS
PANEL
DRAIN
VALVE
Model
Number
Nominal
Capacity
Rated
Storage
Volume
First Hour
Rating
(Gallons)
UEF
Recovery @
90"F Rise
Gallon
Per Hour
ElementWattage 240V Dimensions in lnches Approx.
Shipping
Weight (lbs)Standard Minimum Maximum A B c
Tall Models
ENT-3Ot 30 21 48 0.89 4500 1 000 6000 46-1t2 39-1t2 19 95
ENT-4Of 40 36 53 0.92 4500 3500 6000 61-1t4 53-1t4 1B B
ENT-5Ot 50 46 62 0.93 4500 @ 3000 6000 60-1t2 51-1t4 20-1t2 25
ENT-5OWt 50 46 45 0.88 1 000 2500 60-1t2 51-114 20-1t2 25
ENT-551 55 55 72 0.93 4500 2500 6000 56-1t2 48-1t2 24 45
Short Models
ENSB-30*30 27 50 0.90 21 4500 1 000 6000 39 30-1t2 20 95
ENS-30t 30 21 41 0.89 21 4500 1 000 6000 39-3t4 30-1t2 lt 94
ENS-401 40 31 55 0,92 21 4500 @ 4500 6000 49-3t4 40-314 20-112 109
ENS-40Wt 40 37 41 0.88 to 1 000 4000 49-3t4 40-3t4 20-112 109
ENS-50r 50 46 57 0.92 21 4500 2500 6000 49-1t4 40-3t8 23 161
Lowboy Top Connec! Models
ENL.2O 19,9 19 N/A N/A 21 4500 1 000 6000 30 21-1t4 20 65
ENLB-30*t 28 26 43 0.89 21 4500 1 000 6000 30 21-3t4 20 90
ENL-3Ot 28 26 44 0.90 21 4500 1 000 6000 31 1t4 21-3t4 24 5
ENL.36t 36 33 51 0.92 21 4500 @ 4s00 6000 32 24 24 8
ENL.36Wt 36 33 31 0. B9 1B 1 000 4000 32 24 24 B
ENL-4Ot 3B 35 50 0.89 21 4500 1 000 6000 33 1t2 24 26 B
ENIB-40* t 38 35 51 0.92 21 4500 @ 4500 6000 32 24 23 B
ENLB.4OW*t 3B 35 3B 0.90 '18
1 000 4000 32 24 1)B
ENLB-50*t 48 44 60 0.9 21 4500 @ 4000 6000 34 25 26-1t2 t2
ENLB-5OW* t 48 44 40 0.91 16 1 000 3 500 34 25 26-1t2 2
ENL-5Ot 51 4B 54 0.92 21 4500 4000 6000 36 25 26"112 2
COMMERCIAL.GRADE
RESIDENTIAL ELECTRIC WATER HEATERS
ANODE OR OPTIONAL TOP T&P
LOCATION FOR ENL.2O
SECOND ANODE ROD FOR LOWBOYS
OR OPTIONAL TOP T&P (All Other Models)
JUNCTION
BOX
T&P VALVE
@ November 2017 A. 0, Smith Corporation.All rights reserved,
www.hotwater.com | 800-527- 1 953 Toll-Free U5A
Page 2 of 2
AOSRE50608
)1
21
21
11
21
For technical information call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.