Loading...
HomeMy WebLinkAboutREVISION,WS LOT 17 - ENERGY CALCS, 10.16.21FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EDEN GOODMAN Street: 5158 ARMINA PL City, State, Zip: FT PIERCE , FL , Owner: EDEN MODEL LOT 17 @ WATERSTONE Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 4 5. Is this a worst case? No 6. Conditioned floor area above grade (ft� Conditioned floor area below grade (ft') 7. Windows(162.8 sgft.) Description a. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.34 c. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.27 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights C. U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types (1616.0 sgft.) Glass/Floor Area: 0.101 I hereby certify that the plans and this calculation are in compliance Code. PREPARED BY: DATE: Area 104,56 ft' 42.08 ftz ft 16.19 ' 4,840 ft. 0,307 Area ft' Builder Name: KHOVNANAIN HOMES Permit Office: Permit Number: Jurisdiction: County: St. Lucie (Florida Climate Zone 2 ) 10. Wall Type$1808.3 sgft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1528.30 ft' b. Frame - Wood, Adjacent R=11.0 280,00 ft' a N/A R= ft' d. N/A R= ft' 11. Ceiling Types (1618,0 sgft.) Insulation Area a. Under Attie (Vented) R=30.0 1618.00 ft' b. N/A R= ft' c. N/A R= ft' 12. Ducts R ft' a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 325 13. Cooling systems a. Central Unit 14. Heating systems a. Electric Strip Heat Insulation 15. Hot water systems a. Electric Area R=0.0 1616.00 ft' b. Conservation features R= ft' None R= ft' 16, Credits Total Proposed Modified Loads: 54.55 Total Baseline Loads: 65.67 lions covered by Florida Energy I hereby certify th th building, as designed, is in compliance with the Florida En y ode. / ^n�� OWNER/AGEN DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be Inspected for compliance with Section 553.908 Florida Statutes, BUILDING OFFICIAL: DATE: kBtu/hr EiFclency 28.0 SEER:16.00 kBtWhr Efficiency 23.0 COP:1.00 Cap: 50 gallons EF: 0,930 PASS Pstat - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/9/2021 6:31 AM EnergyGaugeC� USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-EDEN GOODMAN Bedrooms: 4 Building Type: User Conditioned Area: 1616 Address Type: Lot # Street Address Owner Name: EDEN MODEL LOT 17 @ W Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 135 Street: 5158 ARMINA PL Permit Office: Jurisdiction: Family Type: Detached New/Existing: New (From Plans) Cross Ventilation: No Whole House Fan: No County: City, State, Zip: St. Lucie FT PIERCE , FL Comment: CLIMATE / V Design Location Design TMY Site 97.5 % Temp 2.5 % Int Design Temp Healing Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1616 14220.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BED 3 161 1416,8 No 1 4 1 No Yes Yes 2 HALL BATH 77 678 No 0 1 No Yes Yes 3 FOYER 172 1514 No 0 1 No Yes Yes 4 BED 4 149 1307 No 1 1 No Yes Yes 5 LAUNDRY 52 458 No 0 1 No Yes Yes 6 BED 2 149 1307 No 1 1 No Yes Yes 7 GIRT DIN KITCHEN 650 4840 No 0 1 No Yes Yes 8 MASTER SUITE 176 1544 No 2 1 No Yes Yes 9 MAST WIC 58 506 No 0 1 No Yes Yes 10 M BATH 72 634 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 3 38 it 0 163 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio HALL BATH lift 0 77 ft' 1 0 0 3 Slab -On -Grade Edge Insulatio FOYER 25 ft 0 172 ft' ___ 1 0 0 4 Slab -On -Grade Edge Insulatio BED 4 14 ft 0 148.5 ft' 0 1 0 5Slab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 52 ft' ____ 1 0 0 6 Slab -On -Grade Edge Insulatio BED 2 115 ft 0 148.5 ft' ____ 0 1 0 7SIab-On-Grade Edge Insulatio GIRT DIN KITCHE 49 ft 0 550 ft' 0.25 0.5 025 10/9/2021 6;31 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edi[ion (2020) Compliant Software Page 2 of 5 FORM R405-2020 IKIPI IT RI IMMA14V ('Wll:rwl ICT oconD-r FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5 it 0 175.5 ft' 0 1 0 ____ 9 Slab -On -Grade Edge Insulatio MAST WIC 11.5 ft 0 57.5 ft' ____ 0 1 0 10SIab-On-Grade Edge Insulatio M BATH 1 It 0 72 ft' ____ 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1750 ft' oft' Medium N 0.9 No 0.9 No 0 22.6 ATTIC / 1r If Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1616 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) BED 3 30 Blown 163 W 0.1 Wood 2 Under Attic (Vented) HALL BATH 30 Blown 77 ft' 0.1 Wood 3 Under Attic (Vented) FOYER 30 Blown 172 ft' 0.1 Wood 4 Under Attic (Vented) BED 4 30 Blown 149 ft' 0.1 Wood 5 Under Attic (Vented) LAUNDRY 30 Blown 52 ft' 0.1 Wood 6 Under Attic (Vented) BED 2 30 Blown 149 ft' 0.1 Wood 7 Under Attic (Vented) GRT DIN KITCHE 30 Blown 550 ft' 0.1 Wood 8 Under Attic (Vented) MASTER SUITE 30 Blown 176 ft' 0.1 Wood 9 Under Attic (Vented) MAST WIC 30 Blown 58 ft' 0.1 Wood 10 Under Attic (Vented) M BATH 30 Blown 72 ft' 0.1 Wood WALLS t Adjacent To Wan Typp space Cavity Width RWAIIIA Height Sheathing Framing Solar Below Ft In Ft In Area R-vat _ 1 NE=>S Exterior Concrete Block - Int Insul BED 3 4.1 13 1 9 4 122.1 ft' 0 0 0.5 0 2 SE=>W Exterior Concrete Block - Int Insul BED 3 4.1 10 8 9 4 99.6 ft' 0 0 0.5 0 3 SW=>N Exterior Concrete Block- Int Insul BED 3 4.1 12 2 10 0 121.7 ft' 0 0 0.5 0 _ 4 SW=>N Exterior Concrete Block - Int InsdI ALL BATH 4.1 9 11 10 0 99.2 ft' 0 0 0.5 0 _ 5 SE=>W Exterior Concrete Block- Int Insul FOYER 4.1 4 10 9 4 45.1 ft' 0 0 0.5 0 6 SW=>N Exterior Concrete Block- Int Insul BED 4 4.1 12 7 10 0 125.8 ft' 0 0 0.5 0 7 NE=>S Exterior Concrete Block- Int Insul BED 2 4A 13 1 9 4 122.1 ft' 0 0 0.5 0 _ 8 SW=>N Exterior Concrete Block- Int InsORT DIN KIT 4A 22 6 10 0 225.0 ft' 0 0 0.5 0 _ 9 NW=>E Exterior Concrete Block - Int InsORT DIN KIT 4.1 12 3 9 4 114.3 it' 0 0 0.5 0 _10 NE=>S Exterior Concrete Block - Int InsMASTER SUI 4.1 12 7 9 4 117A ft' 0 0 0.5 0 _11 NW=>E Exterior Concrete Block- Int InsMASTER SUI 4A 12 7 9 4 117.4 ft' 0 0 0.5 0 12 NE=>S Exterior Concrete Block - Int InsuMAST WIC 4.1 11 2 9 4 104.2 ft' 0 0 0.5 0 10/9/2021 6:31 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FnPhll PAnV-f)mn IMP[ 1T Sl1MMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space - tue In Ft In A R \/ I F I' Ah G 13 NW=>E Garage Frame - Wood FOYER 11 30 0 9 4 280.0 ft' 0 0 0.5 0 14 NW=>E Exterior Concrete Block - Int InsORT DIN KIT 4.1 12 3 9 4 114.3 W 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW=>E Insulated FOYER None AS 3 8 24W 2 NW=>E Wood FOYER None .46 2.8 6.8 19 ft' WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 135 degrees), / Wall Overhang V # Ornt ID Frame Panes NFRC U•Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 SE=>W 2 Metal Double (Tinted) Yes 0.32 0.27 N 16.2 W 1 it 0 in 1 it 0 in None None 2 SW=>N 6 Metal Double (Tinted) Yes 0.32 0.3 N 16.2 ft' 1 it 0 in 1 ft 0 in None None 3 NE=>S 7 Metal Double (Tinted) Yes 0.32 0.3 N 16.2 ft' 1 It 0 in 1 ft 0 in None None 4 SW=>N 8 Metal Double (Tinted) Yes 0.55 0.34 N 42.1 ft' 11 it 0 in 1 ft 0 in None None _ 5 NW=>E 14 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 ft` 1 It 0 in 1 ft 0 in None None _ 6 NW=>E 9 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 W 9 It 6 in 1 It 0 in None None 7 NW=>E 11 Metal Double (Tinted) Yes 0.32 0.3 N 24.1 ft' 1 ft 0 In 1 It 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft' 380 ft' 64 It 8 it 1 INFILTRATION # Scope Method SLA CFM 50 EtA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1657.2 90.92 170.69 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 23 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit] Split Singl SEER: 16 28 kBtu/hr 840 cfm 0.71 1 sys#1 10/9/2021 6:31 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 • : u : � � � . • u u e : L�i:1X�3./�F3i:7�i7i� HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / -- Supply ---- --• Return --- Air CFM 25 CFM25 HVAC # _ V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 325 ft' HALL BATH 1112 Default Leakage HALL BAT (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin rr Jan (r Feb �fJC��Mar rr A r May X Jun 4X Jul Jul frX Au Aug rrX Se Sep rr Oct [(X�]Nov Oct Nov ([ Dec Dec Venting [ Jan [ Feb [X7 Mar (X� Apr May Jun (� [ [ [X� (X] [XI Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 It 0.3 BED 3 Default(8 lbs/sq.ft. W ft 0.3 HALL BATH Default(8 lbs/sq.ft. ft' it 0.3 FOYER Default(8 lbs/sq.ft. ftZ it 0.3 BED 4 Default(8 lbslsq.ft, ft' ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' It 0.3 BED 2 Default(8 lbs/sq.ft. ft' It 0.3 GRT DIN KITCHEN Default(8 lbs/sq.ft. ft' it 0.3 MASTER SUITE Default(8 lbs/sq.ft, ft' it 0.3 MASTWIC Default(8 lbs/s.ft. ft' it 0.3 M BATH 10/9l2021 6:31 AM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th EdHion (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPertormance Index, the more efficient the home. 5158 ARMINA PL, FT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - int Insul, Exterior R=4.1 1528.30 ftz b. Frame- Wood, Adjacent 11=11.0 280,00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft' 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1618.00ft' 6. Conditioned floor area (ft') 1616 b. N/A R= ft' 7. Windows" Description Area c. N/A R= ft' a. U-Factor: Dbl, U=0.32 104,66 ft' 12. Ducts, location & insulation level R ftr SHGC: SHGC=0.30 a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 325 b. U-Factor: Dbl, U=0.55 42,08 ft' SHGC: SHGC=0.34 13, Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.32 16,19 ft' a. Central Unit 28.0 SEER:16.00 SHGC: SHGC=0.27 d. r: N/A ft' SHGC: 14. Heating systems kBtu/hr Efficiency SHGC; Area Weighted Average Overhang Depth: 4.840 ft. a. Electric Strip Heat 23.0 COP:1.00 Area Weighted Average SHGC: - 0.307 8. Skylights Description Area 15, Hot water systems a. Electric Cap: 50 gallons a. U-Factor(AVG): N/A ft' EF: 0.93 SHGC(AVG): WA b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft' Credits (Performance method) Pstat b. N/A R= ftl c. N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed t .. compliant features. Builder Signature: Date: C) I t �,J Address of New Home: Iq City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1019I2021 6:37 AM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1