HomeMy WebLinkAboutMayrides 9632 Enclave Generator App1' - 6"3' - 4"1' - 6"1' - 6 3/4"7' - 2 1/4"1' - 3 1/2"9 7/8"2' - 1 5/8"1' - 8 1/16"6 1/16"1' - 11 3/4"6 1/16"1' - 8" 6' - 4"1' - 6 3/4"9' - 10 1/2"1' - 6 3/4"13' - 0"9 1/16"9 1/8"7 3/16"2' - 1 5/8"6' - 3 5/8"1' - 3 3/4"5' - 4 5/8"GEN SET CONTROL MIN (2) 3/4" PIPE W/SPACE TO ADD COUPLERS TO BOTH PIPES (2) 20A 120V STRANDED WIRE CIRCUITS MIN (2) 1" PIPE W/SPACE TO ADD COUPLERS TO BOTH PIPES 240V FROM ATS MULTIPLE WIRES FOR 350A NO TRIMING WIRES CONDUITS: (1) 3" (2) 2 1/2" W/SPACE TO ADD COUPLERS GAS INLET LOCATION NO SLAB CUT OUT RUN LP IN HARDPIPE ON TOP OF SLAB FASTEN PER CODE CUMMINS 80KW 350A BREAKER CUL DE SAC GOLF COURSE COOLING AIR INLET CLEARENCE 36" FROM END OF UNIT COOLING AIR OUTLET CLEARENCE 36" FROM END OF UNIT FINISHED SLAB HEIGHT MIN. 8" ABOVE SOD SLAB MIN. 6" THICK 3000# CONCRETE FIBERMESH ELECTRICAL RISER TO FPL TRANSFORMER (2) 2 1/2" CONDUIT W/ (3) 350 MCM THHN CU W/ (3) 350 MCM THHN CU (2) 2 1/2" CONDUIT IN EACH (VERIFY w/ FPL) (1) 2" CONDUIT W/ (3) 3/0 THHN CU & (1) #6 CU GRND #1 CU TIED TO EXISTING GROUNDING ELECTRODE CONDUCTOR & (2) 3/4" x 10' COPPER GRND RODS MIN. 8' APART IN EACH METER "MDP" 1∅ 400A 120/240V120/240V 200A 1∅ "A""B" 1∅ 200A 120/240V NTS 400A ATS WITH DISC. TO STANDBY GENERATOR (1) 3" CONDUIT W/ (4) 2/0 THHN CU, (2) 1/0 THHN CU & (1) #2 CU GRND W/CONTROL WIRING INSTALL & CONNECT (1) 10' COPPER GROUNDING ROD TO GENERATOR CHASIS GROUNDING LUG ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C._________________________________ ___________________________________CLIENT'S APPROVAL DATE CLIENT'S APPROVAL DATEAs indicated 10/8/2021 2:21:35 PM E-49632 Enclave CirclePort Saint Lucie, FL 34986Thomas & Miriam Mayrides 1/2" = 1'-0"1Generator Pad 1/4" = 1'-0"2Generator w/Automatic Transfer Switch SPECIFICATIONS AND INSTALLATION MANUALS SUBMITTED AS SEPARATE PDF FILES