Loading...
HomeMy WebLinkAboutAMENDMENT TO LEASE SCHEDULESite ID FL00344-B-01 Lessee Site ID 62400 Site Name Greene Property Lessee Site Name SBA Greene Property AMENDMENT TO LEASE SCHEDULE "CHIS AMENDMENT TO LEASE SCHEDULE (hereinafter 'Amendment") is made as of the c>C-f day of ^ITLing. 2013, by and between SBA TOWERS, LLC, a Florida limited liability company (hereinafter "SBA"), and VERIZON WIRELESS PERSONAL COMMUNICATIONS LP, a Delaware limited partnership d/b/a Verizon Wireless (hereinafter "Lessee") WHEREAS, SBA Towers, Inc, a Florida corporation and PnmeCo Personal Communications, Limited Partnership, a Delaware limited partnership ("PnmeCo") and SBA Communications Corporation, a Florida corporation, as guarantor, entered into a Lease Schedule dated June 1, 1998 and last executed on September 24, 1998, as amended on January 28, 2009 and on November 1, 2012 (collectively, the "Lease Schedule") pursuant to that certain Master Lease Agreement dated June 1, 1998 and last executed on September 24, 1998 (the "Agreement") and pursuant to which Lessee leases a portion of the tower site located at 25500 Minute Maid Road, Ft Pierce, FL 34951, and WHEREAS, PnmeCo Personal Communications, Limited Partnership changed its name to read Verizon Wireless Personal Communications LP on November 29, 2001, and WHEREAS, SBA Towers, Inc converted into SBA Towers, LLC effective June 30, 2011, and WHEREAS, SBA and Lessee desire and intend to amend and supplement the Lease Schedule as provided herein NOW, THEREFORE, for good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged, the parties hereto covenant, agree and bind themselves to the following modifications to the Lease Schedule 1 Paragraph 5(a) of the Lease Schedule is hereby amended to increase Lessee's current Annual Rent as follows The current Annual Rent shall be increased by Six Thousand Three Hundred and No/100 Dollars ($6,300 00), effective as determined by the date this Amendment is last executed by both parties ("Effective Date"), partial year to be prorated If the date this Amendment is last executed occurs between the first and the fifteenth day of a month, the Effective Date will be the first day of that month and, if the date this Amendment is last executed occurs on or between the sixteenth and the last day of the month, the Effective Date will be the first day of the following month Upon the anniversary and all future anniversaries of the Lease Schedule Commencement Date, Annual Rent, including any and all Annual Rent increases, will be escalated in accordance with the Lease Schedule The parties hereby acknowledge and agree that the increased annual payment(s) may not actually be sent by Lessee until thirty (30) days after the Effective Date 2 "Attachment B-2 - Lessee's Equipment" of the Lease Schedule is hereby deleted in its entirety and replaced with "Attachment B-3 - Lessee's Equipment" attached hereto and made a part of the Lease Schedule 3 Capitalized terms not defined in this Amendment will have the meaning ascribed to such terms in the Agreement and Lease Schedule 4 This Amendment will be governed by and construed and enforced in accordance with the laws of the state in which the Leased Site is located without regard to principles of conflicts of law 5 Except as specifically set forth in this Amendment, the Lease Schedule is otherwise unmodified and remains in full force and effect and is hereby ratified and reaffirmed In the event of any inconsistencies between the Lease Schedule and this Amendment, the terms of this Amendment shall take precedence 6 This Amendment shall be effective as of the date last executed by both parties Amend 3 1 f CD A j May 17 2013 [&PM| Site ID: FL00344-B-01 Site Name: Greene Property Lessee Site ID: 62400 Lessee Site Name: SBA Greene Property IN WITNESS WHEREOF, SBA and Lessee have executed this Amendment to Lease Schedule as of the date and year first above written. Signed and acknowledged in the presence of: Print Name:' le^oijk* \feiflundC Print Name ^^ ftL.. T3A^g=»i SBA: SBA TOWERS, LLC, a Florida lipiited liabilitvgc Nsrme: \lason Sifberstein tie: Senior Vice President, Property Management Date: ^ /<2'//3 Signed and acknowledged in the presence of: Print Name: Klfo illnth Print Name w/zurw. LESSEE: VERIZON 30 i/t/i Veri; S PERSONAL LP ss Name: Hans F. Leutenegger Title: Area Vice President Network Date: to]ll)3toft Amend. 3 May 17, 2013 SBA! Site ID FL00344-B-01 Site Name Greene Property Lessee Site ID 62400 Lessee Site Name SBA Greene Property ATTACHMENT B-3 Lessee's Equipment Equipment must be installed, routed and stacked pursuant to the FDH Structural Analysis dated April 29, 2013. Antennas: Quantity Type Manufacturer Model Dimensions Weight Mounting Base of the antenna Centerlme of the antenna Tip of the antenna Antennas (continued): Quantity Type Manufacturer Model Dimensions Weight Mounting Base of the antenna Centerlme of the antenna Tip of the antenna Orientation Downtilt Mount Type Cable Number of Lines Type Size Dishes: Quantity Manufacturer Model Dimensions Weight Mount Type Mounting Cable Number of lines Size/Type Tower Mounted Amplifiers (TMAs): Diplexers: Remote Radio Heads (RRHs): DC Surge Suppression System: Nine (9) Total Two (2) Two (2) Panel Panel Scala Antel AP20-1900/063D BSA-185025/12 767"x61"x14" 70 9" x 13" x 2" 15 2 lbs 13 lbs At approximately the 246' height level, Two (2) Panel CSS X7C-FRO-640-4 72"x18 8"x8 9 28 lbs At approximately the 249' height level, and At approximately the 252' height level Two (2) One(1) Panel Panel Antel CSS BSA-185065-12 2 X7-665-4 29 5" x 6 3" x 2" 72" x 12 5" x 7 1" 5 3 lbs 15 2 lbs All at the approximate height level of 248' 246' 249' 249" 250' 252' 165°, 220° & 290° 0°, 0o& 0° (3) T-Frames, per Structural Analysis Twelve (12) Coaxial 1 5/8" Four (4) Andrew UHX6-59W-S 6' 308 lbs (1) Pipe Mount, per Structural Analysis 78', 85', 99'& 120' Eight (8) 2 25"x1 31"/EW52 N/A N/A N/A N/A Amend 3 May 17, 2013 SBA Site ID FL00344-B 01 Site Name Greene Property Lessee Site ID 62400 Lessee Site Name SBA Greene Property Ground Space Requirements: Lessee provided Shelter Dimensions Type GPS Receivers: Quantity Manufacturer Model Mount Location Transmitters: Transmitter Cabinets: Quantity Frequencies: Transmitter Operating Power: ERP: Other Equipments: Automatic Transfer Switch Quantity Manufacturer/Model Power Output Microwave Links Quantity Mount Type Generator: Quantity Manufacturer/Model Power Output Location Approximately 228 8 square feet 8'x18'6" Equipment pad with cabinets 4'x10' Pad for propane tank / 500 gallon 4'x10' Pad for 30 Kw generator Two (2) PCTEL GPS-TMG-40M Within Lessee's leased area N/A Up to Seven (7) Transmit 728-787, 1950-1965 MHz 5 800-5 850, 5 925-6 425 GHz Receive 698-757, 1870-1885 MHz 5 925-6 425 GHz N/A 1640 watts/1000 watts One(1) Kohler/Mod S 340 120/240 volts, 150 Amp 1 Phase, 2 Pole Housed in 80"h x 31 5"d x 47 25"w Cabinet Two (2) Steel framing (minimum front and rear standoff of 30") One(1) Kohler Mod 30 RZ CP Gas Engine 30 Kw at 1 Phase, 60 Hz 120/240 volts Within Lessee's leased area Amend 3 May 17 2013 SBA