HomeMy WebLinkAboutREVISION,WS LOT 17 - ENERGY CALCS, 10.16.21FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EDEN GOODMAN
Street: 5158 ARMINA PL
City, State, Zip: FT PIERCE , FL ,
Owner: EDEN MODEL LOT 17 @ WATERSTONE
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
2. Single family or multiple family Detached
3. Number of units, if multiple family 1
4. Number of Bedrooms 4
5. Is this a worst case? No
6.
Conditioned floor area above grade (ft�
Conditioned floor area below grade (ft')
7.
Windows(162.8 sgft.)
Description
a. U-Factor:
Dbl, U=0.32
SHGC:
SHGC=0.30
b. U-Factor:
Dbl, U=0.55
SHGC:
SHGC=0.34
c. U-Factor:
Dbl, U=0.32
SHGC:
SHGC=0.27
Area Weighted Average
Overhang Depth:
Area Weighted Average
SHGC:
8.
Skylights
C. U-Factor:(AVG)
N/A
SHGC(AVG):
N/A
9.
Floor Types (1616.0 sgft.)
Glass/Floor Area: 0.101
I hereby certify that the plans and
this calculation are in compliance
Code.
PREPARED BY:
DATE:
Area
104,56 ft'
42.08 ftz ft 16.19 '
4,840 ft.
0,307
Area
ft'
Builder Name: KHOVNANAIN HOMES
Permit Office:
Permit Number:
Jurisdiction:
County: St. Lucie (Florida Climate Zone 2 )
10. Wall Type$1808.3 sgft.) Insulation Area
a. Concrete Block - Int Insul, Exterior R=4.1 1528.30 ft'
b. Frame - Wood, Adjacent R=11.0 280,00 ft'
a N/A R= ft'
d. N/A R= ft'
11. Ceiling Types (1618,0 sgft.) Insulation Area
a. Under Attie (Vented) R=30.0 1618.00 ft'
b. N/A R= ft'
c. N/A R= ft'
12. Ducts R ft'
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 325
13. Cooling systems
a. Central Unit
14. Heating systems
a. Electric Strip Heat
Insulation
15. Hot water systems
a. Electric
Area
R=0.0 1616.00 ft' b. Conservation features
R= ft' None
R= ft' 16, Credits
Total Proposed Modified Loads: 54.55
Total Baseline Loads: 65.67
lions covered by
Florida Energy
I hereby certify th th building, as designed, is in compliance
with the Florida En y ode. / ^n��
OWNER/AGEN
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be Inspected for
compliance with Section 553.908
Florida Statutes,
BUILDING OFFICIAL:
DATE:
kBtu/hr EiFclency
28.0 SEER:16.00
kBtWhr Efficiency
23.0 COP:1.00
Cap: 50 gallons
EF: 0,930
PASS
Pstat
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/9/2021 6:31 AM EnergyGaugeC� USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-EDEN GOODMAN Bedrooms: 4
Building Type: User Conditioned Area: 1616
Address Type:
Lot #
Street Address
Owner Name: EDEN MODEL
LOT 17 @ W Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: KHOVNANAIN
HOMES Rotate Angle: 135
Street:
5158 ARMINA PL
Permit Office:
Jurisdiction:
Family Type: Detached
New/Existing: New (From Plans)
Cross Ventilation: No
Whole House Fan: No
County:
City, State,
Zip:
St. Lucie
FT PIERCE ,
FL
Comment:
CLIMATE
/
V Design Location
Design
TMY Site 97.5 %
Temp
2.5 %
Int Design Temp Healing Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce
FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1616 14220.8
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 BED 3
161 1416,8 No
1
4
1
No
Yes
Yes
2 HALL BATH
77 678 No
0
1
No
Yes
Yes
3 FOYER
172 1514 No
0
1
No
Yes
Yes
4 BED 4
149 1307 No
1
1
No
Yes
Yes
5 LAUNDRY
52 458 No
0
1
No
Yes
Yes
6 BED 2
149 1307 No
1
1
No
Yes
Yes
7 GIRT DIN KITCHEN 650 4840 No
0
1
No
Yes
Yes
8 MASTER SUITE
176 1544 No
2
1
No
Yes
Yes
9 MAST WIC
58 506 No
0
1
No
Yes
Yes
10 M BATH
72 634 No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter
R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge
Insulatio BED 3 38 it 0
163 ft'
___
0 1
0
2 Slab -On -Grade Edge
Insulatio HALL BATH lift 0
77 ft'
1 0
0
3 Slab -On -Grade Edge
Insulatio FOYER 25 ft 0
172 ft'
___
1 0
0
4 Slab -On -Grade Edge
Insulatio BED 4 14 ft 0
148.5 ft'
0 1
0
5Slab-On-Grade Edge
Insulatio LAUNDRY 1 ft 0
52 ft'
____
1 0
0
6 Slab -On -Grade Edge
Insulatio BED 2 115 ft 0
148.5 ft'
____
0 1
0
7SIab-On-Grade Edge
Insulatio GIRT DIN KITCHE 49 ft 0
550 ft'
0.25 0.5
025
10/9/2021 6;31 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edi[ion (2020) Compliant Software Page 2 of 5
FORM R405-2020 IKIPI IT RI IMMA14V ('Wll:rwl ICT oconD-r
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist
R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5
it 0
175.5 ft'
0
1
0
____
9 Slab -On -Grade Edge Insulatio
MAST WIC 11.5
ft 0
57.5 ft'
____
0
1
0
10SIab-On-Grade Edge Insulatio
M BATH 1 It
0
72 ft'
____
1
0
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type
Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 1750 ft'
oft' Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
/
1r
If
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented
150
1616 ft'
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
_
1
Under Attic (Vented)
BED 3
30
Blown
163 W
0.1
Wood
2
Under Attic (Vented)
HALL BATH
30
Blown
77 ft'
0.1
Wood
3
Under Attic (Vented)
FOYER
30
Blown
172 ft'
0.1
Wood
4
Under Attic (Vented)
BED 4
30
Blown
149 ft'
0.1
Wood
5
Under Attic (Vented)
LAUNDRY
30
Blown
52 ft'
0.1
Wood
6
Under Attic (Vented)
BED 2
30
Blown
149 ft'
0.1
Wood
7
Under Attic (Vented)
GRT DIN KITCHE 30
Blown
550 ft'
0.1
Wood
8
Under Attic (Vented)
MASTER SUITE 30
Blown
176 ft'
0.1
Wood
9
Under Attic (Vented)
MAST WIC
30
Blown
58 ft'
0.1
Wood
10
Under Attic (Vented)
M BATH
30
Blown
72 ft'
0.1
Wood
WALLS
t
Adjacent
To Wan Typp
space
Cavity Width
RWAIIIA
Height
Sheathing
Framing Solar
Below
Ft
In Ft
In
Area
R-vat
_ 1
NE=>S
Exterior Concrete
Block -
Int Insul BED 3
4.1 13
1 9
4
122.1 ft'
0
0
0.5
0
2
SE=>W
Exterior Concrete
Block -
Int Insul BED 3
4.1 10
8 9
4
99.6 ft'
0
0
0.5
0
3
SW=>N
Exterior Concrete
Block-
Int Insul BED 3
4.1 12
2 10
0
121.7 ft'
0
0
0.5
0
_ 4
SW=>N
Exterior Concrete
Block -
Int InsdI ALL BATH
4.1 9
11 10
0
99.2 ft'
0
0
0.5
0
_ 5
SE=>W
Exterior Concrete
Block-
Int Insul FOYER
4.1 4
10 9
4
45.1 ft'
0
0
0.5
0
6
SW=>N
Exterior Concrete
Block-
Int Insul BED 4
4.1 12
7 10
0
125.8 ft'
0
0
0.5
0
7
NE=>S
Exterior Concrete
Block-
Int Insul BED 2
4A 13
1 9
4
122.1 ft'
0
0
0.5
0
_ 8
SW=>N
Exterior Concrete
Block-
Int InsORT DIN KIT
4A 22
6 10
0
225.0 ft'
0
0
0.5
0
_ 9
NW=>E
Exterior Concrete
Block -
Int InsORT DIN KIT
4.1 12
3 9
4
114.3 it'
0
0
0.5
0
_10
NE=>S
Exterior Concrete
Block -
Int InsMASTER SUI
4.1 12
7 9
4
117A ft'
0
0
0.5
0
_11
NW=>E
Exterior Concrete
Block-
Int InsMASTER SUI
4A 12
7 9
4
117.4 ft'
0
0
0.5
0
12
NE=>S
Exterior Concrete
Block -
Int InsuMAST WIC
4.1 11
2 9
4
104.2 ft'
0
0
0.5
0
10/9/2021 6:31 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
FnPhll PAnV-f)mn IMP[ 1T Sl1MMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height Sheathing
Framing Solar
Below
Space
- tue In Ft
In A R \/ I
F I' Ah
G
13 NW=>E Garage Frame - Wood FOYER
11 30 0 9
4 280.0 ft' 0
0 0.5
0
14 NW=>E Exterior Concrete Block - Int InsORT DIN KIT 4.1 12 3 9
4 114.3 W 0
0 0.5
0
DOORS
# Ornt
Door Type Space
Storms
U-Value Width
Height
Area
Ft In
Ft In
1 NW=>E
Insulated FOYER
None
AS 3
8
24W
2 NW=>E
Wood FOYER
None
.46 2.8
6.8
19 ft'
WINDOWS
Orientation shown is the entered
orientation => changed to As
Built rotated 135 degrees),
/ Wall
Overhang
V # Ornt ID Frame
Panes NFRC
U•Factor SHGC Imp
Area Depth Separation
Int Shade
Screening
_ 1 SE=>W 2 Metal
Double (Tinted) Yes
0.32 0.27 N
16.2 W 1 it 0 in 1 it 0 in
None
None
2 SW=>N 6 Metal
Double (Tinted) Yes
0.32 0.3 N
16.2 ft' 1 it 0 in 1 ft 0 in
None
None
3 NE=>S 7 Metal
Double (Tinted) Yes
0.32 0.3 N
16.2 ft' 1 It 0 in 1 ft 0 in
None
None
4 SW=>N 8 Metal
Double (Tinted) Yes
0.55 0.34 N
42.1 ft' 11 it 0 in 1 ft 0 in
None
None
_ 5 NW=>E 14 Metal
Double (Tinted) Yes
0.32 0.3 N
24.1 ft` 1 It 0 in 1 ft 0 in
None
None
_ 6 NW=>E 9 Metal
Double (Tinted) Yes
0.32 0.3 N
24.1 W 9 It 6 in 1 It 0 in
None
None
7 NW=>E 11 Metal
Double (Tinted) Yes
0.32 0.3 N
24.1 ft' 1 ft 0 In 1 It 0 in
None
None
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 380 ft'
380 ft'
64 It
8 it
1
INFILTRATION
# Scope Method
SLA
CFM 50 EtA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000391
1657.2 90.92 170.69
.1312
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/ None
COP:1
23 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit]
Split
Singl SEER: 16
28 kBtu/hr 840 cfm
0.71 1
sys#1
10/9/2021 6:31 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
• : u : � � � . • u u e : L�i:1X�3./�F3i:7�i7i�
HOT WATER SYSTEM
#
System
Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.93
50 gal
60.9 gal
120 deg
None
SOLAR HOT
WATER SYSTEM
FSEC
Collector Storage
Carl #
Company Name
System Model #
Collector Model
# Area
Volume
FEF
None
None
ft'
DUCTS
/
--
Supply ----
--• Return ---
Air
CFM 25
CFM25
HVAC #
_
V #
Location R-Value
Area
Location
Area
Leakage
Type
Handler
TOT
OUT ON RLF
Heat Cool
1
Attic
6 325 ft'
HALL BATH 1112
Default Leakage
HALL BAT
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat:
Y
Ceiling Fans:
Coolin rr Jan (r
Feb
�fJC��Mar
rr
A r
May
X Jun
4X Jul
Jul
frX Au
Aug
rrX Se
Sep
rr Oct [(X�]Nov
Oct Nov
([ Dec
Dec
Venting [ Jan [
Feb
[X7 Mar
(X�
Apr
May
Jun
(�
[
[
[X� (X]
[XI
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10 11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80 80
80
PM
80
80
78
78
78
78
78
78
78 78 78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78 78
78
PM
78
78
78
78
78
78
78
78
78 78 78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68 68
68
PM
68
68
68
68
68
68
68
68
68 68 66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68 68
68
PM
68
68
68
68
68
68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8
Ibs/sq.ft.
0 ft2
0 It
0.3
BED 3
Default(8
lbs/sq.ft.
W
ft
0.3
HALL BATH
Default(8
lbs/sq.ft.
ft'
it
0.3
FOYER
Default(8
lbs/sq.ft.
ftZ
it
0.3
BED 4
Default(8
lbslsq.ft,
ft'
ft
0.3
LAUNDRY
Default(8
lbs/sq.ft.
ft'
It
0.3
BED 2
Default(8
lbs/sq.ft.
ft'
It
0.3
GRT DIN KITCHEN
Default(8
lbs/sq.ft.
ft'
it
0.3
MASTER SUITE
Default(8
lbs/sq.ft,
ft'
it
0.3
MASTWIC
Default(8
lbs/s.ft.
ft'
it
0.3
M BATH
10/9l2021 6:31 AM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th EdHion (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPertormance Index, the more efficient the home.
5158 ARMINA PL, FT PIERCE, FL,
1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a. Concrete Block - int Insul, Exterior R=4.1 1528.30 ftz
b. Frame- Wood, Adjacent 11=11.0 280,00 ft'
3. Number of units, if multiple family 1 c. N/A R= ft'
4. Number of Bedrooms 4 d. N/A R= ft'
5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area
a. Under Attic (Vented) R=30.0 1618.00ft'
6. Conditioned floor area (ft') 1616 b. N/A R= ft'
7. Windows" Description Area c. N/A R= ft'
a. U-Factor: Dbl, U=0.32 104,66 ft' 12. Ducts, location & insulation level R ftr
SHGC: SHGC=0.30 a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 325
b. U-Factor: Dbl, U=0.55 42,08 ft'
SHGC: SHGC=0.34 13, Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl, U=0.32 16,19 ft' a. Central Unit 28.0 SEER:16.00
SHGC: SHGC=0.27
d. r: N/A ft'
SHGC: 14. Heating systems kBtu/hr Efficiency
SHGC; Area Weighted Average Overhang Depth: 4.840 ft. a. Electric Strip Heat 23.0 COP:1.00
Area Weighted Average SHGC: - 0.307
8. Skylights Description Area 15, Hot water systems
a. Electric Cap: 50 gallons
a. U-Factor(AVG): N/A ft' EF: 0.93
SHGC(AVG): WA b. Conservation features
9. Floor Types Insulation Area None
a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft' Credits (Performance method) Pstat
b. N/A R= ftl
c. N/A R= ft'
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed t .. compliant features.
Builder Signature: Date: C) I t �,J
Address of New Home: Iq City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1019I2021 6:37 AM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1